Emergency

LED Exit 2

DOT 1250 / E 13

Director 4

Nipper / E 14

Director LED 6

High 5 / E 16

Stingray 7

Regency Bare 18

Stingray LED 8

Regency Diffused 19

Futcha 5 LED 9

Deluxe Bare Batten 20

LED Firefly 10

Deluxe Diffused 21

Firefly 12

Unilux 22

Emergency

ET Troffer 23

Vandal X IP65 32

Vandalux 42

TR322 24

Extreme 33

NXS 44

Condo 26

EXDN IP66 34

Maxi Pac IP65 46

Hades I - LED / E 27

Condo WP 35

Metro Emergency 47

DIGINET
Guardian GR99 28 PWP & PWA 36

48

Guardian GR21 29

SDW / SDWA 37

DIGINET DALI Emergency Control Panel 49 DIGINET Cable Management Options 50

Weatherlux 30

SDIP 38

Warden LED 31

Vandaguard 39

Technical 51

Emergency

LED Exit
Stylish, energy efficient LED exit luminaire compliant to Australian emergency lighting standards AS/NZS2293.

Features
50,000 hour strip LED lamps Polycarbonate housing Slimline acrylic legend blade Fully approved to AS/NZS2293 thermal & illuminance requirements Pictogram viewing distance is 24m Surface & Recessed mount, Swivel action of panel for use on angled ceilings Low power consumption A complete one box solution including body diffuser and all pictogram inserts Optional black theatre body housing and picto inserts Optional DALI monitored systems available

Applications
Ideal for emergency lighting application where aesthetics are everything, commercial office areas, hotels, shopping and cinema complexes, apartments, hospitals.

Product Codes

Technical

Code
LEDXM2P LEDXM2PB

Version
LED Exit with Pictogram Inserts LED Exit with Black body and Green/ Black Theatre Pictogram

Product Code
LEDXM2P C0 C90

Classification
D1.25 D1.25

2.1 4 4

Mounting Height in Metres


2.4 3.8 3.8 2.7 3.4 3.4 3 2.9 2.9

Accessories
3.6 2 2

LEDRB EXCB LEDCM SKITLED 99023330 99023360 DIRPPSS DIRPPDS Spare Parts: BP2SSC

Recessed Bracket (cut-out: 380x88mm) Cantilever bracket Conduit mount box Suspension Kit Rod suspension white Rod suspension black Pictogram inserts single sided Pictogram inserts Double sided 2.4V NiCad, 2Cell

All pictogram inserts

IP20

Emergency

max dim(mm)
2.0kg

368 x 55 x 255

LED Swivel Action - Wall or Ceiling Mount

Conduit Mount Box LEDCM

Cantilever Bracket EXCB

Emergency

Director
Traditional style exit luminaire complete with diffuser and pictogram legend compliant to AS/NZS2293.

Features
Energy efficient lamp 10 watt fluorescent Quick connect removable gear tray Surface mount wall / ceiling Injection moulded ABS housing and acrylic diffuser with pictogram legend Maintained, non-maintained and sustained available Viewing distance 24m Optional opal diffuser A complete One Box solution including body, diffuser and all pictogram inserts Compliant to AS/NZS2293

Product Codes Code Version

Applications
General purpose interior exit luminaire, commercial buildings, shops and interior carparks.

Body less diffuser DIR10M DIR10NM DIR10S DIR10MPSS 10W Maintained 10W Non-Maintained 2x10W Sustained 10W Maintained 10W Sustained

Pictogram wall mount single sided complete DIR10SPSS

Technical
Product Code
DIR10MPSS DIR10MPDS DIR10SPSS DIR10SPDS DIR10M + DIRDS C0 C90 C0 C90 C0 C90 C0 C90 C180 C0 C90

DIR10NMPSS 10W Non-Maintained


Classification
D5 E3.2 D6.3 E5 D8 E5 D5 E5 D6.3 D10 E12.5 2.1 7.8 6 8.6 6.6 9.4 6.6 7.8 6.6 8.6 10.2 8 2.4 8 6.2 8.8 7.2 9.7 7.2 8 7.2 8.8 10.6 8.8 2.7 8.1 6.4 9 7.4 9.9 7.4 8.1 7.4 9 10.9 9.4 3 8.2 6.6 9.1 7.8 10.1 7.8 8.2 7.8 9.1 11.1 10

Mounting Height in Metres


3.6 8.2 6.6 9.2 8.2 10.3 8.2 8.2 8.2 9.2 11.4 11 4 8 6.6 9.2 8.4 10.4 8.4 8 8.4 9.2 11.5 11.4 4.5 7.7 5.8 9 8.4 10.3 8.4 7.7 8.4 9 11.6 12

Pictogram ceiling mount double sided complete


5 7.3 5.8 8.7 8.2 10.2 8.2 7.3 8.2 8.7 11.6 12.4 6 5.7 7.7 7 9.5 7 5.7 7 7.7 11.2 13 8 1.6 5.7 6.8 8.3 6.8 1.6 6.8 5.7 10.3 12.8 10

DIR10MPDS DIR10SPDS

10W Maintained 10W Sustained

DIR10NMPDS 10W Non-Maintained


6.1

Accessories
DIRPSS Diffuser wall mount c/w Picto inserts Diffuser ceiling mount c/w Picto inserts Diffuser wall mount opal only Diffuser ceiling mount opal only Director inserts packet, wall mount Director inserts packet, ceiling mount Wall mount wire guard Ceiling mount wire guard DIRPDS DIRSS DIRDS DIRPPSS DIRPPDS

8.9 11.6

All pictogram inserts

WGWE WGCE

IP20

Emergency

max dim(mm)
2kg

380 x 160 x 220

Technical

Max Dim(mm)

Emergency

Director LED
Traditional style Exit luminaire complete with energy efficient LED technology.

Features
LED long life Exit sign, 50,000hrs Quick connect removeable gear tray Surface mount Wall/ Ceiling Injection moulded ABS housing and acrylic diffuser with Pictogram Legends Maintained Viewing Distance 24M NiCad high temperature battery system Optional Opal Diffuser included A complete One Box solution including body, diffuser and all pictogram inserts

Applications
General purpose interior exit luminaire, commercial buildings, shops, carparks etc.

Product Codes

Technical
Product Code DIRLEDPSS C0 C90 C180 C0 C90 C180 Classification E2.5 E2.5 B2.5 D4 D5 D4 2.1 5.6 5.6 3.7 7 .2 7 .8 7 .2 2.4 5.8 5.8 3.8 7 .3 8 7 .3 Mounting Height in Metres 2.7 3 3.6 4 4.5 5.8 6 5.8 5.2 5.2 5.8 6 5.8 5.2 5.2 3.8 3.8 3.6 3.2 2.4 7 .3 7 .3 7 .2 6.9 6.5 8.1 8.2 8.2 8 7 .7 7 .3 7 .3 7 .2 6.9 6.5 5 4.6 4.6 5.8 7 .3 5.8 6

Code
DIRLEDPSS DIRLEDPDS
3.1 5.7 3.1

Version
Director LED Picto Wall Mount Maintained Exit Director LED Picto Ceiling Mount Maintained Exit

Accessories
Diffusers: DIRPSS DIRPDS DIRSS DIRDS DIRPPSS DIRPPDS WGWE WGCE Diffuser wall mount incl. Picto Inserts Diffuser Ceiling mount incl. Picto Inserts Diffuser wall mount Opal only Diffuser Ceiling mount Opal Only Director Inserts Packet, Wall mount Director Inserts Packet, Ceiling mount Wall mount wire gaurd Ceiling mount Wire Gaurd

DIRLEDPDS

All pictogram inserts


IP20 max dim(mm)
2.0kg

Emergency

380 x 160 x 220

Stingray
A stylish, quick connect fluorescent exit luminaire compliant to Australian emergency lighting standards AS/NZS2293.

Features
Energy efficient lamp 10W fluorescent Quick slide connect installation Surface mount, wall or ceiling mounting options Maintained or sustained circuits Viewing distance 24M Complete one box solution, including diffusers and Picto inserts Polycarbonate housing and diffuser Compliant to AS/NZS2293

Tough polycarbonate lens

Applications
Commercial office areas, apartment buildings, shopping centres & arcades, cinemas & halls and internal carparks.

Product Codes Code


ST10MP ST10M2P ST10SP

Version
1 x 10W Maintained single sided 1 x 10W Maintained double sided 2 x 10W Sustained single sided 2 x 10W Sustained double sided 1 x 10W Maintained single sided theatre 1 x 10W Maintained

Technical
Product Code
ST10MP ST10M2P ST10SP ST10S2P C0 C90 C0 C90 C0 C90 C0 C90

ST10S2P
Classification
E1.25 B1 E2 B1.6 E1.25 B1 E2 C2

2.1 4.2 2.4 5.2 3.1 4.2 2.4 5.2 4.1

2.4 4.2 2.2 5.2 3.1 4.2 2.2 5.2 4.1

Mounting Height in Metres


2.7 4 1.8 5.4 3 4 1.8 5.4 4.1 3 3.6 1.1 5.2 2.8 3.6 1.1 5.2 3.9 3.6 3

STT10MP
4 4.8 4.5 4

ST10M

Accessories
WGWE WGCE
4.8 2.6 4

4.6 1.9 3 4.6 3.3

Wall exit wire guard Ceiling exit wire guard Cantilever bracket Rod suspension white Rod suspension black Pictogram inserts single sided Pictogram inserts double sided Battery 2.4V Nicad, 2 cell lamp 10W Fluorescent

EXCB 99023330 99023360 DIRPPSS DIRPPDS Spare Parts BP2S 99002656

Picto decals included


IP20
3.0kg

Cantilever Bracket EXCB

Max Dim(mm) 395 x 81 x 240

Emergency

Stingray LED
Modern & Stylish Quick connect LED Exit Luminaire complete with Diffuser and Pictogram Legend compliant to Australian Standards AS/NZ2293.

Features
LED long life Exit sign, 50,000hrs Quick slide connect installation Surface mount Wall/Ceiling Maintained operation Viewing distance 24M Complete One Box solution, including diffusers and Picto inserts NiCad high temperature battery system Compliant to Australian Standards AS/NZ2293. Polycarbonate housing and diffuser Polycarbonate housing and diffuser

Applications
Commercial office areas, apartment buildings, Shopping Centres & Arcades, Cinemas & Halls, Caparks etc.

Technical
Product Code STLED C0 C90 C180 Classification D4 D3.2 D4 2.1 7 .2 6.5 7 .2 2.4 7 .3 6.6 7 .3 Mounting Height in Metres 2.7 3 3.6 4 4.5 7 .3 7 .3 7 .2 6.9 6.5 6.6 6.5 6.2 5.8 5.1 7 .3 7 .3 7 .2 6.9 6.5

Product Codes
5 5.8 4.1 5.8 6 3.1 3.1

Code
STLED STTLED

Version
Maintained Maintained Theatre

Accessories
WGWE WGCE EXCB 99023330
Cantilever Bracket EXCB

Wall exit wire guard Ceiling exit wire guard Cantilever bracket Rod suspension white Rod suspension black Pictogram inserts single sided Pictogram inserts double sided

99023360 DIRPPSS DIRPPDS

Picto decals included


IP20 max dim(mm) 395 x 81 x 240

Emergency

3.0kg

Futcha 5 LED
The Futcha 5 is a high performance louvred luminaire for T5 lamp technology, incorporating LED emergency.

Features
Class leading efficiency enabling BCA and Greenstar compliant designs Suitable for Philips 25W ECO lamp Full parabolic high purity aluminium louvres Sturdy low profile body of phosphated steel with high reflectivity Electronic control gear, options for Analogue, DSI and DALI Sensors can be housed in the luminaire Options for soft wiring Plaster mounting with Pierlite Plaster Master Frame 1.5m flex & 3 pin plug as standard Energy efficient high output 3 watt LED / Non Maintained Compliant to AS/NZS2293

Applications
General commercial interiors, office, corridors, retail stores and shopping centres.

Technical
Product Code
FFRLED FFRLEDBK FFSLEDPK FFSLEDAK C0 C90 C0 C90 C0 C90 C0 C90

Classification
D25 D25 D20 D20 D25 D25 D25 D25

FFRLED

C0/C90 D25

2.1 14.2 14.2 13.1 13.1 14.2 14.2 14.2 14.2

2.4 14.7 14.7 13.6 13.6 14.7 14.7 14.7 14.7

2.7 15.3 15.3 14.1 14.1 15.3 15.3 15.3 15.3

3 15.7 15.7 14.5 14.5 15.7 15.7 15.7 15.7

Mounting Height in Metres


3.6 16.5 16.5 15.1 15.1 16.5 16.5 16.5 16.5 4 16.9 16.9 15.5 15.5 16.9 16.9 16.9 16.9 4.5 17.3 17.3 15.8 15.8 17.3 17.3 17.3 17.3

5 17.7 17.7 16.1 16.1 17.7 17.7 17.7 17.7

6 18.1 18.1 16.4 16.4 18.1 18.1 18.1 18.1

8 18.2 18.2 16 16 18.2 18.2 18.2 18.2

10 17.3 17.3 14.5 14.5 17.3 17.3 17.3 17.3

Product Codes Code


F5114MBA4EFA

Dim Version
1 X 14W T5

Power Specifications
Input voltage and tolerance 230V AC +/- 10 Nominal frequency Nominal power Consumption VA Battery Battery operating temp Battery Voltage Battery A/hr rating Battery Charging 50/60Hz 8.3 (16hr) 2.9 NiMH 1700mAh -20C to +70C 4.8V 1700mAhr (run time 2.5hr) Dual rate ~170mA then pulse 1min/30min

(mm)
590 x 590 x 60 590 x 590 x 60 1189 x 590 x 60 1189 x 590 x 60 1189 x 590 x 60 1189 x 590 x 60

F5214MBA4EFA 2 X 14W T5 F5128MBA4EFA 1 X 28W T5 F5228MBA4EFA 2 X 28W T5 F5124MBA4EFA 1 X 24W T5


FFRLED / optical system

F5224MBA4EFA 2 X 24W T5

IP20
5.0kg

Max Dim(mm)

1189 x 294 x 60

Emergency

LED Firefly
Versatile non-maintained LED emergency luminaire compliant to AS/NZS2293.

Features
Energy efficient high output 3 watt LED Easy installation via 3 pin flex and plug Recessed or surface mount options Non corrosive polycarbonate housing and reflector High performance lens system, providing D25/D25 spacing Low power consumption and maintenance Fully self-contained control circuit, complete with flex and plug Optional DALI maintained systems available Suspension kit and tamper proof options available Compliant to AS/NZS2293 Circuit rated system life 50 000 hrs Black theatre options available

Tough polycarbonate body

Applications
Commercial and interior applications, coastal environments, apartments, shopping centres, hospitality, prisons and hospitals.

Product Codes Code Version

Dim (mm)

Mass (kg)

114 mm Cutout non-maintained recessed model FFRLED 3W White 140 x 48 140 x 48 140 x 48 0.35 0.35 0.35 0.48 0.90 0.90 FFRLEDBK 3W Black

Technical
Product Code
FFRLED FFRLEDBK FFSLEDPK FFSLEDAK FFRLEM C0 C90 C0 C90 C0 C90 C0 C90 C0 C90

114 mm Cutout maintained recessed model


Classification
C0 D25 C90 D25 CO D20 C90 D20 C0 D25 C90 D25 C0 D25 C90 D25 CO D20 C90 D20

2.1 14.2 14.2 13.1 13.1 14.2 14.2 14.2 14.2 13.1 13.1

2.4 14.7 14.7 13.6 13.6 14.7 14.7 14.7 14.7 13.6 13.6

2.7 15.3 15.3 14.1 14.1 15.3 15.3 15.3 15.3 14.1 14.1

3 15.7 15.7 14.5 14.5 15.7 15.7 15.7 15.7 14.5 14.5

Mounting Height in Metres


3.6 16.5 16.5 15.1 15.1 16.5 16.5 16.5 16.5 15.1 15.1 4 16.9 16.9 15.5 15.5 16.9 16.9 16.9 16.9 15.5 15.5 4.5 17.3 17.3 15.8 15.8 17.3 17.3 17.3 17.3 15.8 15.8

FFRLEM
5 17.7 17.7 16.1 16.1 17.7 17.7 17.7 17.7 16.1 16.1 6 18.1 18.1 16.4 16.4 18.1 18.1 18.1 18.1 16.4 16.4 8 18.2 18.2 16 16 18.2 18.2 18.2 18.2 16 16 10 17.3 17.3 14.5 14.5 17.3 17.3 17.3 17.3 14.5 14.5

3W White recessed

Non-maintained Surface mount complete FFSLEDPK 3W White Polycarbonate 159 x 85 FFSLEDAK 3W White Alloy Maintained surface moutnt complete FFRLEMAK 3W Surf. Mt Alloy Can Mtd 159 x 85 159 x 85

Accessories
FFLEDVK 99023330 Vandal resistant kit White Pole Suspension kit 1600mm Black Pole Suspension kit 1200mm Security screws (3 pack) for alloy SM CAN option TORX SS Screw (3 pack) for FFSLEDAK FFSLEDPB Surface Mount Polycarbonate black can only

FFRLED

C0/C90 D25

Power Specifications
Input voltage and tolerance 230V AC +/- 10 Nominal frequency Nominal power Consumption VA Battery 50/60Hz 8.3 (16hr) 2.9 NiMH 1700mAh Battery operating temp Battery Voltage Battery A/hr rating Battery Charging -20C to +70C 4.8V 1700mAhr (run time 2.5hr) Dual rate ~170mA then pulse 1min/30min

99023360 99015840 99023660


IP20 max dim(mm)
0.90kg

FFSLEDDISC Suspension cover disc

10

Emergency

159 x 85

FFSLEDPK / Surface mount white

FFRLEDBK / FFSLEDPB Black surface mount option

99023330 White Pole Suspension kit 1600mm 99023360 Black Pole Suspension kit 1200mm

FFLEDVK / Recessed vandal option

Emergency

11

Firefly
Versatile non-maintained emergency luminaire providing an economical solution for conventional commercial applications.

Features
Lamp 8 watt tungsten halogen Steel white polyester coated housing with highly reflective white powder coat finish Mouse trap mounting spring clips Non-maintained operation All recessed models are supplied with flex and plug Filament failure indication standard on all models Recessed or surface mounted Small (85mm) or large (140mm) reflector heads available Compliant with AS/NZS2293

Applications
All commercial and interior applications, apartments, shopping centres, hospitality, prisons and hospitals.

Product Codes Code Version

Dim (mm)

Non-maintained recessed reflector FF608 FF608TH FFC608 FF608S FF608SLR FF608CR FF608LA 8W T.H. NiMH 8W T.H. NiMH - Black theatre 8W T.H. NiMH 8W T.H. NiMH battery, split pack 8W T.H. NiMH battery, split pack 8W T.H. Weatherproof / Coolroom 8W T.H. Lead acid - reflector 8W T.H. NiMH 140 140 85 85 140 140 140 200 x 46 200 x 46

Technical

Non-maintained surface mount


Product Code
FF608 FFC608 FF608S FF608CR FF608LA FFSQ608 C0 C90 C0 C90 C0 C90 C0 C90 C0 C90 C0 C90

Classification
D12.5 D12.5 D12.5 D12.5 D12.5 D12.5 D10 C10 D10 C10 D10 C10

2.1 11.1 11.1 11.1 11.1 11.1 11.1 10.2 7.3 10.2 7.3 10.2 12.1

2.4 11.5 11.5 11.5 11.5 11.5 11.5 10.6 7.7 10.6 7.7 10.6 12.6

2.7 11.8 11.8 11.8 11.8 11.8 11.8 10.9 8 10.9 8 10.9 13.4

3 12.1 12.1 12.1 12.1 12.1 12.1 11.1 8.3 11.1 8.3 11.1 13.1

Mounting Height in Metres


3.6 12.5 12.5 12.5 12.5 12.5 12.5 11.4 8.8 11.4 8.8 11.4 13.9 4 12.7 12.7 12.7 12.7 12.7 12.7 11.5 9 11.5 9 11.5 14.1 4.5 12.9 12.9 12.9 12.9 12.9 12.9 11.6 9.1 11.6 9.1 11.6 14.6

FFSQ608
5 13 13 13 13 13 13 11.6 9.2 11.6 9.2 11.6 14.6 6 12.8 12.8 12.8 12.8 12.8 12.8 11.2 9.1 11.2 9.1 11.2 14.6 8 11.3 11.3 11.3 11.3 11.3 11.3 10.3 7.5 10.3 7.5 10.3 13.8 10 7.6 7.6 7.6 7.6 7.6 7.6 8.9 8.9 8.9 11.5

FFSQ6085P1 8W T.H. NiMH Black

Accessories
Non-maintained recessed reflector FF608 8W T.H. NiMH 140 FF608TH 8W T.H. NiMH - Black theatre 140 FFC608 8W T.H. NiMH 85 FF608S 8W T.H. NiMH battery, split pack 85 FF608SLR 8W T.H. NiMH battery, split pack 140 FF608CR 8W T.H. Weatherproof / Coolroom 140 FF608LA 8W T.H. Lead acid - reflector 140

12

IP20

Emergency

max dim(mm)
0.40kg

200 x 46

DOT 1250 - Emergency


DOT 1250/EM is a high performance, energy efficient downlight with emergency capabilities.

Features
Easy to install, including accessories Maintained emergency circuit Easy downlight removal system High temperature thermo plastic control gear housing High temperature lampholder, passivated, heavy gauge pressed steel mounting legs High purity, post anodised bright aluminium reflector Electronic control gear Energy efficient 2 x 26W 4 pin Compact fluorescent lamps Complete with flex and plug

Applications
Offices, boardrooms, foyers and reception areas, retail outlets. medical centres and hospitals.

Technical
Product Code
1250/02/ECG/EM-DOT1250 C0 C90 C180

Classification
A8 A10 A6.3 2.1 4.8 5 4.5 2.4 5.1 5.4 4.8 2.7 5.4 5.7 5 3 5.6 6 5.2

Mounting Height in Metres


3.6 5.9 6.4 5.4 4 6.1 6.6 5.5 4.5 6.2 6.8 5.6 5 6.3 7 5.5 6 6.1 7 5

Emergency Option available - tested to AS/NZS 2293.3.1995 Emergency Classification in accordance with Appendix C Section 3:- CO A8 C90 A10 IES file available C180 A6.3 on request
Remote Control Gear

128mm

Product Codes Code Version

175mm dia. hole cut out

1250/02/ECG/EM-DOT1250 2 x 26W Maintained


IP20
0.9kg

Max Dim(mm) 192 x 128

Emergency

13

Nipper Emergency
Versatile fluorescent batten with multiple options designed for use in general commercial interiors.

Features
Energy efficient lamps 18W and 36W fluorescent End to end mounting Maintained, Non-maintained and Sustained available Quarter turn quick release reflector and Quick release diffuser end cap Large 3 way tunnel terminal block Rolled cable entry - no grommets required Wide body version width is designed to cover flush mount junction box installations Wire guards, reflectors and industrial options available Compliant to AS/NZS2293

Applications
Domestic, retail stores and outlets, garages, food processing areas, change rooms and general commercial areas.

Product Codes Code


Bare Batten PN218M PN136M PN236M PN118NM PN136NM Diffused Batten PND218M 2 x 18W Maintained 1 x 36W Maintained 2 x 36W Combined maintained 1 x 18W Non-maintained 1 x 36W Non-maintained PND136M 2 x 18W Combined maintained 2 x 36W Combined maintained 2 x 36W Maintained 1 x 18W Non-maintained 1 x 36W Non-maintained

Version

Technical

Product Code
PN118NM PN218M PN136NM PN136M PN236M C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180

Classification
D32 C32 D32 C32 D25 D40 C40 D40 C40 D40 C40 D40

2.1 15.4 10 15.4 10 14.2 16.7 10.6 16.7 10.6 16.7 10.6 16.7

2.4 16.1 10.7 16.1 10.7 14.7 17.4 11.3 17.4 11.3 17.4 11.3 17.4

2.7 16.7 11.3 16.7 11.3 15.3 18 11 18 11 18 11 18

3 17.2 11.8 17.2 11.8 15.7 18.6 12.6 18.6 12.6 18.6 12.6 18.6

Mounting Height in Metres


3.6 18 12.8 18 12.8 16.5 19.6 13.6 19.6 13.6 19.6 13.6 19.6 4 18.5 13.4 18.5 13.4 16.9 20.1 14.3 20.1 14.3 20.1 14.3 20.1 4.5 19.1 14 19.1 14 17.3 20.8 15 20.8 15 20.8 15 20.8

5 19.5 14.5 19.5 14.5 17.7 21.3 15.6 21.3 15.6 21.3 15.6 21.3

6 20.2 15.4 20.2 15.4 18.1 22.1 16.6 22.1 16.6 22.1 16.6 22.1

8 20.7 16.4 20.7 16.4 18.2 23 17.9 23 17.9 23 17.9 23

10 20.3 16.5 20.3 16.5 17.3 23.1 18.5 23.1 18.5 23.1 18.5 23.1

PND236M PND118NM PND136NM

Accessories
Wire Guards Diffuser Kits Spare Parts: BP4S Battery P4S6 Battery 4.8V NiCad, 4cell 4.8V NiMH, 4cell (suits PN118NM) Available Available

14

IP20

Emergency

max dim(mm)
3.4kg

1229 x 52 x 92

Emergency

15

High 5 Emergency
Square sided batten with energy efficient T5 lamp technology and emergency lighting capabilities.

Features
High performing photometric distribution in either bare or diffused options The body is a cold rolled steel channel, finished in white polyester powder coat with UV stabilised polycarbonate plastic end caps Unique diffuser removal system for easy lamp change Quarter turn quick release reflector Large 3 way tunnel terminal block Rolled cable entry no grommets required Energy efficient T5 lamp fluorescent circuit Compliant to AS/NZS2293 Wide body assembly is designed to cover flush mount junction box installations Optional light movement and IR sensor capabilities True end to end mounting possible with knockouts for wiring Optional DALI maintained systems available

Applications
General commercial interiors, factories, warehouses, shopping centres, stairwells and interior carparks.t Diffused model

Product Codes Code


HI5228BE4M

Technical
Product Code
HI5114B/4N HI5114BE4M HI5214BE4MX1 HI5128BE4N HI5128BE4M HI5228BE4M HI5228BE4S C0 C90 C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180 C0 C90 180

Version
28W Bare, Maintained 28W Bare, Sustained 28W, Diffused Maintained 28W Diffused, Maintained 28W, Diffused, Sustained 28W 28W Bare, Maintained 28W Bare, Non-Maintained 28W Diffused, Maintained 28W, Diffused, Non-Maintained 4W, Bare, Non-Maintained 14W, Diffused, Non-Maintained

Classification
D32 C32 D32 C32 D32 C32 D32 D160 D40 D160 D40 D100 D25 D100 D100 D25 D100

2.1 15.4 10 15.4 10 15.4 10 15.4 26.6 16.7 26.6 16.7 22.7 14.2 22.7 22.7 14.2 22.7

2.4 16.1 10.7 16.1 10.7 16.1 10.7 16.1 27.8 17.4 27.8 17.4 23.7 14.7 23.7 23.7 14.7 23.7

2.7 16.7 11.3 16.7 11.3 16.7 11.3 16.7 28.9 18 28.9 18 24.6 15.3 24.6 24.6 15.3 24.6

Mounting Height in Metres - Bare


3 17.2 11.8 17.2 11.8 17.2 11.8 17.2 29.9 18.6 29.9 18.6 25.5 15.7 25.5 25.5 15.7 25.5 3.6 18 12.8 18 12.8 18 12.8 18 31.7 19.6 31.7 19.6 27 16.5 27 27 16.5 27 4 18.5 13.4 18.5 13.4 18.5 13.4 18.5 32.8 20.1 32.8 20.1 27.9 16.9 27.9 27.9 16.9 27.9

4.5 19.1 14 19.1 14 19.1 14 19.1 34 20.8 34 20.8 28.9 17.3 28.9 28.9 17.3 28.9

5 19.5 14.5 19.5 14.5 19.5 14.5 19.5 35.1 21.3 35.1 21.3 29.8 17.7 29.8 29.8 17.7 29.8

6 20.2 15.4 20.2 15.4 20.2 15.4 20.2 37.1 22.1 37.1 22.1 31.4 18.1 31.4 31.4 18.1 31.4

8 20.7 16.4 20.7 16.4 20.7 16.4 20.7 40.24 23 40.24 23 33.7 18.2 33.7 33.7 18.2 33.7

10 20.3 16.5 20.3 16.5 20.3 16.5 20.3 42.5 23.1 42.5 23.1 35.3 17.3 35.3 35.3 17.3 35.3

HI5228BE4S HI5228DE4M HI5228D/4N HI5228DE4S HI5128BE4M HI5128BE4N HI5128DE4M HI5128D/4N HI5114B/4N HI5114D/4N

Product Code
HI5114DE4M HI5214DE4MX1 HI5128D/4N C0 C90 C0 C90 180 C0 C90 C0

Classification
D32 C32 D32 C32 D32 D160 D40 D160

16

Emergency

HI5128DE4M

2.1 15.4 10 15.4 10 15.4 26.6 16.7 26.6

2.4 16.1 10.7 16.1 10.7 16.1 27.8 17.4 27.8

2.7 16.7 11.3 16.7 11.3 16.7 28.9 18 28.9

Mounting Height in Metres - Diffused


3 17.2 11.8 17.2 11.8 17.2 29.9 18.6 29.9 3.6 18 12.8 18 IP20 12.8 18 31.7 19.6 31.7 4 18.5 13.4 18.5 13.4 18.5 4.0kg 32.8 20.1 32.8

Hi5214BE4MX1 14W, Bare, Combined- Maintained


6 20.2 15.4 20.2 15.4 20.2 37.1 22.1 37.1 8 20.7 16.4 20.7 16.4 20.7 40.24 23 40.24 10 20.3 16.5 20.3 16.5 20.3 42.5 23.1 42.5

4.5 5 19.1 19.5 14 14.5 19.1 19.5 14.5 max14 dim(mm) 19.1 19.5 122934 x 102 x35.1 101 20.8 21.3 34 35.1

HI5214DE4MX1 14W, Diffused, Combined- Maintained

Product Code
HI5114B/4N HI5114BE4M HI5214BE4MX1 HI5128BE4N HI5128BE4M HI5228BE4M HI5228BE4S C0 C90 C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180 C0 C90 180

Classification
D32 C32 D32 C32 D32 C32 D32 D160 D40 D160 D40 D100 D25 D100 D100 D25 D100

Technical

2.1 15.4 10 15.4 10 15.4 10 15.4 26.6 16.7 26.6 16.7 22.7 14.2 22.7 22.7 14.2 22.7

2.4 16.1 10.7 16.1 10.7 16.1 10.7 16.1 27.8 17.4 27.8 17.4 23.7 14.7 23.7 23.7 14.7 23.7

2.7 16.7 11.3 16.7 11.3 16.7 11.3 16.7 28.9 18 28.9 18 24.6 15.3 24.6 24.6 15.3 24.6

Mounting Height in Metres - Bare


3 17.2 11.8 17.2 11.8 17.2 11.8 17.2 29.9 18.6 29.9 18.6 25.5 15.7 25.5 25.5 15.7 25.5 3.6 18 12.8 18 12.8 18 12.8 18 31.7 19.6 31.7 19.6 27 16.5 27 27 16.5 27 4 18.5 13.4 18.5 13.4 18.5 13.4 18.5 32.8 20.1 32.8 20.1 27.9 16.9 27.9 27.9 16.9 27.9

4.5 19.1 14 19.1 14 19.1 14 19.1 34 20.8 34 20.8 28.9 17.3 28.9 28.9 17.3 28.9

5 19.5 14.5 19.5 14.5 19.5 14.5 19.5 35.1 21.3 35.1 21.3 29.8 17.7 29.8 29.8 17.7 29.8

6 20.2 15.4 20.2 15.4 20.2 15.4 20.2 37.1 22.1 37.1 22.1 31.4 18.1 31.4 31.4 18.1 31.4

8 20.7 16.4 20.7 16.4 20.7 16.4 20.7 40.24 23 40.24 23 33.7 18.2 33.7 33.7 18.2 33.7

10 20.3 16.5 20.3 16.5 20.3 16.5 20.3 42.5 23.1 42.5 23.1 35.3 17.3 35.3 35.3 17.3 35.3

Product Code
HI5114DE4M HI5214DE4MX1 HI5128D/4N HI5128DE4M HI5228D/4M HI5228DE4S C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180 C0 C90 180

Classification
D32 C32 D32 C32 D32 D160 D40 D160 D40 D125 D40 D160 D125 D40 D160

2.1 15.4 10 15.4 10 15.4 26.6 16.7 26.6 16.7 24.5 16.7 26.6 24.5 16.7 26.6

2.4 16.1 10.7 16.1 10.7 16.1 27.8 17.4 27.8 17.4 25.6 17.4 27.8 25.6 17.4 27.8

2.7 16.7 11.3 16.7 11.3 16.7 28.9 18 28.9 18 27.5 18 28.9 27.5 18 28.9

Mounting Height in Metres - Diffused


3 17.2 11.8 17.2 11.8 17.2 29.9 18.6 29.9 18.6 28.3 18.6 29.9 28.3 18.6 29.9 3.6 18 12.8 18 12.8 18 31.7 19.6 31.7 19.6 30.1 19.6 31.7 30.1 19.6 31.7 4 18.5 13.4 18.5 13.4 18.5 32.8 20.1 32.8 20.1 31.2 20.1 32.8 31.2 20.1 32.8

4.5 19.1 14 19.1 14 19.1 34 20.8 34 20.8 32 20.8 34 32 20.8 34

5 19.5 14.5 19.5 14.5 19.5 35.1 21.3 35.1 21.3 34 21.3 35.1 34 21.3 35.1

6 20.2 15.4 20.2 15.4 20.2 37.1 22.1 37.1 22.1 35.5 22.1 37.1 35.5 22.1 37.1

8 20.7 16.4 20.7 16.4 20.7 40.24 23 40.24 23 37.8 23 40.24 37.8 23 40.24

10 20.3 16.5 20.3 16.5 20.3 42.5 23.1 42.5 23.1 40.8 23.1 42.5 40.8 23.1 42.5

Emergency

17

Regency Bare
Premium square sided bare batten, wide body, finished in white powder coat with white ABS end caps allowing for easy end to end mounting.

Features
Energy efficient T5 and T8 fluorescent lamps End to End mounting Roll formed steel channel in white polyester powder coat housing Maintained, Combined Maintained, Combined NonMaintained or Non-Maintained Lamp holder end caps have knock outs with moulding provision in the diffuser end caps to enable wiring and flush end to end mounting Compliant to AS/NZS2293

Applications
Commercial interiors, retail, carparks, passageways, light industrial warehousing. Dim (mm) 1 x 18W T8 2 x 18W T8 1 x 36W T8 2 x 36W T8 1 x 58W T8 2 x 58W T8 620 x 105 x 92 620 x 105 x 92 1228 x 105 x 92 1228 x 105 x 92 1529 x 105 x 92 1529 x 105 x 92

Product Codes Code


RY118M RY218M RY218S RY136M RY236S RY158M
5 19.5 14.5 19.5 14.5 19.5 14.5 17.7 19.5 14.5 17.7 21.3 15.6 21.3 15.6 21.3 15.6 21.3 21.3 15.6 21.3 27.5 19.1 23.2 20.4 6 20.2 15.4 20.2 15.4 20.2 15.4 18.1 20.2 15.4 18.1 22.1 16.6 22.1 16.6 22.1 16.6 22.1 22.1 16.6 22.1 28.9 20.7 24.2 22.1 8 20.7 16.4 20.7 16.4 20.7 16.4 18.2 20.7 16.4 18.2 23 17.9 23 17.9 23 17.9 23 23 17.9 23 30.9 23.6 25.4 24.8 10 20.3 16.5 20.3 16.5 20.3 16.5 17.3 20.3 16.5 17.3 23.1 18.5 23.1 18.5 23.1 18.5 23.1 23.1 18.5 23.1 32.1 24.7 25.9 26.7

Version
1 X 18W Maintained 2 x 18W Combined-Maintained 2 x 18W Sustained 1 x 36W Maintained 2 x 36W Sustained 1 x 58W Maintained 2 x 58W Combined Maintained 1 x 28W T5 Maintained 2 x 28W T5 Maintained 2 x 28W T5 Sustained

RY118NM 1 x 18W Non-Maintained

Technical Technical Product Code


RY118M RY118NM RY218M RY218S RY136M RY136NM RY236M RY236S RY158M RY258M C0 C90 C0 C90 C0 C90 180 C0 C90 180 C0 C90 C0 C90 C0 C90 180 C0 C90 180 C0 C90 C0 C90

Classification
D32 C32 D32 C32 D32 C32 D25 D32 C32 D25 D40 C40 D40 C40 D40 C40 D40 D40 C40 D40 D80 C80 D50 C100

2.1 15.4 10 15.4 10 15.4 10 14.2 15.4 10 14.2 16.7 10.6 16.7 10.6 16.7 10.6 16.7 16.7 10.6 16.7 21.1 12.7 18 13.4

2.4 16.1 10.7 16.1 10.7 16.1 10.7 14.7 16.1 10.7 14.7 17.4 11.3 17.4 11.3 17.4 11.3 17.4 17.4 11.3 17.4 22 13.5 18.7 14.3

2.7 16.7 11.3 16.7 11.3 16.7 11.3 15.3 16.7 11.3 15.3 18 11 18 11 18 11 18 18 11 18 22.8 14.4 19.4 15.2

3 17.2 11.8 17.2 11.8 17.2 11.8 15.7 17.2 11.8 15.7 18.6 12.6 18.6 12.6 18.6 12.6 18.6 18.6 12.6 18.6 23.6 15.1 20.1 16

Mounting Height in Metres


3.6 18 12.8 18 12.8 18 12.8 16.5 18 12.8 16.5 19.6 13.6 19.6 13.6 19.6 13.6 19.6 19.6 13.6 19.6 25 16.5 21.2 17.5 4 18.5 13.4 18.5 13.4 18.5 13.4 16.9 18.5 13.4 16.9 20.1 14.3 20.1 14.3 20.1 14.3 20.1 20.1 14.3 20.1 25.8 17.3 21.8 18.4 4.5 19.1 14 19.1 14 19.1 14 17.3 19.1 14 17.3 20.8 15 20.8 15 20.8 15 20.8 20.8 15 20.8 26.7 18.3 22.5 19.4

RY158NM 1 x 58W Non-Maintained RY258M RY128M RY228M RY228S

RY128NM 1 x 28W T5 Non-Maintained

Accessories
White powder coated wire guard PHWG218 PHWG236 PHWG258 BP4S BP8S2 suits RY118/218 suits RY136/236 suits RY158/258 4.8V Nicad, 4 cell to suit 18W/36W/58W 9.6V NiCad, 8cell to suit 28W and 35W

Replacement Batteries

18

IP20

Emergency

max dim(mm)
3.1kg

1227 x 101

Regency Diffused
Premium square sided diffused batten, wide body, finished in white powder coat with white ABS end caps allowing for easy end to end mounting.

Features
Energy efficient T5 and T8 fluorescent lamps Tough Y12 acrylic diamond pattern diffuser retained by white polycarbonate end caps End to end mounting, roll formed steel channel in white polyester powder coat housing Maintained, combined maintained, combined nonmaintained or non-maintained Compliant to AS/NZS2293 Lamp holder end caps have knock outs with moulding provision to enable wiring and flush end to end mounting

Applications
Commercial interiors, retail, carparks, passageways, and light industrial warehousing. Dim (mm) 1 x 18W T8 2 x 18W T8 1 x 36W T8 2 x 36W T8 1 x 58W T8 2 x 58W T8 624 x 108 x 101 624 x 108 x 101 1232 x 108 x 101 1232 x 108 x 101 1533 x 108 x 101 1533 x 108 x 101 RYD118M 1 X 18W Maintained RYD118NM 1 x 18W Non-Maintained RYD218M 2 x 18W Combined-Maintained 2 x 18W Sustained 2 x 36W Sustained RYD218S
Classification
C0 C90 C0 C90 C0 C90 180 C0 C90 180 C0 C90 C0 C90 C0 C90 180 C0 C90 180 C0 C90 D25 C20 D25 C20 D32 C20 D16 D32 C20 D16 D40 C32 D40 C32 D50 C40 D25 D50 C40 D25 D80 C50

Product Codes Code Version

Technical
Product Code
RYD118M RYD118NM RYD218M RYD218S RYD136M RYD136NM RYD236M RYD236S RYD158M 2.1 14.2 8.9 14.2 8.9 15.4 8.9 12.1 15.4 8.9 12.1 16.7 10 16.7 10 18 10.6 14.2 18 10.6 14.2 21.1 11.3 2.4 14.7 9.4 14.7 9.4 16.1 9.4 12.6 16.1 9.4 12.6 17.4 10.7 17.4 10.7 18.7 11.3 14.7 18.7 11.3 14.7 22 12 2.7 15.3 9.9 15.3 9.9 16.7 9.9 13.4 16.7 9.9 13.4 18 11.3 18 11.3 19.4 11 15.3 19.4 11 15.3 22.8 11.8 3 15.7 10.3 15.7 10.3 17.2 10.3 13.1 17.2 10.3 13.1 18.6 11.8 18.6 11.8 20.1 12.6 15.7 20.1 12.6 15.7 23.6 13.4

Mounting Height in Metres


3.6 16.5 11.1 16.5 11.1 18 11.1 13.9 18 11.1 13.9 19.6 12.8 19.6 12.8 21.2 13.6 16.5 21.2 13.6 16.5 25 14.5 4 16.9 11.5 16.9 11.5 18.5 11.5 14.1 18.5 11.5 14.1 20.1 13.4 20.1 13.4 21.8 14.3 16.9 21.8 14.3 16.9 25.8 15.2 4.5 17.3 12 17.3 12 19.1 12 14.6 19.1 12 14.6 20.8 14 20.8 14 22.5 15 17.3 22.5 15 17.3 26.7 16

RYD136M 1 x 36W Maintained


5 17.7 12.3 17.7 12.3 19.5 12.3 14.6 19.5 12.3 14.6 21.3 14.5 21.3 14.5 23.2 15.6 17.7 23.2 15.6 17.7 27.5 16.7 6 18.1 12.8 18.1 12.8 20.2 12.8 14.6 20.2 12.8 14.6 22.1 15.4 22.1 15.4 24.2 16.6 18.1 24.2 16.6 18.1 28.9 17.9 8 18.2 13 18.2 13 20.7 13 13.8 20.7 13 13.8 23 16.4 23 16.4 25.4 17.9 18.2 25.4 17.9 18.2 30.9 17.9 10 17.3 12 17.3 12 20.3 12 11.5 20.3 12 11.5 23.1 16.5 23.1 16.5 25.9 18.5 17.3 25.9 18.5 17.3 32.1 18.5

RYD236S

RYD158M 1 x 58W Maintained RYD158NM 1 x 58W Non-Maintained RYD258M 2 x 58W Combined Maintained RYD128M 1 x 28W T5 Maintained RYD128NM 1 x 28W T5 Non-Maintained RYD228M 2 x 28W T5 Maintained RYD228S 2 x 28W T5 Sustained

Accessories
Replacement Batteries BP4S BP8S 4.8V Nicad, 4 cell to suit 18W/36W/58W 2 9.6V NiCad, 8cell to suit 28W and 35W

IP20
3.8kg

Max Dim(mm) 1227 x 108 x 101

Emergency

19

Deluxe Bare Batten


Single and twin 36W bare tube fluorescent battens designed for ease of installation, and maintenance. The slim line body profile creates an elegant yet simple design.

Features
Energy efficient lamp 36W fluorescent Slimline profile, powder coated non-discolouring white housing Durable polycarbonate non-discolouring end caps with easy replaceable built in lamp holders Captive cover plate 1/4 turn clip Maintained, non-maintained and combined maintained circuits available Wire guards available Compliant to AS/NZS2293

Applications
General commercial interiors, corridors, carparks, and warehousing.

Technical
Product Codes Code
Product Code
DB136M DB136MEL
DB236MEL DB136NM DB136NM DB236M

Version

Classification
C0 C90 C0 C90 C0 C90 C180 D40 C40 D40 C40 D50 C50 D40

2.1 16.7 10.6 16.7 10.6 18 11.3 16.7

2.4 17.4 11.3 17.4 11.3 18.7 12 17.4

2.7 18 11 18 11 19.4 11.8 18

3 18.6 12.6 18.6 12.6 20.1 13.4 18.6

Mounting Height in Metres


3.6 19.6 13.6 19.6 13.6 21.2 14.5 19.6 4 20.1 14.3 20.1 14.3 21.8 15.2 20.1 4.5 20.8 15 20.8 15 22.5 16 20.8

5 21.3 15.6 21.3 15.6 23.2 16.7 21.3

6 22.1 16.6 22.1 16.6 24.2 17.9 22.1

8 23 17.9 23 17.9 25.4 17.9 23

10 23.1 18.5 23.1 18.5 25.9 18.5 23.1

DB136MEL 1 x 36W Maintained DB236MEL 2x 36W Maintained DB136NM 1 x 36W Non-maintained

Accessories
White powder coat wire guards UNBWG136 suit DB136 UNBWG236 suit DB236 Replacement Batteries BP4S BP4SNL 4.8V Nicad, 4 cell to suit DB136NM 4.8V NiCad, 4cell

Dim (mm) 1 x 36W T8 2 x 36W T8 1228 x 50 x 90 1228 x 68 x 90

20

IP20

Emergency

max dim(mm)
4.0kg

1227 x 68 x 90

Deluxe Diffused
Single and twin 36 watt diffused fluorescent battens designed for ease of installation, relamping and maintenance.

Features
Energy efficient lamp 36W fluorescent Variable rate charge Slimline profile, powder coated non-discolouring white housing Durable polycarbonate non-discolouring lamp holder end caps with easy replaceable built in lamp holders Tough Y12 diamond patterned acrylic diffuser retained by polycarbonate end caps with unique clip design allowing true end to end mounting Captive cover plate 1/4 turn clip Maintained, combined maintained, non-maintained and sustained circuits available Compliant to AS/NZ2293

Applications
General commercial interiors, retail stores, shopping centres and warehousing.

Technical

Product Code
DBD136MEL DBD136M DBD136NM DBD136NM DBD236MEL DBD236M

Classification
C0 C90 C0 C90 C0 C90 180 D50 C25 D50 C25 D63 C40 D32

2.1 18 9.4 18 9.4 19.4 10.6 15.4

2.4 18.7 10 18.7 10 20.3 11.3 16.1

2.7 19.4 10.5 19.4 10.5 21.2 11 16.7

3 20.1 11 20.1 11 21.8 12.6 17.2

Mounting Height in Metres


3.6 21.2 11.9 21.2 11.9 23 13.6 18 4 21.8 12.4 21.8 12.4 23.7 14.3 18.5 4.5 22.5 12.9 22.5 12.9 24.5 15 19.1

5 23.2 13.4 23.2 13.4 25.2 15.6 19.5

6 24.2 14 24.2 14 26.4 16.6 20.2

8 25.4 14.6 25.4 14.6 28.1 17.9 20.7

10 25.9 14.2 25.9 14.2 28.9 18.5 20.3

Product Codes Code


DBD136MEL DBD136NM DBD236MEL DBD236SEL

Version
1 x 36W Maintained 1 x 36W Non-maintained 2 x 36W Maintained 2 x 36W Sustained

Dim (mm) 1 x 36W T8 2 x 36W T8 1229 x 86 x 110 1229 x 145 x 110

Accessories
Replacement Batteries BP4S 4.8V BP4SNL Battery Nicad, 4 cell to suit DBD136NM 4.8V NiCad, 4cell

IP20
4.5kg

Max Dim(mm) 1229 x 145 x 110

Emergency

21

Unilux
Surface mounted emergency fluorescent luminaire designed with energy efficient T8 technology in compliance with AS/NZS2293.

Features
Energy efficient lamp 36W fluorescent White powder coated steel body Injection molded prismatic acrylic lens diffuser Quick release access clips Combined maintained operation High performance prismatic lens Compliant with AS/NZS2293 Low profile body design

Applications
Low glare applications, schools, hospitals, TAFEs, universities, libraries, retail stores, hospitals, banks, general office areas.

Technical
Product Code
EP236M C0 C90 C180

Classification
D25 C40 C50

2.1 14.2 10.6 11.3

2.4 14.7 11.3 12

2.7 15.3 11 11.8

3 15.7 12.6 13.4

Mounting Height in Metres


3.6 16.5 13.6 14.5 4 16.9 14.3 15.2 4.5 17.3 15 16

Product Codes
5 17.7 15.6 16.7 6 18.1 16.6 17.9 8 18.2 17.9 17.9 10 17.3 18.5 18.5

Code
EP236M

Version
2 x 36W Combined maintained

Accessories
Spare Parts:

276 100

1265

99001550 BP4S

Replacement diffuser Battery 4.8V NiCad, 4cell

22

IP20

Emergency

max dim(mm)
6.2kg

1265 x 100 x 276

ET Troffer
An economical solution using a variety of lens and louvre options providing a smooth and uniform light distribution.

Features
Energy efficient lamp 36W fluorescent included Recessed mount T-Bar system Powder coated white steel body Y12 Prismatic lens or optional Y19 Combined maintained operation Simple to install 1.5m flex and plug, flat earth Provisions made for tandem mounting Suitable for plaster mounting using the Pierlite plaster master frame Compliant to AS/NZS2293

Applications
Commercial interiors, office space and shopping centres.

Technical
Product Code
ETT236M C0 C90 C180

Classification
C32 C50 C80

2.1 10 11.3 12.7

2.4 10.7 12 13.5

2.7 11.3 11.8 14.4

3 11.8 13.4 15.1

Mounting Height in Metres


3.6 12.8 14.5 16.5 4 13.4 15.2 17.3 4.5 14 16 18.3

5 14.5 16.7 19.1

6 15.4 17.9 20.7

8 16.4 17.9 23

10 16.5 18.5 24.7

Product Codes Code


ET236M

Version
2 x 36W Combined Maintained Recessed, Less lamp andY12 Diffuser

288 97

1240

Accessories
98047100 99003424 HFRM1200X300K12 HFRM1200X300K19 Spare Parts: BP4S Battery 4.8V Nicad, 4 cell K12 Prismatic diffuser Y19 Prismatic diffuser Y12 Hinged frame diffuser panel Y19 Hinged frame diffuser panel

IP20
4.3kg

Max Dim(mm) 1240 x 97 x 288

Emergency

23

TR322
A simple yet stylish non-maintained emergency bulkhead designed for interior and protected exterior use applications.

Features
Energy efficient lamp 22W circular fluorescent Surface Mount - wall / ceiling options UV stabilised opal polycarbonate housing and diffuser Mains only versions available Ideal for apartment corridors, requiring both general and emergency lighting matched luminaires Compliant with AS/NZS2293

Applications
Interior and covered exterior use, stairwells & apartment buildings, under eaves and awnings.

Technical
Product Code
TR322NM C0 C90

Classification
D10 D10

2.1 10.2 10.2

2.4 10.6 10.6

2.7 10.9 10.9

3 11.1 11.1

Mounting Height in Metres


3.6 11.4 11.4 4 11.5 11.5 4.5 11.6 11.6

5 11.6 11.6

6 11.2 11.2

8 10.3 10.3

10 8.9 8.9

Product Codes Code


TR322NM TR322

Version
1 x 22W Non-maintained 1 x 22W Mains operation only

Accessories
Spare Parts: BP4S2 Battery 4.8V Nicad, 4 cell
IP43 max dim(mm)
1.4kg

24

Emergency

250 x 103

Emergency

25

Condo
Classic styled luminaire designed for commercial applications in either maintained configuration or mains only.

Features
Lamp 32W circular fluorescent included Surface mount wall/ ceiling options Strong formed steel housing Highly reflective white powder coat finish Thick opal acrylic lens with wide distribution Mains only or Maintained operation Variable rate charging (variable rate charging) Ideal for apartment corridors, requiring both general and emergency lighting Compliant to AS/NZS2293

Applications
Interior, commercial, apartments, corridors, stairwells.

Technical
Product Code
CD32M C0 C90

Classification
D16 D16

2.1 12.1 12.1

2.4 12.6 12.6

2.7 13.4 13.4

3 13.1 13.1

Mounting Height in Metres


3.6 13.9 13.9 4 14.1 14.1 4.5 14.6 14.6

5 14.6 14.6

6 14.6 14.6

8 13.8 13.8

10 11.5 11.5

Durable formed steel housing

Product Codes Code


CD32M CD32

Version
1 x 32W Maintained c/w circular lamp 1 x 32W Mains operation only

Accessories
Spare parts: P4S62 99002671
IP40 max dim(mm)
2.0kg

Battery 4.8V NiMh, 4 cell Lamp 32W Fluorescent Circular

26

Emergency

410 x 105

Hades I - LED Emergency


Versatile emergency luminaire designed for a diverse range of installations requiring low maintenance and energy efficient LED technology.

Features
Lamp high output 3W LED High performance lens system Non-maintained operation and maintained Low power consumption and maintenance Integral gear and battery Vandal/tamper proof Switch mode power supply - reduced power consumption Energy efficient lamp source Alloy housing and bracket Aluminium face trim Durable powder coat paint finish

Applications
Ideal for feature emergency lighting applications or general emergency lighting around building exteriors and entry statements. Other applications include wall, column or post mounted in exposed positions or used under awnings and space frame structures.

Technical
Product Code
FFRLED FFRLEM C0 C90 C0 C90

Classification
D25 D25 D20 D20

2.1 14.2 14.2 13.1 13.1

2.4 14.7 14.7 13.6 13.6

2.7 15.3 15.3 14.1 14.1

3 15.7 15.7 14.5 14.5

Mounting Height in Metres


3.6 16.5 16.5 15.1 15.1 4 16.9 16.9 15.5 15.5 4.5 17.3 17.3 15.8 15.8

5 17.7 17.7 16.1 16.1

6 18.1 18.1 16.4 16.4

8 18.2 18.2 16 16

10 17.3 17.3 14.5 14.5

HID version shown

FFRLED

C0/C90 D25

Product Codes Code


HADONELEDM

Power Specifications
Input voltage and tolerance 230V AC +/- 10 Nominal frequency Nominal power Consumption VA Battery Battery operating temp Battery Voltage Battery A/hr rating Battery Charging 50/60Hz 8.3 (16hr) 2.9 NiMH 1700mAh -20C to +70C 4.8V 1700mAhr (run time 2.5hr) Dual rate ~170mA then pulse 1min/30min

Version
3W Maintained LED Emergency

HADONELEDNM 3W Non Maintained LED Emergency

Accessories
FFRLED
FFRLED / optical system

Replacement Non-Maintained emergency light

FFRLEDM Replacement Maintained emergency light

IP65
6.0kg

Max Dim(mm) 288 x 198 x 99

Emergency

27

Guardian GR99
Flood light emergency luminaire with adjustable beam for commercial applications, requiring aesthetic appeal.

Features
Lamp 2 x 9W tungsten halogen Twin adjustable beam lamps Polycarbonate body Non-maintained operation Complete with flex and plug Compliant with AS/NZS2293 Integral gear

Applications
Interior commercial and industrial. Retail stores, public auditoriums, warehouse facilities, factories, airports, and school halls.

Technical

Product Codes Code


Test button

Version
2X9W EM FLOOD Non-Maintained

adjustable beam lamps

GR99

Accessories
Battery 99019703 6V Sealed Lead Acid Note: Test report LL11247 for spacing distance available.

28

IP20

Emergency

max dim(mm)
6.5kg

335 x 365 x 130

Guardian GR21
Flood light emergency luminaire with adjustable beam for commercial applications.

Features
Lamp 2 x 21W tungsten halogen Twin adjustable beam lamps Formed steel housing Non-maintained operation Complete with flex and plug Filament failure indication Compliant with AS/NZS2293 Individual test buttons Integral gear

Applications
Interior commercial and industrial. Retail stores, public auditoriums, warehouse facilities, factories, airports, and school halls.

Technical

Product Codes Code


GR21
Filament failure indication Twin swivel heads

Version
2X21W Non-Maint EmergFlood.

Accessories
Battery Options 2 x 99019704 12V Sealed Lead Acid Heads can be remote mounted.

Note: Test report LL11247 for spacing distance available.


IP20
6.5kg

Max Dim(mm) 335 x 365 x 130

Emergency

29

Weatherlux
A versatile IP65 fluorescent exit luminaire, designed for 16m viewing distance, in compliance with AS/NZS2293.

Features
Energy efficient lamp 8W fluorescent Durable white polycarbonate body with quick connect removable gear tray Surface wall or ceiling mount Pictogram 16m viewing distance complete polycarbonate diffuser IP65 weatherproof construction Removable gear tray Tamper proof screws available as an option Maintained, non-maintained and sustained circuits available Choice of picto decals available

Applications
Damp environments, warehouses, production facilities, car parks, schools and coastal areas.

Product Codes Code


WL8NM

Version
1 x 8W Non-Maintained (body only) 1 x 8W Maintained (body only) 2 x 8W Sustained (body only)

Technical
Product Code
WL8M + WL01P WL8S + WL01P WL8M + WLO C0 C90 C0 C90 C180 C0 C90

WL8M WL8S
Classification
D8 E5 D10 C10 E3.2 D12.5 E12.5 2.1 9.4 6.6 10.2 7.3 6 11.1 8 2.4 9.7 7.2 10.6 7.7 6.2 11.5 8.8 2.7 9.9 7.4 10.9 8 6.4 11.8 9.4 3 10.1 7.8 11.1 8.3 6.6 12.1 10

Mounting Height in Metres


3.6 10.3 8.2 11.4 8.8 6.6 12.5 11 4 10.4 8.4 11.5 9 6.6 12.7 11.4 4.5 10.3 8.4 11.6 9.1 5.8 12.9 12

5 10.2 8.2 11.6 9.2 5.8 13 12.4

6 9.5 7 11.2 9.1 12.8 13

8 8.3 6.8 10.3 7.5 11.3 12.8

10 6.1 8.9 7.6 11.6

Accessories
Pictogram Diffusers WL01P WL02P WL03P WL04P WL08DPR WL06PR WL07DP WL05PL Spare parts: BP2S 2.4V NiCad, 2 cell Straight from here Left from here Right from here Ceiling Picto single sided Ceiling Picto double sided Right Ceiling Picto single sided Right Ceiling Picto double sided Ceiling Picto single sided Left

Note: Must specify diffuser required.

30

IP65

Emergency

max dim(mm)
3.0kg

368 x 102 x 150

Warden LED
Weatherproof IP65 exit luminaire designed with energy efficient LED technology housed in a rugged vandal resistant casing.

Features
High output strip LED Ceiling or wall mount Robust steel fabrication with UV resistant powder coating Low power consumption and maintenance Integral gear and battery New slim, aesthetic and practical design One box solution, complete with all Picto inserts Special design applications available Tough LEXAN diffuser Vandal/Tamper proof fixing available Theatre version available

Applications
Commercial, external and industrial applications, railway tunnels and platforms, carparks, prisons, courts and mining.

Robust steel fabricated body

Technical
Product Codes Code
Power Specications
Input voltage and tolerance Nominal frequency Nominal power Consumption VA Battery Battery operating temp Battery Voltage Battery A/Hr rating Battery Charging Power Factor 230V AC +/- 10 50/60Hz 6.5W 11.1 NiMH 1800mAh -20C to +70C 4.8V 1800mAhr (run time 2.5hr) Dual rate ~170mA then pulse 0.592 LPF
229mm 286mm 441mm 33mm

Version

WELED2VM24 weatherproof LED exit, vandal resistant, pictogram - 24m viewing distance WELED2VM24B weatherproof LED exit, theatre, vandal resistant, pictogram WELED2VM24R weatherproof LED exit, remote gear, vandal resistant, pictogram WELED2VM40 weatherproof LED exit, vandal resistant, pictogram - 40m viewing distance Black theatre WELED2VM24X1 Remote WELED2VM24X2

IP65
3.0kg

Max Dim(mm) 441 x 299 x 33

WP LED Exit

391

Emergency

31

Vandal X IP65
Vandal resistant emergency fluorescent exit luminaire designed for arduous environments in compliance with AS/NZS2293.

Features
Energy efficient lamp 10W fluorescent Strong die-cast aluminium housing coated in polyester white powder coat 6mm polycarbonate pictogram diffuser with 24M viewing distance Tamper proof security screws Fully approved to AS2293 thermal & illuminance requirements Impact tested and approved

Applications
High risk, arduous environments, prisons, detention centres, public access areas, railway stations and heavy industrial areas.

Strong die-cast aluminium housing

Technical
Product Codes Code
EVC210S 180mm

Version
2x10W sustained

Accessories
Pictogram Diffusers EVC01P 360mm EVC01PL EVC01PR Spare Parts BP2S Battery 2.4V Nicad, 2 cell Straight on from here Left from here Right from here

Note: Must specify diffuser required. Choice of picto decals available


IP65

Tamper proof tri-lobal screw

32

Emergency

max dim(mm)
3.0kg

360 x 180 x 170

Extreme
Oversize jumbo exit luminaire designed for 32m viewing distances compliant to AS/NZS2293.

Features
Energy efficient lamp 18W fluorescent Steel - white polyester powder coated housing with removable gear tray Polycarbonate pictogram diffuser with 32m viewing distance Wall or ceiling mount options Maintained, non-maintained and sustained available Single or double sided viewing options Compliant to AS/NZS2293

Applications
Large scale commercial environments, public areas, supermarket, department stores, convention, exhibition and entertainment centres, factories, warehouses and industrial sites.

Convenient test buttons

Product Codes

Technical
Product Code
EX18M + EX01 EX18M + 2xEX01 EX18M + EX01P EX18M + 2xEX01P C0 C90 C0 C90 C0 C90 C0 C90

Code
EX18M
Classification
D6.3 E3.2 D5 B6.3 D8 E4 D6.3 E3.2 2.1 8.6 6 7.8 5 9.4 6.2 8.6 6 2.4 8.8 6.2 8 5.3 9.7 6.6 8.8 6.2 2.7 9 6.4 8.1 5.5 9.9 7 9 6.4 3 9.1 6.6 8.2 5.7 10.1 7.2 9.1 6.6

Version
1x18W Maintained 1x18W Non-Maintained 2x18W Sustained

Mounting Height in Metres


3.6 9.2 6.6 8.2 6 10.3 7.4 9.2 6.6 4 9.2 6.6 8 6.1 10.4 7.4 9.2 6.6 4.5 9 5.8 7.7 6.1 10.3 7.2 9 5.8

5 8.7 5.8 7.3 6 10.2 6.6 8.7 5.8

6 7.7 5.7 5.4 9.5 7 7.7

8 5.7 1.6 4.1 8.3 5.7

10

EX18NM EX18S

Accessories
6.1

Pictogram Diffusers EX01P EX02P EX03P WGWE18 Straight on from here Left from here Right from here Wall Exit wire guard

Note: For wall/ceiling mount, single sided - select and specify one diffuser panel For ceiling mount double sided, select and specify two diffuser panels.

Battery BP4S2
IP20
3.0kg

4.8V NiCad, 4CELL

Max Dim(mm) 640 x 290 x 83

Emergency

33

EXDN IP66
Class 1 Zone 2 emergency exit luminaire designed for use in IIC gas, dust and ignition proof applications.

Features
Energy efficient lamp 10W fluorescent Durable grey polycarbonate housing with polycarbonate picto diffuser Class1 Zone 2, Ex n llC, DIP , Zone 21 & 22 Maintained or Sustained circuits available Viewing distance 24M Surface wall mount only Complies to AS/NZS2293 Convenient removable gear tray Large, quick release diffuser screws End to end conduit access

Applications
Designed for class1, zone 2 applications.

Technical
390

190 190mm

Product Codes Code Version


1x10W Maintained c/w 2x10W Sustained c/w

390mm
130

EXDN110- EXDN210-

130mm

Accessories
Spare Parts: BP2S Battery 2.4V NiCad, 2 Cell Diffusers available upon request

Choice of picto decals available


IP66 max dim(mm)
5.0kg

34

Emergency

390 x 130 x 190

Condo Weatherproof
An IP65 bulkhead suitable for interior or exterior use, providing resistance to moisture, impact, corrosive dust environments.

Features
Energy efficient lamp 28W2D fluorescent Surface mount Body cast aluminium - available in white or black UV stabilised, high-impact resistant, opal polycarbonate diffuser Silicon gasket for sealing integrity Stainless steel, allen-head screws Maintained and Non-Maintained operation Integral gear and battery compartment Compliant to AS/NZS2293

Applications
Weatherproof applications, commercial exterior, hospitals and large strata residential.

Technical
Product Code
CD28M C0 C90

Classification
D8 D8

2.1 9.4 9.4

2.4 9.7 9.7

2.7 9.9 9.9

3 10.1 10.1

Mounting Height in Metres


3.6 10.3 10.3 4 10.4 10.4 4.5 10.3 10.3

5 10.2 10.2

6 9.5 9.5

8 8.3 8.3

10 6.1 6.1

Product Codes Code


CD28MWT CD28MBK CD28NMWT CD28NMBK
360mm 175mm

Version
1 x 28W 2D Maintained White 1 x 28W 2D Maintained Black 1 x 28W 2D Non-Maintained White 1 x 28W 2D Non-Maintained Black

Polycarbonate diffuser

Silicon gasket

Accessories
Spare Parts: BP4S Battery 4.8V NiCad 4cell

IP65
2.0kg

Max Dim(mm) 395 x 225 x 81

Emergency

35

PWP & PWA


Corrosion resistant GRP weatherproof fluorescent luminaire designed with high performance T5 and T8 optics.

Features
Lamp 18W T8, 36W T8,14W T5, 28W T5, 35W T5 Tough corrosion resistant glass-fibre reinforced polyester body UV stabilised high impact polycarbonate lens (optional acrylic) Removable steel gear tray/reflector Polyurethane machine poured foam gasket Tamper resistant stainless steel (PWP) or polycarbonate (PWA) diffuser retaining clips Internal ribbed lens prism Optional IR and motion sensor capabilities Optional DALI Compliant to AS/NZS2293 20mm grommet cable entry at one end Maintained, non-maintained, combined maintained and combined maintained available

Applications
General weatherproof conditions, wet rooms, food processing areas, industrial plants, car parks.

Product Codes Code


PWP218M PWP218S PWP136M PWP136NM PWP236M

Version
2 x 18W Combined Maintained 2 x 18W Sustained 1 x 36W Maintained 1 x 36W Non-Maintained 2 x 36W Combined Maintained 1 x 14W T5 Maintained - wide body 2 x 14W T5 Combined Maintained 1 x 28W T5 Maintained - wide body 2 x 28W T5 Combined Maintained 2 x 35W T5 Maintained

Technical
Product Code
PWP218M PWP136NM PWP136M PWP236M C0 C90 C0 C90 C0 C90 C0 C90 C180

Classification
D40 C40 D50 C40 D50 C40 D50 C32 D20

2.1 16.7 10.6 18 10.6 18 10.6 18 10 13.1

2.4 17.4 11.3 18.7 11.3 18.7 11.3 18.7 10.7 13.6

2.7 18 11 19.4 11 19.4 11 19.4 11.3 14.1

3 18.6 12.6 20.1 12.6 20.1 12.6 20.1 11.8 14.5

Mounting Height in Metres


3.6 19.6 13.6 21.2 13.6 21.2 13.6 21.2 12.8 15.1 4 20.1 14.3 21.8 14.3 21.8 14.3 21.8 13.4 15.5 4.5 20.8 15 22.5 15 22.5 15 22.5 14 15.8

PWP114M
5 21.3 15.6 23.2 15.6 23.2 15.6 23.2 14.5 16.1 6 22.1 16.6 24.2 16.6 24.2 16.6 24.2 15.4 16.4 8 23 17.9 25.4 17.9 25.4 17.9 25.4 16.4 16 10 23.1 18.5 25.9 18.5 25.9 18.5 25.9 16.5 14.5

PWP214M PWP128M PWP228M PWP235M

Accessories
Spare Parts: BP4S Battery BP6S2 Battery BP8S2 Battery 4.8V NiCad, 4cell suits 18W/36W T8 7 .2V NiCad, 6cell suits 14W T5 9.6V NiCad 8cell, suits 28W & 35W T5

Dim (mm) 1 x 18W T8 2 x 18W T8 1 x 36W T8 2 x 36W T8 2 x 35W T5 697 x 102 x 108 697 x 172 x 108 1307 x 102 x 108 1307 x 172 x 108 1500 x 172 x 108
IP65 max dim(mm)
5.4kg

For acrylic models replace P in the catalogue with A i.e PWP114M becomes PWA114M

36

Emergency

1500 x 172 x 108

SDW / SDWA
Corrosion resistant GRP weatherproof fluorescent luminaire designed with high performance T8 Optics.

Features
Energy efficient lamp 18W, 26W, 36W fluorescent Tough corrosion resistant glass-fibre reinforced polyester body UV stabilised high Impact polycarbonate lens (optional acrylic) Polyurethane machine poured foam gasket Stainless steel diffuser clips, screw lockable Internal ribbed prism lens 20mm grommet cable entry at one end IP65 Optional DALI maintained Maintained, combined maintained, sustained and non-maintained Food industries - watershed bracket available Compliant to AS/NZS2293 Tough corrosion resistant glass-fibre reinforced polyester body

Stainless steel clips

Applications
General weatherproof conditions, wet rooms, food processing areas, dairies, industrial plants, car parks and wharves.

Product Codes Code Version

SDW218M 2 x 18W Combined Maintained SDW218S 2 x 18W Sustained SDW136M 1 x 36W Maintained SDW136NM 1 x 36W Non-Maintained
5 23.2 15.6 17.7 23.2 15.6 17.7 21.3 15.6 21.3 15.6 23.2 15.6 19.5 23.2 15.6 19.5 6 24.2 16.6 18.1 24.2 16.6 18.1 22.1 16.6 22.1 16.6 24.2 16.6 20.2 24.2 16.6 20.2 8 25.4 17.9 18.2 25.4 17.9 18.2 23 17.9 23 17.9 25.4 17.9 20.7 25.4 17.9 20.7 10 25.9 18.5 17.3 25.9 18.5 17.3 23.1 18.5 23.1 18.5 25.9 18.5 20.3 25.9 18.5 20.3

Technical
Product Code
SDW218M SDW218S SDW136M SDW136NM SDW236M SDW236S C0 C90 C180 C0 C90 C180 C0 C90 C0 C90 C0 C90 C180 C0 C90 C180

Classification
D50 C40 D25 D50 C40 D25 D40 C40 D40 C40 D50 C40 D32 D50 C40 D32

2.1 18 10.6 14.2 18 10.6 14.2 16.7 10.6 16.7 10.6 18 10.6 15.4 18 10.6 15.4

2.4 18.7 11.3 14.7 18.7 11.3 14.7 17.4 11.3 17.4 11.3 18.7 11.3 16.1 18.7 11.3 16.1

2.7 19.4 11 15.3 19.4 11 15.3 18 11 18 11 19.4 11 16.7 19.4 11 16.7

3 20.1 12.6 15.7 20.1 12.6 15.7 18.6 12.6 18.6 12.6 20.1 12.6 17.2 20.1 12.6 17.2

Mounting Height in Metres


3.6 21.2 13.6 16.5 21.2 13.6 16.5 19.6 13.6 19.6 13.6 21.2 13.6 18 21.2 13.6 18 4 21.8 14.3 16.9 21.8 14.3 16.9 20.1 14.3 20.1 14.3 21.8 14.3 18.5 21.8 14.3 18.5 4.5 22.5 15 17.3 22.5 15 17.3 20.8 15 20.8 15 22.5 15 19.1 22.5 15 19.1

SDW236M 2 x 36W Combined Maintained SDW236S 2 x 36W Sustained SDW128M SDW228M 1 x 28W Maintained 2 x 28W Combined Maintained

Accessories
Replacement Batteries BP4S BP4S2 4.8V Nicad, 4 cell to suit 136NM/M and 236M/S 4.8V Nicad, 4 cell to suit 218M/S

For 45 watershed factory fitted to 36W and 58W acrylic models suffix WS, ie. SDW236MWS For Acrylic diffuser models suffix A in catalogue number afterSDW136M ie. becomes SDWA136M

Dim (mm) 2 x 18W 2 x 36W 657 x 198 x 125 1267 x 198 x 125
IP65
6.5kg

Max Dim(mm) 1270 x 177 x 115

Emergency

37

SDIP
IP66 emergency fluorescent luminaire designed for hazardous, and chemical environments.

Features
Energy efficient lamp 18W and 36W fluorescent Class 1 Zone 2, Ex n IIC Zone 21 & 22 Glass-fibre reinforced body High impact polycarbonate diffuser with stainless steel diffuser clips, screw lockable IP66 Complies to AS/NZS2293 Supplied with mount brackets Dual conduit access facilities Combined-maintained operation

Applications
Grain processing and handling areas, wineries, coal storage and handling sites, wharves and arduous environments.

Technical

Product Code
SDIP218M-DIP SDIP218M-EXN SDIP236M-DIP SDIP236M-EXN C0 C90 C180 C0 C90 C180 C0 C90 C180 C0 C90 C180

Classification
D50 C40 D25 D50 C40 D25 D63 C50 D40 D63 C50 D40

2.1 18 10.6 14.2 18 10.6 14.2 19.4 11.3 16.7 19.4 11.3 16.7

2.4 18.7 11.3 14.7 18.7 11.3 14.7 20.3 12 17.4 20.3 12 17.4

2.7 19.4 11 15.3 19.4 11 15.3 21.2 11.8 18 21.2 11.8 18

3 20.1 12.6 15.7 20.1 12.6 15.7 21.8 13.4 18.6 21.8 13.4 18.6

Mounting Height in Metres


3.6 21.2 13.6 16.5 21.2 13.6 16.5 23 14.5 19.6 23 14.5 19.6 4 21.8 14.3 16.9 21.8 14.3 16.9 23.7 15.2 20.1 23.7 15.2 20.1 4.5 22.5 15 17.3 22.5 15 17.3 24.5 16 20.8 24.5 16 20.8

5 23.2 15.6 17.7 23.2 15.6 17.7 25.2 16.7 21.3 25.2 16.7 21.3

6 24.2 16.6 18.1 24.2 16.6 18.1 26.4 17.9 22.1 26.4 17.9 22.1

8 25.4 17.9 18.2 25.4 17.9 18.2 28.1 17.9 23 28.1 17.9 23

10 25.9 18.5 17.3 25.9 18.5 17.3 28.9 18.5 23.1 28.9 18.5 23.1

Product Codes Code


SDIP218M-DIP SDIP236M-DIP

Version
2 x 18W Combined Maintained 2 x 36W Combined Maintained

Accessories
Replacement Batteries BP4S 4.8V Nicad, 4 cell to suit 136NM/M and 236M/S BP4S2 4.8V Nicad, 4 cell to suit 218M/S

38

IP66

Emergency

max dim(mm)
5.4kg

1270 x 177 x 115

Vandaguard
Low profile IP66 fluorescent weatherproof luminaire designed for hostile and vandal prone environments.

Features
Energy efficient lamp 18W, 36W fluorescent Pressure die-cast marine grade LM20 aluminium body with separate battery compartment Robust reeded or clear prismatic polycarbonate diffuser Complete with security screws, removable gear tray and single one piece gasket Low profile IP66 protection Maintained, combined-maintained, combined nonmaintained or non-maintained Complies to AS/NZS2293 Dual conduit access Optional DALI maintained Optional motion and IR sensor capabilities

Secure access screws

Applications
Prisons, subways, railway stations and underground carparks.

Tough polycarbonate lens

Technical
Product Code
VPF118M VPF218M VPF136M VPF136NM VPF236M C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180

Product Codes Code


Classification
D16 C16 D20 C16 D20 D25 C20 D25 C20 D32 C25 D32 2.1 12.1 8.3 13.1 8.3 13.1 14.2 13.1 14.2 8.9 15.4 9.4 15.4 2.4 12.6 8.8 13.6 8.8 13.6 14.7 13.6 14.7 9.4 16.1 10 16.1 2.7 13.4 9.3 14.1 9.3 14.1 15.3 14.1 15.3 9.9 16.7 10.5 16.7 3 13.1 9.7 14.5 9.7 14.5 15.7 14.5 15.7 10.3 17.2 11 17.2

Version
1 x 18W Maintained 1 x 18W Non-Maintained 2 x 18W Combined Maintained 2 x 18W Sustained 1 x 36W Maintained 1 x 36W Non-Maintained 2 x 36W Combined Maintained 2 x 36W Sustained

Mounting Height in Metres


3.6 13.9 10.3 15.1 10.3 15.1 16.5 15.1 16.5 11.1 18 11.9 18 4 14.1 10.7 15.5 10.7 15.5 16.9 15.5 16.9 11.5 18.5 12.4 18.5 4.5 14.6 11 15.8 11 15.8 17.3 15.8 17.3 12 19.1 12.9 19.1

5 14.6 11.3 16.1 11.3 16.1 17.7 16.1 17.7 12.3 19.5 13.4 19.5

6 14.6 11.6 16.4 11.6 16.4 18.1 16.4 18.1 12.8 20.2 14 20.2

8 13.8 11.3 16 11.3 16 18.2 16 18.2 13 20.7 14.6 20.7

10 11.5 9.6 14.5 9.6 14.5 17.3 14.5 17.3 12 20.3 14.2 20.3

VPF118M VPF118NM VPF218M VPF218S VPF136M VPF136NM VPF236M VPF236S

Dim (mm) 1 x 18W T8 2 x 18W T8 1 x 36W T8 2 x 36W T8 670 x 140 x 80 670 x 140 x 80 1310 x 140 x 80 1310 x 140 x 80
IP66
8.5kg

Accessories
Spare Parts: 99010318 Battery 9.8V NiCad, 4 cell BP4S Battery
Max Dim(mm) 1310 x 140 x 80

4.8V NiCad, 4 cell stick

Emergency

39

NEW IM
Technical

40

Emergency

max dim(mm)

MAGE
Technical

Max Dim(mm)

Emergency

41

Vandalux
Adverse and weatherproof IP66 fluorescent luminaire designed for hostile, industrial and vandal prone environments.

Features
Energy efficient lamp 18W, 36W fluorescent Pressure die-cast marine grade LM20 aluminium body with (separate battery compartment, 18W only) Heavy-duty reeded or clear prismatic polycarbonate diffuser Removable gear tray Maintained, combined-maintained, combined nonmaintained or non-maintained Complete with security screws and single piece gasket IP66 protection Standard finished chromate treated APO grey epoxy powder coat Option safety orange body finish available Complies to AS/NZS2293 Dual conduit access Optional DALI Optional motion and IR sensor capabilities

Applications
Weatherproof for hostile, industrial and vandal prone environments, railway stations, subways and car parks.

Technical
Product Code
VP118M VP218M VP136M VP136NM VP236M C0 C90 C0 C90 180 C0 C90 C0 C90 C0 C90 180

Product Codes Code


Classification
D16 C16 D20 C16 D20 D25 C20 D25 C20 D32 C25 D32 2.4 12.6 8.8 13.6 8.8 12.6 14.7 9.4 14.7 9.4 14.7 9.4 14.7 2.7 13.4 9.3 14.1 9.3 13.4 15.3 9.9 15.3 9.9 15.3 9.9 15.3 3 13.1 9.7 14.5 9.7 13.1 15.7 10.3 15.7 10.3 15.7 10.3 15.7

Version
1 x 18W Maintained 1 x 18W Non-Maintained 2 x 18W Combined Maintained 2 x 18W Sustained 1 x 36W Maintained 1 x 36W Non-Maintained 2 x 36W Combined - Maintained 2 x 36W Sustained

Mounting Height in Metres


3.6 13.9 10.3 15.1 10.3 13.9 16.5 11.1 16.5 11.1 16.5 11.1 16.5 4 14.1 10.7 15.5 10.7 14.1 16.9 11.5 16.9 11.5 16.9 11.5 16.9 4.5 14.6 11 15.8 11 14.6 17.3 12 17.3 12 17.3 12 17.3

5 14.6 11.3 16.1 11.3 14.6 17.7 12.3 17.7 12.3 17.7 12.3 17.7

6 14.6 11.6 16.4 11.6 14.6 18.1 12.8 18.1 12.8 18.1 12.8 18.1

8 13.8 11.3 16 11.3 13.8 18.2 13 18.2 13 18.2 13 18.2

10 11.5 9.6 14.5 9.6 11.5 17.3 12 17.3 12 17.3 12 17.3

VP118M VP118NM VP218M VP218S VP136M VP136NM VP236M VP236S

Dim (mm) 1x18W T8 2x18W T8 1x36W T8 2x36W T8 670 x 140 x 120 670 x 140 x 120 1310 x 140 x 120 1310 x 140 x 120
IP66 max dim(mm)
6.3kg

Accessories - see Vandalux adverse section


Spare Parts: 99010318 BP4S Battery 4.8V NiCad 4 cell Battery 4.8V NiCad 4 cell stick

42

Emergency

1310 x 140 x 120

Emergency

43

NXS
Heavy duty IP65/67 bulkhead for adverse applications.

Features
Energy efficient lamp 18W compact fluorescent Robust die cast aluminium body Borosilicate glass diffuser Non-Maintained operation Ceiling or wall mount design Complies to AS/NZS2293 Integral control equipment 4 x M20 conduit access (industrial) 4 x M25 conduit access (mining) Industrial version IP65 Mining version IP67

4 x M20 conduit access (industrial) 4 x M25 conduit access (mining)

Applications
Industrial sites, mine sites and adverse conditions.

Technical
Product Code
NEX118NM C0 C90

Classification
D20 D12.5

2.1 13.1 11.1

2.4 13.6 11.5

2.7 14.1 11.8

3 14.5 12.1

Mounting Height in Metres


3.6 15.1 12.5 4 15.5 12.7 4.5 15.8 12.9

5 16.1 13

6 16.4 12.8

8 16 12.3

10 14.5 11.3

Borosilicate glass diffuser

Product Codes Code


184

Version
1 x 18W Non-Maintained

NEX118NM

Accessories
Spare Parts: BP4S Battery NSXWG 4.8V NiCad 4cell Wire guard

29

19

NSXV Visor

44

IP65/67

Emergency

max dim(mm)
5.9kg

298 x 193 x 184

Emergency

45

Maxi Pac IP65


Robust IP65 fluorescent bulkhead designed for weatherproof and adverse applications.

Features
Energy efficient lamp 18 watt compact fluorescent Removable gear tray Non-maintained operation or maintained 20mm cable entry knockouts at both ends Robust cast aluminium body Reeded polycarbonate diffuser Strong versatile bulkhead Circular compression gasket Complies to AS/NZS2293 Integral control equipment Ceiling or wall mount Colour white

Robust cast aluminium body

Applications
Weatherproof environments, factories, walkways, car parks, and industrial zones.

Technical
Reeded polycarbonate diffuser
Product Code
LPC118M C0 C90

Classification
D16 D8

2.1 12.1 9.4

2.4 12.6 9.7

2.7 13.4 9.9

3 13.1 10.1

Mounting Height in Metres


3.6 13.9 10.3 4 14.1 10.4 4.5 14.6 10.3

5 14.6 10.2

6 14.6 9.5

8 13.8 8.3

10 11.5 6.1

Product Codes Code


161
LPC118M LPC118NM

Version
1 x 18W Non-Maintained 1 x 18W Maintained

220

31

Accessories
Spare Parts: BP4S Battery 4.8V NiCad 4cell

46

IP65

Emergency

max dim(mm)
3.7kg

315 x 220 x 161

Metro Emergency
A versatile luminaire using an energy saving compact fluorescent lamp with self-contained emergency circuit.

Features
Glass filled Nylon moulded body for strength Polycarbonate prismatic diffuser with reflector Silicon gasket provides weather ingress protection Modular heavy duty gear tray Twist-off diffuser for easy lamp replacement Fits Std diameter 34mm pipe spigot Uses energy saving compact fluorescent lamp Maintained unit with electronic module Non maintained or Maintained with integral inverter Universal bracket supplied with fitting

Applications
For general security lighting around industrial areas, public amenities and high density housing projects. Also suitable for general lighting around mining infrastructure such as conveyors, loaders and gantries.

Technical

164mm

100mm

Product Codes Code Version

Dim (mm)

Mass (kg)

105mm

285mm

150mm

NON MAINTAINED METROPLC18NM 18W PLC METROPLC32NM 32W PLC MAINTAINED METROPLC18MEL 18W PLC 490 x 170 x 180 3.0 490 x 170 x 180 490 x 170 x 180 3.0 3.0

Wall

Corner

Pole

Accessories
All mounting brackets included. BP4S2 97002252
IP65
3.0kg

18W / 32W Non-Maintained battery NiCad 18W Maintained battery NiCad

Max Dim(mm) 490 x 170 x 180

Emergency

47

FOOLPROOF INSTALLATION The DIGINET System is as simple to install as a non-monitored single point system, just install the emergency lights as per plans and by using a CMS type cabling connection method, the system should not be compromised by poor cable connection. The plug & play type cabling will connect to a small wall mounted LCD display computer, then by simply commissioning each product into the computer the system is ready to go. DIGINET is a simple, intelligent emergency lighting management system designed by industry experts to effectively manage and monitor the status of emergency lighting within a network. DIGINET utilises a DALI international open protocol to communicate between luminaires and the computer software. Types of applications for a DIGINET system Commercial & industrial installations Low rise office or apartment buildings Multiple building campuses Hospitals Correctional facilities Educational facilities Health centres and aged care facilities Centralised emergency light management SELF MONITORING DIGINET is self monitoring, it can diagnose system and product faults in readiness for maintenance access at either the 6 monthly test or anytime in between. INDEPENDENT OR COMPLETE-YOUR CHOICE You can choose whether to cable for an independent DIGINET Emergency Lighting Management system or a Complete DALI Lighting Management system, the cabling and connection remains the same simple method for both systems therefore both systems can connect to the same wiring loop. This will reduce Labor, Cost and confusion. EASY SYSTEM CONTROLS The DIGINET system features a unique LCD graphical user interface type computer to control and monitor. This is accessible via ethernet, LAN, WAN etc. The LCD control panel can be located in an electrical/data riser, front desk etc. and accessed on any PC via an allocated IP address over the internet. SIMPLE AUSTRALIAN STANDARDS COMPLIANCE The DIGINET emergency lighting management system makes compliance with AS2293.2 and various State and Local regulations very easy. The system is designed to run the required 6 monthly discharge tests, create maintenance logs and run compliance reports to assist in making sure that a crucial building safety system stays operational. The system provides reliable data that is not compromised by human error and makes it quick and easy to access.

3 x typical system styles

Small projects <60 points

Medium projects up to 120 points

Large projects up to 600 points

NB: For projects +600 units refer Pierlite Australia

Emergency

48

DIGINET DALI Emergency Control Panel


DIGINET DALI Touch Screen Control Panel

Features
Simple one touch control system Automatic initiation and logging of tests User friendly colour interface On screen luminaires health status Up to 120 emergency lighting points per panel Interconnect up to 10 Panels using Ethernet backbone The DIGINET product has been designed in accordance with International DALI standard IEC 62386.

Applications
Small to medium commercial & industrial installations, low rise office or apartment buildings, multiple building campuses, small to medium public buildings, health centres and aged care facilities.

Technical

L N

EXIT SIGN

EMERGENCY LIGHT

DALI PSU

DALI PSU

EXIT SIGN

EMERGENCY LIGHT

Product Codes
DA DA

DA DA DIGINET TOUCH SCREEN CONTROLLER

Code
99005257

Version
DIGINET DALI Touch Screen Control Panel

24-48V DC 10VA

Accessories
Power Supply 99005256 99005255 DALI PS1 Surf Remote (200MA) PS DALI DIN Rail

IP20
0.92kg

Max Dim(mm) 200 x 150 x 20

Emergency

49

DIGINET Cable Management Options


Simplicity, flexibility and efficiency is the key to installation and interconnection of a DIGINET DALI management system.

Features
Simplifies the wiring and provides Plug & Play connectivity 5 way hard and soft wiring solutions available Reduce wastage in materials Luminaires and interconnecting cables can be installed at the same time Combined lighting, power, control and communication wiring eliminates the need for separate Data Cabling. Add Luminaires or Devices by simply plugging in. Reduce the quantity and variety of wiring required in an installation.

Applications
5 way soft and hard wiring connectivity solutions are available for commercial, residential, infrastructure or industrial lighting applications. It is highly recommended that in every installation, 5 core cabling such as 5 core round, 5 core flat or 5 core structured cabling solution is taken to each zone and then routed to each luminaire. This gives total flexibility and makes the project future proof.

Technical
QF1 QF2 A5T
Plugging multiple A5T reduces the No. of QF2 leads required.

QF3c Lead mates with Qf6 Plug in fitting. 2 5x1.0mmmaximum length 2.5 metres.

QF3 Lead hard wired 2 to fitting. 3x2.5mm 2 (A,N,E) & 2x1.5mm Dali.w

QF3a Lead hard wired 2 to fitting. 5x1.0mm , maximum 2.5metres.

QF3b Lead mates with QF6 Plug 2 in fitting. 3x2.5mm (A,N,E) & 2 2x1.5mm Dali. QF6

5 core flat
QF5 Interceptor allowing splitting of circuits/new power supply.

Light Fitting

Cable and Connector Technical specification: Mains 240VAC. 16A and 20A versions available 5 core wiring which typically consists of 3 x conductors for A, E, N and 2 x conductors for DALI (min 1.5mm2) allowing for up to 64 DALI Addresses over 300 metres. Contact your local Pierlite office for further details

B5.2 Connector - Field

B5T Fits directly into QF6

QF4 Hard wired to fitting.

QF3 & QFS3 hard wired to fitting.

QF1

New power supply

50

Emergency

EMERGENCY TECHNICAL

Technical Technical

51 51

Pierlite Emergency Lighting


Pierlite emergency luminaires have captured the essence of design presence and continuity, satisfying the designers needs and the installers installation criteria. Meeting with compliance to IEC60598-2-22 enables the design of emergency lighting units to be more flexible. EMC Electromagnetic Compatibility (EMC) under the opus of AS/NZS4051:1998 deals with devices such as lighting/emergency lighting products that may have the potential to cause interference to radio communication systems. This may be mains disturbance (noise down the line), radiation (giving out interfering frequencies from components) or deceptability (interference of frequency due to external noise). Under AS/NZS4051:1998 lighting/emergency lighting products must comply with disturbance levels between 9 KHz and 30 MHz. All Pierlite lighting/emergency lighting products comply with the above standard. EMERGENCY EVACUATION LIGHTING FOR BUILDINGS - AS/NZS2293.1 Spacing of emegency luminaires in Australia Spacing of emergency luminaires are based on illuminance calculations where the light reaches the floor directly from the emergency light source. Minimum illuminance level for emergency lighting is 0.2 lux. Please use classification tables provided with each product. ie: DB136M Emergency Classification C0 - D40 C90 - C40 C180 - n/a Emergency Classification C0 - D40 C90 - C40 C180 - n/a LC(NZ) - Classification of the above luminaire modified by the (UF) factor of the area to be illuminated. UF - Determines the proportion of light output from a lamp that falls on a particular area for emergency lighting.

Spacing of emegency luminaires in New Zealand Spacing of emergency luminaires is based on light that reaches the floor by reflection from the surfaces of the room, ie: ceiling and walls. Therefore you are required to obtain the utilisation factor of the required luminaire and then calculate the amount of emergency luminaires needed. Minimum illuminance level for emergency lighting is 1 lux. Formula for spacing of emergency luminaires in New Zealand is: LC(NZ) = LC(AUST) 6 - (6.6 x UF) LC(AUST) - Classification of emergency luminaire to Australian standard. ie: DB136M

Required Calculation
RI (Room Index) = Length x Width

Height (Length + Width) ie: RI (0.95) = 10 x 4 3 (10 + 4) From Room Index locate UF Factor from chosen fitting, ie. 0.42 LC(NZ) = D40 = D12.4 6 - (6.6 x 0.42) Move to the nearest higher classification which would be D12.5. Refer to Pages 422 and 425 of the Technical Section for luminaire spacing tables. Note: If the Utilisation Factor for the room is greater than 0.75, the New Zealand formula does not apply. Apply the Australian table classifications only. If the Utilisation Factor for the room is less than 0.15, the value of 0.15 shall apply and be used in the New Zealand formula.

52

Technical

New Standard Requirements


The Emergency Lighting Working Group, a working group of Lighting Council Australia, provides the following advice regarding changes to emergency lighting standards in Australia. The following new emergency lighting standards are now published: AS2293.1:2005 System design, installation and operation AS2293.3: 2005 Emergency escape luminaires and exit signs These standards replaced: AS/NZS2293.1:1998 and AS/NZS2293.3:1995 Significant changes from AS/NZS2293.1:1998 include: replacement of word exit with pictogram inclusion of detailed restrictions on use of arrows revision of maximum viewing distances for exit signs adoption of terminology from IEC60598.2.22 unlike the 1998 version, this standard is not a joint Australian/New Zealand document; there is no content specific to New Zealand The principal reason for the AS/ NZS2293.3:1995 edition of the standard is to specify requirements for exit signs employing internationally accepted pictograms, instead of the previously used word Exit. Terminology used to describe the subject matter has been modified in both standards to be compatible with that used in IEC60598.2.22 Luminaires Part 2.22 Particular requirements luminaires for emergency lighting. The new terminology recognises that the term emergency lighting includes four categories of lighting, each incorporating an alternative energy supply, as follows: emergency escape lighting illuminated emergency exit signs high risk task area lighting standby lighting However as reflected in the new series title, only two of these four categories are addressed in the AS2293 standards namely emergency escape lighting and illuminated emergency exit signs. Pictograms The new standards allow only the following pictograms from the international standard document ISO3864-1: Element Height (mm) Maximum Viewing Distance (m) 100 <150 16 150 <200 24 200 <250 32 250 -- 40 The maximum viewing distance must be marked on the face of each diffuser located on the background, either within one of the elements or on additional background. Australian Building Code Position The Australian Building Codes Board recognised the new emergency lighting standards as at 1st May 2006. The new standards may be utilised on a project by project basis, if approved for the project by the applicable local authority.

Modes of Operation
Terminology used to describe the Models) of operation has been modified to include luminaires with multiple emergency lamp configurations. Please refer to the table opposite.

Straight On From Here Left From Here Right From Here

Size Of Pictorial Elements Minimum pictorial element height for all illuminated exit signage is 100mm. There is no limit on the maximum pictorial element height. The four recommended pictorial element heights of 100, 150, 200 and 250mm correspond to maximum viewing distances as follows.

Technical

53

Recommended Locations
Exit Doors Locate emergency exit luminaire at each exit door. Exit signs shall be mounted at between 2m and 2.7m above floor level, or immediately above the door if higher than 2.7m Ensure the exit does not exceed maximum viewing distances recommended. Check emergency escape route is clear of obstacles and that the minimum illuminance level of 0.2 lux is achieved. Intersecting Corridors An emergency luminaire is to be installed within 2 meters of the intersecting corridors. Change in Direction An emergency luminaire is to be installed within 2 meters of an intersection at the change of direction except when the change of direction does not have interference of the wall of the corridor and that the C0/C90 spacing is not exceeded. Change in Floor Level An emergency luminaire is to be installed at each change of floor level, on the low side. Stairways Provide emergency luminaires to ensure that each flight of stairs including the intermediate landing receives direct light. A minimum of 1 lux is required. Note: If the intermediate landing in an enclosed stairwell is no longer than 2m in length that intermediate landing need not receive direct lighting. Escalators Emergency lighting is required for escalators to enable users to get off them safely. Toilets (Not referred to in standard but highly recommended) Toilets incorporating 2 or more cubicles or exceeding an area of 8m2 require emergency lighting. Emergency lighting is also to be incorporated into handicapped toilet facilities. Switch Rooms Place emergency lighting in control, plant or switch rooms that have the provision to provide normal and emergency lighting to the premises. Covered Car Parks Are treated as part of the normal emergency lighting design and full consideration of exit and emergency lighting is taken into account.

NOTE: This example emergency lighting layout has been created in the intended spirit of AS2293 and should be used as a guide only.

54

Technical

Powerpack Suitability & Performance Guide


Use Code to Choose Correct Power Pack for Emergency Tube/Lamp

2 Hour Duration
Unit

2 Hour Duration - T5 Use Code to Choose


Correct Power Pack for Emergency Tube/Lamp
Inverter 14W T5 Inverter 28W T5 Inverter 35W T5 Inverter 49W T5 Inverter 54W T5

BILW2/18/6E Inverter 18W 7 .2V C BILW2/36/6E Inverter 36W 7 .2V D BILW2/58/6E Inverter 58W 7 .2V E BILW2/36/8E Inverter 36W 9.6V F Note: E Signifies inverter operates on both standard & electronic ballasts

Description Code

Unit

BILWT5/2/14/6 BILWT5/2/28/8 BILWT5/2/35/8 BILWT5/2/49/8 BILWT5/2/54/8

Description Code
7 .2V 9.6V 9.6V 9.6V 9.6V G H I J K

T8 18W 19 47 32 T8 30W 12 20 T8 36W 12 25 50 T8 58W 8 17 2G11 PL18 13 47 22 2G11 PL24 18 30 2G11 PL36 16 27 G24Q PLC13 27 45 G24Q PLC18 30 50 G24Q PLC36 24 40 GR10Q 2D10W 27 45 GR10Q 2D21W 25 42 GR10Q 2D28W 19 32 2G10 DF18 14 23 2G10 DF24 14 23 2G0 DF36 16 7

% Ballast Lumen Factor Base Lamp A B C D E F

T5 14W 51 T5 28W 37 T5 35W 29 T5 49W 22 T5 54W 21

% Ballast Lumen Factor Base Lamp G H I J K

T5 Lamp Guide Lamp Type Watts Length Initial Lumens Rated Life
T5 14W 550 Linear 28W 1150 Fluorescent 35W 1450 49W 1450 54W 1150 1350 2900 3650 4300 5000 16000 16000 16000 16000 16000

Battery Pack to Suit Nickel Cadmium Fixing Centre Part Description Inverter Size Fixing
BP4S 4 cell pack 4.8V stick format 282x36 BILW/4ESeries 173x38x31 166 BP6S2 6 cell pack 7.2V 3+3 format 218x36x2 BILW/6ESeries 173x38x38 166 BP8S2 8 cell pack 9.6V 4+4 format 282x36x2 BILW/8ESeries 173x38x38 166

Battery Pack to Suit Nickel Cadmium Part Description Inverter Size Fixing Centre
BP6S2 6 cell pack 7.2V 3+3 format 218x36x2 BILT5 Series 173x38x38 166 BP8S2 8 cell pack 9.6V 4+4 format 282x36x2 BILT5 Series 173x38x38 166

Battery Pack to Suit Nickel Metal Hydride Part Description


P6S6 6 cell pack 7.2V block format 252x38x21 P8S6 8 cell pack 9.6V block format 320x38x21

Battery Pack to Suit Nickel Metal Hydride Part Description


P4S6 4 cell pack 4.8V block format 187x38x21 P6S6 6 cell pack 7.2V block format 252x38x21 P8S6 8 cell pack 9.6V block format 320x38x21

Technical

55

Information & Wiring Guidelines for Powerpacks & Inverters


Please read these instructions carefully before installing or maintaining this equipment. This data should be used as a guide only. Good electrical practices should be followed at all times. Recommended Installation /Maintenance Guidelines The installer is responsible for all relevant safety and building code standards. Do Not Megga After Installation It is recommended to disconnect live and neutral wires from the unit before an insulation resistance check. Converting An Existing Luminaire Installing a Power Pack will usually void the manufacturers warranty and EMC compliance. It is the installers responsibility to comply with relevant wiring, EMC and emergency lighting requirements in accordance with the relevant sections of AS2293 which may include the necessity to have the luminaire tested and certified both thermally and photometrically. Power Packs normally installed inside the luminaire may require the repositioning of components in the luminaire, ie. starter, ballast, capacitor. Any of the components being utilised that now show signs of end of life should be replaced at the time of converting the power pack. It is also advised that the internal wiring be replaced using the recommended high temperature cable (V90) minimum. Use Of Remote Enclosures Thermal conditions and/or lack of space in the luminaire may result in remote mounting of the power pack in an appropriate remote enclosure. Ensure the following is taken into account:Ensure test switch is accessible during re-lamping. It may be mounted within the luminaire or remote enclosure. LED is to be visible during normal operation irrespective of mounting within the luminaire or remote enclosure. Connecting cables to the enclosure are not to exceed 1 metre. Resistance of the battery wires are not to exceed 0.5ohms. Ensure battery leads are kept as short as possible. Testing The Conversion Of the Luminaire Confirm its electrical safety and its operation. Confirm the temperature of main components utilised in the luminaire comply with recommended requirements. The luminaire should be mounted as intended. The ambient temperature is to be as expected for the luminaires intended environment. Apply maximum voltage prescribed for a period of 24 hours, then switch off the luminaire and ensure that it provides appropriate emergency duration in accordance with relevant standards. Examine temperature of relevant components. If components comply with the prescribed temperature, then the balance of the luminaire may be converted the same way. Note BILW Power Packs incorporate a thermistor to protect componentry from overheating in excessive temperatures. Once tripped it may only be reset by switching off the mains. Once stable conditions are achieved, reconnect mains. Pierlite emergency luminaires have Ta Ratings from Ta30 to Ta40. When installing a BILW power pad feed the supply cable through the appropriate cable entry. Avoid obstruction to mounting holes, other lighting componentry and covers. It is recommended that a full duration test is carried out prior to commissioning. Upon appropriate connection, initially charge the luminaire for a minimum of 24 hours. Upon charging, the red LED will light indicating that mains is present and batteries are charging. After 24 hours disconnect the supply and check for the rated duration period. Pressing the test button carries out a quick confidence test. Routine tests should be carried out in accordance with the relevant Standards, with all results and status recorded in a log book. Batteries are to be replaced with the same Pierlite battery pack. The model number is stamped on the battery pack. When disposing of batteries do not pierce, incinerate or short circuit. Batteries should be disposed of in accordance with recognised disposal methods. Powerpacks and inverters are designed to operate on 230V AC 50/60Hz

56

Technical

Mains & Lamp Connection Diagrams


For the standard fluorescent Exit range.

Maintained and Non-Maintaned

Sustained

Technical

57

Wiring Diagrams for Standard - Electronic Ballasts


The wiring diagrams are given as a guide to installation with electronic ballasts. Due to the wide variety of electronic ballast units and connection styles available, it is advisable that the luminaire be fully tested to prove its correct functionality.

NOTE For Non-Maintained use 1 Delete ballasts & starter 2 Only connect Pin 1 & Pin 3 lamp 3 Connecting neutral to lamp will improve striking 4 For further technical data visit www.pierlite.com

NOTE 1 Do not flash test 2 All connections shall be made with at least V90 rated solid core 0.5mm wire

58

Technical

EMERGENCY FAULT FINDING FLOW CHART


EXIT
LED Check LED Inverter lamp is On
Check the power is on and connected to a non switched circuit. Then retest Check the power is on and connected to a non switched circuit. Then retest

EMERGENCY FAULT FINDING FLOW CHART


BATTEN
Check the power is on and connected to a non switched circuit. Then retest

10W

NO

NO

Check LED Inverter lamp is On

Check LED Inverter lamp is On

NO
Fail

Fail
Return with PFR to QA Co-ordinate resolution with QA

Pass

Pass

Fail
Return with PFR to QA Co-ordinate resolution with QA

Pass

Return with PFR to QA Co-ordinate resolution with QA

YES
LED lamps Off

YES YES
Check LED strip & batteries are pluged into PCA board

YES
Lamps Off

YES
Check lamp is functioning

Lamp Off

YES
Check both lamps are functioning Replace faulty lamp

NO
Fails
Check battery connected and/or Has battery been charged for 16hrs

Fails
Check battery connected and/or Has battery been charged for 16hrs

OK EXIT OK YES
Return inverter with PFR to QA Co-ordinate resolution with QA

OK

Replace faulty lamp

Put in Emergency Mode

Fails
Check battery connected and/or Has battery been charged for 16hrs

OK BATTEN OK YES
Return inverter with PFR to QA Co-ordinate resolution with QA

NO
Charge battery for 16hrs

YES
Return inverter with PFR to QA Co-ordinate resolution with QA Battery ok for 90min

NO
Charge battery for 16hrs

NO
TEST Fail 90min test Replace battery

TEST Fail 90min test Replace battery

Battery ok for 90min

Charge battery for 16hrs

TEST Fail 90min test Replace battery


BDM Emergency Lighting - David Virgona 0408 181 404 Version 1 : 30.03.09

Battery ok for 90min

BDM Emergency Lighting - David Virgona 0408 181 404

Version 1 : 30.03.09

Technical

59

GUIDE TO SAFE HANDLING OF LIGHTING PRODUCTS CONTAINING BATTERY SYSTEMS.


Introduction:
Battery systems are an essential component in a number of lighting products, especially emergency lighting systems, which require an alternative energy source when the traditional mains supply source fails. Handling and maintenance procedures for lighting battery circuits is no different to handling conventional battery components ie: scheduled maintenance is an essential process in maintaining the components service life and disposal of the components at the end of the service should be conducted in a safe and environmentally responsible manner. The following information serves as a guide to safe handling and maintenance of Pierlite Lighting products containing battery components. Battery performance should be checked on a regular schedule and components replaced when the performance falls below the manufacturers specification. Failed components should be disposed of in accordance with local waste management requirements. In the instance of a catastrophic failure resulting in a ruptured battery casing, the component should be handled with extreme care, avoiding contact with the installers skin, eye or inhalation. Suitable protective clothing is recommended for such maintenance procedures. The components and contaminated protective clothing should then be disposed of in accordance with your local waste management requirements. If skin or clothing comes in contact with fluid from a Nickel Cadmium (NiCad) or Nickel Metal (NiMH) battery, thoroughly wash the area immediately with clean water and seek medical care where needed.

60

Technical

The sun and the moon, two dominant sources of light control. The third is Pierlite.

Pierlite is a member of the Gerard Lighting Group.

Issue: October 2010 Product region: Australia Pierlite is a member of the Gerard Lighting Group. 2010 Pierlite Australia and acknowledgements where noted. www.pierlite.com