PHASE VOLTAGE BALANCE RELAY FOR THREE PHASE SYSTEM INCORPORATING PHASE SEQUENCE MONITORING

YWRUP.S for DIN rail mounting 11WRUP.S for 11 pin plug-in mounting

Overvoltage and undervoltage relay Minimum and maximum threshold adjustable separately up to 30% LED indicators for overvoltage, undervoltage and state of relay Output relay: SPCO 10 A 2% repeat accuracy
YWRUP.S 11WRUP.S

MODE OF OPERATION The output relay is energised when the phase sequence is correct and when all three phase voltage values are between the maximum and minimum thresholds, adjusted separately by front face potentiometers. The relay will de-energise if one or more voltages between phases are under the value of the minumum threshold or above the value of the maximum threshold. It will also de-energise if the phase sequence is incorrect, the result being indicated as under and overvoltage simultaneously. The device ignores harmonic distortions.

SPECIFICATION Auxiliary supply ............................415, 400, 380, 230, 110, 24 Vac Isolation by transformer Supply tolerance ..........................0.85 to 1.15 U Power consumption .....................3 VA Output relay SPDT AgCdO: Power rating..............................2200 VA, 30 W Switching voltage ......................250 Vac, 250Vdc Max loading...............................10 Aac, 1 Adc Mechanical life ..........................3 107 operations Electrical life..............................2 106 at 2200 VA resistive Phase to phase networks measured: Control Range Input Peak Min & Max Thresholds Resistance Overload 3 220 V 154 to 286 V 250 K 600 V 3 380 V 266 to 494 V 460 K 700 V 3 415 V 290 to 540 V 470 K 800 V AC Supply Phase to neutral networks Using phase to neutral auxiliary supply enables loss of neutral to be monitored. Hysteresis fixed............................3% of the rated value Repeat accuracy ..........................+2% at constant ambient Response time .............................100 ms on make and on break Over and under voltage and sequence ...........................red LED indicators State of relay................................green LED indicator Operating temperature.................10 to +60C Storage temperature ....................10 to +70C Weight ..........................................200g Dimensions ..................................see page 5 Note: The maximum threshold must be greater than the minimum threshold for correct operation.

CONNECTIONS: YWRUPS 11 WRUP.S

Note: The auxiliary supply can be connected between 2 phases of the three-phase network being controlled, limited to 15% of the rated supply.

ORDERING INFORMATION Type Phase to phase DIN rail mounting 11 pin plug-in Supply (3 phases) 3 220 Vac 3 380 Vac 3 400 Vac 3 415 Vac

11WRUPS

380V

110

YWRUPS 11WRUPS

Auxiliary Supply (24 V~, 110 V~, 230 V~, 380 V~, 400V~, 415 V~)

38