Description
The Loop-O9400S ADM/TM is a compact, economic STM1/4 (OC-3/12) ADM & TM Multiplexer designed to add and drop up to: -48 x E1/T1 Tributaries -2 x DS3/E3 Tributaries -1 x GBE and 3 x FE Ethernet Tributaries. With up to 2 aggregate optical/electrical STM-1/4 (OC-3/12) interfaces, the Loop-O9400S can offer the service provider a versatile protection scheme including SNCP and MSP(1+1) protection for both ring and linear network topology. All interfaces are fully compliant with the relevant ETSI standards and ITU recommendations. The Loop-O9400S provides powerful Operation, Administration, Maintenance and Provisioning (OAM&P) functionality, including fault management, performance monitoring, configuration management, and network security management. Through the console port, LAN port, Inband E1 and DCC channel, the OAM&P can be achieved both locally and remotely via SNMP or menu-driven interfaces. Powerful SDH Loops EMS/NMS The Loop-O9400S provides a complete set of operation interfaces that are consistent with the Telecommunication Management Network (TMN) concept (ITU Recommendation M.30,G.784) for SDH/SONET Network Element/Operations System (NE/OS), NE/NE, and NE/Craft communications. Users can easily operate the Loop-O9400S both locally or remotely for centralized management.

Features:
1U TM, ADM, Cross-Connect VC11/VC12/VC3/VC4 cross-connect Aggregate Lines Two Aggregate Lines STM-1/4 (OC-3/12) software configurable (option) Hot Swappable Aggregate Lines. Fixed Tributary Module (option): Up to two 16 E1 tributary modules Up to two E3/DS3 tributary modules Up to one 1 GBE and 3 FE EoS module Protection: SNCP/UPSR protection MSP (1+1) protection for TM Rack mount, wall mount, and stand-alone External/Internal/Line timing with SSM Supports VCAT, LAPS, GFP, and LCAS Intelligent L2 Switch option for Ethernet module to support Ethernet lease line service and virtual LAN. Performance monitoring Alarm suppression, masking, and reporting Full front access option (ETSI) Management: Centralized management with Loops EMS/iNMS over DCC channel VT100 menu-driven EMS LoopView GUI EMS Loop iNMS with Full FCAPS and end-to-end circuit management

CERTIFIED ISO-9001

RoHS Compliance Statement This product complies with DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on the restriction of the use of certain hazardous substances in electrical and electronic equipment, dated 27 January 2003, including ANNNEX.

Ordering Information
Note: All O9400S units, plug-in modules and accessories are RoHS compliant.
To order specify: Model Loop-O9400-S-sdh-opt1-op t2-pp1-pp2-G Accessories Users Manual Loop-O9400-S-UM Power Cord Loop-ACC-PC-USA Loop-ACC-PC-EU Loop-ACC-PC-UK Loop-ACC-PC-AUS Loop-ACC-PC-CH Order wire phone Loop-O9400-S-OW-G SIP Proxy Server Loop-O9400-S-SIP where sdh 8TES4 8E75S4 16TES4 16E75S4 SIP Proxy Server Basic Software is used to select STM type: STM-1/4 engine with 8 T1/E1(120 ohms) on board STM-1/4 engine with 8 E1 (75 ohms) on board STM-1/4 engine with 16 T1/E1(120 ohms) on board STM-1/4 engine with 16 E1 (75 ohms) on board AC power cord for Taiwan/America AC power cord for Europe AC power cord for UK AC power cord for Australia AC power cord for China Order Wire (VoIP) Phone Optional, paper copy of User Manual. A CD version of the manual is already included as standard equipment. Description 1U height shelf with SDH/SONET engine Note

where opt1 and opt2 are used to select optical type: SFP 622M SFP (mini-GBIC) optical housing plug-in card without SFP optical module

Order SFP modules separately from SFP Optical Module Plug-in Table below.

SFP Optical Module Plug-in Table MHBTW Multi mode (mini GBIC) SFP, 155M, 1310nm Commercial 155Mbps (-0+70C), 2Km, LC optical connector PHB3W Single mode (mini GBIC) SFP 155M, 1310nm Commercial (-0+70C), 30Km, LC optical connector PHB5W Single mode (mini GBIC) SFP 155M, 1310nm Commercial (-0+70C), 50Km, LC optical connector PHCUW Single mode (mini GBIC) SFP 155M, 1550nm Commercial (-0+70C), 1550nm, 100Km, LC optical connector PHCXW Single mode (mini GBIC) SFP 155M, 1550nm Commercial (-0+70C), 120Km, LC optical connector PHB3D Single mode (mini GBIC) SFP 155M, 1310nm Commercial (-0+70C), 30Km, LC optical connector with DDM PHB5D Single mode (mini GBIC) SFP 155M, 1310nm Commercial (-0+70C), 1310nm, 50Km, LC optical connector with DDM PHCUD Single mode (mini GBIC) SFP 155M, 1550nm Commercial (-0+70C), 100Km, LC optical connector with DDM PHCXD Single mode (mini GBIC) SFP 155M, 1550nm Commercial (-0+70C), 120Km, LC optical connector with DDM 622Mbps PJB2W Single mode (mini GBIC) SFP, 622M, 1310nm Commercial -0+70C), 15~ 20Km, LC optical connector Single mode (mini GBIC) SFP, 622M, 1310nm Commercial (-0+70C), 40Km, LC optical connector

PJB4W

PJB5W PJC8W PIB1D PJB2D PJB4D PJB5D PJC8D

Single mode (mini GBIC) SFP, 622M, 1310nm Commercial (-0+70C), 50Km, LC optical connector Single mode (mini GBIC) SFP, 622M, 1550nm Commercial (-0+70C), 80Km, LC optical connector Single mode (mini GBIC) SFP, 155-622M, 1310nm Commercial (-0+70C), 15Km, LC optical connector with DDM Single mode (mini GBIC) SFP, 622M, 1310nm Commercial (-0+70C), 15~20Km, LC optical connector with DDM Single mode (mini GBIC) SFP, 622M, 1310nm Commercial (-0+70C), 40Km, LC optical connector with DDM Single mode (mini GBIC) SFP, 622M, 1310nm, 50Km, LC with DDM Single mode (mini GBIC) SFP, 622M, 1550nm Commercial (-0+70C), 80Km, LC optical connector with DDM

where pp1 and pp2 are used to select power supply: P9 Fixed AC/DC power supply (90 to 240 Vac, 50/60Hz, ) / 36-75Vdc

SA

Single AC plug-in power supply module (90 to 240 Vac, 50/60Hz)

SD48

Single DC plug-in power supply module -48 Vdc (36-75)

-Units delivered with the fixed AC/DC option have a built-in power supply module. These units will not accept plug-in power supply modules. -For AC choose an appropriate power cord -Order one power supply only -For AC choose an appropriate power cord Order one power supply only -Can order up to two power supplies

Loop-O9400S STM1/4 PRODUCT SPECIFICATIONS


Uplink - Daughter Board SFP Module Characteristics
SFP Optical Module (155 Mbps) MHBTW PHB3W PHB5W PHCUW PHCXW PHB3D PHB5D PHCUD PHCXD SFP Optical Module (622 Mbps) PJB2W PJB4W PJB5W PJC8W PIB1D PJB2D PJB4D PJB5D PJC8D Fiber Direction dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber Fiber Direction Wavelength (nm) 1310nm 1310nm 1310nm 1550nm 1550nm 1310nm 1310nm 1550nm 1550nm Wavelength (nm) Connector LC LC LC LC LC LC ( with DDM) LC ( with DDM) LC ( with DDM) LC ( with DDM) Connector Distance (Km) 2 30 50 100 120 30 50 100 120 Distance (Km)

dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber dual uni-directional fiber

1310nm 1310nm 1310nm 1550nm 1310nm 1310nm 1310nm 1310nm 1310nm

LC LC LC LC LC ( with DDM) LC ( with DDM) LC ( with DDM) LC ( with DDM) LC ( with DDM)

15-20 40 50 80 15 15-20 40 50 80

Max. Number of Tributary Modules


For 1U shelf: 48 x E1/T1 Tributaries 2 x E3/DS3 Tributaries 1 x GBE and 3 FE Ethernet Tributaries (with switch)

Tributary Modules E1 Interface Line Rate Line Code Input Signal Jitter Output Signal T1 Interface Line Rate Line Code Input Signal Jitter E3 Interface Data Rate Line Code Connector Total Ports DS3 Interface Data Rate Line Code Connector Impedance Ethernet Interface Data Rate Layer2 Protocol Process Protocol System Clock Clock Source (in and out)

2.048 Mbps 50 ppm AMI/HDB3 ITU G.703 ITU G.823 ITU G.703 1.544 Mbps 32 ppm AMI/B8ZS DSX-1 0dB to 6dB w/ALBO ITU G.824

Framing Connector Electrical

Unframed One SCSI-II 68-pin connectors 75 coax/120 twisted pair

Framing Connector Output Signal

Unframed One SCSI-II 68-pin connectors DSX-1 w/short haul (0-133, 133-266, 266-399, 399-533, 533-655 feet)

34.368 Mbps 20ppm HDB3 BNC connector 1

Impedance Framing Output Mask Jitter

75 Ohm Coax Unframed ETS 300 689 Sec.4.2.1.2 ITU G.703 TU G.824

44.736 Mbps 20ppm B3ZS BNC connector 75 Ohm Coax

Framing Output Mask Total Ports Jitter

Unframed Bellcore GR-499-core 1 ITU G.824

10/100/1000Mbps Ethernet VCAT, GFP, LAPS, and LCAS

Connector Mapping Total Ports

RJ-45 connector n x VC12, n x VC11, or n x VC3 4

Internal clock East STM-1/4 Line clock West STM-1/4 Line clock 1 External Clock 3 Tributary clocks

Management LEDs Console port

Telnet SNMP Inband interface Outband interface Diagnostics Test Loopback Test

Multi-color LEDs Electrical: RS232 Connector: DB9S (DCE) Protocol: Menu driven VT-100 Telnet SNMPv1 (RFC1213, RFC2863)

10/100BaseT FE (IEEE 802.3u )


Using 1 E1 Using DCC user selectable 3, 9 or 12 time slots

To optical line To tributary line

Performance Monitor Performance Reports

Performance Parameters: Error Block (EB), Background Block Error (BBE), Errored Second (ES), Bursty Errored Second (BES), Severely Errored Second (SES), Unavailable Second (UAS) System Alarm Alarm Cut Off, Power Loss, TS Sync Loss, SNCP Switch, MSP Switch, Login/Logout SDH Line PI-LOS, RS-LOF, RS-TIM, RS-BIP UAS, MS-SD, MS-SF, MS-AIS, MS-RDI, MS-BIP UAS, MS-REI UAS, LOP-V, AIS-V, SD-V, SF-V

Alarm History

SDH/SONET Line Alarm

Ho-Path

AU-LOP, AU-AIS, P-SD, HP-SF, HP-TIM, HP-UNEQ, HP-PLM, HP-RDI-S, HP-RDI-C, HP-RDI-P, HP-BIP UAS, HP-REI UAS, LOM TU-LOP, TU-AIS, LP-SD, LP-SF, LOS-PI, LOF-S, TIM-S, BIP-S UAS, SD-L , SF-L , AIS-L , RDI-L , BIP-L UAS, REI-L UAS

Lo-Path SONET Line

STS-Path LOP-P, AIS-P, SD-P, SF-P, TIM-P, UNEQ-P, PLMP, RDI-S-P, RDI-C-P, RDI-P-P, BIP-P UAS, REI-P UAS, LOM VT-Path LOP-V, AIS-V, SD-V, SF-V Contains up to 200 alarm records of latest alarm types, alarm severity, date and time.

Alarm Queue Electrical Power (AC) Power (DC) Power Consumption

90 to 240 VAC, 50/60Hz -48 Vdc (36-75V) 18.9 Watts

Physical and Environmental Dimensions for 1U 432 x 44 x 240 mm. (W x H x D) Temperature 0 to 50C Humidity 0-95%RH (non-condensing) Mounting Desk-top stackable, 19 inch rack mountable, and wall mountable Standards Compliance EMC EN55024 EMI EN55022 Class A, 47 CFR Part 15 Subpart B Class A Safety IEC60950

Application Illustration

SDH backbone (STM-16)

STM-1/4 O9400R
0 1 0 1

LOOP INMS

E3/T3 E1/T1 Ethernet


O9400S
0 1 0 1

O9400R
0 1 0 1

O9400R
0 1 0 1

E3/T3 E1/T1 Ethernet


O9100
0 1 0 1

STM-1/4 Ring
O9400S
0 1 0 1

E3/T3 E1/T1 Ethernet STM-1 STM-4

O9400S
0 1 0 1

O9400S
0 1 0 1

O9100
01 0 1

E3/ T3 E1/ T1 Ethernet

O9400S
0 1 0 1

10/100M ethernet Ethernet Switch

10/100M ethernet

E1/ T1

E1/ T1

E1/ T1

E1/ T1 E3/ DS3

xDSL IP- DSLAM

AM-3420

AM- 3440

V4200- 9

V4200- 28

C5500

Loop-O9400S 1U Front Panels

AC Power Supply

Space for Trib Group #1

Space for Trib Group #2

DC Power

Two 1*9 Optical Inerfaces

Space Trib Two 1*9for Optical Group #3 Inerfaces

Space for Trib Group #3

Space for Trib Group #2

LOOP TELECOMMUNICATION INTERNATIONAL, INC.


LoopTelecom.com

Worldwide
8F, No. 8, Hsin Ann Road, Science-Based Industrial Park Hsinchu, Taiwan 300 Tel:+886-3-578-7696 Fax:+886-3-564-6272 www.LoopTelecom.com sales@loop.com.tw

Taipei, Taiwan
2F, No. 40, Section 2, Tuan-Hwa S. Road, Taipei, Taiwan 106 Tel:+886-2-2784-4000 Fax:+886-2-2754-2325

North America
8 Carrick Road Palm Beach Gardens Florida 33418, U.S.A. Tel:+1-561-627-7947 Fax:+1-561-627-6615 jimber561@aol.com

Suzhou China
Tel:+86-512-6252-0456 Fax:+86-512-6252-7641 Sales@looptech.com.cn

Tianjin China
Tel:+86-22-8789-2753 Fax:+86-22-8789-0344 Loop@loop-tj.com

2007 Loop Telecommunication International, Inc. Version 1 23 JUL 2007

All Rights Reserved. Subject to change without notice.

S-ar putea să vă placă și