Counter RRC.FailConnEstab.Cong Sub Counter VS.RRC.Rej.Power.Cong VS.RRC.Rej.UL.CE.Cong VS.RRC.Rej.DL.CE.Cong VS.RRC.Rej.Code.Cong VS.RRC.Rej.ULIUBBandCong VS.RRC.Rej.DLIUBBandCong VS.RRC.Rej.RL.Fail RRC.FailConnEstab.Cong VS.RRC.Rej.AAL2.Fail
VS.RRC.FailConnEstab
RRC.FailConnEstab.NoRepl y
CS RAB Setup
Counter Level1 VS.RAB.FailEstabCS.RNL Sub Counter Level2 VS.RAB.FailEstCS.Unsp Sub CounterLevel3 VS.RAB.FailEstabCS.Cong
PS RAB Setup
Counter Level1 VS.RAB.FailEstPS.RNL Sub Counter Level2 VS.RAB.FailEstPS.Unsp Sub Counter Level3 VS.RAB.FailEstPs.Power.Cong VS.RAB.FailEstPs.Code.Cong VS.RAB.FailEstab.PS.DLIUBBand.Cong VS.RAB.FailEstab.PS.ULIUBBand.Cong VS.RAB.FailEstPs.ULCE.Cong VS.RAB.FailEstPs.DLCE.Cong VS.RAB.FailEstabPS.Unsp.Other
CS Call Drop
Counter Level1 VS.RAB.Loss.CS.RF Sub Counter Level2 VS.RAB.Loss.CS.RF.RLCRst VS.RAB.Loss.CS.RF.ULSync
VS.RAB.Loss.CS.RF VS.RAB.Loss.CS.RF.UuNoReply
VS.RAB.Loss.CS.Abnorm
VS.RAB.Loss.CS.RF.Oth VS.RAB.RelReqCS.OM kalau hardware problem, VS.RAB.Loss.CS.Abnorm incre VS.RAB.RelReqCS.UTRANgen VS.RAB.RelReqCS.RABPreempt VS.RAB.Loss.CS.Aal2Loss VS.RAB.Loss.CS.Congstion.CEL L VS.Call.Drop.CS.Other Sub Counter Level2 Sub Counter Level3 VS.RAB.RelReqPS.OM VS.RAB.RelReqPS.RABPreempt VS.RAB.Loss.PS.GTPULoss VS.RAB.Loss.PS.Congstion.CELL VS.Call.Drop.PS.Other VS.RAB.Loss.PS.RF.RLCRst VS.RAB.Loss.PS.SRBReset VS.RAB.Loss.PS.TRBReset VS.RAB.Loss.PS.RF.ULSync VS.RAB.Loss.PS.RF.UuNoReply VS.RAB.Loss.PS.RF.Oth
PS Call Drop
Counter Level1 VS.RAB.Loss.PS.Abnorm
VS.RAB.Loss.PS.RF
nsp.Other
Abnormal
Subsystem exception
TOP N CellID
M2000/LMT
PRS
LMT
Cell
LMT
Cell
LMT
Cell
PRS
Counter Analysis
TOP Cell
TOP Cell
MR
NASTARV6R8
Top Cell
CHR
CHR
CHR
CM Analysis
PCHR Analysis
CM Analysis
Analysis ActionLevel 1) Analysis ActionLevel 2) IF VS.RAB.RelReqCS.OM ClusterVS.RAB.Loss.CS.Abnorm> 10% VS.RAB.RelReqCS.UTRANgen VS.RAB.RelReqCS.RABPreempt VS.RAB.Loss.CS.Aal2Loss VS.RAB.Loss.CS.Congstion.CELL
VS.Call.Drop.CS.Other if VS.RAB.Loss.CS.RF.Oth>10% Escalate to TS if subsystem CDR > 3%,and Escalate to TS denominator >10000 ; (VS.RAB.Rel.Abnorm.AMR.SPU/ VS.RAB.Rel.Abnorm.AMR.SPU+VS. RAB.Rel.Norm.AMR.SPU) TOP Cell Alarm Check RNC Alarm
NodeB Alarm: i. Cell unavailable ii. Transmission Alarm iii. DSP or CPU alarm iv. Clock alarm or RF alarm Check TOP cell neighbor handover radius Check if RC.AttConnEstab.EmgCall/( RRC.AttConnEstab.OrgConvCall + RRC.AttConnEstab.TmConvCall + RRC.AttConnEstab.EmgCall)>50% [Option]TOP cell transmission configuration change to MOD LOCELL: RADIUS=29000, HORAD=0; check coverage scene
check if AAL2RT or IPRT is configured a)For ATM:E1Test:if AAL2PATH Down or BER>1%,Check transmission quality b)For IP:PingTest: if PacketLoss>1% Check transmission quality NodeB LMT DSP CLKSTAT or LST CLKRECORD
[Option]TOP cell clock check if clock status FREEescalate to RAN/BSS if RTWP (>-96dBm),check according to Interference guideline i check traffic if high ii check if have RF module alarm iii trace RTWP in LMT,compare primary and secondary RTWP to check if internel iiii using LMT frequency scan Functionto check if external interference Check HO_MC_MEAS_BEYOND_UE_CAP_SWITCH (CORRMALOGSWITCH) Check HO_MC_SIGNAL_SWITCH (CORRMALOGSWITCH) if TOP Cell CS HO Prep SR<99%
Check if enable 2G->3G HO,should close SET RRCTRLSWITCH: RSVDPARA1= RsvdBit1_BIT17=0; ClusterVS.RAB.Loss.CS.Abnorm> Escalate to TS 20% Top cell at border of RNCs Check if configure Iur between RNCs,propose configure Iur Check if miss inter RNC cell neighbor check CS HO inter RNC
MR Coverage Analysis
In Nastar Topic Fuction->UMTS Coverage data taskcaculate TOP cell EcNoRSCPTp chart
IOS Aanalyis
Escalated to TS
[option] check if Top N IMSI Escalated to TS drop have same signalling procedure filter if Top 5 IMEI CallDrop Escalated to TS >10%(Total Call Drop) 3 / 0%
0%
a) M2000NodeB DSP b) c) RNC Iub SET DPUCFGDATA FPMDCCOMBINEDELAYVALUE20 ms,FPIub +20ms d) Iub CIO ADD/MOD INTRAFREQNCELL: CIOOffset=10, CIO 0
Analysis ActionLevel 3) Analysis ActionLevel 4) Output Check SOP Alarm info Check Iu Transmission. [Option]Chenk if CS_IUUP_V2_SUPPORT_SWITCH(CORR MALOGSWITCH) matach with CN side TFO/TrFO [Option]Check if security mode is matched between CN and RNC CS&PS.(RNC,SET UEA) Check if CFG_DL_BLIND_DETECTION_SWITCH (CORRMALOGSWITCH) open, and close to monitor Escalate to TS
Action
change to close (0) change to close (0) IF i. check if RNC and IRATHO.FailRelocPrepOutCS.UKno 2GBSC :PLMNLACBSIC wRNC are matched ii. Check if RNC,3G MSC and 2G BSC: PLMNLAC are matced iii. If 2G/3G don't have same MSCcheck if 2G side CN configure 3G LAC IF i. check 2G BSC and CN IRATHO.FailRelocPrepOutCS.Relo if enable 3G HO NoSup or inInter-RAT In BSC IRATHO.FailRelocPrepOutCS.TgtF Handover Enable) ail ii. Check if CNs direction enable check if 2G TCH/SD block rate >1% check if miss 2G Neighbor(better coverage) check if cell-cell neighbor; i. check if RNC side 2G VS.IRATHO.FailOutCS.UEF.N cell info is matched with BSC side ii. Check if 3G to 2G CIO is 0 iii. Check 2GBTS alarm(Clock)
VS.IRATHO.FailOutCS.UEF.N
iv. Check 3GNodeB Clock status, if CS HO relocation <50%, but prepare OK, mostly due to this reason v. check if 2G cell have interference,if interference impact performance RMV GSMNCELL vi. ADD CELLINTERRATHOCOV: TargetRatCsThd=16, Try to improve the TargetRatCsThd. a) check if 3G RNC2G BSC cell security mode is matched.(if 2G no security,SET RRCTRLSWITCH: PROCESSSWITCH=SYS_HO_OU T_CIPHER_SWITCH1&SYS_HO_CIPHER_CONFIG0) [Option]Check 2G cellFrequencyList if correct
a) SET CORRMALGOSWITCH: CmpSwitch=CMP_IUR_SHO_D IVCTRL_SWITCH-1 if NRNC is NSN b) if VS.SHO.FailRLSetupIur.T ransCongRx or VS.SHO.FailRLRecfgIur.C ongTx >20%, check Iur configuration
AttRLAddIur.Tx<99.5%
c) if VS.SHO.FailRLSetupIur.H W.Rx or VS.SHO.FailRLSetupIur.C fgURx >20% ,escalated to TS if VS.SRELOC.SuccExec.UENonInvCS. RNC/VS.SRELOC.AttExec.UENonInv CS.RNC <60%, then SET SRNSR: SrnsRabCnDomainType=NRT (RELOC.SuccPrepUEInvolCS/RELOC .AttPrepUEInvolCS)*(VS.SRELOC. SuccExec.UEInvCS.RNC/VS.SRELOC .AttExec.UEInvCS.RNC)<80% if TOP Cell,MR count(EcNo<14dB or RSCP<110dBm)>20%need RF optimization if TOP Cell (RSCP>-85dBm and EcNo<-14dB)>20%perhapes pilot pollution,need RF optimization
b)
Action Analysis Analysis Action Sub Input MeasResult Subsystem abnormal MeasResult,CFGMML
Tools PRSOMStar
PRSOMStar
Top cell
Top cell
MeasResult
PRSOMStar
MeasResult
PRSOMStar
MeasResult
CHR
PCHRAnalyzer
TM SI(
PCHR Analysis
Tp
EcNo
EcNo
Analysis ActionLevel 1)Analysis ActionLevel 2) If Subsystem RRC SR Escalated to TS <97%denominator> 10000then Subsystem abnormal if Top cell capacity check VS.RRC.FailConnEstab.Con g >10%
if VS.RRC.Rej.RL.Fail>10%
if VS.RRC.Rej.TNL.FailRRC >10%
if VS.RRC.Rej.TNL.FailRRC >10%
20% a) Tp>20
b)
Ec Io<14dB 21 30%
Action
VS.RRC.Rej.ULIUBBandCong a)check NCP/CCP if congestion, expansion VS.RRC.Rej.DLIUBBandCong b)check if configure match with phsical BW; optimize active factor c)change user GBR d)Expansion, PIC BSS VS.RRC.Rej.UL.CE.Cong a) if NodeB dynamic CE enable, try decrease VS.RRC.Rej.DL.CE.Cong GBR(SET USERGBR : UlGBR=D32, DlGBR=D32) b) else expand CE VS.RRC.Rej.Power.Cong a)Check if CELLALGOSWITCH: NBMCacAlgoSwitch=HSDPA_ UU_ADCTRLb) 1) if ul congestion :MOD CELLCAC: UlTotalEqUserNum=140 or more 2) if dl congestion :MOD CELLALGOSWITCH: NBMDlCacAlgoSelSwitch=A LGORITHM_THIRD 3) then, expansion VS.RRC.Rej.Code.Cong if NodeB Dynamic Code,MOD CELLHSDPA set mannual,1 code. Else if RNC Dynamic Code,Mod CELLHSDPA auto,Max 15,Min 1 else expansion TOP Cell Alarm Check RNC Alarm NodeB Alarm: [Option]Check IuB packet a)ATM,Check BER loss b)IP: Check Packet Loss Else Escalate TOP Cell Alarm Check RNC Alarm
TOP Cell Alarm Check NodeB Alarm: Check IUB AAL2PATH or IPPATH configruation Check IuB packet loss
FACH channel congestion: FACHch utl = VS.MAC.CRNCIubBytesFAC H.TxVS.MAC.CRNCIubBytes.PS.C CH.TX*8/((60*<SP>*168* 1/0.01)* VS.PCH.Bandwidth.UsageRa te + (60*<SP>*168*2/0.01)*(1VS.PCH.Bandwidth.UsageRa te)) Interference check
RNC Alarm NodeB Alarm: i. Cell unavailable ii. Transmission Alarm iii. DSP or CPU alarm iv. Clock alarm or RF alarm if Subsystem VS.SPU.CPULOAD.MEAN >60% check if (RRC.AttConnEstab.IRATC elRes/ VS.RRC.AttConnEstab.Cel l) or (IRATHO.AttIncCS/VS.RAB .AttEstabCS.Conv) too high,optimize Reselection or HO else: Expansion if FACHch utl >70% a)if (RRC.AttConnEstab.IRATC elRes/ VS.RRC.AttConnEstab.Cel )>20%,check 2G site down b) add SCCPCH
Sub Input Action Analysis Analysis Action [Option] Security mode check CS_IUUP_V2_S UPPORT_SWITC H check PS+PS Combine License check MeasResult Subsystem abnormal MeasResult
Tools
PRSOMStar
PRSOMStar
MeasResult
PRSOMStar
MeasResult
OMStarM2000
PCHR
TOP
Analysis ActionLevel 1) Analysis ActionLevel 2) Check CS VS PS, CN VS RNC Security mode:(MSC SET MapConfig,SGSN SET PMM ,RNC SET UEA) if matched check if open ,support Iuup ver2Check CN CS_IUUP_V2_SUPPORT_SWIT side if open TFO/TrFO fuction,should be CHSET matched with RNC CORRMALGOSWITCH CNMSC CN check PS+PS License
If Subsystem RRC SR Escalated <97%denominator> 10000then Subsystem abnormal if Top5 cell capacity check VS.RAB.FailEstabCS.Unsp >10%
If VS.RAB.FailEstabCS.TNL
If a) Check Missing Neighbor VS.RAB.FailEstCS.RIPFai lR12: VS.RAB.FailEstabCS.UuFa b) R12 Support ) il>10% VS.RAB.FailEstabCS.RBIncCfg or VS.RAB.FailEstabCS.RBCfgUnsup>5% b) VS.RAB.FailEstCS.RIPFail TOP5 Cell
TOP10IMSI 1 0%
10%
TOP10 IMSI
Action
if (VS.RAB.FailEstabCS.Unsp VS.RAB.FailEstabCS.Con g)>5%, Check AAL2 CID Congestion : if ANIQAAL2.Est.RLC.NoCID.T x or VS.QAAL2.Est.RLC.NoCID.R x>10
if IRATHO.AttIncCS/ VS.RAB.AttEstabCS.Conv >10% if a)check NCP/CCP if VS.RAB.FailEstab.PS.DLIU congestion, expansion BBand.Cong b)check if configure match with phsical BW; VS.RAB.FailEstab.PS.ULIU optimize active factor BBand.Cong c)change user GBR d)Expansion, PIC BSS
i.LST ADJNODE,check adj Node Num ii.LST AAL2PATH,check if local and peer between 2 side. ii. If path configure correct,add new aal2path i. if PATH bandwidth<1.5M,change to actural ii. Else, add new path Disable 2G->3G handover
VS.RAB.FailEstPs.ULCE.Co a) if NodeB dynamic CE ng enable, try decrease GBR(SET USERGBR : VS.RAB.FailEstPs.DLCE.Co UlGBR=D32, DlGBR=D32) ng b) else expand CE VS.RAB.FailEstPs.Power.C a)Check if ong CELLALGOSWITCH: NBMCacAlgoSwitch=HSDPA_ UU_ADCTRL0&HSUPA_UU_ADCTRL0&HSDPA_GBP_MEAS-0) b) 1) if ul congestion :MOD CELLCAC: UlTotalEqUserNum=140 or more 2) if dl congestion :MOD CELLALGOSWITCH: NBMDlCacAlgoSelSwitch=A LGORITHM_THIRD c)Else,expansion VS.RAB.FailEstPs.Code.Co a)SET MACHSPARA: ng DYNCODESW=OPEN; ADD CELLHSDPA: AllocCodeMode=Manual, b)Expansion TOP( RNC SOP
TOP( NodeB i. (FP ) ii. iii. DSPCPU iv. RRC ( )RRC R RC a) ATME1 b) IPIP
Iub
Check Iu-CS AAL2PATH or IPPATH configuration Check Iu-CS if have packet Loss Top cell Alarm Check ,transmission alarm
RNC Alarm NodeB Alarm: i. Cell unavailable ii. Transmission Alarm iii. DSP or CPU alarm alarm
Check Iub AAL2PATH or IPPATH configuration Check IuB if have packet i.ATM,Check BER Loss
Check IuB if have packet Loss ii.IP: Check Packet Loss Rate
Excalated
Interference Check
RNC Alarm NodeB Alarm: i. Cell unavailable ii. Transmission Alarm iii. DSP or CPU alarm iv. Clock alarm or RF alarm RTWP>-90dBm