Sunteți pe pagina 1din 4

TECHNICAL QUOTATION COMPARISON SHEET OPACITY MONITOR PROJECT NO. / PROJECT TITLE: 44PS3600/ 4.

0 MTPA PELLETIZING PLANT, LINE#2

Enquiry Requirement
D T C I M F R O S C E L A N P U T O N L N E I S' A D R . S Y

FOBES MARSHALL

JEI Comments

ROTEX CONTROLS

JEI Comments

DURAG

JEI Comments

1 2 4

Tag Number P&ID No. Service

Manufacturer / Model No.

VTA

FOBES MARSHALL CODEL / Model : DCEM2100 Opacity Monitor

AIT-B05-1008 / AIT-B05-3008 / AT-B02-2063 R-05-1010 / R-05-1011 / R-02-1005 Outlet of Hood Exhaust ESP / Outlet of Windbox Exhaust ESP / B46203T Stack Inlet ROTEX CONTROLS / For AIT-B05-1008 & AIT-B05-3008 : SINTROL E-SPY DUST MONITOR For AT-B02-2063 : S304 Series Dust Monitors Vendor to furnish whether they will provide companion flange for SINTROL E-SPY model and companion connector for S304 Series and there MOC. SINTROL E-SPY DUST MONITOR : DN 80, SS Flange

DURAG / For AIT-B05-1008 & AITB05-3008 : D-R 290 For AT-B02-2063 : D-R 800

Companion Flange

CS

MS

(Refer Note 1)

Vendor to furnish the details whether they are proviiding or not. And its MOC.

Instrument Flange

SS 316

Dicast Aluminium

(Refer Note 1)

S304 Series Dust Monitors : Standard 38 diameter (38mm)

D-R 290 : E flange with tube for mounting measuring Vendor to confirm whether head and reflector, MS the MOC of the flanges, companion connector are D-R 800 : Mounting flange SS316 with 130 mm welding tube, CS

Vendor to provide as per requirement.

Components

VTA

Unique dual beam non contact transmissometer for online Opacity/dust emission monitoring, signal processing unit (SPU), Data Display Unit (DDU), Power Supply Unit.

Measuring probe, power converter, display unit

D-R 290 : Optical measuring unit, reflector, purge air unit, control and display unit. D-R 800 : Measuring lance, Evaluation unit, supply unit with integrated purge air supply

Optical System

VTA

Automatic lens contamination correction for both side optics.

D-R 290 : Super Wide band Diode (SWBD) with life more than 2 years. Electric Induction D-R 800 : In-situ measuring procedure with continuous measurement.

10

Light Source

VTA

High intensity LED D-R 290 : Duct diameter 2 up to 12 m, optional up to 18m. D-R 800 : Duct diameter 1 8 m.

11

Measuring Span

0-100 Mg / Nm3 (0-100% Opacity)

Available

Approx. 0.1 mg/m3 to 1 kg/m3 (particle size >= 0.3 m)

SINTROL E-SPY DUST MONITOR : Information not available. 12 Measuring Range 0-100 % Available S304 Series Dust Monitors : Automatic, based on average measured dust flow during setup procedure) Vendor to furnish details.

D-R 290 : Switchable measuring ranges Opacity : 0-20% to 0-100% Extinction : 0-0.1 to 0-1.6 Dust : 0-100 mg/m3 to 04000 mg/m3 D-R 800 : 0-10 mg/m3, 0200 mg/m3.

Acceptable

13

Cable between Transreceiver and VTA Evaluation Unit

14

Output

4-20 mA DC

10 Mtrs. (Display unit can be mounted upto 1 Km from transreceiver required twin twisted pair overall screened armoured cable which will be in client scope) Available

Vendor to furnish the details.

D-R 290 : 2 Mtrs. D-R 800 : 3 Mtr.

Available

Available D-R 290 : <1% of measuring range Acceptable D-R 800 : <2% of measuring range

15

Accuracy

2 % Opacity

0.2 % Opacity of measurement.

Vendor to furnish the details.

D-R 290 : < 0.1 % 16 Resolution <0.05 % Opacity 0.1 % Opacity Acceptable Vendor to furnish the details. D-R 800 : Information not available. Vendor to furnish the details.

D-R 290 : >= 5 sec 17 Response Time < 10 sec. 5 sec. Acceptable Vendor to furnish the details. D-R 800 : Information not available. Vendor to furnish the details.

18 19

Signal averaging (in minutes) Zero and span calculator

VTA Automatic, at user selectable intervals

10 sec to 30 days selectable Available

Vendor to furnish the details. Vendor to furnish the details.

Vendor to furnish the details. Vendor to furnish the details.

20

Display

4 line by 20 character LCD display

2 line 32 character LCD display

(Refer Note 1)

4 digit LED display (96x48) is inclusive within main instrument unit price, or, 4 line & 20 character LCD display optional with a extra cost of INR 21500 24 VDC (Power converter 230V AC to 24V DC are inclusive within main instrument unit price)

D-R 290 : LCD display (Refer Note 1) D-R 800 : Information not available

Vendor to furnish the details which type of display is providing.

D-R 290 : 95-264 VAC Acceptable D-R 800 : 85-264 VAC D-R 290 : 30VA Acceptable

21

Power Supply

220 VAC, 50 Hz.

Available

22

Power Consumption

VTA

125 VA

Max. 3W D-R 800 : 50 VA D-R 290 : Measuring head IP65, Ex optional Control and display unit : IP 54 D-R 800 : IP 65

23

Protection Class

IP 65, Moisture proof

Available

Vendor to furnish the details.

Acceptable

24 a b

Mounting Instrument Evaluation Unit Flange mounted on stack Flush panel Available but supplied mounting flange needs to be welded on 3" pipe. Available (Wall mounted) Acceptable Acceptable Available Aluminium alloy enclosure Available Available

25

Dimensions

VTA

Signal Processing Unit (SPU) : 200 (L) X 110 (W) X 230 (H) Power Supply Unit (PSU) : 200 (L) X 110 (W) X 230 (H) Data Display Unit (DDU) : 160 (L) X 110 (W) X 160 (H)

SINTROL E-SPY DUST MONITOR : Information not available.

Vendor to furnish details for Sintrol E-Spy Dust D-R 800 : Measuring lance S304 Series Dust Monitor. 160 (H) X 160 (W) X 600 (D) Monitors : / 1000 mm Enclosure - 172.6 (L) X Supply unit : 380 (H) X 300 90 (W) X 173 (H) (W) X 210 (D) mm

D-R 290 : Measuring head 363 (H) X 185 (W) X 398 (D) Control and display unit : 350 (H) X 550 (W) X 500 (D)

26

Weight

VTA

Signal Processing Unit (SPU) : 4 Kg Power Supply Unit (PSU) : 4 Kg Data Display Unit (DDU) : 3 Kg

SINTROL E-SPY DUST MONITOR : Not Vendor to furnish details available. for Sintrol E-Spy Dust Monitor. S304 Series Dust Monitors : 2.3 kg SINTROL E-SPY DUST MONITOR : Not Required Acceptable S304 Series Dust Monitors : Available

D-R 290 : Measuring head 7 kg Control and display unit : 12 kg D-R 800 : Measuting lance 7 kg Supply unit - 13 kg

27

Air Purging Unit

Required

Available (For air purging line vendor recommended to use plant instrument air)

D-R 290 : Available D-R 800 : Available integrated with supply unit. Acceptable

Note 1 : JSPL to Decide.