Product Description INTERBUS Generation 4 controller boards for mounting in 6U racks of VMEbus systems. Features - INTERBUS protocol (DIN E 19258) - Remote bus connection via 9-position D-SUB male connector - Serial diagnostic interface - Networking of up to 4096 sensors and actuators - Up to 512 INTERBUS devices - Up to 255 remote bus devices - Support of Loop devices - Up to 62 PCP devices - Synchronous operating modes - Logical addressing - Group shutdown - System diagnostics through user program - LEDs on the front plate for basic diagnostics - Electrical isolation between remote bus connection and VMEbus system Applications - Adapting INTERBUS to 6U VMEbus systems
5349A001
5349A
3 4 2 5 1 6 7
8
5349A001
4
Figure 2: Layout of the controller board The following components are located on the controller board: 1 2 3 4 5 6 7 8 9 DIP switches VMEbus interface (P1 connector) Holder for the optional plug-in memory card* Ejector Diagnostic display Configuration button Reset button (can be disconnected per DIP switch) Diagnostic interface (9-pos. D-SUB male connector) Remote bus interface (9-pos. D-SUB female connector)
* The memory card is not shipped together with the controller board. 2
5349A
Watchdog The controller board consists of an integrated watchdog circuit that monitors the functioning of the microprocessor (Motorola 68332). When the watchdog responds, a reset of the controller board is initiated. When the controller board starts again, it recognizes that a reset has been initiated by the watchdog before. The function of the watchdog cannot be controlled by the user.
Voltage Monitoring, Reset System The reliable functioning of the controller board requires a sufficiently high operating supply voltage (5 V) via the VMEbus. If the voltage falls below a minimum value, an integrated voltage monitoring circuitry initiates a reset of the controller board. Thus, the outputs of all INTERBUS devices are reset. A reset of the controller board is activated under the following conditions: Response of the voltage monitoring circuitry Reset signal on the VMEbus Pressing of the reset button (can be switched off per DIP switch) Register access to the reset register in the host interface
Mapping the Controller Board to the VMEbus System The controller board is mapped to the VMEbus system via a 256 kbyte Multi-Port Memory (MPM) and via a 16-byte window in the short page. The 256 kbyte Multi-Port Memory (MPM) transfers data between the controller board and the VMEbus system. The registers in the short page are used, for example, to initialize and define the operating modes of the controller board.
5349A
Short-Page Window The controller board uses 16 bytes in the short page. The base address is set with the switches 1 through 8 of switch block S1 and switches 1 through 4 of switch block S2. If you place the controller board in front of you and the system connector is on the top left, the switch positions are identical to that shown in Figure 4.
Short Page 64 kbytes
16 bytes
0 kbytes
5349A003
Only the low-order byte of each of the 8 words is used. This permits a word access to even addresses and a byte access to odd addresses. The meanings of the short-page registers are explained in the user manual (IBS VME SC UM E).
S1
ON ON
S2
1 2 OFF
1 2 OFF
A7 A6
A9
A8
A5
A4 MODE
5111A003
Figure 4: Setting the base address of the short-page registers (all switches are set to OFF by default)
Switches 5 to 8 of switch block S2 have special functions. The MODE switch determines if the supervisor only can access the short-page window (MODE = OFF), or if user and supervisor can access it (MODE=ON). The RESET_EN switch activates the reset button located behind the front plate. The controller board can only be reset with this button if it is in the ON position. The button should be in OFF position for normal system operation. If switch 7 of switch block S2 is in position ON, the controller board automatically changes to TESTMODE after startup. During the test phase (lab operation) the test mode of the controller board can be used to configure any INTERBUS test installation easily and to store it on the optional plug-in memory card (IBS MC FLASH). No I/O data can be transmitted between the host system and the controller board if this mode is active. 4
5349A
Switch 8 of switch block S2 is reserved and its setting should not be changed (default setting upon delivery is OFF). Multi-Port Memory (MPM) Structure The 256 kbyte MPM is the interface to the host system and is divided into several areas. The user can select any address for the start address in the 16 Mbyte address area of the host system: Data Interface: Mailbox Interface: Control Registers: The host system and the controller board exchange the input/output data (process data) of the INTERBUS devices via this area. This interface is used to exchange commands and messages between the host system and the controller board. Several registers for the exchange of status and handshake information between the host system and the controller board.
The controller board defines the locations of the different areas in the MPM with a descriptor. The areas are described in the user manual.
Standard Area 16 Mbytes
256 Kbytes
x + 256 Kbytes
IBS VME6H SC/I-T
reserviert Reserved
0 Mbytes
5349A004
Address Modifier The address modifiers determine with which access method (USER/SUPERVISOR) and to which memory area of the controller board the host system accesses. The controller board supports the following address modifiers: Short User I/O Access Short Supervisory I/O Access User Data Access Supervisory Data Access 29hex 2Dhex 39hex 3Dhex
5349A
5349A
Interfaces
Serial Interface (RS-232) The controller boards serial interface (RS-232) connects an IBM-compatible PC with the IBS CMD SWT G4 E software (Order No.: 27 21 44 2). This software can be used to configure, parameterize and diagnose the INTERBUS system. IBS CMD SWT G4 is independent of the programming language or of the operating system of the VMEbus system. Parameterization and configuration information can be stored on the controller boards memory card (accessory part) with IBS CMD SWT G4. In addition, the firmware of the controller board can be downloaded. The serial interface on the front plate of the controller board has been designed as a 9-pos. D-SUB male connector. The controller board is connected to the PC via the IBS PRG CAB cable (Order No.: 28 06 86 2) shown below.
Front plate
2 3 5 7 8
TXD RXD GND RTS CTS
Pin side
5 9
Connecting cable
Solder side
5 9
Solder side
2 3 5
2 3 5
6 9
Remote Bus Interface (REMOTE) The remote bus interface connects the controller board with the INTERBUS devices (field devices). The remote bus interface has been designed as a 9-pos. D-SUB female connector on the front plate of the controller board. Phoenix Contact offers preassembled remote bus cables in common lengths. The design of the remote bus cable is shown in the figure below. In addition, the OPTOSUB-PLUS... interface connector allows you to fit your INTERBUS system with optical fibers.
Front plate
DO DO DI DI COM +5V RBST GND Vcc 6 1 7 2 3 5 9 4 8
Socket side Solder side
Solder side
6 9
5349A006
Figure 7: Remote bus interface and example for a remote bus cable (cable type D9/D9)
5349A
Technical Data Designation IBS VME6H SC/I-T 6U controller board for VMEbus systems Space required: 1 slot VDE 0110 part1, 01/89, VDE 0160 05/88 From 0C to +55C From -25C to +85C P1 connectors to VMEbus system (C96 connector acc. to DIN 41612) D-SUB female connector (9-pos.) for remote bus D-SUB male connector (9-pos.) +5V DC (residual ripple 0.1 Vpp) 3.1 W typical Up to 4096 Up to 512 Up to 255 Up to 62 A16/D16 16 bytes A24/D16 256 kbytes
Air and creepage distances Permissible operating temperature Permissible storage temperature Connectors INTERBUS interface Diagnostic interface Operating voltage Power consumption Sensors and actuators INTERBUS devices Remote bus device PCP devices VMEbus interface
Table 1:
Ordering data for the controller board and its accessories Order Designation IBS VME6H SC SYSKIT E IBS VME6H SC/I-T IBS VME SC UM E IBS MC FLASH IBS CMD SWT G4 E IBS PRG CAB IBS VME DDK E IBS SYS PRO UM E IBS SYS INST UM E OPTOSUB-PLUS-K/OUT OPTOSUB-PLUS-G/OUT Order No. 27 23 27 5 27 22 85 2 27 51 08 5 27 51 77 1 27 21 44 2 28 06 86 2 27 23 87 7 27 51 00 1 27 54 80 4 27 99 61 0 27 99 63 6
Description System package VME6H SC Controller board User manual including OS9 driver software Memory card Operating software for PCs Connecting cable (controller board <--> PC) Device Driver Development Kit Project Planning Manual for INTERBUS Installation Manual for INTERBUS Fiber-optics interface connector for the REMOTE interface, polymer fiber Fiber-optics interface connector for the REMOTE interface, glass fiber
5349A
Phoenix Contact GmbH & Co. Postfach 13 41 32819 Blomberg Germany Phone: + 49 - (0) 52 35 - 3-00 Fax: + 49 - (0) 52 35 - 3-4 12 00
TNR 93 55 19 6