CHEAT SHEET
–+ 2 dB –+ 2 dB –+ 2 dB –+ 1 dB
SENSITIVITY RANGE
Launch -15
REQUIRED Rx
Power Worst -3 dB –+ 0 dB
-20 Hot -2 dB
-4 dB/km
-25
-30 -3 dB
-35
Figure A. Short fiber jumper cable
connected between the light source
and the power meter DECIBEL TO POWER CONVERSION
Just a few dB of loss equates to a large percentage of light that’s wasted — which can negatively affect your
signal transmission.
Power Out Power Out
Loss as a % of Loss as a % of
dB Power In % of Power Lost Remarks dB Power In % of Power Lost Remarks
6 25.0% 75.0% 1/4 the power 18 1.6% 98.4% 1/60 the power
7 20.0% 80.0% 1/5 the power 19 1.3% 98.7% 1/80 the power
8 16.0% 84.0% 1/6 the power 20 1.0% 99.0% 1/100 the power
A 3 dB loss means that 50 percent 9 12.0% 88.0% 1/8 the power 25 0.3% 99.7% 1/300 the power
10 10.0% 90.0% 1/10 the power 30 0.1% 99.9% 1/1,000 the power
of the light is lost, whether modulated 11 8.0% 92.0% 1/12 the power 40 0.01% 99.99% 1/10,000 the power
12 6.3% 93.7% 1/16 the power 50 0.0% 100.0% 1/100,000 the power
at 10 Hz or 100 MHz.
SOURCES: COMMUNICATIONS SPECIALTIES, EMCORE CORP.