Documente Academic
Documente Profesional
Documente Cultură
18
756
(kg/m3)
998.919
998.758
998.484
(kg/m-s)
0.0011264
0.0010997
0.0010614
Pv (Pa)
1818.8
1938.4
2131.5
0.5
3450
60
0.8
32-125-0,5
HIDROSTAL
SUCCION DESCARGA
2
1.5
5.25
4.09
0.265
1.223
HIERRO FORJADO
0.047
0.592
Largo (m)
0.59
Ancho (m)
0.59
rea (m )
0.348
K
0.7
VLVULA DE COMPUERTA
0.15
t (s) H (m)
10.34 0.1
10.74 0.1
11.23 0.1
12.25 0.1
13.55 0.1
15.98 0.1
29.82 0.1
Q (m3/s)
0.003367
0.003241
0.0031
0.002842
0.002569
0.002178
0.001167
TABLA N8: Datos del tiempo variando la vlvula de descarga Abrir la vlvula
de descarga
Corrida
1
2
3
4
5
6
7
t (s)
13.32
11.68
11.51
10.76
10.75
10.34
10.14
H (m)
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Q(m3/s)
0.002613
0.00298
0.003024
0.003235
0.003238
0.003367
0.003433
t (s)
10.58
11.4
11.52
12.92
14.73
18.29
18.84
H (m)
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Q(m3/s)
0.00329
0.003054
0.003022
0.002694
0.002363
0.001903
0.001848
Pdescarga
(psi)
3.8
3.6
3.8
3.2
3
2.6
1.8
Psuccin
(pulg. Hg)
5.5
6
6.75
8.8
10
12
15
Intensidad
(A)
3.8
3.6
3.8
3.8
3.8
3
3.2
Voltaje
(V)
220
220
220
220
220
220
220
Pdescarga
(psi)
3.1
3.6
3.8
4.2
4
4
4.2
Psuccin Intensidad
(pulg. Hg)
(A)
9.5
4
7.5
4
6.75
4
6.5
3.9
6
4
5.5
4.2
5.25
4.4
Voltaje
(V)
220
220
220
220
220
220
220
Pdescarga
(psi)
4.2
3.8
3.6
3.2
2.8
2.5
2.4
Psuccin
(pulg. Hg)
5.5
6.5
7.5
9.5
11
13
13.25
Intensidad
(A)
4.2
4.2
4.2
4
4
3.8
3.6
Voltaje
(V)
220
220
220
220
220
220
220
II.
TABLAS DE RESULTADOS
TABLA N13: Velocidad de succin (Vs) y velocidad de descarga (Vd) Cerrar
la vlvula de descarga
Corrida
1
2
3
4
5
6
7
Q (m3/s)
0.003367
0.003241
0.0031
0.002842
0.002569
0.002178
0.001167
Vs (m/s)
1.5554
1.4972
1.432
1.3129
1.1867
1.0061
0.5391
Vd (m/s)
2.564
2.4681
2.3607
2.1642
1.9563
1.6586
0.8887
Q (m3/s)
0.002613
0.00298
0.003024
0.003235
0.003238
0.003367
0.003433
V s (m/s)
1.2071
1.3766
1.3969
1.4944
1.4958
1.5554
1.5859
V d (m/s)
1.9898
2.2693
2.3028
2.4635
2.4658
2.564
2.6143
Q (m3/s)
0.00329
0.003054
0.003022
0.002694
0.002363
0.001903
0.001848
Vs (m/s)
1.5198
1.4108
1.396
1.2445
1.0916
0.8791
0.8537
Vd (m/s)
2.5054
2.3257
2.3013
2.0515
1.7994
1.4492
1.4073
Re succin
72442
69732
66695
61148
55270
46859
25108
Re descarga
93009
89531
85635
78507
70965
60166
32238
f succin
0.0226
0.0227
0.0228
0.0231
0.0234
0.0240
0.0266
Corrida
1
2
3
4
5
6
7
Re succin
56220
64115
65060
69601
69667
72442
73863
Re descarga
72180
82319
83534
89364
89447
93009
94834
fsuccin
0.0234
0.0230
0.0229
0.0227
0.0227
0.0226
0.0226
hf descarga (m)
0.1413
0.1813
0.1865
0.2120
0.2124
0.2288
0.2375
Re succin
70784
65708
65018
57962
50841
40944
39761
Re descarga
90884
84365
83480
74418
65273
52570
51050
fsuccin
0.0227
0.0229
0.0229
0.0233
0.0237
0.0245
0.0246
f descarga
0.0229
0.0230
0.0231
0.0233
0.0237
0.0243
0.0244
Q (m3/s)
0.003367
0.003241
0.0031
0.002842
0.002569
0.002178
0.001167
H (m)
6.8606
7.1107
7.6725
8.8472
9.5642
10.7596
12.4576
Corrida
1
2
3
4
5
6
7
Q (m3/s)
0.002613
0.00298
0.003024
0.003235
0.003238
0.003367
0.003433
H (m)
9.2572
8.1034
7.6552
7.6693
7.2491
6.9305
6.8413
Corrida
1
2
3
4
5
6
7
Q (m3/s)
0.00329
0.003054
0.003022
0.002694
0.002363
0.001903
0.001848
H (m)
6.9811
7.488
8.1151
9.3109
10.1623
11.3882
11.5214
Corrida
1
2
3
4
5
6
7
f succin
0.0226
0.0227
0.0228
0.0231
0.0234
0.0240
0.0266
hf (m)
0.1825
0.1695
0.1554
0.1312
0.1078
0.0783
0.0236
NPSH D
9.551
9.573
9.597
9.638
9.677
9.727
9.819
Corrida
1
2
3
4
5
6
7
f succin
0.0234
0.0230
0.0229
0.0227
0.0227
0.0226
0.0226
hf (m)
0.1115
0.1439
0.1481
0.1688
0.1692
0.1825
0.1896
NPSH D
9.671
9.616
9.609
9.574
9.574
9.551
9.539
f succin
0.0227
0.0229
0.0229
0.0233
0.0237
0.0245
0.0246
hf (m)
0.1745
0.1509
0.1479
0.1183
0.0917
0.0603
0.0570
NPSH D
9.565
9.605
9.610
9.660
9.705
9.757
9.763
NPSH R
1.5165
1.4782
1.4348
1.3537
1.2651
1.1326
0.7456
Q (m3/s)
0.0026
0.0030
0.0030
0.0032
0.0032
0.0034
0.0034
NPSH R
1.2796
1.3974
1.4112
1.4764
1.4773
1.5165
1.5363
Q (m3/s)
0.0033
0.0031
0.0030
0.0027
0.0024
0.0019
0.0018
NPSH R
1.4932
1.4205
1.4105
1.3060
1.1962
1.0347
1.0146
TABLA N28: Potencia til (HPH), potencia real (BHP) y eficiencia Cerrar la
vlvula de descarga
Corrida P til (W) P real (W)
1
0.2264
0.669
2
0.2258
0.634
3
0.2331
0.669
4
0.2464
0.669
5
0.2408
0.669
6
0.2296
0.528
7
0.1425
0.563
n (%)
33.85
35.64
34.85
36.84
36.00
43.49
25.30
TABLA N29: Potencia til (HPH), potencia real (BHP) y eficiencia abrir la
vlvula de descarga
Corrida
1
2
3
4
5
6
7
n (%)
33.66
33.61
32.22
35.41
32.67
30.93
29.72
TABLA N30: Potencia til (HPH), Potencia real (BHP) y eficiencia Cerrar la
vlvula de descarga (segunda vez)
Corrida P til (W) P real (W)
1
0.2250
0.739
2
0.2240
0.739
3
0.2402
0.739
4
0.2457
0.704
5
0.2352
0.704
6
0.2123
0.669
7
0.2086
0.634
n (%)
30.43
30.30
32.50
34.90
33.41
31.74
32.92