HE-67xx Series
Features
TRUERH circuitry and calibration techniques for which patent protection is pending
Selection Charts
HE-67xx Series Wall Mount Models Code Number Description RH Accuracy 2% 3%
HE-67P2-0N0BT HE-67S2-0N0BT HE-67N2-0N0BT HE-67P3-0N0BT HE-67S3-0N0BT HE-67N3-0N0BT
1
RH Accuracy 2% 3%
Wall mount humidity element with thin-film platinum temperature sensor Wall mount humidity element with silicon temperature sensor Wall mount humidity element with thin-film nickel temperature sensor Wall mount humidity element with thin-film platinum temperature sensor Wall mount humidity element with silicon temperature sensor Wall mount humidity element with thin-film nickel temperature sensor
Duct probe humidity element with thin-film platinum temperature sensor Duct probe humidity element with silicon temperature sensor Duct probe humidity element with thin-film nickel temperature sensor Duct probe humidity element with thin-film platinum temperature sensor Duct probe humidity element with silicon temperature sensor Duct probe humidity element with thin-film nickel temperature sensor
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. www.johnsoncontrols.com Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2009 Johnson Controls, Inc.
1 of 2
0.1 to 0.05% RH/C at 5C (41F) to -0.07 to -0.21% RH/C at 65C (149F) Within 5% RH of actual in 15 minutes for 10 to 30%, 30 to 90%, and 40 to 90% RH Accuracy: 0.34F (0.18C) at 70F (21C) Reference Resistance: 1000 ohms at 70F (21C) Resistance Change: Approximately 3 ohms/F (5 ohms/C) Accuracy: 1F (0.6C) at 70F (21C) Reference Resistance: 1035 ohms at 77F (25C) Resistance Change: Approximately 4 ohms/F (8 ohms/C) Accuracy: 0.65F at 70F (0.36C at 21C) Reference Resistance: 1000 ohms at 32F (0C) Resistance Change: Approximately 2 ohms/F (4 ohms/C) 3-position and 2-position screw terminal blocks 32 to 140F (0 to 60C) 0 to 100% RH, 85F (29.4C) maximum dew point -20 to 140F (-29 to 60C) 0 to 100% RH, 85F (29.4C) maximum dew point -40 to 140F (-40 to 60C) 0 to 100% RH, 85F (29.4C) maximum dew point
Silicon
Thin-film Platinum
Electrical Connections Ambient Operating Conditions Survival Operating Conditions Ambient Storage Conditions Materials Dimensions Wall Mount Duct Probe Wall Mount (H x W x D) Duct Probe (H x W x D) Agency Compliance Duct Probe Material
Beige plastic cover with metal base and metal foil face plates White plastic cover with dark gray plastic housing and probe 1.81 x 2.12 x 3.12 in. (46 x 54 x 79 mm) 3.28 x 3.25 x 8.27 in. (83 x 83 x 210 mm) Probe (L x D): 6.25 x 0.98 in. (159 x 25 mm) 94-5V flammability rated per UL 94
3.28 83
3.25 83 2.02 51
2.12 54
3.12 79
he67xx_ts_4p.eps
1.81 46
Diameter 0.98 25
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. www.johnsoncontrols.com Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2009 Johnson Controls, Inc.
2 of 2
he67xx_ts_5p.eps
6.25 159