Sunteți pe pagina 1din 7

( Reaffirmed 1997 )

I6:8008(PartVI)-1976

Indian Standard
SPECIFICATION FOR INJECTION MOULDED HIGH DENSITY POLYETHYLENE ( HDPE ) FITTINGS FOR POTABLE WATER SUPPLIES
PART VI SPECIFIC REQUIREMENTS PIPE ENDS and Water FOR

Sanitary

Appliances
chainnan

Fittings Sectional Committee,


Represmling
Corporation

BDC 3

SEW V. D. DESAI

Bombay Municipal

MCfllbnJ
Ministry of Health ADVISES Indian Iron & Steel Co Ltd, Calcutta SEBI H. R. BADYAL SHRI K. D. BISWU ( Allemule ) Ministry of Railways SERI V. D. CHADHA Cent;Jork:iilding Research Institute SEEI S. P. CHAERABABTI
CHEF

( CSIR ),

Sam S. K. SHABMA ( Altena~c ) Central Public Works Department, New Delhi ENQINEEB SVPEBINTENDINQ ENC+INEEB ( Altcmotc) Loca~u~;~~wGovernment Engineering Department, CEIEB ENQINEEB SUFE~INTENDINOENGINEER ( Alfernqtc ) Tam$aFAu CHIEB ENQINEEB
CHIEF

Water

Supply

&

Drainage

Board,

Municipal Corporation of Delhi ENQINEER (WATER ) DRAINAQE ENQINEEB ( Altmatc ) Bombay Municipal Corporation CITY ENQINE~~ HYDRAULIC ENQINEE~ ( Altcrnatc ) Indian Institute of Architects, Bombay SHRI H. N. DALLAS National Test House, Calcutta LALA G. C. DAS Directorate General of Supplies & Disposals SHRI M. T. KINSIB Delhi Development Authority SHEI S. C. KAPOOR Central Glass & Ceramic Research Institute SHRI R. V. LELE ( CSIR ), Calcutta National Environmental Engineering Research PBOF N. MAJUMDEI~ Institute ( CSIR), Nagpur SRRI J. M. DA= ( Ahm& ) ( Conrinued on pogc 2 ) @ Co&right 1982 STANDARDS INSTITUTION

INDIAN

This publication is protected under the Zndiun Copyright Act ( XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Acf: I

IS: 8096 (Part


( htinued fiomfige
M&S

VI)-1976
1)
&pmmting

Directorate General of Technical Development SHBX R. N. MALLICK SHRI N. R. SRWIVA.SA~ ( Altern& ) Bombay Potteries & Tiles Ltd, Bombay SHXI R. M. MEERA Public Health Engineering Department, Government SHBI D. APPUKUTTAN NAYAB of Kerala, Trivandrum SHRI K. RAMAOEANDRAN ( Altematr ) Engineer-in-Chiefs Branch, Army Headquarters %L RAJ KWAR SERI I. S. BED: ( A&mote ) Public Health Engineering Department, Government Snnr P. S. RAJVANSEI of Rajasrhan, Jaipur National Buildings Organization, New Delhi DE A. V. R. RAO Snar G. T. BHIDE ( Aitcrnalr ) E. I. D.-Parry Ltd, Madras SEBI P. JAQANATE RAO SHEI T. S. CEINTAMANI ( Altnnofr ) Institution of Engineers ( India ), Calcutta +.%a~ B. B. RAW Public Health Engineering Department, GovernSERI J. L. S~XHI ment of Haryana, Chandigarh SHRI A. N. MEHANDAL~ ( Alkmafr ) Sanitaryware & Industries Ltd. Hindustan Sa~r R. K. Soaaatrv Bahadurgarh Ssar V. S. BHA.?T ( Ahmote ) Director General, IS1 ( fi-o&io Mcmbn ) SHRI D. AJITTHASIYHA, Director ( Civ Engg ) Secrcfary SHB~ S. P. MAWU Assistant Director ( Civ Engg ), ISI

Plastic Pipes Subcommittee,


Convene7 SHB1K.D.
hkiLmnB

BDC 3 : 8
Corporation

Bombay

Municipal

Shri K. D. hlulekar ) ADVIEEB Ministry of Health SERI V. A. ANANDADO~S ( Alttmate) DB B. R. C. ANAND Calico Chemicals, Plastics and Fibres Division, Bombay SHBI S. MITRA ( Altcrnafc ) SHB~ P. M. APTE Housing & Urban Development Corporation Ltd. New Delhi SHEI B. K. CEAKBABARTY ( Alternate ) SEBI H. R. BUTAXI Garware Plastics (Pvt ) Ltd, Bombay SEBI B. K. CHAWLA ( Altematr ) SHXI S. S. CHHEDA Manufacturers Association, Bombay

Members SRRI S. H. MEATRE ( Akrnafr to

*He is also alternate

to Adviser,

Ministry

of Health.

IS : 8008 ( Part

VI) -1976

Indian Standard
SPECIFICATION FOR INJECTION MOULDED HIGH DENSITY POLYETHYLENE ( HDPE) FITTINGS FOR POTABLE WATER SUPPLIES
PART VI SPECIFIC REQUIREMENTS PIPE ENDS FOR

0.

FOREWORD

0.1 This Indian Standard ( Part VI) was adopted by the Indian Standards Institution on 26 February 1976, after the draft finalized by the Sanitary Appliances and Water Fittings Sectional Committee had been approved by the Civil Engineering Division Council. 0.2 The injection moulded HDPE fittings are used for connection, welding process, to HDPE pipes covered by IS : 4984-1972*. by

0.3 The requirements of injection moulded HDPE fittings are covered in seven parts of the standard as given on the fourth cover page. Part I of the series deals with the general requirements applicable to all HDPE fittings and specific requirements of different types of fittings are covered in separate parts of the standard. This Part VI deals with specific requirements for pipe ends. 0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS : 2-19607. The number of significant places retained in the rounded off value should he the same as that of the specified value in this standard.

1. SCOPE 1.1 This standard (Part VI) lays down the requirements for manufacture, dimensions and tolerances, and marking for injection moulded pipe ends made of HDPE for potable water supplies.
*Specification for high density polyethylene pipes for potable

( first reuision ).

I#

water

supplies

TRules for rounding off numerical values ( ret&d ).

ISx8998(Part

VI)-1976

2. REQUIREMENTS 2.1 General - The general requirements for mate&$, manufacture, methods of test, sampling and inspection shall conform to IS: 8008 ( Part I )-1976*. 2.2 Manufacture 23.1 A typical illustration of pipe end is shown in Fig. 1. overall dimensions of pipe end with those given in Table 1 read

2.2.2 Dimensions and Tolerances-The and tolerances thereon shall comply with Fig. 1.

FIG. 1

PIPE END

2.2.3 The outside diameter and wall thickness of the end t.o be welded to pipe shall comply with the requirements given in IS : 8008 ( Part I)197ti*. 3. MARKING 3.1 L information:

Each pip-end fitting shall be marked with the following


a) Manufacturers b) The size of name or identification the fitting and the mark, and appropriate

pressure ) to which the pressure rating of,the

class ( working fitting corresponds.

*Specification fof injection moulded high density polyethylene ( HDPE ) @in@ for potable water supplles : Part I General requirements. 1~
4

ES: 8008 ( Part VI ) - X976


TABLE 1 OVERALL Slza (1) mm
20

QIMENSIONS

AND TOLERANCES 1)

FOB

PIPE

BNDS

( Clazr~ 2.2.2, and Fig. .z (2) mm 16 f 1.5 16 + 1.5 16 * 1.5 16 & 1.5 20r1.5 2Of 20 * 25 f 30 f 30 f 35 f 50 f 1.5 1.5 1.5 1.5 1.5 1.5 1.5 h (3) mm 5 f

(f) mm 50 f 56 f 1 1

0.5

25 32 40 50 63 75 90 110 125 146 160 180 200 22 5 $1.1 Each pipe-end Certification Mark.

5 _I 0.5 5 f 0.5 5 f 0.5

65 f 1 70 & I 80 -& 1.5 95 * 105 f 125 f 155 f 188 f 1.5 1.5 2 2 2

10 & 1
10 f 10 * 12* 15 f 15* 15 f 20 f 20 f 30 f 30 f 1 1

1
1 1 1 1.5 l-5 2 2

30 & 1.5 35 f. 1.5 50 3: 1.5

168 & 2 215 + 2 24oj,2 240 f 270 f 2 2

fitting

may

alsa

be

marked

with

the

IS1

NOTE - The use of the IS1 Certification Mark is governed by the provisions of the Indian Standards Institution ( Certification Marks) Act and the Rules and ReguThe ISI Mark on products covered by an Indian Standard lations made thereunder. conveys the assurance that they have been produced to comply with the requirements of that standard under a well-defined system of inspection, testing and quality control which is devised and supervised by ISI and operated by the producer. IS1 marked product? are also continuousl, 3 checked by IS1 for conformity to that standard. as a further safeguard. Details of conditions under which a licence for the use of the ISI Certification Mark may be granted to manufacturers or processors, may be obtained from the Indian Standards Institution.

IS I 8008( Part VI ) - 1976


( Continued from pngr 2 ) MHTlbCrS CHIEE ENSXIUTEB SUPEBINTENDIN~ ENGINEEE CEIE~ ENQIN~ER
(

f&pesentin# Local Self Government Engineering Department, Lucknow Alt.mntc ) Tamil Nadu Water Supply & Drainage Board, Madras Municipal Corporation of Delhi Research ( P ) Ltd, ( CSIR ),

CHIEF ENOINEEB ( WATER ) DEPUTY CHIEF EN~XNEEB ( WATEB ) ( Atcnvltc ) National Environmental Engineermg Sam J. M. DARE Institute, Nagpur SHBI R. PARAMA~IVAM ( Ahnate ) EMCO General ( Plastic ) Industries SHEI S. K. DEY Calcutta Centraiorkveilding Research Institute Sam R. K. JAIN SEEI S. P. CHAKRAeABTl SERI K. K. KAMATB SESI A. R. KANQA
SBRI A. E. LADH~BEIOY

( Altcmatc )

DB S. L. KAPUT

DE V. B. V. RAJAN (Alternate) ~trnr U. S. MAJMUNDAR Union Carbide India Ltd, Calcutta SHRI S. P. KHIJRANA ( Alternate ) Directorate General of Technical Development SERI R. P_4RIKSHIT Central Public Works Department Sam G. S. RAO SHRI K. C. S. RAO Ministry of Defence MAJ S. K. AQQARWAL ( Ahm~tc ) Polyolefins Industries Ltd, Bombay SHRI P. B. RAO National Buildings Orgamzation, New Delhi SERI 0. P. RATRA Public Health Engineering Department, Gove-mREPBESENTATIVE ment of Haryana, Chandigarh Chemicals & Plastics ( India ) Ltd, Madras SBRI R. SIVARAMAKBI~ENAN S&I R. KALIDAS ( Alfern& ) Wavin India Ltd, Madras Srxn~G. K. SRINIVASAN Sam K. R. RANQABAJAN ( Altrntntr )

Public Health Engineering Department, Government of Kerala, Trivandrum Citv & Industrial Development Corporation Ltd, Bombay National Chemical Laboratory ( CSIR ), Pune Imperial Chemical Industries (India) Ltd, Calcutta

S-ar putea să vă placă și