Sunteți pe pagina 1din 12

The Science of Compresse d Air

QUINCY AIR SYSTEMS FILTERS COALESCERS ABSORBERS ELEMENTS

C O M P R E S S E D A I R F I LT E R S
Quincy Filters protect pneumatic equipment and processes from the harmful effects of contaminated compressed air by removing dirty water, burnt oil and solid pollutants before they can do any damage. Clean compressed air will result in improved production and reduced operating costs. World class, state-of-the-art material and design make Quincy Compressed Air Filters the standard to which all others must be compared.

S TA N D A R D F I LT E R S
Partic u late Coalescer Absorber

Our Standard Filtration lineup consists of the three most common types of filters used in compressed air systems.
THE QUINCY DCN SERIES

B R E AT H A B L E A I R S Y S T E M S F O R PA I N T O R S A N D B L A S T A P P L I C AT I O N S
(Will not remove certain types of gases, including CO or CO2 )

15 cfm two-port ma n ifold 30 scfm, fo u r-port ma n ifold 230 psig max. worki n g press u re Floor sta n d or wallmo un ti n g brackets Air press u re reg u lator Air press u re ga u ge Available air heater

Particulate/Coarse Coalescer is designed to remove solids, burnt oil and bulk liquids.
THE CSN, CPN, CXN SERIES

Coalescers remove various levels of liquid aerosols and mist.


THE ACN SERIES

H I G H - T E M P E R AT U R E D U S T F I LT E R

Activated Carbon Absorbers remove vapors and odors.


+450F/150 psig 15 to 1600 scfm

10 scfm to 16,500 scfm 230 psig max. worki n g press u re for threaded filters 150 psig max. worki n g press u re for fla n ged filters Al u mi nu m ho u si n g ( 12" to 3" NPT) Steel ho u si n g (3" to 12" FLG)

M O I S T U R E S E PA R AT O R S

20 to 1500 scfm, 230 psig Al u mi nu m ho u si n g ( 14" to 3" NPT)

OVER & UNDER COALESCER/ABSORBER C O M B I N AT I O N


10 to 50 scfm/230 psig Two-i n -o n e desig n

QuincyCompressor.com
2

Ma d e in the U.S.A.

The Science of Compresse d Air

The Science of Air Treatment

ELEMENTS Quincys Layered Multiwrap design employs a specially blended borosilicate glass microfiber media to produce strong, durable and efficient filter elements. The filtration media combines high flow rates and high dirt-holding capacities without compromising element service life. Easy to identify and easy to install, these highly advanced products offer the best performance available

ELEMENT CONSTRUCTION
Push-to-Fit Design Aluminum Filters

Polyester Needle Felt Drainage Layer


Easy eleme n t replaceme n t Fit i n tegrity elimi n ates leaks, savi n g e n ergy

Optim u m oil removal High temperat u re tolera n ce Maxim u m d u rability Will n ot disi n tegrate S u itable for u se with mi n eral a n d sy n thetic oils Tolera n t i n aggressive e n viro n me n ts

Stainless Steel Support Core


Provides stre n gth Elimi n ates corrosio n Protects eleme n t from b u rsti n g un der high differe n tial press u re
st

Glass-Filled Nylon End Caps

1 Stage Pre-Filtration Support Layer


Capt u res larger co n tami n ates Protects 2 nd Stage filtratio n media Exte n ds service life

Color-coded for simple eleme n t grade ide n tificatio n Easy eleme n t replaceme n t Will n ot corrode

Multiwrap 2nd Stage

High void vol u me mi n imizes press u re drop, savi n g e n ergy I n creased s u rface area e n s u res maxim u m co n tami n a n t rete n tio n Exte n ded life co n str u ctio n Deep bed provides optim u m coalesci n g efficie n cy Selected media combi n atio n s provide precise filtratio n sol u tio n s

3rd Stage Interceptor Layer


Provides additio n al stre n gth Optimizes i n terceptio n process

4th Stage Outer Stainless Steel Support

E n s u res total eleme n t i n tegrity

Inside to Out Flow

Prolo n gs eleme n t life a n d improves drai n performa n ce

C O M P R E S S E D A I R F I LT E R S
STANDARD LINE PARTICULATE COALESCER ABSORBER Quincys Standard Filtration lineup consists of the three most common types of filters used in compressed air systems. Aluminum housings with threaded NPT connections are used for flows up to 1530 cfm and steel housings with flanged connections are used for flows up to 16,500 cfm.

Push-to-fit design used on threaded filters for easy filter element replacement Multiwrap element construction ensures optimum performance Modular design saves energy and allows for easy installation of multiple threaded filters Aluminum housings feature electrophoretic coating to prevent corrosion 10-year housing guarantee on aluminum housings Standard pressure differential indicator Standard automatic condensate drain

ALUMINUM HOUSINGS, THREADED CONNECTIONS 10 TO 1530 CFM


DCNT SERIES

CSNT, CPNT, CXNT SERIES

ACNT SERIES

Desig n ed to remove high co n ce n tratio n s of solids, b u r n t oil a n d b u lk li qu ids DCNT 5 micro n , 5 ppm

Desig n ed to coalesce vario u s levels of li qu id aerosols. The 1 micron CSN is also an ideal afterfilter for desiccant dryers. CSNT 1 micro n , 0.1 ppm CPNT .01 micro n , .01 ppm CXNT .01 micro n , .001 ppm

Activated Carbo n Absorber desig n ed to remove vapors a n d odors. I n stalled immediately dow n stream of either a CPNT or a CXNT coalescer, it will red u ce oil carryover to .003 ppm.

STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM S E R I E S D C N F, C S N F, C P N F, C X N F A N D A C N F


Same filtration grade as aluminum filters Identified with an F suffix U stamped for the USA and CRN approved for Canada Housings are freestanding and top loading for easy element replacement All grades of filter element end caps are molded, providing strength, durability and long life

QuincyCompressor.com
4

Ma d e in the U.S.A.

The Science of Compresse d Air

The Science of Compresse d Air

S TA N D A R D L I N E S P E C I F I C AT I O N S & E N G I N E E R I N G D ATA
Complete Filter Assemblies
Filter Model Pipe Size Flow Rate (Grade) NPT scfm Nm3/hr Metric Dimensions B C mm mm

Element Model (Grade)

Number of Elements

A In.

Dimensions B C In. In.

D In.

Weight lb. kg.

A mm

D mm

Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade

10 20 30 60 125 150 200 300 425 500 650 800 1000 1300 1525

4 4 3 8 1 2 3 4 1 1 114 112 2 2 212 3 3 3


1 1

10 20 30 60 125 150 200 300 425 500 650 800 1000 1300 1525

17 33 50 100 208 250 333 500 708 833 1083 1333 1667 2167 2542

Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade

E E E E E E E E E E E E E E E

10 20 30 60 125 150 200 300 425 500 650 800 1000 1300 1525

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3 3 3 312 5 5 5 5 512 512 512 8 8 8 9

112 112 112 114 112 112 112 112 2 2 2 2 34 2 34 2 34 2 12

8 8 8 13 15 15 21 21 22 22 30 32 32 37 42

3 3 3 4 4 4 6 6 6 6 6 8 8 8 12

1.43 1.43 1.43 2.87 5.95 5.95 7.72 7.72 9.70 9.70 11.00 25.40 25.40 34.20 41.90

0.65 0.65 0.65 1.30 2.70 2.70 3.50 3.50 4.40 4.40 5.00 11.50 11.50 15.50 19.00

72 72 72 88 125 125 125 125 135 135 135 200 200 200 230

35 35 35 32 39 39 39 39 50 50 50 68 68 68 65

210 210 210 315 365 365 515 515 545 545 745 805 805 925 1050

75 75 75 100 100 100 150 150 150 150 150 200 200 200 300

Model Grades 1503, 1504 & 2004

A C
Model Grades 200616512

A C B

D
Model Grades 10, 20 & 30 Model Grades 601525

Steel Housings Flanged


Filter Model Pipe Size Flow Rate (Grade) Flg. scfm Nm3/hr

Element Model (Grade)

Number of Elements

A In.

Dimensions B C In. In.

D In.

Weight lb. kg.

A mm

Metric Dimensions B C mm mm

D mm

Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade

1503 3 1504 4 2004 4 2006 6 3004 4 3006 6 4506 6 6008 8 10510 10 16512 12

1500 1500 2000 2000 3000 3000 4500 6000 10500 16500

2550 2550 3400 3400 5100 5100 7650 10200 17850 28050

Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade

1500 1500 2000 2000 3000 3000 1500 1500 1500 1500

1 1 1 1 1 1 3 4 7 11

58 58 58 5914 72 75 14 8312 86 34 100 113 34

15 1718 2138 2512 2138 25.5 2514 25 31 4412

48 48 4814 48 6214 64 6812 68 80 87

10 612 13 712 13 712 2312 23 30 16

165 175 320 360 385 420 580 650 800 1000

74 80 145 163 175 191 263 295 363 454

1472 1473 1473 1505 1829 1911 2121 2203 2540 2889

381 435 543 648 543 648 641 635 787 1130

1219 1219 1226 1219 1581 1626 1740 1727 2032 2210
Max. Working Pressure psig barg

254 165 330 191 330 191 597 584 762 406
Element End Cap Color Code

Max. Particle Max. Particle Size Oil Content Class Removal Filter Element to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns

Specs

Max. Oil Carryover at 68F at 20C ppm mg/m3

Pressure Loss Max. Temperature F C Clean & Dry psi mbar Wet psi mbar Change Element psi mbar

DCNE CSNE CPNE CXNE ACNE

3 2 1 1 1

4 2 1 1 1

5 1 0.01 0.01 0.01

5.0 0.1 0.01 0.001 0.003

5.0 0.1 0.01 0.001 0.003

248 248 248 248 77

120 120 120 120 25

1 1 2 2 1

40 75 100 140 75

1 2 4 5

75 150 300 350

6 400 6 400 6 400 6 400 Min. every 6 months

232 232 232 232 232

16 16 16 16 16

Green Red Blue Black Black

Correction Factor Operating psig Pressure barg Correction Factor 4 0.3 0.21 9 0.6 0.29 15 1 0.38 29 2 0.53 44 3 0.65 58 4 0.76 72 5 0.84 87 6 0.92 100 7 1 115 8 1.07 130 9 1.13 145 10 1.19 160 11 1.25 174 12 1.31 189 13 1.36 203 14 1.41 218 15 1.46 232 16 1.51

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
5

C O M P R E S S E D A I R F I LT E R S
HIGH TEMPERATURE 1 MICRON DUST FILTERS, 450F, 150 PSIG

Nomex outer layer is provided for high-temperature operation Push-to-fit design used on threaded filters for easy filter element replacement Multiwrap element construction provides optimum performance

ALUMINUM HOUSINGS, THREADED NPT CONNECTIONS 15 TO 650 CFM, SERIES HTDT

STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM, SERIES HTDF


Features a high-temperature dust filter with heavy-duty bowl Ribbed bowl facilitates removal when changing elements
NOTE: Alloy filters shipped loose will have a special high-temperature black powder coat paint.

Same filtration grade as aluminum filters Identified with an F suffix U stamped for the USA and CRN approved for Canada Differential pressure indicators are standard Housings are freestanding and top-loading for easy element replacement All grades of filter element end caps are molded, providing strength, durability and long life

QuincyCompressor.com
6

Ma d e in the U.S.A.

The Science of Compresse d Air

The Science of Compresse d Air

HIGH TEMPERATURE SPECIFICATIONS & ENGINEERING DATA


Dust Filters Threaded
Filter Model Pipe Size Flow Rate NPT scfm Nm3/hr Metric Dimensions B C mm mm

Element Model (Grade)

Number of Elements

A In.

Dimensions B C In. In.

D In.

Weight lb. kg.

A mm

D mm

HTDT HTDT HTDT HTDT HTDT HTDT HTDT HTDT

15 30 65 75 150 300 450 650

4 8 1 2 3 4 1 112 2 2
1 3

15 30 65 75 150 300 450 650

25 50 108 125 250 500 750 1084

HTDE 15 HTDE 30 HTDE 65 HTDE 75 HTDE 150 HTDE 300 HTDE 450 HTDE 650

1 1 1 1 1 1 1 1

212 212 412 412 412 534 534 534

2 2 112 112 112 2 2 2


1 1

6 712 12 12 1512 21 21 25

2 2 6 6 6 7 7 7

0.5 0.6 5.7 5.7 7.3 16.5 16.5 22.0

0.25 0.27 2.60 2.60 3.30 7.50 7.50 10.00

63 63 114 114 114 146 146 146

15 15 38 38 38 50 50 50

150 190 305 305 395 435 435 635

50 50 150 150 150 170 170 170

Models HTDF 1503, 1504 and 2004

A C
Models HTDF 200616512

A C B

Models HTDT 15 & 30

Models HTDT 65650

Dust Filters Flanged


Filter Model Pipe Size Flow Rate Flg. scfm Nm3/hr

Element Model (Grade)

Number of Elements

A In.

Dimensions B C In. In.

D In.

Weight lb. kg.

A mm

Metric Dimensions B C mm mm

D mm

HTDF HTDF HTDF HTDF HTDF HTDF HTDF HTDF HTDF HTDF

1503 1504 2004 2006 3004 3006 4506 6008 10510 16512

3 4 4 6 4 6 6 8 10 12

1500 1500 2000 2000 3000 3000 4500 6000 10500 16500

2550 2550 3400 3400 5100 5100 7650 10200 17850 28050

HTDE HTDE HTDE HTDE HTDE HTDE HTDE HTDE HTDE HTDE

1500 1500 2000 2000 3000 3000 1500 1500 1500 1500

1 1 1 1 1 1 3 4 7 11

58 58 58 5914 72 7514 8312 86 34 100 113 34

15 1718 2138 25.5 2138 2512 2514 25 31 4412

48 48 4814 48 6214 64 6812 68 80 87

10 612 13 712 13 712 2312 23 30 16

165 175 320 360 385 420 580 650 800 1000

74 80 145 163 175 191 263 295 363 454

1473 1473 1473 1505 1829 1911 2121 2203 2540 2889

381 435 543 648 543 648 641 635 787 1130

1219 1219 1226 1219 1581 1626 1740 1727 2032 2210

254 165 330 191 330 191 597 584 762 406

Specs
Filter Element

Particle Removal in Microns

Max. Oil Carryover at 68F at 20C ppm mg/m3

Pressure Loss Max. Temperature F C Clean & Dry psi mbar Wet psi mbar Change Element psi mbar

Max. Working Pressure psig barg

Element End Cap Color Code

High-temperature dust filter element grade HTDE 1 2 2 450 250

1.1

75

NA

NA

400

150

10

Brick Red

Correction Factor Operating psig Pressure barg Correction Factor 145 10 0.34 290 20 0.57 435 30 0.71 580 40 0.86 725 50 1.0

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

C O M P R E S S E D A I R F I LT E R S
B R E AT H A B L E A I R S Y S T E M S 15 TO 30 CFM Quincy Breathable Air Packages are complete systems designed to provide, clean, odor-free, taste-free, particle and liquid oil-free compressed air for sand blasting and/or painting hoods. The 15-cfm system has two outlet ports and can accommodate two suits. The 30-cfm package has four outlet ports and can accommodate four suits. The system provides absolute filtration down to 0.01 micron and oil removal down to 0.003 ppm. Special non-shedding, high-speed carbon granules increase vapor-holding capacity.
The System Includes:

Push-to-fit design PNF drain layer Pressure differential indicator Multiwrap construction Air pressure regulator and gauge Activated carbon element impregnated with red dye oil indicator Color-coded end caps Compressed air heater option

Aluminum housings with electrophoretic coating to prevent corrosion WSNT moisture separator CSNT 1 micron, 0.1 ppm Coalescer QUDT with CPNT 0.01 micron, 0.01 ppm and .003 ppm activated carbon absorber Wallmounting or floor-mounting configuration

OVER & UNDER DUPLEX 10 TO 50 CFM, SERIES OUDT Using a unique two-sided head, Quincys Over & Under Duplex filter combines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an ACN Series (.003-ppm) activated carbon absorber. This compact, twostage, single-piece filtration system saves space, is easy to install and delivers ISO 8573.1 class 1 compressed air. The Over & Under is ideal for food and beverage, instrumentation and pharmaceutical applications.
The System includes:

Combination Coalescer and Activated Carbon Absorber Two functions in one unit Space-saving Over & Under configuration Push-to-fit design for easy filter element replacement Multiwrap element construction ensures optimum performance Non-shedding, high-speed carbon granules increase vapor-holding capacity Aluminum housings with electrophoretic coating to prevent corrosion. Standard pressure differential indicator Standard automatic condensate drain

QuincyCompressor.com
8

Ma d e in the U.S.A.

The Science of Compresse d Air

The Science of Compresse d Air

BREATHABLE AIR, OVER & UNDER DUPLEX SPECIFICATIONS & ENGINEERING DATA
Breathable Air Packages
Filter Model Pipe Size NPT Air Outlet Ports Flow Rate scfm Nm3/hr Element Model (Grade) Number of Elements A In. Dimensions B C In. In. D In. Weight lb. kg. A mm Metric Dimensions B C mm mm

D mm

Wallmounted Breathable Air Packages 1 4 2 15 25 BWST 15 1 4 2 15 25 BWHT 15 3 8 2 15 25 BWST 30 3 8 2 15 25 BWHT 30 Frame-Mounted Breathable 1 4 4 BFST 15 1 BFHT 15 4 4 3 8 4 BFST 30 3 8 4 BFHT 30
Models BWST 15 & 30

BAEK BAEK BAEK BAEK BAEK BAEK BAEK BAEK

15 15 30 30 15 15 30 30

1 1 1 1 1 1 1 1

Kit Kit Kit Kit Kit Kit Kit Kit

1014 1534 1014 1534 1934 1934 1934 1934

1234 18 1234 18 NA NA NA NA

1234 1314 1234 1314 1734 1734 1734 1734

3 4 3 4 1934 1934 1934 1934

0.50 0.60 5.70 5.70 2.35 2.35 2.35 2.35

0.25 0.27 2.60 2.60 1.05 1.05 1.05 1.05

280 418 280 418 500 500 500 500

360 498 360 498 NA NA NA NA

323 337 323 337 450 450 450 450

77 100 77 100 500 500 500 500

Air Packages 30 50 30 50 30 50 30 50

Models BFST 15 & 30

Models OUDT 1050

Over & Under Duplex


Filter Model Pipe Size Flow Rate NPT scfm Nm3/hr

Element Model (Grade)

Number of Elements

A In.

Dimensions B C In. In.

D In.

Weight lb. kg.

A mm

Metric Dimensions B C mm mm

D mm

OUDT OUDT OUDT OUDT

10 15 30 50

4 4 3 8 1 2
1 1

10 15 30 50

17 25 50 83

OUDK OUDK OUDK OUDK

10 15 30 50

1 1 1 1

Kit Kit Kit Kit

3 3 3 312

6 6 6 8

7 7 7 9

3 3 3 4

1.90 1.90 1.90 2.75

0.85 0.85 0.85 1.25

72 72 72 90

150 150 150 200

173 173 173 225


Max. Working Pressure psig barg

75 75 75 100
Element End Cap Color Code

Max. Particle Max. Particle Size Oil Content Class Removal Filter Element to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns

Specs

Max. Oil Carryover at 68F at 20C ppm mg/m3

Pressure Loss Max. Temperature F C Clean & Dry psi mbar psi Wet mbar Change Element psi mbar

Breathable Air Package Kit BAEK 1 1 Duplex Filter Kit (OUDK) CPNE 1 1 ACDE 1 1 Correction Factor Operating psig Pressure barg Correction Factor 4 0.3 0.21 9 0.6 0.29 15 1 0.38

>0.01 0.01 0.01

>0.003 0.01 0.003

>0.003 0.01 0.003

77 248 77

25 120 25

3.7 2.2 1.1

250 150 75

6.6 4.4 NA

950 300 NA

Min. every 6 months 145 6 400 232 Min. every 6 months 232

10 16 16

Red/Blue/Black Blue Black

29 2 0.53

44 3 0.65

58 4 0.76

72 5 0.84

87 6 0.92

100 7 1.0

115 8 1.07

130 9 1.13

145 10 1.19

160 11 1.25

174 12 1.31

189 13 1.36

203 14 1.41

218 15 1.46

232 16 1.51

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

WARNING: The Breathable air systems described in this brochure will not remove certain types of gases, including Carbon Monoxide (CO) and Carbon Dioxide (CO2 ). These Breathable Air Systems are designed to offer the user protection in potentially harmful environments. It is therefore imperative the products be

correctly installed and properly controlled by a competent person. Properly controlled means the equipment installed should be fully checked prior to every use. Should any fault be discovered, it must be repaired or the failed component replaced to guarantee full working order before use.

C O M P R E S S E D A I R F I LT E R S
M E C H A N I C A L M O I S T U R E S E PA R AT O R S 20 TO 1500 CFM, 230 PSIG, SERIES WSNT Quincy Mechanical Moisture Separators are designed to remove bulk liquids and large volumes of water. They are typically installed downstream of aftercoolers, air receivers, refrigerated air dryers and at strategic points of use throughout the compressed air distribution system. The design employs an internal spinner to create a centrifugal action that effectively removes large quantities of water.

Large sump and quiet zone to prevent moisture re-entrainment Modular design allows for easy installation of multiple housings and saves energy Annular seal and captive Oring prevent leaks Aluminum housings (14" to 3 NPT) feature electrophoretic coating to prevent corrosion Aluminum housings (14" to 3" NPT) carry a 10-year housing guarantee Standard automatic condensate drain

SPECIFICATIONS & ENGINEERING DATA


Moisture Separators
Filter Model Pipe Size Flow Rate NPT scfm Nm3/hr A In. Metric Dimensions B C In. In. D In. Weight lb. kg. A mm Dimensions B C mm mm D mm

WSNT WSNT WSNT WSNT WSNT WSNT WSNT WSNT WSNT WSNT

20 30 63 127 176 318 427 675 1000 1500

4 8 1 2 3 4 1 114 112 2 212 3


1 3

20 30 63 127 176 318 427 675 1000 1500

35 50 112 216 300 540 725 1150 1700 2550

3 3 312 5 5 5 512 512 8 8

114 114 114 112 112 112 2 2 234 234

814 814 814 12 12 12 19 19 24 24

3 3 4 4 4 4 6 6 8 8

1.45 1.45 2.90 5.95 5.95 5.95 9.70 9.70 25.5 25.5

0.65 0.65 1.30 2.70 2.70 2.70 4.40 4.40 11.5 11.5

72 72 88 125 125 125 135 135 200 200

35 35 32 39 39 39 50 50 68 68

210 210 210 300 300 300 480 480 590 590

75 75 100 100 100 100 150 150 200 200

Specs
Filter Model

Max. Recommended Operating Temp. F C

Min. Typical Recommended Pressure Loss Operating Temp. At Rated Flow F C psi mbar

Max. Working Pressure psig barg

WSNT

248

120

35

1.5

0.7

50

232

16

Correction Factor Operating psig Pressure barg Correction Factor Operating psig Pressure barg Correction Factor 4 0.3 0.21 115 8 1.07 9 0.6 0.29 130 9 1.13 15 1 0.38 145 10 1.19 29 2 0.53 160 11 1.25 44 3 0.65 174 12 1.31 58 4 0.76 189 13 1.36 72 5 0.84 203 14 1.41 87 6 0.92 218 15 1.46 100 7 1 232 16 1.51

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

QuincyCompressor.com
10

Ma d e in the U.S.A.

The Science of Compresse d Air

The Science of Compresse d Air

QUINCY SYSTEM PRESSURE TRANSMITTERS Quincy System Pressure Transmitters sense pressure, differential pressure or both at specific points throughout a compressed air system. Accurate to half of 1%, a 4 to 20 mA signal continuously transmits readings to the systems main control station. Continuous and accurate pressure tracking facilitates periodic compressed air audits and enables the automation and/or operator to monitor the system and adjust controls for optimum efficiency.

Reduce energy and filtration costs Improve air treatment efficiency Monitor critical applications 24/7 operation Simple and cost-effective installation Guaranteed for 5 years Rugged NEMA 4/IP65 rating

ACCESSORIES Quincy filtration products come standard with mechanical condensate drains and are available with

Optional electronic timer drains Optional pneumatic no-loss drains Optional electronic no-loss drains

Quincy Filters are equipped standard with top-mounted pressure indicators.

Pop-up for 10 cfm through 30 cfm ( 12" NPT & 3/8" NPT) Gauge for 50 cfm through 16,500 cfm ( 12" NPT through 12" FLG)

Multiple filters can be ganged together using the available two- and three-unit connecting kits.

Eliminates leaks, saving energy Easy and space-saving installation

Aluminum Alloy filters can be wallmounted using the available wallmounting brackets.

Provides easy and flexible installation


11

COMPRESSED AIR SYSTEMS BEST PRACTICE


The Science of Compresse d Air
QGV-100 quincycompressor.com

Air Quality Classification ISO 8573.1


QPNC-500 quincycompressor.com

Moisture Solids Micron ISO PDP ISO 0.01 1 +38F 4

Oil PPM ISO 0.01 1

Wet System Avg. P


psi 10.7 Mbar 738

0.01

+38F

0.003

11.8

814

Quincy Rotary Screw

WSN Wet Bulk Receiver Liquid 1gal/CFM DP1 DP2

CSN 1 Micron 0.1 PPM DP3

Refrigerated Air Dryer CPN QPNC Non-Cycling 0.01 Micron QPCD Cycling 0.01 PPM DP4 DP5

Dry Receiver 5gal/CFM

ACN 0.003 PPM Vapor & Odors

0.01
QDHT-1000
quincycompressor.com

1 -100F 1 0.001 1 14.2 NOTE: Requires CXN (.001 PPM) filter in series with standard CPN prefilter. 2 -40F 2 0.01 1 9.2

979

634

quincycompressor.com

0.01

-40F

0.003

10.3

710

Quincy Reciprocating

AC

WSN Moisture Separator DCN Particulate/Coarse Coalescer CSN STD 0.1 PPM Coalescer, 1 Micron CPN CXN ACN OUD HTD QPNC QPCD QDTS QDTH QDHP QDBP QPHT Polishing 0.01 PPM Coalescer Xtra 0.001 PPM Coalescer Activated Carbon Absorber Over + Under Duplex High Temperature, 1 Micron Non-Cycling Refrigerated Dryer Cycling Refrigerated Dryer Small Heatless Dryer Industrial Heatless Dryer Heated Purge Dryer Blower Purge Dryer High Temp. Refrigerated Dryer

WSN Bulk Liquid DP6

Dry CPN Desiccant Heatless Air Dryer CSN 1 Micron Receiver 0.01 Micron QDTSSmall Particulate 5gal/CFM 0.01 PPM QDTHIndustrial DP7 -40F PDP

ACN 0.003 PPM Vapor & Odors

QDHP-1000
quincycompressor.com

-40F

0.01

9.2

634

0.01

-40F

0.003

10.3

710

WOS Water/Oil Separator AC After Cooler DP Drain Point

Dry Desiccant Heated Air Dryer CSN (NPT) CPN HTD (FLG) Receiver 0.01 Micron QDHPHeated Purge 1 Micron 5gal/CFM 0.01 PPM QDBPBlower Purge Particulate DP8 -40F PDP

ACN 0.003 PPM Vapor & Odors ACN 0.003 Micron 1 2 +50F 6 0.01 2 7.8 538

QPHT-40

quincycompressor.com

WOS Water/Oil Separator OUD DCN 5 Micron 5 PPM DP9 High Temperature/ Refrigerated Air Dryer QPHTHigh Temp. DP10 CSN 1 Micron 0.1 PPM DP11

0.01

+50F

0.003

10.0

689

Approximate Liquid Removal


100 CFM, 100 psi, 80F, 4000 hrs./yr., 2 PPM Drain Gallons Drain Gallons Drain Gallons CPN Point per Year Point per Year Point per Year 0.01 Micron 1 3000 5 140 9 300 0.01 PPM 2 3 4 2000 305 1300 6 7 8 3000 310 310 10 11 4320 120

2005 Quincy Compressor an EnPro Industries company All rights reserved. Litho in U.S.A. (QATF-001 03/05)

701 North Dobson Avenue | Bay Minette, AL 36507 | Phone 251.937.5900 | Fax 251.937.7182 | Nearest Distributor: 888.424.7729 | Email: info@quincycompressor.com