RE 29 731/12.87
Replaces: 2.87
It consists basically of: overload cut-out LED directional indicator 2 electronic switched outputs
F 87168
VT 11 003-1X
Control curve
Technical data
Uoff
Solenoid "B" Solenoid "A"
Supply voltage UB eff: 10,5 V to 35 V three phase bridge (per winding) U : 10,5 V to 35 V U : 10 V to 24 V full bridge (per winding) Note: For both full wave and three phase rectification, a smoothing capacitor of 2200 F is required for each individual module. Max. output current (per switched output) Overload current cut-off Output voltage
UEB
~ 1,8 V
~ 1,8 V
UEA
Input resistance
m : ~ 0,16 kg
If a number of adjacent modules are on 100 % duty, or if both switched output amplifiers are in use simultaneously, and at ambient temperatures greater than 40 C, a minimum space 20 mm must be maintained between modules!
1/4
2/4
Overload cut-out Switched output
RE 29 731/12.87
U I
5 Solenoid "A" Imax ~ 1,2 A Overload cut-out Switched output
U I
4 Solenoid "B" Imax ~ 1,2 A
Overload detection
DC DC
0V
+ UM M0 UM
Note:
If a voltage (UEA or UEB) greater than zero volts is present at inputs A or B, before supply voltage is present, the over current cut out may trip out. Reset the over current cut out by returning UEA and UEB to zero.
RE 29 731/12.87
Ordering Code
VT 11 003 1X
Amplifier module for switching valves Series 10 to 19 = 1X (10 to 19: installation and connection dimensions remain unchanged)
*
Further details in clear text
Terminal Wiring
Supply voltage
+ UB 0V Input "A"
1 2 3
4 5 6
Description of Function
The electronic amplifier module is used to control switching valves. The amplifier clips into the standard type of mounting plate found in electrical cabinets. Electrical connections are by means of a terminal strip. The amplifier module contains the necessary electronics for simultaneous or individual control of the two switched outputs; however, on simultaneous operation of both inputs (A and B) it is only possible to double the output current of one switched output (A or B).
Important Note
Warning: No protection against reverse polarity! Wrong connection of supply voltage will lead to destruction of amplifier module.
Unit Dimensions
Mounting plate NS 35/7,5 to DIN 50 022 4 5 6
(in mm)
79
1 2 3 85,5 25
3/4
RE 29 731/12.87
Notes
Mannesmann Rexroth GmbH D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-10 40 Telex 6 89 418
G.L.Rexroth Ltd., Cromwell Road, St. Neots, Cambridgeshire, PE19 2ES. Tel: 0480 476041 Fax: 0480 219052 All rights reserved Subject to revision