Documente Academic
Documente Profesional
Documente Cultură
Selection table
SIMATIC PXI200
Design, Operating distance 0 ... 0.8 mm (PXI.1.) 1 ... 4 mm (PXI.2.) Output NO contact/NC contact pnp/npn Number of wires Operating voltage 10/15 ... 30/35 V DC Connection M8 connector M12 connector Cable Degree of protection IP65 / IP67 See page
3 mm
4 mm
M5
5 mm x 5 mm
M8
6.5 mm
8 mm x 8 mm
M12
12 mm x 40 mm
12 mm x 32 mm
0.6 mm
0.8 mm
0.8 mm
/ /
3
/ /
3
/ /
3
/ /
3
/ /
2, 3, 4
/ /
3
/ /
3
/ /
2, 3, 4
/ /
3, 4
/ /
4
/
2/141
/
2/146
/
from 2/148
/
2/150
/
2/140
/
2/141
/
2/141
/
2/150
A configurator for fast product selection and ordering in the Internet can be found at www.siemens.com/simatic-sensors/px
2/138
Siemens FS 10 2009
Siemens AG 2008
2
SIMATIC PXI200
Design, Operating distance 1 ... 4 mm (PXI.2.) 5 ... 10 mm (PXI.3.) 12 ... 22 mm (PXI.4.) 25 ... 40 mm (PXI.5.) Output NO contact/NC contact pnp/npn Number of wires Operating voltage 10/15 ... 30/35 V DC Connection M12 connector Cable Terminal compartment Degree of protection IP65 / IP67 See page
M18
Button 18 mm
M30
40 mm x 40 mm
60 mm x 80 mm
80 mm x 100 mm
2.5 mm 5 mm 5 mm 8 mm 5 mm 10 mm 15 mm 15 mm 20 mm 30 mm 40 mm
/ /
2, 3, 4
/ /
2, 3, 4
/ /
3
/ /
2, 3, 4
/ /
2, 3, 4
/ /
4
/ /
4
/
2/153
/
from 2/157
/
2/158
/
from 2/162
/
from 2/165
/
2/169
/
2/169
A configurator for fast product selection and ordering in the Internet can be found at www.siemens.com/simatic-sensors/px
Siemens FS 10 2009
2/139
Siemens AG 2008
Technical specifications
Class
Number of wires
Design Installation in metal Rated operating distance sn Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
Standard duty 3-wire 3 mm, mini Flush 0.6 mm Stainless steel 10 ... 30 10 100 5000 0.01 10 Yellow LED IP67
Dimensions
Mounting instructions
Dimension depending on form A = active surface B = metal-free area
A 4,5 6 B 1,5 A B
3RG46 032AB00
3
22
2/140
Siemens FS 10 2009
NSD00298
LED
16
NSD00302
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire 5 mm 5 mm, mini Flush 0.8 mm Brass, nickel-plated 10 ... 30 10 200 5000 0.01 10 Yellow LED IP67 Standard duty 3-wire 4 mm, mini Flush 0.8 mm Stainless steel 10 ... 30 10 200 5000 0.01 8 Yellow LED IP67 Standard duty 3-wire M5, mini Flush 0.8 mm Stainless steel 10 ... 30 10 200 5000 0.01 10 Yellow LED IP67
3 0.14 mm2 3RG42 100AG00 3RG42 100AF00 3RG46 100GB00 3RG42 107AG00 3RG42 107AF00 3RG46 107GB00
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock
Dimensions
Mounting instructions
Dimension depending on form A = active surface B = metal-free area
A 3,3 5 B 2,4
A 6 8 B 2,4
3,3 A
B 2,4
NSD00304
3RG42 360AG00
5,5 5x5 1,5
3RG42 00 1AB00
4 18
3RG42 00 7AB00
F S 1 0 _ 0 0 3 5 2
NSD0_00306a
NSD0_0311a
1 8
2 3
25 3
14
25
25
3 8
18 20
LED
NSD00310
6 ,5
NSD00308
3 8
S W 6 ,5 8 x 1
NSD00307
M 1,6
SW 7 LED
M
8 x 1
Siemens FS 10 2009
2/141
1 8
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M8 Flush 1 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67 Standard duty 4-wire M8 Flush 1 mm Stainless steel 10 ... 30 1 50 1500 0.1 40 Yellow LED IP67
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
4 A
50
12
B 3
M 8x1 34 SW 13 4
M 8x1
52
NSD00314b
55
LED
NSD00319
LED
NSD00313
LED Sg
M 12x1
2/142
Siemens FS 10 2009
SW 13
34
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty (PLC) 2-wire M8 Flush 1 mm Stainless steel 15 ... 34 1.5 25 1500 0.1 40 Yellow LED IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
4 A
50
12
B 3
3RG40 11 0JB00
M 8x1 34 SW 13
3RG40 11 7JB00
M 8x1 34 SW 13 4
3RG40 113JB00
M 8x1
NSD00314b
55
NSD00319
52
LED
LED
NSD00313
LED Sg
M 12x1
SW 13
34
Siemens FS 10 2009
2/143
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire 6.5 mm, mini Flush 1.5 mm Stainless steel 10 ... 30 10 200 3000 0.02 10 Yellow LED IP67 Standard duty 3-wire 6.5 mm, Shorty Flush 1.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67 Standard duty 3-wire 6.5 mm Flush 1.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.14 mm2 3RG42 011AB00 3RG42 017AG00 3RG42 017AF00 3RG46 017GB00
3 0.25 mm2 3RG40 500AG33 B 3RG40 500AF33 3RG40 500GB33 3RG40 500GA33 3RG40 507AG33 B 3RG40 507AF33 3RG40 507GB33 B 3RG40 507GA33
3 0.25 mm2 3RG40 500AG05 3RG40 500AF05 3RG40 500GB05 3RG40 500GA05 3RG40 507AG05 3RG40 507AF05 3RG40 507GB05 3RG40 507GA05
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock B: Subject to export regulations AL = N and ECCN = EAR99
2/144
Siemens FS 10 2009
Siemens AG 2008
Dimensions
Mounting instructions
3RG42 01, 3RG46 01-7
4 A 13 B 4,5
3RG42 01 1AB00
6,5 16
3RG42 017..00 3RG40 500..33 3RG40 507..33 3RG40 500..05 3RG40 507..05 6,5 6,5 6,5 6,5 3RG46 017..00
6,5
35
33
20
34
29
45
50
34 LED
NSD00336
NSD00328
LED
NSD00329
NSD00326
NSD00332
LED (4x) Sg
LED
LED
NSD00327
LED (4x) Sg
NSD00335
52
2
M 8x1
3RG40 50
4 A 12 B 3 A B
NSD00319
Siemens FS 10 2009
2/145
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M8, mini Flush 1.5 mm Brass, nickel-plated 10 ... 30 10 200 3000 0.01 10 Yellow LED IP67 Standard duty 3-wire 8 mm, Shorty Flush 1.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67 Standard duty 3-wire 8 mm 8 mm Flush 1.5 mm Brass, nickel-plated 10 ... 30 10 200 1000 0.07 10 Yellow LED IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
1) See page 2/242. } Preferred type, available from stock. 2) See from page 2/268. B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
3RG42 11, 3RG46 11, 3RG40 51
4 A 12 B 3
5
3RG42 117..31 3RG40 510..33 3RG40 517..33 3RG42 370..00, 3RG46 370..00 8 8 3 8x8 3RG46 117..31
SW 13
SW 13
35
45
33
16
40 37
29 17
NSD00351
NSD00319
LED
NSD00352
LED (4x) Sg
NSD00333a
NSD00338
LED
NSD00339b
LED Sg
M3 LED
50 37
20
10
M 8x1
NSD00337
59
LED
Sg
NSD00334a
2/146
Siemens FS 10 2009
20
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire M8, Shorty Flush 1.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67 Standard duty 3-wire M8 Flush 1.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1500 0.1 40 Yellow LED IP67 Standard duty 4-wire M8 Flush 1.5 mm Stainless steel 10 ... 30 1.0 50 1500 0.1 40 Yellow LED IP67
3 0.25 mm2 } 3RG40 110AG33 } B 3RG40 110AF33 3RG40 110GB33 3RG40 110GA33
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
4 A 12 B 3
3RG40 110..33 3RG40 117..33 3RG40 110..05 3RG40 117..05 3RG40 113..05
M 8x1 SW 13
M 8x1 SW 13
M 8x1 34 SW 13 4
M 8x1 34 SW 13
M 8x1
45 33
35
50
52
NSD0_00340a
NSD00319
LED
NSD0_00341c
LED (4x) Sg
NSD00314b
55
LED
LED
NSD00313
LED Sg
M 12x1
SW 13
34
Siemens FS 10 2009
2/147
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M12, Shorty Flush 2 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67 3RG40 12.A.33 3RG40 12.G.33 4-wire M12, Shorty Flush 2 mm Brass, nickel-plated 15 ... 34 1.0 50 800 0.1 3 Yellow LED IP67 3RG40 120CD10 3RG40 123CD11 3-wire M12 Flush 2 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67 3RG40 12.A.01 3RG40 12.G.00 4-wire M12 Flush 2 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67 3RG40 120CD00 3RG40 123CD00
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Type
V mA mA Hz mm ms
2 3 4 5 1
E, F F E, F F F
Dimensions
Mounting instructions
6 A 12 B 5
3RG40 120..33
M 12x1 4
3RG40 120CD10
M 12x1 4
35
40
SW 17
SW 17
4 59
NSD00361b
NSD00366
NSD00363
NSD00373
LED
3RG40 123..33
M 12x1
3RG40 123CD11
M 12x1
NSD00360a
SW 17
LED
LED
NSD00367b
SW 17 LED (4x) Sg
NSD00374
50
SW 17 LED Sg
2/148
Siemens FS 10 2009
29,5
B
45 34
SW 17
LED (4x) Sg
50
48
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Standard duty (PLC) 2-wire M12 Flush 2 mm Brass, nickel-plated V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 700 0.1 40 Yellow LED IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
6 A 12 B 5
3RG40 120JB00
M 12x1 4
3RG40 123JB00
M 12x1
4 59
NSD00363
SW 17
A
NSD00360a
NSD00361b
LED
SW 17
LED (4x) Sg
50
48
Siemens FS 10 2009
2/149
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire Cubic 12 mm 40 mm Flush 2 mm Molded plastic 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.2 40 Yellow LED IP67 Standard duty 4-wire Cubic 12 mm 40 mm Flush 2 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 50 1200 0.1 40 Yellow LED IP67 Standard duty 4-wire Cubic 12 mm 32 mm Flush 2 mm Molded plastic 15 ... 34 1.0 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.25 mm2 }
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock
Dimensions
Mounting instructions
B A 6
LED 3,2x5
3RG40 700..45
26 18 6 4 Sensor center 12 10 M3 32 40
3RG40 710CD00
27 12,6 8 2,4 13
16
NSD00378
3,2
32
2,6
NSD00376b
NSD00382
3RG40 707..45
LED 3,2x5 26 18 6 Sensor center 4 M3 32 40 12 10 16
A = active surface B = metal-free area These proximity switches can be mounted next to one another.
3,2
NSD0 00377b
2/150
Siemens FS 10 2009
4
M 8x 1
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire Cubic 12 mm 40 mm Flush 2 mm Molded plastic 15 ... 34 17 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67 Standard duty 4-wire Cubic 12 mm 40 mm Flush 2 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67
3RG40 707CD02
2 3 1
E, F F F
3RG40 703CD00
Dimensions
Mounting instructions
B A 6 5
4
40 32
12
17
26
3,2
NSD00378
36
6,5 LED
6,5
17
26
3,2
Sg
LED
Sg
NSD00380
LED
6,5
34 26
17
3,2
NSD00381
Siemens FS 10 2009
2/151
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire 6.5 mm Not flush 2.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 900 0.08 40 Yellow LED IP67 Standard duty 3-wire M8 Not flush 2.5 mm Stainless steel 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 1200 0.1 40 Yellow LED IP67
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.25 mm2 3RG40 600AG33 B 3RG40 600AF33 B 3RG40 600GB33 B 3RG40 600GA33 3RG40 607AG33 B 3RG40 607AF33 3RG40 607GB33 B 3RG40 607GA33
3 0.25 mm2 3RG40 210AG33 B 3RG40 210AF33 3RG40 210GB33 3RG40 210GA33 3RG40 217AG33 B 3RG40 217AF33 3RG40 217GB33 B 3RG40 217GA33
1) See page 2/242. 2) See from page 2/268. B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
10 20 B 8
3RG40 600..33
6,5
3RG40 607..33
6,5
3RG40 210..33
M 8x1 SW 13
3RG40 217..33
M 8x1
45
33
6
NSD00391
NSD00386
NSD00388
LED
LED
NSD00389a
LED (4x) Sg
NSD00387
2/152
Siemens FS 10 2009
4 SW 13
LED (4x)
Sg
35 4
35 4
45 33
A 6
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire M14 Flush 2.5 mm Molded plastic 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.1 40 Yellow LED IP67 Standard duty 4-wire M14 Flush 2.5 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.1 40 Yellow LED IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
B A 7 6
23
3RG40 720..00
M 14x1
3RG40 723..00
M 14x1
Plan view:
NSD00400
20
23
20
NSD00402a
6x3,5 3,5
56
27
20 5,5
NSD00398a
NSD00399a
5,5 LED
LED
Sg
66
6x3,5 3,5
20
56
12
Siemens FS 10 2009
2/153
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty (PLC) 2-wire M14 Flush 2.5 mm Molded plastic V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 800 0.1 40 Yellow LED IP67
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
1) See page 2/242. 2) See from page 2/268. B: Subject to export regulations AL = N and ECCN = EAR99
Dimensions
Mounting instructions
B A 7 6
23
3RG40 720..00
M 14x1
20
20 5,5
NSD00398a
NSD00402a
6x3,5 3,5
LED
2/154
Siemens FS 10 2009
56
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Type V mA mA Hz mm ms Standard duty 3-wire M12, Shorty Not flush 4 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.2 40 Yellow LED IP67 3RG40 22.A.33 3RG40 22.G.33 4-wire M12, Shorty Not flush 4 mm Brass, nickel-plated 15 ... 34 1.0 50 800 0.2 40 Yellow LED IP67 3RG40 220CD10 3RG40 223CD11 3-wire M12 Not flush 4 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.2 40 Yellow LED IP67 3RG40 22.A.01 3RG40 22.G.00 4-wire M12 Not flush 4 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.2 40 Yellow LED IP67 3RG40 220CD00 3RG40 223CD00
2 3 4 5 1
E, F F E, F F F
Dimensions
Mounting instructions
15 A 9 27 B
6,5
3RG40 220..33
M 12x1
3RG40 220CD10
M 12x1 6,5
35
40
4 65
NSD0_00421a
SW 17
SW 17
56
NSD0_00427a
NSD0_00444a
NSD00423
NSD0_00420a
LED
LED
SW 17
3RG40 223..33
B
M 12x1 4 SW 17 34
3RG40 223CD11
M 12x1
LED
LED (4x) Sg
50 6,5
NSD00428
LED (4x) Sg
NSD0_00448c
LED (4x) Sg
SW 17 39
45 6,5
SW 17
Siemens FS 10 2009
54
2/155
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire Cubic 12 mm 40 mm Not flush 4 mm Molded plastic 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.2 40 Yellow LED IP67 Standard duty (PLC) 2-wire M12 Not flush 4 mm Brass, nickel-plated 15 ... 34 1.5 (24 V) 25 2 300 0.2 40 Yellow LED IP67
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
Dimensions
Mounting instructions
3RG40 80-.AG45
15 A 9 27 B 8
3RG40 800AG45
LED 3,2x5 26 18 6 4 Sensor center 12 10 M3 32 40
3RG40 220JB00
M 12x1 6,5
16
NSD01073
NSD00376b
NSD0_00420a
3RG40 807AG45
B
LED
LED 3,2x5
26 18 6
Sensor center 4 M3 32 40 12 10
3RG40 223JB00
M 12x1 6,5
3RG40 22-.JB00
15 A 9 27 B
3,2
16
4 65
NSD0_00421a
SW 17 LED (4x) Sg SW 17 54
3,2
NSD0 00377b
NSD00423
2/156
Siemens FS 10 2009
56
M 8x 1
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection IP67 IP67 IP67 V mA mA Hz mm ms Standard duty 3-wire M18, Shorty Flush 5 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.15 40 Yellow LED Standard duty 3-wire M18 Flush 5 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.15 40 Yellow LED Standard duty 4-wire M18 Flush 5 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 800 0.15 40 Yellow LED
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
11 A 30 B
10
3RG40 130..33 3RG40 133..33 3RG40 130..00 3RG40 133..00 3RG40 130..01 3RG40 133..01 M 18x1 M 18x1
4
45 31 4
M 18x1
SW 24 34
M 18x1 4
35
SW 24
NSD0_00456b
NSD00446b
NSD00447
LED
M 12x1
SW 24
NSD00445
LED
M 12x1
NSD00451
69 55
LED (4x)
54
Siemens FS 10 2009
2/157
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire 18 mm (button) Flush 5 mm (3,2 mm) Molded plastic 10 ... 30 1.5 50 100 0.15 1.0 IP67 Standard duty 4-wire M14 Not flush 5 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.1 40 Yellow LED IP67
Enclosure material Operational voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
Dimensions
Mounting instructions
3RG40 82
20 A 12 40 B
23
3RG40 75
18 15,95 9,9 3,85
3RG40 820..00
M 14x1
3RG40 823..00
M 14x1
Plan view:
NSD00400
20
15
23
20
NSD00464
NSD00475a
5,5
NSD00398a
NSD00399a
5,5 LED
Mounting instructions
15 30 B 10
LED
Sg
3RG40 750GJ00 also possible with non-embedding mounting: Rated operating distance sn = 3,2 mm
2/158
Siemens FS 10 2009
NSD 00467
66
6x3,5 3,5
56
27
12
20
6x3,5 3,5
20
56
12
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operational voltage (DC) DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Standard duty (PLC) 2-wire M18 Flush 5 mm Brass, nickel-plated V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 400 0.15 40 Yellow LED IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
11 A 30 B
M 18x1
M 18x1 4
NSD00451
3RG40 130JB00
3RG40 133JB00
10
54
SW 24
NSD00446b
NSD00445
LED
M 12x1
69 55
Siemens FS 10 2009
2/159
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M18, Shorty Not flush 8 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 500 0.2 40 Yellow LED IP67 Standard duty 3-wire M18 Not flush 8 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 500 0.2 40 Yellow LED IP67 Standard duty 4-wire M18 Not flush 8 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 500 0.2 40 Yellow LED IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.25 mm2 B 3RG40 230AG33 B 3RG40 230AF33 B 3RG40 230GB33 B 3RG40 230GA33
3 0.25 mm2 } B 3RG40 230AG01 B 3RG40 230AF01 B 3RG40 230GB00 B 3RG40 230GA00
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
20 A 11 28 B
15
3RG40 230..33
M 18x1 4
3RG40 233..33
M 18x1
45 31 10,5
35 10,5
SW 24 34
15
54 10,5
69 55 10,5
NSD00500
NSD0_00502a
NSD0_00503b
LED
M 12x1
NSD00493
SW 24
LED (4x)
LED
NSD00494b
M 12x1
2/160
Siemens FS 10 2009
SW 24
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Type Standard duty (PLC) 2-wire M18 Not flush 8 mm Brass, nickel-plated V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 200 0.2 40 Yellow LED IP67 3RG40 23.JB00
Dimensions
Mounting instructions
20 A 11 28 B 15
15
54 10,5
69 55 10,5
NSD00500
NSD00493
LED
NSD00494b
M 12x1
SW 24
Siemens FS 10 2009
2/161
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M30, Shorty Flush 10 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.3 40 Yellow LED IP67 Standard duty 3-wire M30 Flush 10 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.3 40 Yellow LED IP67 Standard duty 4-wire M30 Flush 10 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.3 40 Yellow LED IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.25 mm2 B 3RG40 140AG33 B 3RG40 140AF33 B 3RG40 140GB33 B 3RG40 140GA33
3 0.25 mm2 } B 3RG40 140AG01 } B 3RG40 140AF01 } B 3RG40 140GB00 B 3RG40 140GA00
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
3RG40 14...33
25 37 B 16
3RG40 14 0..33
M 30x1,5 5
3RG40 143..33 3RG40 140..00 3RG40 143..00 3RG40 140..01 3RG40 143..01 M 30x1,5
M 30x1,5
M 30x1,5
45 31
35
NSD00521
SW 36
NSD0_00523b
NSD0_00524b
SW 36
LED (4x)
M 12x1
NSD00518a
NSD00519
LED (4x) Sg
LED
LED
2/162
Siemens FS 10 2009
SW 36 58,5
69 55
54
SW 36 34
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Standard duty (PLC) 2-wire M30 Flush 10 mm Brass, nickel-plated V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 300 0.3 40 Yellow LED IP67 Standard duty 4-wire M30 Flush 10 mm Brass, nickel-plated 15 ... 34 15 200 300 0.3 40 IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
25 37 B 16
3RG40 140JB00
M 30x1,5 5
3RG40 143JB00
M 30x1,5 5
3RG40 143CD00
M 30x1,5 5
3RG40 140CD00
M 30x1,5 5
SW 36 58,5
SW 36
NSD00521
SW 36
NSD00519
NSD00518a
LED (4x) Sg
NSD00518a
NSD00519
LED (4x) Sg
LED
LED
SW 36 58,5
69 55
54
69 55
54
Siemens FS 10 2009
2/163
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty 3-wire M30, Shorty Not flush 15 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.4 40 Yellow LED IP67 Standard duty 3-wire M30 Not flush 15 mm Brass, nickel-plated 15 ... 34 17 (24 V); 30 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.4 40 Yellow LED IP67 Standard duty 4-wire M30 Not flush 15 mm Brass, nickel-plated 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 300 0.4 40 Yellow LED IP67
Enclosure material Operating voltage (DC) No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
V mA mA Hz mm ms
3 0.25 mm2 B 3RG40 240AG33 B 3RG40 240AF33 B 3RG40 240GB33 B 3RG40 240GA33
3 0.25 mm2 } B 3RG40 240AG01 B 3RG40 240AF01 B 3RG40 240GB00 B 3RG40 240GA00
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
30 A 15 80 B 25
3RG40 24 0..33
M 30x1,5 SW 36 16
3RG40 243..33
M 30x1,5 31 16 5
16
15
35
45
35
5
LED (4x) M 12x1
69
NSD00548
NSD0_00551a
NSD0_00552b
LED
M 12x1
NSD0_00544b
SW 36
SW 36 LED (4x)
NSD00545b
LED
2/164
Siemens FS 10 2009
SW 36
58,5
54
55
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv LEDs Switching status Supply voltage Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire Cubic 40 mm 40 mm Flush 15 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 100 0.75 100 Yellow LED Green LED IP65 Standard duty 4-wire Cubic 40 mm 40 mm Flush 15 mm Molded plastic 15 ... 34 30 (24 V); 50 (34 V) 200 ( 50 C); 150 ( 85 C) 100 0.75 100 Yellow LED Green LED IP65 Standard duty 4-wire Cubic 40 mm 40 mm Flush 15 mm Molded plastic 15 ... 34 30 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 50 0.75 100 Yellow LED Green LED IP67
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
25 A 75 B 30
3RG40 316..0.
4 0
4 0 4 5
3RG40 383..00
4 0
LED 40 46 55
NSD 01163
5 ,3
NSD 01164
1 2 0
L E D Y E L E D G N 7 ,3 5 ,3 3 0 1 4
6 0
N S D 0 _ 0 0 5 6 4 a
M 2 0 1 ,5
30 40
5,3x7,3
M 12x1 40
69
Siemens FS 10 2009
2/165
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty (PLC) 2-wire M30 Not flush 15 mm Brass, nickel-plated V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 180 0.4 40 Yellow LED IP67 Standard duty (PLC) 2-wire Cubic 40 mm 40 mm Flush 15 mm Molded plastic 15 ... 34 1.5 25 2 100 0.75 100 Yellow LED IP65
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv Switching status display Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
2 0.25 mm2 } B 3RG40 240JB00 B 3RG40 243JB00 } 0.5 ... 2.5 mm2 3RG40 316JB00
1) See page 2/242. 2) See from page 2/268. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
3RG40 240..00 3RG40 243..00
30 A 15 80 B
16 16
3RG40 240..00
M 30x1,5
3RG40 243..00
M 30x1,5
75
B 30
45
40
40
40
25
54
15
69
120
55
5,3
60
SW 36
NSD00548
SW 36
NSD0_00544b
LED
NSD00545b
LED (4x)
30
B
M 201,5
M 12x1
2/166
Siemens FS 10 2009
NSD0_00560a
NSD 01164
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage No-load supply current I0 Rated operational current Ie Switching frequency f Repeat accuracy R Power-up delay tv LEDs Switching status Supply voltage Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection V mA mA Hz mm ms Standard duty 3-wire Cubic 40 mm 40 mm Not flush 20 mm Molded plastic 15 ... 34 25 (24 V); 40 (34 V) 200 ( 50 C); 150 ( 85 C) 75 0.75 100 Yellow LED Green LED IP65 Standard duty 4-wire Cubic 40 mm 40 mm Not flush 20 mm Molded plastic 15 ... 34 30 (24 V); 50 (34 V) 200 ( 50 C); 150 ( 85 C) 75 0.75 100 Yellow LED Green LED IP65
1) See page 2/242. } Preferred type, available from stock. B: Subject to export regulations AL = N and ECCN = EAR99.
Dimensions
Mounting instructions
70 A 50 100 B 40
4 5
3RG40 416..0.
4 0
4 0
4 0
40
5 ,3
1 2 0
L E D Y E L E D G N 7 ,3 5 ,3 3 0 1 4
NSD00583
6 0
M 2 0 1 ,5
N S D 0 _ 0 0 5 6 4 a
Siemens FS 10 2009
2/167
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Standard duty (PLC) 2-wire Cubic 40 mm 40 mm Not flush 20 mm Molded plastic V mA mA mA Hz mm ms 15 ... 34 1.5 25 2 75 0.75 100 Yellow LED IP65
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Minimum load current Switching frequency f Repeat accuracy R Power-up delay tv LEDs Switching status Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection
Dimensions
Mounting instructions
70 A 50 100 B 40
45
3RG40 416JB00
40
40
40
40
120
5,3
60
NSD00583
30
M 201,5
2/168
Siemens FS 10 2009
NSD0_00560a
Siemens AG 2008
Technical specifications
Class Number of wires Design Installation in metal Rated operating distance sn
Enclosure material Operating voltage DC No-load supply current I0 At 24 V DC Rated operational current Ie Continuous Switching frequency f Repeat accuracy R Power-up delay tv LEDs Switching status Supply voltage Precautions Spurious signal suppression Short-circuit-proof/overload-proof Reverse-polarity protection Wire-break protection Inductive interference protection Radio interference protection Degree of protection Standard duty 4-wire Cubic 60 mm 80 mm Not flush 30 mm Molded plastic V mA mA Hz mm ms 15 ... 34 30 (24 V); 50 (34 V) 200 ( 50 C); 150 ( 85 C) 50 1.0 100 Yellow LED Green LED IP65 Standard duty 4-wire Cubic 80 mm 100 mm Not flush 40 mm Molded plastic 15 ... 34 30 (24 V); 50 (34 V) 200 ( 50 C); 150 ( 85 C) 10 1.0 200 Yellow LED Green LED IP65
Dimensions
Mounting instructions
3RG40 426CD00
90 A 60 210 B 90
3RG40 426CD00
6 0 4 5 L E D Y E L E D G N M 2 0 x 1 ,5
3RG40 436CD00
80,3 65 27,5 LED YE LED GN Pg 13,5
NSD00625
40
7 7
2 4 ,5
NSD00608
5 ,3 4 1
N S D 0
100 65
0 0 6 0 1 a
4 5
5,3 41,5
3RG40 436CD00
80 A 15 160 B 90
NSD00613
40
Siemens FS 10 2009
2/169