Residential Gas
Multi-Fuel LP Vapor/Natural Gas
Standard Features
D DC-RET Digital Control D Designed for Easy Installation
d Designed for today’s most sophisticated electronics d Polymer base eliminates the need for a concrete
d Digital voltage regulation protects your sensitive mounting pad, reducing installation time and cost
electronics from harmonic distortion and unstable power d Fuel and electrical connections through the enclosure
quality wall eliminate the need for stub-ups through the bottom
d LED display shows system status d Field-connection terminal block simplifies electrical
connections
D Engine Features d Hinged roof with lockable latches
d Kohler Command PROr OHV engine with hydraulic d Designed for outdoor installation only
valve lifters for reliable performance without routine
valve adjustment or lengthy break-in requirements D Certifications
d Simple field conversion between natural gas and LP d Meets emission regulations for U.S. Environmental
vapor fuels while maintaining emission certification Protection Agency (EPA) phase 2 small off-road
engines and CA 2006 and later LSI engines with both
d Digital Spark Advance Ignition (DSAI) optimizes engine LP vapor and natural gas
performance for natural gas and LP vapor fuels
d UL 2200 listed
d Engine-mounted battery charging alternator
d Approved for stationary standby applications in
locations served by a reliable utility source
Generator Ratings
Model Alternator Standby Amps Standby Ratings, kW/kVA
Series Voltage Phase Hz Model Natural Gas LP Gas Natural Gas LP Gas
18RESL 120/240 1 60 2F5 70 75 17.0/17.0 18.0/18.0
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average
load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL
GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 1.5% per 5.5_C (10_F) temperature increase above 16_C
(60_F). Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your
local Kohler Co. generator distributor for availability.
* Due to the cycling operation of many electrical appliances, the generator set may not run all appliances simultaneously. Check the appliance manufacturer’s specifications for actual power
requirements. Consult a Kohlerr Power Systems professional for your exact residential power system requirements.
Available Accessories
Electrical System
- Battery
- Battery heater
Maintenance Dimensions and Weights
- Maintenance kit (air and oil filters) Overall Size, L x W x H: 1199 x 726 x 804 mm
- General maintenance literature kit (47.2 x 28.6 x 31.6 in.)
Weight: 227 kg (500 lb.)
- Overhaul literature kit Shipping weight with ATS: 254 kg (560 lb.)
- Production literature kit
Starting Aids
- Carburetor heater, 120 VAC (recommended for
reliable starting at temperatures below 0_C [32_F ] ) H
W L
NOTE: This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.