Panasonic Electric Works Deutschland GmbH

SOFT WARE

PLC UpDown
Version 2.60 January 2007 Program for data transfer Between PLCs from Panasonic and a personal computer

Note: This program can not read PLC program files which were written with FP WIN Pro or FP WIN GR . Copyright: Panasonic Electric Works Deutschland GmbH, Holzkirchen www.panasonic-electric-works.de Contact: Panasonic Electric Works Deutschland GmbH sps@eu.pewg.panasonic.com

PLC UpDown

BEFORE BEGINNING
Liability and Copyright for the Software and Hardware This manual and everything described in it are copyrighted. You may not copy this manual, in whole or part, without written consent of Panasonic Electric Works Deutschland GmbH. Panasonic Electric Works Deutschland GmbH pursues a policy of continuous improvement of the design and performance of its products, therefore, we reserve the right to change the manual/product without notice. In no event Panasonic Electric Works Deutschland GmbH be liable for direct, special, incidental, or consequential damage resulting from any defect in the product or its documentation, even if advised of the possibility of such damages.

LIMITED WARRANTY
If physical defects caused by distribution are found, Panasonic Electric Works Deutschland GmbH will replace/repair the product free of charge. Exceptions include: When physical defects are due to different usage/treatment of the product other than described in the manual. When physical defects are due to defective equipment other than the distributed product. When physical defects are due to modifications/repairs by someone other than Panasonic Electric Works Deutschland GmbH. When physical defects are due to natural disasters.

PLC UpDown

If you have any questions which are not answered by the reference manual or the online help, please call our Hotline:

Austria: 02236 / 2 68 46 Benelux: +31 (0)499 / 372727 France: 01 / 60 13 57 57 Germany: 08024 / 648 748 Ireland: 01 / 4 60 09 69 Italy: 045 / 6752711 Spain: 91 / 3 29 38 75 Scandinavia: 46 / 8 594766 80 Switzerland: 041 / 799 70 50 United Kingdom: 01908 / 23 15 55
All other customers, please contact your local distributors. Please help us by having the following information at hand: Your name and the name of your company Version number of PLC UpDown. Version number of MS Windows PC and PLC hardware What happened and what you did when the problem arose Exact message on the screen

PLC UpDown

1. Functionality
supports PLCs: FP0, FP-e, FP-Sigma, FP-X, FP1, FP2, FP3 and FP10SH. programs, system registers and all battery backup data can be read from PLC and can be saved as a *.NSU file on hard disc. Flash-ROM memory dates of FP0 and FPSigma (read with F12 and F13) can not be saved. programs saved as *.NSU file can be downloaded to PLC. COM1 to COM8 of personal computer are supported. baud rates can be set from 600 baud to 115200 baud. parity bit and number of bits can be set. monitoring of PLC copy function in PLC (RAM to ROM) is supported.

New in Version 2:
PLCs up to 120k steps program memory are supported. reset of PLC (memory). delete a password (PLC program is also deleted). save PLC data in decimal format on hard disc. possible to read *.NSU files from former versions.

New in Version 2.10:


PLC UpDown is supports german and english. Optional more languages. FP-2 is now supported. set a PLC password

New in Version 2.23:


COM1 to COM8 of personal computer are supported..

New in Version 2.25:


FP-Sigma with 16k Steps is now supported

New in Version 2.30:


FP-X C14, C30 und C60 PLCs

New in Version 2.31:


FP- Sigma with 32k Steps is now supported

New in Version 2.40:


New 8-character password for FP-X and FP-Sigma (32k) is now supported PLC Real Time Clock can be set with PC time

New in Version 2.50:


Datadownload to PLC is selectable Autobaud function

New in Version 2.60:


FP-X C14P, C30P und C60P PLCs

PLC UpDown

2. Installation and Starting


Before installing PLC UpDown, check whether your PC meets the following requirements: 80486 processor or higher 32MB RAM or more CD-ROM drive Hard disk with at least 50MB of available memory Graphic S--VGA adapter or compatible monitor Mouse Serial COM interface to connect your PLC

Furthermore, Windows 95, 98, ME, NT 4, 2000 or XP should be in place before you start installing PLC UpDown.

Note:
We assume that you are an experienced user of Microsoft Windows. Procedure:
1. Start Windows 2. Insert the PLC UpDown CD into the CD-ROM drive The browser should appear. 3. Carefully read the information displayed on the screen and follow the instructions Starting PLC UpDown

After successfully installing PLC UpDown, you start it like all other programs that run under Windows.

PLC UpDown

3. Removing
For removing PLC UpDown use only Windows functionality. Only program files were removed. NSU files are still available.

Note:
If you update to a newer version, you first have to remove the old version.

PLC UpDown

4. User Interface

4.1 Using Offline


PLC UpDown automatically starts with the last opened PLC program file. In the first line the loaded file is shown.

Button Load PRG loads a NSU program file from hard disk. Button Save PRG saves a program file on hard disk. The program file is not downloaded to PLC. Communication parameters do not need to be set in offline mode. If you push Online button, PLC UpDown tries to connect to PLC. If it fails to connect to PLC a timeout error is shown under connecting status:. Now all communication parameters could be changed until a connection is established. To change communication parameters you do not need to switch in offline mode. With every attempt to switch to online mode the symbol under progress is changed.

PLC UpDown

The basic settings of the commincation parameters are: FP1 : 19200 baud, 8 bits, odd parity FP0 : 9600 baud, 8 bits, odd parity.

4.2 Using Online


If a connection to PLC is established , data about the connected PLC type are uploaded to PLC info and function. Buttons to control PLC are active now.

PLC UpDown

Functions: Run / Prog: With this button you switch PLC to such mode which is shown on the button. You only can switch to an other mode if PLC is in no error mode. The current status is shown under status:. RAM -> ROM: This button is only active when the connected PLC supports a optional ROM memory. If the button is active a program can be exchanged directly between the RAM of a PLC and an EEPROM (optional EEPROM card has to be plugged in). If function is used with FP1 without plugged in ROM memory a self diagnostic error appears. This error is shown in separate window in red colour. PC -> PLC: With this function you download PLC program into PLC. A data transfer is only possible if: PLC program is the same type as connected PLC PLC is in Prog mode. PLC UpDown leads you through the work setps PLC -> PC: With this button you upload a PLC program into PC memory. The data are not saved automatically on hard disc. If a program was successfully uploaded from PLC it is noted in windows current data from:.
PLC program is uploaded from PLC but is not yet saved. File name is shown light gray if PLC program is uploaded but not yet saved on hard disc.

Data from connected PLC are shown if PLC program is uploaded from PLC

PC-Time -> PLC: With this button you can transfer the time and date from your personal computer to the PLC.

PLC UpDown

4.2.1 Password 4 character


This password menu is only available in online-mode. The 4 character password (hexadecimal format) is available in all PLCs that are developed up to the year 2004.

This functions are available: Set and activate a password. Delete a known password. Delete a password and all PLC data if the password is unknown. This can take a time from 5 seconds up to many minutes.

10

PLC UpDown

4.2.2 Password 8 character


This password menu is only available in Online-mode. The new PLCs FP-X and FP-Sigma V3 supports an secure 8 character password. This password is much more secure then the old 4 character password. Security advantages: up to eight character all ASCII character only three PW entry retries. Then power off/on for further three retries.

This functions are available: Program upload protection. If this function is active it is not possible to upload a program from PLC to PC. To deactivate this protection all data in the PLC will be delete and the baudrate of the tool-port is set to 9600 baud. Set and activate a password. Delete a known password. Delete a password and all PLC data if the password is unknown.

11

PLC UpDown

5. Monitoring
For PLC diagnostics up to three error messages are indicated.

Battery error: This error is self explaining. Programs which are not saved in ROM memory of PLC are lost if voltage of battery is low. Please use ROM memory like EPROM or EEPROM to save PLC program in PLC. PLC program error: A program error could be: division by zero, wrong parameter in a Panasonic program function. Self diagnostic error: This error appears if PLC hardware has problems. This error also appears if you try with FP1 to transfer a PLC program from RAM to ROM if ROM is not available. The error can be reset if PLC is switched off an on again. PLC password active: The connected PLC is protected with password. To download the PLC program to PLC the password has to be deleted. If password is deleted all data on PLC are deleted too.

12

PLC UpDown

6. Additional Functions
Additional functions can be activated by clicking symbol down to the right. After clicking on this symbol the active window additional detailed information:

Current settings of window are saved. If you start PLC UpDown again window uses saved settings.

13