Sunteți pe pagina 1din 90

AMOs

Siemens

AMOs

Contents
1 1.1 1.2 1.3 Administration and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Types of AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Loading operational tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 AMO Syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3.1 Structure of a command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3.2 The parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Syntax for AMO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Example of AMO Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Selecting Important Verbs and Nouns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Codeword variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 HiPath 4000 V6 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 License Management in the HiPath 4000 Assistant V6. . . . . . . . . . . . . . . . . . . . . . . . 24 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 AMOs in the User Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 WABE - Digit Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Structure of the DPLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Overview DARs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Overview of the CPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

2 2.1 2.2 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 4 5 5.1 5.2 5.3

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Siemens

AMOs

6 7 8 9 10 11 11.1 11.2 11.3 12 12.1

VBZ - Internal Traffic Restrictions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 COSSU - Classes of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 TAPRO - Key Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 SBCSU - Station and S0 Bus Configuration of SWU . . . . . . . . . . . . . . . . . . . . . . . 59 SCSU - Subscriber Configuration of Switching Unit . . . . . . . . . . . . . . . . . . . . . . . 63 Configuration of a Subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UP0/E - subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration of an IP subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Deletion of a Subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SDAT - Administration of Individual Subscriber Attributes and General Subscriber Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHANGE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.1.1 Changing Attributes / Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.1.2 Changing General Subscriber Data (Branch DATA) . . . . . . . . . . . . . . . . . . . 12.1.3 Changing Subscriber Data (Branch DATA1). . . . . . . . . . . . . . . . . . . . . . . . . DELETE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISPLAY-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REGENERATE-SDAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 65 69 70 71 71 71 71 71 72 72 72

12.2 12.3 12.4 13 14 15 15.1 15.2 15.3 16 17 18 19

BERUM - Class of Service Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 BERUZ - Times at which Class of Service Switchover is to Occur . . . . . . . . . . . 75 ZIEL - Destination Addresses for Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADD-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISPLAY-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REGENERATE-ZIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 80 80 80

ACTDA - Activation of User Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 PERSI - Personal Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 LRNGZ - List of Central Speed Dialing Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . 85 ZRNGZ - Central Speed Calling Digit Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

1
1.1

Administration and Maintenance


Types of AMOs

TYPES of AMOs

ADMINISTRATION

- Configuration of system peripherals - Administration of features - Administration of call charge registration parameters - Initialization of traffic metering

MAINTENANCE

- Trace and diagnostic evaluation (Debugger) - Blocking/unblocking of system units - Checking of system units

SYSTEM

Data file administration Access authorizations (passwords) Disk processing (CT, MT, HD) Memory update Date and time Database generation Documentation

REMOTE ADMIN. & MAINTENANCE (TELE-SERVICE)

- Transfer of fault messages - Starting of AMOs

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Siemens

AMOs

1.2

Loading operational tasks


SWU or CC Overlay Data D B A R z y AMO x Program AMC Polycom CMA Desktop for Apple ADP Polycom CMA Desktop for Apple OS free memory z y AMOx Tables I/O LAN or V24Asy PC
Subsystem Tables Subsystem Program AMO y AMO z AMO x HD

AMC MMI LDU

IDE/SCSI

ADS AMC AMO BTT

Administration and Data Server Administration and Maintenance Control Administration, Maintenance and Organization Operating Terminal

HD I/O LDU MMI

Hard Disk Input/Output Logical Device Unit Man Machine Interpreter

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

1.3

AMO Syntax

The AMO (Administration, Maintenance and Organization) stands for administration and maintenance tasks that are needed for setting up, managing, troubleshooting, maintaining and commissioning the HiPath 4000 system. It is primarily a script language that is checked for correct syntax by the system. Tips are stored to provide the user with helpful information. Syntactically incorrect entries are rejected by the system and the AMO enters a so-called prompt status. It requests entry of the correct values. Syntactically correct but functionally incorrect entries are not queried. Thus, for example, all executive-secretary groups can be accidentally deleted by an unintentional command.

> An AMO never asks whether you really want to delete everything.
1.3.1 Structure of a command

VERB
ADD CHANGE DISPLAY START STOP USW.

NOUN:
SBCSU: PERSI: DATE: COPY: GEZAB: USW.

The VERB, or the action that is to be executed, is separated from the command, the NOUN, by a minus sign. Between the invocation and the following parameters, a colon is used as a separator from the parameters. The NOUN can also be entered in a short format.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Siemens

AMOs

1.3.2

The parameters

After the invocation command, the necessary parameters are entered. Parameters that the AMO needs in order to fulfill its function and that cannot be replaced by its own values. One example is the station number of a subscriber. Parameters that must be set but that can be supplemented through default values or own search entries. Parameters that have optional functions. These are generally not entered.

Mandatory parameters

Selectable mandatory

Freely selectable parameters

Parameters can be numerical and alphanumerical values. To set up a subscriber, you require the SBCSU command (Subscriber Bus Configuration Switching Unit) and the SETUP verb.. ADD-SBCSU:STNO=4711&4713&&4719,OPT=OPTI,PEN=1-1-25-12;,....................; One option for administration is the keyword-oriented entry. The parameter(s) are named and entered, which can also result in chains linked with a "". Parameter&Parameter&& Parameter, If you would like to set up the same devices multiple times, you can also create the link with "&&", in which case the execution is from value to value. Up to ten links are possible. The individual parameters are separated by a comma. In addition to the keyword-oriented entry, a position-oriented entry is also possible. In this case, you need to know the position of the parameters and comment out those that are not required. A mixture of both parameter entry types is not possible. ADD-SBCSU:4711&4713&&4719,OPTI,1-1-25-12;,,,,,,,,,,,; A semicolon is always placed at the end of an entry. This is performed automatically by the system when the AMO is run through but can also take place during entry if no other entries are needed. If parameters are still missing after all, the AMO outputs a query. You can enter a "?" or "??" for each query. You are then given a tip.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Syntax for AMO Input


PARAMETER, PARAMETER ....; PARAMETER NAME =PARAMETER VALUE or POSITION-DEPENDENT PARAMETER (VALUE)

COMMAND CODE: ACTIVITY VERB ADD ( ) [ ] <> { : ; } FUNCTIONS NOUN AUN

EXPLANATORY TEXT PASSAGES PARAMETER NAME and PARAMETER VALUE may be entered. Name of PARAMETER VALUE, all possible values are explained separately.. Entry of at least one PARAMETER, rest optional Separating COMMAND CODE and PARAMETER Separating ACTIVITY and FUNCTIONS OF THE COMMAND CODE END of AMO INPUT

PARAMETER NAME = PARAMETER VALUE One of the given PARAMETER VALUES must be assigned to the PARAMETER NAME. PARAMETER NAME = <PARAMETER VALUE> An individual value, a string of individual values, or a group of individual values must be allocated to the PARAMETER NAME. [PARAMETER NAME = <PARAMETER VALUE>] Optional input of PARAMETER NAME, PARAMETER VALUE. & & && I <number> <param> <string> <key-num> <a-b-c...> <identifier> <name> = STRING of INDIVIDUAL VALUES GROUP of INDIVIDUAL VALUES OR GATING - one of the given parameters is entered up to the semicolon as an alternative. PARAMETER consists of DECIMAL NUMBER(S) PARAMETER VALUE consists of LETTERS A...Z, DIGITS 0...9 PARAMETER VALUE consists of CHARACTERS (all except ', ) PARAMETER VALUE consists of CHARACTERS 0...9, A...D, *, # PARAMETER VALUE consists of PARAMETER ARGUMENTS PARAMETER VALUE consists of CHARACTERS (A...Z, 0...9) 1. character is a letter <param>

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Siemens

AMOs

2.1

Example of AMO Input


Procedure Overview Command Code Parameter TYPE =SYS; I TYPE = COPIN, [COPIN=<number>] ; I TYPE = MODULO ; I TYPE = NAME, [STNO=<number>] ; I TYPE = PIN, [PIN=<string>] ,[PINTYPE=<number>] ; I TYPE = STN, [STNO=<number>], PINTYPE=<string>] ; I TYPE = CCMS, [CCMSCD=<keynum>],[DPLN=<number>],[STNO =<number>] ;

DISPLAY-PERSI

Procedure Overview
Command Code DISPLAY-SCSU Parameter [STNO]=<number>, e.g.ITYPE =COS, COSNO=<number>;

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

2.2

Selecting Important Verbs and Nouns

The maximum number of inputs for the AMO for the verb (action) VERB ADD CHAnge DISplay DELete REGenerate Test Copy EXEC STArt STOP DUMP COLLECT ACTivate DEACTivate SWITCH NOUN PERSI PERSI PERSI PERSI PERSI APS APS UPDAT INFO BELIN APS SELS DSSU DSSU DSSM

AMO - code explained in the BCSU example

B board S L U D C T A subscriber line unit device cabinet trunk attendant

C configuration (console) S switch/subscriber D display

SU switching unit SM server module VM voicemail module

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Siemens

AMOs

10

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

3
3.1

Protection of software features (codeword)


Feature description

Features are sold in feature packages. Each package is allocated a marketing value. The feature quantities purchased by a customer are encrypted as an alphanumeric "codeword". The new hardware, HiPath 4000 V2, features a SIM card on the DSCXL board (ADP). The dongle used for existing hardware is upwards compatible. However, if the system is upgraded to Hipath 4000 V2.0 then a new codeword has to be installed. New hardware: SIM card on the DSCXL board (ADP) Old hardware: Dongle for existing systems

The dongle or the SIM card and the codeword "tell" the system which feature packages and quantities were purchased by the customer. When the system is configured, a special plausibility check is used to ensure that the configuration data corresponds to the purchased features and quantities.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

11

Siemens

AMOs

PNE

ComScendo

CC-AP for AP Emergency

Remote Survivability

Cordless E

Voice compression IP

Entry Agent CODEWORD

Protection of software features

12

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

3.2

Codeword variants

In HiPath 4000 V2.0 and later, the CODEWORD will feature four variants: 1. Normal mode: This is the approved operating mode as implemented in HiPath 1.0. In normal mode, a codeword and licenses are requested for all relevant licenses in the database. Trial mode: This feature introduces a time-limited trial mode. When you activate trial mode, you can skip the license restrictions that are temporarily displayed. During this time, the AMOs work as if unrestricted licenses were available except that an advisory message is sent to the users if license restriction violations occur. Emergency mode: The system activates the Emergency mode, in case of special situations. Special situations are: Validity of the Codeword is expired; Dongle resp. SIM card is missing; Codeword is missing; Dongle resp. SIM card does not match to Codeword; In the Emergency mode the AMO execution is blocked in the SWU. The only AMOs that can be executed are the AMO CODEW / DATE. Escalated Emergency mode: The feature triggers an additional system operation restriction (it blocks the FEASU feature) when the system is in escalation mode for an extended period of time. This restriction is known as escalation of the Emergency mode.

2.

3.

4.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

13

Siemens

AMOs

CODEW variants with dongle in HiPath 4000 at V2.0

TYPE

Description

Dongle Sim Card X X X X X X

TYPE 1 (Customer) standard: 2 x Test mode each for 30 days (then a new Codeword is required) TYPE 2 (Special) Via LMT (Licence Management Tool) with a time limit of 60 days or an agreed time limit Via LMT (Licence Management Tool) without a time limit

In a network the network codeword from the Hipath 4000 Manager (LMT) is used. The original Codeword must be added previously in the system. The Network codeword then overwrites the Codeword on a daily basis. If this does not happen then a 60 day test mode begins. The 30 Day Service-Dongle will no longer be given in Hipath4000 V2.0. The creation date is coded in the Codeword and is stored in the database, when the Codeword is added in the system. The possibility to add an older Codeword is blocked in this way.

14

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

3.3
Unit

Codew description
Description Counting/marketing per configured B channel/analog channel to: AMOs ACSU BCSU Parameter ACTYPE=AC4/ACW2Q/ACWMQ TYPE=SIGNOFF RECAPL=ACDR/ACDMUS/ HMUSIC DVCFIG= ANAFAX/ANADTE/ANADEV/ FAX/DTE/OPTIP500/OPTISET/S0PP/S2PP/SET600/ OPTIIP DVCFIG=ANATE/ANATECM/ AUXDIGI TYPE=GENANS/MSGR/EXTANN/CC/VMXMWI

COMSCENDO

station (optiset = 1 B chan- RCSU nel; optiset E or optiPoint 500 ... with adapter = 2 B chanSBCSU nels; optiip = 1 B channel, but max. 2 B channels per Up0E) or attendant console SCSU SSC

SBCSU ART=OPTIERW Trunk or tie (including ATM Networking) TACSU DEVTYPE=TC/TC1/TC2/NW/ TT/TT1/TT2/TT3/TT4 TDCSU DEV=S0COD/S0CONN/ S1COD/S1CONN/S1PVC/ S1SVC/LAN/S1PVCCO/ S2COD/S2CONN/S2PVC/ S2SVC/S2PVCCO/VCCOD/ VCCONN/HG3550/CDGCONN/CDGCOD/30/ATMSVC/ATMPVC3/ATMPVC7/ ATMPVC15/ATMPVC23/ ATMPVC2X/ATMPVC30/ ATMPVCCO TSCSU DEV=CC/CCM/ANS/RA/RAS/ DICT/SPKR/DOOR CORDLESS E Counting/marketing of the acti- SBCSU DVCFIG=BASE vation license per B channel (for example SLC16 to base station) irrespective of the operating software

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

15

Siemens

AMOs

Unit PNE

Description

AMOs

Parameter

Counting/marketing per VPN B TDCSU DEV=S2CONN channel configured from/to the board with PNEDIUS2 line type (use the AMO BGDAT to check the line type of a board) AGENT AGTID=<number>

HIPATH PROCounting/marketing per active CENTER ENTRY (logged in) agent AGENT HIPATH AP REMOTE SURVIVABILITY

Counting the IPDA survivability APRT remote shelves for connections over ISDN (ID9206) (AMO SIPCO parameter SURVNET)

CONF=ROUTER/AP

CC-AP FOR AP EMERGENCY

Counting/marketing per CC con- APESU DATA=CCAP figured for AP Emergency

3.4

Service information
The counters bear no relationship to the feature dimensioning values administered with the AMO DIMSU. For the purposes of software feature protection, "ComScendo" is the equivalent of "station" for the following components: Optiset E optiPoint 500 / optiPoint 400 / optiPoint 410 ANATE ANATECM AUXDIGI Signed off TSI instead of signed off station PP (all S0/S2) FBUS (all call numbers)

The dongle or the SIM card is immediately activated on startup. The validity of a codeword may be limited to a specific period. It is calculated in days from the creation date.

16

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

The expiry date is shown after each LOGON command or after the initial ADD command. You can also check the date with the DISPLAY-CODEW command. A new codeword is needed every time the purchased quantity is expanded. (Except "HIPATH AP VOICE COMPRESSION IP" where only the coding is dynamically changed (from G.729 to G.711) when the limit is reached.) The purchased quantity can be temporarily expanded in trial mode (see Section 1.2). An installed codeword only can be replaced by a new one. The creation date is saved in the codeword; the serial number is used for information purposes only. The codeword can be changed with the codeword tool. The hardware ID and codeword must match. In order to enter a codeword the date of the system must be valid. In the event of contractual violation, the user interface is disabled and you are prevented from starting any more SWU AMOs (for configuration). If the system prevents access although the codeword and dongle are valid, you can activate the dongle with the following actions: unplug/plug in the dongle, enable line8 or perform an A1 soft restart. Further information on the AMO CODEW can be found in the AMO description in the service manual.

3.5

Generation (example)
Add a codeword (dongle or SIM card must be inserted): ADD-CODEW:CODEW1= W1RAZWX6HPK8HS5G39TKV6X9MKVAM9ENERJTVTZBDX34KFNHRUTP4GU1EC132N93, CODEW2=LJJ9MKK381DASTYEZNNU67366HMWAM33VVKKRKG7UHTDUGFWJN2PBBREGX;

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

17

Siemens

AMOs

Display counters for purchased quantities / configured quantities: 1. Customer Dongle / SIM (TYPE 1 - Codeword)

DISPLAY-CODEW; H500: AMO CODEW STARDED

SALES UNIT COUNTERS ===================

CODEWORD: AFTKSB3CJYN4LKZN7GNWZH8TXH63M29A5GA2L2JN261LGKEA8CPHLZV5UGKHVPHP XGRZDWDF83BG6BLE2U6LSP8GYS8VY5NADW88BUAE6RA58HXMD2N99TJSC9 VERSION : H205

SERIAL NUMBER: 7 HARDWARE ID ENTRY DATE TRIAL MODE : C6EB8F3B : 22.02.2004

: NOT ACTIVATED

CONFIRMATION : 3706

+---------------------------------------------+-------+-------+-------+-------+ | | | UNIT | | CON| | USED | | | | |

FREE |BLOCKED| | |

| TRACT |

+---------------------------------------------+-------+-------+-------+-------+ | | | | | | COMSCENDO CORDLESS E PNE HIPATH PROCENTER ENTRY AGENT SIGNALING SURVIVABILITY CC-AP FOR AP EMERGENCY | | | | | | 976 | 0 | 0 | 0 | 0 | 0 | 913 | 0 | 0 | 0 | 0 | 0 | 63 | 0 | 0 | 0 | 0 | 0 | | | | | | |

+---------------------------------------------+-------+-------+-------+-------+ H07: THE TEST MODE IS AVAILABLE (ANOTHER) 2 TIMES.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU DISPLAY COMPLETED;

18

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

2.

Dongle / SIM with TYPE 2 - Codeword

DISPLAY-CODEW;
DISPLAY-CODEW; H500: AMO CODEW STARTED

SALES UNIT COUNTERS ===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72 R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R VERSION : H205

SERIAL NUMBER: 0 HARDWARE ID ENTRY DATE VALID UNTIL TRIAL MODE : 7ED439FB : 07.01.2004 : 17.12.2005 : NOT ACTIVATED

CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+ | | | UNIT | | CON| | USED | | | | |

FREE |BLOCKED| | |

| TRACT |

+---------------------------------------------+-------+-------+-------+-------+ | | | | | | COMSCENDO CORDLESS E PNE HIPATH PROCENTER ENTRY AGENT SIGNALING SURVIVABILITY CC-AP FOR AP EMERGENCY | | | | | | | | | | | | 110 | 0 | 0 | 0 | 0 | 0 | | | | | | | | | | | | |

+---------------------------------------------+-------+-------+-------+-------+ H12: CURRENT CODEWORD IS A TYPE 2 CODEWORD.

AMO-CODEW-111 DISPLAY COMPLETED;

CODEWORD FOR ADMINISTRATION LOCK IN SWU

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

19

Siemens

AMOs

Trial mode The purchased quantity can be temporarily expanded with trial mode. Trial mode is activated with CHANGE-CODEW. Utilization is not unlimited (maximum number specified in codeword, generally 2) and has a maximum utilization time (generally 30 days). SWU administration is not disabled even if license violation is shown in trial mode ("!!!!!" in the "FREE" column). A mark that can be displaced with the AMO SDSU is applied to elements that exceed the license limit (stations, trunks, etc.). The number of units marked is also displayed in the AMO CODEW. Trial mode is automatically terminated if not manually deactivated within the maximum time limit. When this happens, marked elements are disabled for security reasons and can only be enabled if an appropriate codeword is set up. No elements are marked or disabled for the features HIPATH PROCENTER ENTRY AGENT and HIPATH AP VOICE COMPRESSION IP. However, when trial mode ends, no agents above and beyond the license limits can log on and compressed connections cannot be set up. Trial mode does not apply to the features HIPATH AP REMOTE SURVIVABILITY and CC-AP FOR AP EMERGENCY. The codewords license limit cannot be exceeded here.

Activate trial mode: CHANGE-CODEW:TRIAL=YES; ....(activated after consultation)

Administration above and beyond the quantities purchased: ADD-SCSU:STNO=4711,DVCFIG=ANATE;

20

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Display codeword the test mode is expired: DISPLAY-CODEW;


DISP-CODEW; H500: AMO CODEW STARTED

SALES UNIT COUNTERS ===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72 R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R VERSION : H205

SERIAL NUMBER: 0 HARDWARE ID ENTRY DATE VALID UNTIL TRIAL MODE : 7ED439FB : 18.12.2003 : 17.12.2004 : NOT ACTIVATED

CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+ | | | UNIT | | CON| | USED | | | | |

FREE |BLOCKED| | |

| TRACT |

+---------------------------------------------+-------+-------+-------+-------+ | | | | | | COMSCENDO CORDLESS E PNE HIPATH PROCENTER ENTRY AGENT SIGNALING SURVIVABILITY CC-AP FOR AP EMERGENCY | | | | | | 110 | | | | | | 110 | !!!!! | 0 | 0 | 0 | 0 | 0 | | | | | | 1 | | | | | |

+---------------------------------------------+-------+-------+-------+-------+ H12: THE TEST MODE IS AVAILABLE (ANOTHER) ONCE.

AMO-CODEW-111 DISPLAY COMPLETED;

CODEWORD FOR ADMINISTRATION LOCK IN SWU

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

21

Siemens

AMOs

3.6

HiPath 4000 V6 Licensing

A new license concept based on the HiPath License Management (HLM) is used. The SIM card is not used anymore. A HiPath 4000 V6 Flex License pro Port for all HiPath 4000 subscriber and Trunking connections is available: analog, digital, HFA, SIP, Cordless, PSTN and SIP Service Provider.

22

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

HiPath 4000 V6 Flex License subscriber analog digital IP (HFA or SIP) trunk analog TDM per user per user per user per channel per channel

Cornet IP Trunk and SIP Trunk for HG3550 per channel Common Gateway SIP Trunk for HiPath 4000 SoftGate SIP Service Provider Mobility System IP Access Point SoftGate 50 Cordless Enterprise Base License HiPath 4000 V6 Duplex Control Signaling Survivability Survivability Unit (AP-Emergency) Base License SoftGate 50 package SoftGate 1000 Basis License SoftGate 1000 package OpenScape 4000 V6 CSTA connectivity CSTA CSTA connectivity with SEN Application Packet 10 User for 3rd party Application part of the HiPath 4000 V6 base packet part of the HiPath 4000 V6 base packet HiPath 4000 V6 Basis and Survivability License per system per system per AP3x00IP per AP-Emergency Server per SoftGate Server max. 50 User and max. 50 active connections per SoftGate Server max. 1000 User and max. 256 active connections no license required per channel per channel base station

Packet 100 User for 3rd party Application per CSTA Application Link Unlimited Packet for 3rd party Application per CSTA Application Link Table 3-1

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

23

Siemens

AMOs

After a first configuration with the Portal automatically a grace period license will be generated. This license is valid for 30 days. A customer license must be created with MAC address (e.g. eth0 of the DSCXL2 board) and L-number. The created .lic file can be downloaded with the Assistant. The Assistant creates a Codew for the RMX.

3.7

License Management in the HiPath 4000 Assistant V6

With the menu HiPath 4000 Assistant V6 --> Access Management --> License Management the license can be downloaded and displayed.

24

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

The link Display installed license data shows the licenses in detail, e.g. duration of validity.

The link Display Server MAC address display the possible MAC addresses for the creation of the licenses.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

25

Siemens

AMOs

The Link Display license details shows the actual used license data.

26

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

In the menu HiPath 4000 Assistant V6 --> Access Management--> Licence Management --> Tool you can get information about the licenses, e.g. alarms.

3.8
AMO

Relevant AMO
Parameter CODEW1 CODEW2 CODEW1 CODEW2 TESTMOD TRIAL LICMARK LICBLOCK Sprache/ Beschreibung/ Description Language d d e e d e d d e e Erster Teil des Codewortes Zweiter Teil des Codewortes First part of codeword Second part of codeword Testmodus ein/ausschalten Activate/deactivate trial mode Markierte Lizenz (im Testmodus) Gesperrte Lizenez (Testmodus abgelaufen) Marked License (in testmode) Blocked License (testmode expired)

EINR-CODEW ADD-CODEW AE-CODEW CHANGE-CODEW AB-SDSU

DISP-SDSU

LICMARK LICBLOCK

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

27

Siemens

AMOs

28

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

AMOs in the User Area


WABE
Dialing plan User no. WABE group

LRNGZ
SPDC lists and Speed dialing No. List no.

VBZ
ITR matrix ITR group

COSSU
Classes of service COS no. LCOS (V/D)

TAPRO
Standard

ZAND ZANDE
STN No.

SXSU SCSU / SBCSU


Per STN No. personal and device-related data RNGZ 1, 2 COSX group ITR group
STNNo.

STN Exchange of Voice Terminals

TACSU
Line config. individual night STN

SDAT
Administration of subscr.-related features.

HOTLN ZRNGZ
Hotline/ Code blue Destinations

TGER
Sharing of NV terminals

TAPRO
Key programming indiv.

SPDC dest. call numbers

VBZA
ITR matrix ID card, ID card reader

NAVAR
Night options

PERSI
Personal identification PIN / Name

BERUZ
COSX time controlled

SA
Hunt group data

CHESE
Exec./secretary system
Secretary

BERUM
COSX manually controlled

AUN
Call pick-up group

SSC
Special Subscr. MESSENGER Messenger no.

RCSU
Adding music per user

RUFUM
Number mapping combi-code

ZIEL
Dest. no. for MESSGR, FWD, No.Redial, SPDI, DSS, Name, dest. key

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

29

Siemens

AMOs

AUN BERUM BERUZ CHESE COSSU HOTLN LRNGZ NAVAR PERSI RCSU RUFUM SA SBCSU SCSU SDAT SSC SXSU TACSU TAPRO TGER VBZ VBZA VBZGR WABE ZAND ZANDE ZIEL ZRNGZ

Call pick-up groups Class-of-service changeover Class-of-service changeover times Executive/secretary system (integrated outer office system) Classes of service Destinations for HOTLINE/CODE BLUE Lists for central number generator Administration of the stat. night variant data Personal identification Announcement devices in the SWU Number mapping Hunt group Terminals and S0 bus configuration in the SWU Configuration of users in the SWU Administration of user-related features Configuration of special users Reconfiguration of user voice terminals Configuration of analog line ports Key programming for digital terminals User devices assignment Internal traffic restriction (ITR) matrix ITR for users with ID card readers ITR groups Dialing assessment Central system data Central system data - extended Destination addresses for users Central number generator destinations

30

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

WABE - Digit Analysis

"Digit analysis" refers to the assignment of a digit analysis result (DAR) to a dialed digit sequence or code. This assignment is dependent on the call progress state (CPS) and digit analysis group or dial plan (DPLN). There are two types of digit analysis result: DARs with a specific dialing outcome (e.g. STN; dialing result is station number), and DARs whose dialing outcome must be defined in other AMOs (e.g. CO; the trunk routes which can be accessed via this DAR are defined with the AMO RICHT).

5.1

Structure of the DPLN

Digit Analysis is comprised of a general DPLN (WABE) part and one of 16 DPLN groups.
DPLN - General Part (valid for all dial plans)
DIS-WABE:GEN;

Here are listed all codes for those digit analysis results (DAR) which are to be accessible for all stations (valid for all dial plans). All stations (DAR=STN) must be listed here. DPLN 0 DPLN 1 Codes for digit analysis results (DAR) in this area are only accessible for stations belonging to DPLN 1. Station Number 4511 DPLN 2 . . .14 DPLN 15

Displays only the general part!

DIS-WABE:GEN,1;

Displays all DPLN entries for stations with DPLN 1. (DPLN general part and DPLN 1) If STN is assigned to DPLN 1, SCSU/ S(B)CSU must have parameter DPLN=1. With this he gets access to all codes of the DPLN valid for all DPLN groups as well as the codes of DPLN 1.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

31

Siemens

AMOs

5.2

Overview DARs

General DARs ALL ACBK DCBK ACOSX DCOSX ADND DDND ANSCO ANSINT APIN1 to APIN 15 DPIN AREM DREM ATND ATNDDID ATNDIND BABYLSNG BUZZ CDRACC CO CTDL DICT DIGIDAT DISUOFF All DARs Activate callback Delete callback or line queueing Activate cos changeover from station Deactivate cos changeover from station Activate do not disturb Deactivate do not disturb Answering device for central office Answering device, internal Activate PIN for COPIN 1 to Activate PIN for COPIN 15 Deactivate PIN Activate reminder Deactivate reminder Attendant / internal operator code Indial to attendant console Individual attendant console Baby listening Alert (buzz) a target station CDR account code Central office Seize lines Dictation equipment DIGITE data input Display suppression off

32

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

DISUON DOORCL DOOROPEN DTE DTED DTMFCONV EOVR EXTANS FAX GATEWAY GENANS HOLD KNOVR LNR MANDOWNL MHFALGOF MHFALGON NETRTE NETW NETWDTE NETWFAX NOPT OUTPULSE OWNNODE PUEXT

Display suppression on Query of the entrance telephone system Open via the entrance telephone system Code for DTE service for analog traffic via DIUC Code for DTE service for digital traffic via DIUC DTMF conversion when dailing to public network Emergency override (feature emergency override/release) Interception by console in partner system Code for Fax service Gateway General answering / universal night answering Call hold by an analog phone Camp on (knocking) / override Last number redial Manual downloading Logoff by a mobile HFA subscriber Logon by a mobile HFA subscriber Auxiliary DAR for networking DAR for a voice feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated DAR for a DTE feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated DAR for a FAX feature in another node, route is automatically seized via DESTNO and the dialed digit sequence is repeated Change of night switch option Outpulse specific digits on the line during call status for cut-through or suffix dialing in tie traffic Code number for own node Acceptance (or pickup) of ext.consult call from remote system in simple tie trunk traffic

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

33

Siemens

AMOs

RA RELEASE REMKY RESDOWNl SIGNOFF SIGNON SNR SPD SPDC1 SPDC2 SPDI SPDIPROG SPLIT STN STNREL TRACE VOICECAL WHISANN

Recorded announcement for a specific area Release (feature emergency override/release) Reminder Key Reset of modified parameters by downloading the basic parameter sets (DCI) Sign off a line via terminal device (Autoset Relocate) Sign on a line via terminal device (Autoset Relocate) Stored number redial Change the speed (DCI) Speed dialing central 1 Speed dialing central 2 Speed dialing individual Speed dialing individual programming code Split / alternating calls Station STN DAR for destination dependent release Malicious call tracing Voice call Whisper Announcement

DARs for call forwarding feature for voice service AFWDVCE DFWDVCE AFFWDVCE DFFWDVCE for Fax service AFWDFAX DFWDFAX Activate call forwarding fax Deactivate call forwarding fax Activate fixed call forwarding voice Deactivate fixed call forwarding voice Program and activate fixed forwarding voice Deactivate and delete fixed forwarding voice

34

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

AFFWDFAX DFFWDFAX for DTE service AFWDDTE DFWDDTE AFFWDDTE DFFWDDTE

Program and activate fixed forwarding fax Deactivate fixed forwarding fax

Activate call forwarding DTE Deactivate call forwarding DTE Activate fixed call forwarding DTE Deactivate fixed call forwarding DTE

Activate via the attendant console AFWDREM DFWDREM FWDREM Miscellaneous AFWDDWD FWDTERM FWDIGNOR DFWDEXT AFWDEXT DFWDINT AFWDINT AFWDEXIN AFWDB AFWDNA AFWDBNA DSYSFWD ASYSFWD FFWDREMK Activate call forwarding for DIGITE without display Call forwarding for all STNs assoc. to terminal Ignore call forwarding Deactivate call forwarding external Activate call forwarding external Deactivate call forwarding internal Activate call forwarding internal Activate call forwarding internal Activate call forwarding busy Activate call forwarding no answer Activate call forwarding busy or no answer Deactivate system call forwarding voice Activate system call forwarding voice Store call forwarding via remote by key Activate call forwarding remote / follow me Deactivate call forwarding remote / follow me Show call forwarding remote / follow me

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

35

Siemens

AMOs

DARs for call pickup feature PU PUGDIS PUDIR Call pickup Display group pickup information on request Directed call pickup

DARs for call park feature PARK CALLPARK DCPA SELFPA RECONNPA Call park and retrieve to system slot Call park for anate Park a user at a specific user Park a user on ones own line Reconnect on held call

DARs for combi code feature DTEDNE DTENO FAXNO Combi code for DTE terminal with digital traffic via DIUC Combi code for DTE terminal with analog traffic via DIUC Combi code for FAX terminal

DARs for hunting group feature HUNT HTKY AHTVCE DHTVCE AHTFAX DHTFAX AHTDTE DHTDTE Hunting group (HT) Hunt group key (on / off) Add station to hunt group voice Disassociate stn from hunt group, voice eqpt. Add station to hunt group fax Disassociate station from hunt group, fax eqpt. Add station to hunt group DTE Disassociate stn from hunt group, DTE eqpt.

36

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

DARs for code calling feature (Single code calling / multiple code calling) CCKY CCDIS CCMEETME CCSTN CCVCE CCSURG CCS CCANS CCSCD CCSN CCMANS CCMSURG CCMS Code calling key Code calling display with code Code calling meet me with code Code calling station A with code Code calling for voice with code Code calling urgent search with code Code calling normal search with code Code calling answer Code calling search with code Code calling search normal Code calling answer to multi task page attempt Code calling multiple paging urgent Code calling multiple task paging normal

DARs for tie traffic feature (network / wide features) TIE TIEATND SCONSCO SCONSI SAT Tie line access Analogue tie line, special seizure type Sat. connection in consultation hold from CO Sat. connection in consult hold from internal Extend indial or trunk call to satellite system

DARs for IP Distributed Architecture (IPDA) feature FRCALTRT INCALTRT NOEC Force alternate route Incoming alternate route CLC without echo cancellation for encrypted calls

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

37

Siemens

AMOs

DARs for key function assignment KYPROG KNOVRKY DNDKY IUSEKY FWDKY MSGRKY MBKY DAKY VCRKY VCKY DSSKY EXHOLDKY HOLDKY CONFKY TOGGLEKY NAMEKY PARKKY PRIVKY CONSKY CBKKY RCTOFFKY HTKY FLASHCD STKY RLSKY TRNSKY TIMEKY Key programming on digite Knocking / Camp on, override key Do not disturb Show line key i use key Call forwarding key Messenger key (CHESE) Mailbox key Non-Voice key Voice call reject key Voice call key Direct station select key Exclusive hold key Hold key Conference key Toggle key Name key Park key Privacy key Consultation key Callback key Ringer cutoff key Hunt group key (on / off) Equivalent flash signal code Start key / output Release / Cancel key Call transfer key Time / date key

38

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

LNRKY SNRKY

Last number redial key Saved number redial key

DARs for answering machine functions MBON MBOFF VMOWN VMFOR MWACT MWANS MWCAN MWCANORI Mailbox LED on Mailbox LED off Access to own voice mailbox Access to other users voice mailbox Message waiting activation Message waiting answer Message waiting cancel by terminating party Message waiting cancel by originating party

DARs for broadcast functions BROADCST COMGRP COMSPK SPKRCALL speaker call - one way broadcast COM group call COM group speaker call - two way Speaker call - one way

DARs for conference features CONFKY CONF RMCONFLP RMCONFP1 to RMCONFP8 Conference key Establish conference / add party to conference Remove last party from conference Remove party at position 1 from conference up to Remove party at position 8 from conference

DARs for MLPP features FLASH FLASHOV MLPP flash call MLPP Flash Override call (high level)

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

39

Siemens

AMOs

IMMED PRTY DSNR

MLPP immediate call MLPP priority call (low level) MLPP dsn routine

DARs for call center features ACC ACDWORK ACDSHMSG ACDLOGON ACDLOGOF ACDEMMSG ACDNAV ACDPGS ACDPQS ACDSGS ACDSQS ACDAV CAFDFWD CAFAFWD CAFGROFF CAFGRNAV CAFGRAV CAFLOGOF CAFNAV CAFAV MONSLNT MONTONE RCG Account code Agent work Short message Agent logon Agent logoff Emergency message Agent not available Primary group status Primary queue status Secondary group status Secondary queue status Agent available CAF deactivate forwarding of RCG CAF activate forwarding of RCG CAF group logoff CAF group not available CAF group available CAF agent logoff CAF agent not available CAF agent available Silent monitoring Tone monitoring Route control group number

40

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

DARs for key functionality feature IUSEKY EXHOLDLKY HOLDKY KEYPADIE TOGGLEKY APRIV DPRIV PRIVKY CONSKY CBKKY RCTOFFKY RLSKY TRNSKY LNRKY SNRKY Show line key i use key Exclusive hold key Hold key Keypad IE Toggle Key Activate privacy Deactivate privacy Privacy key Consultation key Callback key Ringer cutoff key Release / Cancel key Call transfer key Last number redial key Saved number redial key

DARs for national features PROT ASTN CALLPARK OPROVR DCPA SELFPA RECONNPA RERING CTDL OUTPULSE Override protection (Belgium) Check a Station number in the case of transit Call park for anate Demand to override by CO operator in call status Park a user at a specific user Park a user on one own line Reconnect on held call Ring partner again Line seizure for cut through or suffix dailing in tie traffic Suffix transmission of digits on the line during call status for cut through or suffix dailing in tie traffic

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

41

Siemens

AMOs

DARs for the Optiset API feature WSS Start workstation session

DARs for service functions FLTRACE FREQTEST CTLS HWTEST TESTLN TESTTONE COMBO LOOPBACK MILLWAT SILENCE PRITEST Activate the flag trace Test the DTMF and MFC transmitters Controlled Trunk and Line Selection Start the HW test of the terminal (optiset) Test line Connect test tone transmitter for 800hz test Combination test (transmission test termination) Loopback test (transmission test termination) Milliwatt test (transmission test termination) Silence test (transmission test termination) Primary rate test line loopback

42

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

5.3

Overview of the CPS

Possible AMO values: 0 - 22 (from Version V 2.3 -- V 3.x ) 0 Auxiliary CPS for networking (DAR NETRTE) 1 Suffix dialing (station / attendant) 2 Switching of in-house call at attendant console 3 Switching of central office call at attendant console 4 Prefix dialing at attendant console 5 Prefix dialing by station 6 CO incoming DID 7 IDN connection from CO incoming DID 8 Consultation of station user from in-house call 9 Consultation of a station user from CO call 10 Incoming station line traffic 11 Incoming tie line traffic 12 Incoming link traffic 13 Seizure from satellite PABX for data traffic 14 CHECK mode on attendant console 15 CHECK mode on HICOM terminal 16 Seizure in private network 17 Seizure during consultation in private network 18 Single code calling device: code digits in suffix dialing 19 Expiration of time supervision 20 Function assignment to key on HICOM terminal 21 Used only in USA 22 Consultation of station user from conference

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

43

Siemens

AMOs

Associated pairs for simultaneous processing are listed in Table 5-1 and pairs for sequential processing in Table 5-2. Digit analysis results AFWDVCE, ADND and ACOSX can also be used as 'feature toggling' digit analysis results. Thus, in the case of these digit analysis results, it is no longer necessary to handle them in pairs with the corresponding deactivation digit analysis results.

Add simultaneously DAR 1 AFWDREM AFWDDTE AFWDFAX AFFWDDTE AFFWDFAX AFFWDVCE ACBK AHTDTE AHTFAX AHTVCE AREM VMOWN MBON Table 5-1 DAR 2 DFWDREM DFWDDTE DFWDFAX DFFWDDTE DFFWDFAX DFFWDVCE DCBK DHTDTE DHTFAX DHTVCE DREM VMFOR MBOFF Digit analysis result pairs

Must be entered in sequence Enter first SPDC1 CCS CCMS Table 5-2 Enter second SPDC2 CCSURG CCMSURG DAR pairs for sequential processing

There are more features connected to special DARs, e.g. there are only decimal digits allowed with DAR STN or FLASHCD, also only 1 digit is allowed for DAR FLASHCD

44

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Function:

ADD CHA DISPLAY DEL REG

Assign digit analysis results Change digit analysis results Delete digit analysis results Display digit analysis results Regenerate digit analysis results

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

45

Siemens

AMOs

46

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

VBZ - Internal Traffic Restrictions

The internal traffic restriction matrix regulates communications among the traffic groups (ITR groups). Stations and trunks are combined into ITR groups which have an identical traffic restriction matrix, i.e. which have the same traffic restrictions to other ITR groups. Relations between ITR groups can be set up and changed as desired with the ITR matrix. Only a portion of the total communications of the switching unit is regulated with the ITR matrix. The matrix is only queried when the dialing outcome is a station (also master station in a hunt group). The following traffic relations between two groups are possible:

A = allowed D = denied

Thus directional traffic restrictions between two ITR groups can also be regulated.

E.g.:

ITR-Gr 05 --> 03 allowed ITR-Gr 03 --> 05 denied

The traffic relation within one group must always be allowed. For that reason, the diagonal line of the matrix may not be altered (always contains the entry "A"). A second static matrix is used to regulate traffic relations between card users and card readers. This matrix is administrated by the AMO VBZA. The features "controlled station restriction" and "controlled station restriction - group", as well as "controlled station-to-station restriction", do not affect the ITR matrix. For these features, a separate table exists, which is administrated by the AMO ACTDA. The ITR matrix is created from the database and initialized with A (= allowed). As a result, an ADD branch for the AMO VBZ is not necessary. Function:

DISPLAY CHANGE REGENERATE

Interrogate the ITR matrix Change the ITR matrix Regenerate the ITR matrix

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

47

Siemens

AMOs

48

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

COSSU - Classes of Service

The classes of service contain combinations of authorizations and features and are assigned to one ore more stations (AMO-ACSU, AMO-SBCSU, AMO-SCSU resp. AMO-SSCSU). Classes of service are also assigned to trunks for call traffic (AMO-TACSU, AMO-TDCSU resp. AMOTSCSU). Each class of service is divided into 3 services: Voice (VCE) Facsimile (FAX) Data Terminal (DTE)

Table 1 shows the COS authorizations, a description of the authorization, the service in which each authorization is applicable, and whether an autorization effects a station and/or a trunk. This table is only a compilation of classmarks. It does not allow you to establish cross-references between the different authorizations. The -without direct trunk access- and -without tie trunk access- authorizations for the specified service are indicated by the fact that the direct trunk access and tie trunk access authorizations are not set for the corresponding service.

COS 0 is not a valid class of service. LCR classes of service Change, display, and regenerate LCR classes of service, each with up to 64 LCR authorizations and LCR options (for example, LCR expensive route tone). Sixty-four LCR classes of service are permanently configured, 32 of which are for voice, fax, and 32 of which are for data. LCOSV=1 is initialized for the attendant console with all the authorizations. The others are initialized without contents and edited by means of the branch CHANGE

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

49

Siemens

AMOs

Authorization

Description General Classmarks

Service VCE.FAX .DTE

Application STA ...TRU

ACTMAN ANSYN APHOT ATRACE BASIC BDCP COIN COSXD CTLS DATA DICT DSSKEY DPSTN DSM DNDOVR DIDBLK FAX GRPCAL HGICLD HOT INATCP LOCCPV MANOV MB

Manual CDR Account Code possible Announcements with synchronized start of text Application hotline Automatic station number identification Basic device authorization Disable selective call pickup Coinbox telephone Class-of-service changeover with code Selective trunk and station dialing Non-voice data authorization Dictation authorization KEY functionality with DSS key Dial pulsing Access to service module (DTE) Override do not disturb DID barring Access to service module (FAX) Group call Hunt group code in call party number HOT Hotline International call in private network Local connection in private network Manual override Mailbox (authorization to read mail)

X X X X

X X X X

X X X X X X X X X X

X X

X X X X X X X X X

X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X

50

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Authorization MTRACE NOARNO NOCHRG NOPTCD NPINDP OFHKRC PINAFM RKOABS REVCHA RSVLN SPKR SUBEPP SUTVA TOLLPV TRACE TRANSG TTT VCE

Description Manual station number identification Ports to which recall is not permitted Without call charges Change night service variant of an AC group via code No pin for dailing pattern required Off hook recall PIN Identification and Follow-Me in one step Absolute override/camp-on security Reception of a collect call Access to reserved trunks Loudspeaker announcement authorization Consulting party is responsible for call charges Station can transfer before answer National call in private network Automatic call trace Indirect access to private network Transfer Trunk to Trunk Access to service module (Voice )

Service VCE.FAX .DTE X X X X X X X X X X X X X X X X X X X X X X X X

Application STA ...TRU X X

X X X X X

X X X

X X

General Country-Specific Authorizations PRCO PRCO1 PRISTN TSUID External party with priority External party 1 with priority Station with priority External party identification Call Forwarding CFB Call forwarding on busy X X X X X X X X X

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

51

Siemens

AMOs

Authorization CFNR CFSWF FWDBAR FWDECA FWDEXT FWDNWK

Description Call forwarding on no reply Automatic changeover to fixed call forwarding after deactivating variable call forwarding Prevent call forwarding CF-EXT as a function of COS 1 / 2 Extended call forwarding Call forwarding to exchange

Service VCE.FAX .DTE X X X X X X

Application STA ...TRU X X X X

Emergency Override/Emergency Disconnect AOBTR REOVR Autom. emergency override to busy trunk Rejection of emergency override/disconnect X X X X

Direct Trunk Access and Tie Trunk Access Authorizations NOCO RTA TA NOTIE RTIEA TTCR11 TTCR12 TTCR13 TTCR14 TTCR15 TTCR16 TNOTCR Without direct trunk access Restricted trunk access Unrestricted toll access authorization Without tie trunk access Restricted tie trunk access Partial tie trunk access authorization 1 Partial tie trunk access authorization 2 Partial tie trunk access authorization 3 Partial tie trunk access authorization 4 Partial tie trunk access authorization 5 Partial tie trunk access authorization 6 Tie trunk access authorization EURO-ISDN Terminals MSN MULTRA OVCAT Multiple Subscriber Number Multi-Trans (called terminal seized several times) Override Category X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

52

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Authorization SPECAR SUBCAL SUBDB SUBMSN

Description Special arrangement B is notified of A station number B is notified of default B station number B is notified of MSN

Service VCE.FAX .DTE X X X X X X X X X X X X

Application STA ...TRU X X X X

Services on DSS1 - Multi-Device Connection CCBS COLR CW MCIDM MCIDA TP UUS1IM UUS3 Completion of calls to busy subscribers Connected line identification restriction Call waiting Malicious Call Identification - manual Malicious Call Identification - automatic Subscriber not in call pickup group Implicit use of UUS1 service Use of UUS3 service X X X X X X X X X X X X X X X X X X X X X X X

QSIG + DSS1 to the Public Exchange FWDBAS FWDDIR FWDFAS KIESIG Call forwarding programmed by another subscriber Activation, deactivation and display of incoming call forwarding Call forwarding programmed for another subscriber Keypad IE signaling possible X X X X X X X X X X X X X X X X

Call Charge Identification for Data Selection CDRATN CDRC CDRINT CDRSTN CDRS Call detail recording at attendant console Call detail recording central Call detail recording of internal call Call charge display during the call Call detail recording per station X X X X X X X X X X X X X X

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

53

Siemens

AMOs

Authorization

Description

Service VCE.FAX .DTE

Application STA ...TRU

Features for Public Telephones with Metering Pulses (these class marks can be released on a country specific basis only) MTEQ PUPHON SCRNCA SCRNCB SCRSPC Maintenance equipment Public telephone Station with no charge party A SCRNCB Station with no charge party B Station with special call detail recording China Service Documentation Spain Service Documentation ANI outgoing GUS Service Documentation GUS Stufe 2&3 Service Documentation X X X X X

Functions

ADD CHANGE DELETE DISPLAY REGENERATE

Add a Class of Service Change of Classes of Service Delete Classes of Service Display Classes of Service Regenerate Classes of Service

54

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

TAPRO - Key Programming

The AMO TAPRO is used for loading the programmable key functions of digital and IP voice terminals. Various standard or individual key assignments can be loaded. The AMO TAPRO also allows individual key functions to be changed. Furthermore, the AMO is used for the administration of the standard key assignments. As Spirit IP Phones will be configured using the already existing opti-IP device configuration, the required TAPRO functionality to allow administration of Key Layouts for Spirit IP Phones (with or without Key System Functionality) is already present. TAPRO is extended to delete information on which type of Electronic Key Label shall be used and which individual text shall be used for the Electronic Key Label In the generation sequence, AMO TAPRO is called at two points in the batch: before AMO SBCSU to change standard key assignments, and after AMO SBCSU/SSCSU to change individual keys Functions The AMO TAPRO can be used for the following terminal types:

optiset E T3 / T8 / T12 optiPoint 500 T8 / T12 / T19 optiPoint 600 T19 optiPoint 4x0 T8 / T12 / T19 optiPoint WL2 professional OpenStage 10, 15, 20, 30, 40,60 and 80 OpenClient as well as the various add-on terminal types

With the AMO TAPRO, it is not necessary to set up the standard key assignments, since all 127 for optiset valid standard assignments for each terminal type are already stored in the database. All terminals are allocated one of these standard assignments when they are first configured.

The terminal will be not deactivated from the AMO TAPRO, exception deletion of DSS keys. If the terminal was deactivated before the processing, it remain deactivated. A standard key layout with add-on terminal can be assigned to a subscriber OPTISET without add-on terminal, but only the key functions of the basic terminal are accepted.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

55

Siemens

AMOs

Zulssige Angaben und ihre Bedeutung Basic terminal(s) Add-on terminal(s) No terminal type specified

Options for STD,STNO STD STND

Load new std. key layout Load new standard key Error message for sp. basic terminal type layout for add-on terminal F03 Load new function for freely-prog., ind. keys at sp. STNs with sp. (basic) terminal type Load new function for Load new function for freely-programmable, in- freely prog., ind. keys at div. keys at specified spec. terminals add-on terminal. Load new std. key layout at spec. STN and freelyprog. key functions at basic terminal.

STNO and STD

Load new standard key Error message layout plus new functions F05 for freely-prog., ind. keys at spec. STNs with spec. (basic) terminal type.

DISPLAY-TAPRO:TYPE=STN,STNO=7243; +--------------+----+---------+------------------------------------------------+ | STATION |STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |

+--------------+----+---------+------------------------------------------------+ | 7243 |101 | OPTISET | |

+--------------+----+---------+------------------------------------------------+ CHANGE-TAPRO:STD=101,DIGTYP=OPTIT19,KY09=DSS;

DISPLAY-TAPRO:TYPE=STN,STNO=7243; +--------------+----+---------+------------------------------------------------+ | STATION |STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |

+--------------+----+---------+------------------------------------------------+ | 7243 |101 | OPTISET | 9 DSS |

+--------------+----+---------+------------------------------------------------+

56

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Function

CHANGE DISPLAY

Change a standard key layout Change freely-programmable key layout Display standard and freely-programmable key layouts Display standard key layouts Display freely-programmable key layouts Regenerate standard and freely-programmable key layouts Regenerate standard key layouts Regenerate freely-programmable key layouts

REGENERIATE

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

57

Siemens

AMOs

58

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

SBCSU - Station and S0 Bus Configuration of SWU

The AMO SBCSU configures terminal devices (stations) at S0 bus connections, S0 interfaces, Up0/E interfaces, IP interface and on the ATM switch. A maximum of one voice terminal may be assigned to an S0 bus. A maximum of three terminals with three different station numbers can be set up per Up0/E access. Apart from configuring stations, the AMO SBCSU offers the options of displaying, regenerating and changing the associated data, as well as cancelling station assignments. The AMO SBCSU assigns all station combinations which contain the following terminals. All other station combinations are assigned with the aid of the AMOs SCSU or SSCSU.

The following terminals are configured for the VOICE service: OPTISET: Digital telephone for Up0/E interface and CorNet-TS protocol OPTIP500: Digital telephone for Up0/E interface and CorNet-TS protocol OPTIIP: Digital telephone for IP interface and CorNet-TS protocol SET600: Digital telephone for S0 interface and EDSS1 (EURO-ISDN) or NI-BRI protocol ANADEV: Analog voice terminal (connected to Up0/E via terminal adapter a/b) Terminal equipment for Cordless Multicell Integration (CMI Version >= V2.2): BASE: CMI base station with Up0/E interface and CorNet-TS protocol RADIO: CMI mobile user with Up0/E interface and CorNet-TS protocol EXTLINE: CMI Extension connection with S0 interface and EDSS1 (EURO-ISDN) protocol Voice terminal equipment with SIP or S0 or S2 interfaces

The following terminals are configured for non-voice services only: API: Workstation protocol interface and CorNet protocol (DATA service) ANADEV: analog non-voice terminal (DTE and FAX) (connected to Up0/E via terminal adapter a/b)

DTE: digital DTE with S0 interface, EDSS1 (EURO-ISDN) protocol digital DTE with U2B1Q interface, NI-BRI protocol digital DTE with V.24 interface (connected via terminal adapter), EDSS1 (EURO-ISDN) protocol

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

59

Siemens

AMOs

digital DTE with U2B1Q interface (connected via terminal adapter), NI-BRI protocol analog DTE (connected to S0 via terminal adapter a/b and modem)

FAX: Group 2 and 3 (connected to S0 via terminal adapter a/b) Group 4, EDSS1 (EURO-ISDN) or NI-BRI??? protocol

Non-voice terminal equipment with S0 or S2 interfaces, e.g. DP systems, LANs, Servers.

The type of non-voice terminal equipment for DTE and FAX connected to S0 (analog, digital S0, digital X.21) is not taken into account for the purpose of assignment in this AMO. In addition to the terminal name, only the protocol type parameter DPROT resp. FPROT must be declared. The terminal attributes, which are not relevant for assignment purposes, are determined when the terminal first responds to a polling message at the bus connection or the station line circuit. The terminals are assigned to the following modules: SLMS (S0 interface) (to Hicom H V1.0) STMD STMD2, STMD3 DIU-N2, DIU-N4 DIU-S2 SLMQ SLMQ3 SLC16 / SLC24 SLMO, SLMO16, SLMO24, SLMOP, SLOP2 STHC, STHC2 STMA STMI-HFA STMI2, STMI4 (S0 interface) (to Hicom H V1.0) (S0 interface) (S2 interface) (S2 interface) (ANSI-U interface) In the case of extremely long lines (from 1-2 km up to 9 km) (U2B1Q interface) (Up0/E interface) (Up0/E interface) (combination of STMD and SLMO, i.e. S0 as well as Up0/E interface) (IWU to the ATM switch) (HFA gateway version 1 to IP) (HFA gateway version 2 to IP)

60

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Functions

ADD

Configuring the static and dynamic memories in the CC and the LTGs for the above-described device combinations as well as entering the static device data Changing the static device data . Deleting specific service assignments or an entire station configuration Interrogating existing station configurations Regenerating existing station configurations

CHANGE DELETE DISPLAY REGENERATE

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

61

Siemens

AMOs

62

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

10

SCSU - Subscriber Configuration of Switching Unit


ANATE to SLMA, SLMA2, SLMA3, SLMA24, SLMAB, SLMAR, SLMAC, SLMAE Charge Metering ANATE (ANATECM) to SLMAR AUXDIGI to SLMB, SLMB4

AMO SCSU is used to configure ports for the connection of the following terminals:

The digital terminals at S0/Up0/UpoE such as SET600/OPTISET/OPTIP500 are set up using AMO SBCSU. Special subscribers (e.g. Hicom Trading Board subscribers) are configured by AMO SSCSU. Each STN number can be assigned personalized data such as names or personal identification numbers (PIN) using AMO PERSI. AMO TGER is used to assign additional station numbers to non-voice terminals which have already been assigned a number (AMO SCSU/SBCSU). It is also possible to configure "virtual" ports for all device types which have not been assigned to a module but are configured in the same way as regular physical ports. Virtual ports are identified as INS=FLOAT or INS=ACLSTN. These ports are used by any ID card user who identifies himself at another terminal by inserting his ID card or by keying in the PIN, and who then makes the call using the features of his virtual port such as classmarks, speed dialing digit series etc.. An ANATECM is not allowed to be configured as virtual port. It is also possible to install a signed off fictive station by depicting INS=SIGNOFF. A signed off station can only be an ANATE. Signed off stations can be signed on

by entering a PIN-Number and a key number at the specific terminal or by being signed on terminal by means of service staff by administration command (AMO DSSU)

Signed off stations can be added to communication groups such as pick up groups, hunting groups etc. This allows a complete preconfiguration of subscribers. For "virtual" ports (e.g. INS=FLOAT) PEN-specific parameters (e.g. COFIDX) are ignored. A suffix-dialing connection is required for connecting special facilities such as VMX servers. This connection is identified as SPEC=SUFDIAL and parameterized using the parameter DHPAR. For special stations (e.g. COMTEL) and for special country specific adaptions in SLMA1/ SLMA2/SLMA3/SLMA24/SLMAB/SLMAR-Loadware parameterization can be done by using parameter DHPAR. Some special subscribers like Voice Pagers etc. are configured using parameter SPEC.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

63

Siemens

AMOs

Functions

ADD

Configuring the static and dynamic memories in the CC and the LTGs for the above-described device combinations as well as entering the static device data Changing the static device data . Deleting specific service assignments or an entire station configuration Interrogating existing station configurations Regenerating existing station configurations

CHANGE DELETE DISPLAY REGENERATE

64

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

11
11.1

Configuration of a Subscriber
UP0/E - subscriber

Configuration of an optiPoint 500 subscriber with a description of the parameter and cross references to the related AMOs.

New subscriber number: Related AMO: WABE DAR=STN has to be reserved (R), destination number (DESTNO) = 0

PEN: optional parameter, system is using the next free PEN of a SLMO24/SLMOP, if the parameter PEN isnt used. Related AMO: BCSU/SDSU

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

65

Siemens

AMOs

Authorizations (COS)- and LCR-Authorizations (LCOS) classes LCOSV for service voice LCOSD for service data 1 for day authorization 2 for night authorization Related AMOs: - for content: COSSU, SDAT - for LCR: LDPLN, LDAT

DPLN-group 0-15 Standard=0 Related AMO: WABE

COSX-group 0-15 Standard=0 Related AMOs: BERUM, BERUZ for switching FEASU: COSXCD, COSXDB, COSXKEY, COSXATND, COSXT WABE: DAR ACOSX/DCOSX PERSI: PIN for COPIN 7 for the STN

ITR-group 0-15 Standard=0 Related AMO: VBZ

Secret station number If yes is selected, the setting of the AMO ZAND instead of PERSI is used. Related AMOs: ZAND: ALLDATA2, DISPNUUM=XXX If ONLYEXT is selected, it is possible to transmit an other number instead of the extension number. Related AMO: KNMAT: MODCON=REPEXT

Central speed calling lists: 0-15 SPDC1: table 1 SPDC2: table 2 16 code for deleting Related AMOs: LRNGZ, ZRNGZ DIMSU: SPDCL, SPDCD FEASU: SPDC WABE: DAR SPDC1, SPDC2

Speed Calling Individual 0, 10, 20, 30 destinations Related AMOs: DIMSU: SPDI FEASU: SPDI WABE: KZP=SPDI and SPDIPROG ZIEL

66

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

IDCR Station with identity card reader

Number of add-on devices dependent of the device: 0-4

Secretary Subscriber is secretary of a CHESE executive-secretary group Related AMO: CHESE

Key layout standard Standard=0-127 Related AMO: TAPRO

Station in service yes/no or signed off (no PEN is used)

Alarm number 0: no alarm assigned 8-519: number of directional alarm group 520-583: number of personal alarm group Related AMOs: VADSU Reject call back on busy Attention to parameter CBKBMAX in AMO SBCSU. Related AMOs: FEASU: CBK, DCBB, DCBNOA ZAND: ALLDATA, CBKNO (number of callbacks for a STN activated in case of busy or no answer)

Max. number of callback 1-5 or 99 Attention to parameter RCBKB in AMO SBCSU Related AMOs: FEASU: CBK, DCBB, DCBNOA ZAND: ALLDATA, CBKNO (number of callbacks for a STN activated in case of busy or no answer)

Reject call back on no answer Attention to parameter CBKBMAX in AMO SBCSU. Related AMOs: FEASU: CBK, DCBB, DCBNOA ZAND: ALLDATA, CBKNO (number of callbacks for a STN activated in case of busy or no answer)

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

67

Siemens

AMOs

Headset WITHIND Headset with HW indication NOIND: Headset without HW indication Attention to parameter HSKEY in AMO SBCSU

Function of the HS key (Head set key) NORMAL: HS key must be used for answer HSGIND: HS key for indication of the head set Related AMO: TAPRO

Callback on no answer is stored in the mailbox Attention to parameter RCBKNA in AMO SBCSU Related AMOs: FEASU: CBK, DCBB, DCBNOA ZAND: ALLDATA, CBKNO Text selector for display Related AMOs: ZAND: ALLDATA2, TEXTSEL In ACTIVE TEXTSEL up to 5 languages can be selected. An user should select the language with a key: TAPRO: key LANSEL SDAT: Attribute LNGDYN or LNGSTAT

68

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

11.2

Configuration of an IP subscriber

An IP-device like e.g. optiPoint 400, optiPoint 410, optiPoint 420 and optiPoint 600 will be configured in principle like a UP0/E subscriber. Additional resp. other parameters will be shown in the next part.

IP: connected to a STMI IP2: connected to a STMI2

Password for IP login procedure.

Codec, used by the Resource Manager.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

69

Siemens

AMOs

11.3

Deletion of a Subscriber

70

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

12

SDAT - Administration of Individual Subscriber Attributes and General Subscriber Data

The AMO SDAT can be used to administer subscriber-related attributes and features for the voice service. It can process subscribers who have been added with the AMO SCSU, SBCSU, or SBCSU. It can also be used to administer general data that is independent of any particular device.

12.1 12.1.1

CHANGE-SDAT Changing Attributes / Features

When attributes are changed (added / removed), compatibility checks are carried out to test the following: a) b) c) whether the attributes entered - or those already existing - are compatible with each other, whether the attributes entered are compatible with the type of equipment belonging to the subscriber, whether the attributes entered are compatible with special subscriber data

When attributes are added for ACD SUPERVISOR a check is carried out to establish whether there are sufficient purchased subscribers of this type. When an ACD attribute is removed, a check is carried out to establish whether there are still ACD group relationships.

12.1.2

Changing General Subscriber Data (Branch DATA)

In this branch, it is possible to change general subscriber data that is independent of any device. This data consists of parameters that are processed in the AMO SBCSU and in the AMO SCSU and SSCSU. The checks correspond to the checks in the AMO with which the subscriber being changed was added.

12.1.3

Changing Subscriber Data (Branch DATA1)

In this branch, it is possible to change additional subscriber data. This data consists of parameters that are processed with AMO SDAT only. AMO SBCSU, SCSU and SSCSU can not process this data.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

71

Siemens

AMOs

12.2

DELETE-SDAT

The action DELETE-SDAT can be used to delete specific subscriber attributes which were configured with CHANGE-SDAT, TYPE=DATA1. PUBNUM When deleting PUBNUM the parameters TON and NPI are deleted, too.

12.3

DISPLAY-SDAT

The action DISPLAY-SDAT results in the following: 1. In the branch SUBDATA the general subscriber data and the subscriber-related attributes / features of a subscriber are output in tabular form. In the branch SUBFIND subscribers with a particular subscriber-related attribute / feature are output in tabular form. In the branch SUBOV the assigned device and the AMO used to add the subscriber are output in tabular form for the subscribers entered. In the branch NNOFIND subscribers with a particular NNO are output in tabular form.

2.

3.

4.

12.4

REGENERATE-SDAT

The action REGENERATE-SDAT can be used to restrict the output to subscribers with particular subscriber-related attributes / features.

72

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

13

BERUM - Class of Service Switchover

Stations are allocated two classes of service (COS1 and COS2) in (COS1 = normal or day COS COS2 = alternative or night COS) in their line tables. The class of service are maintained by AMO COSSU and assigned to stations with the AMOs SCSU and SBCSU. An identifier (COS pointer) in the line tables indicates which COS is active. AMO SCSU and AMO SBCSU subdivides the stations into COS switchover groups (COSX groups). This is performed in order to group stations so that a certain COS can be switched active for all of them. If no specific allocation has been made, a station belongs to COSX group 00. Stations with an active key switch (KEYSTN) are not changed over, but they are still assigned to a COSX group. The COSX groups are independent of other station groups formed on the basis of other features. Switchover between the two classes of service can be performed from a station, from an attendant console, centrally using the AMO, via data channel and/or by means of a timed switchover. a) COS Switchover from the Station A station authorized for this type of switchover can switch over between the COSs using the personal ID number (PIN) and a code for switchover using an active key switch (KEYSTN). As long as the alternative COS (COS2) is active, the user hears the special dial tone when he lifts the receiver. The station is assigned the authorization COSXCD (COS switchover by code) by AMO COSSU in order to be able to perform a switchover using the PIN. The PIN (maximum of 12 digits) is defined by the AMO PERSI. b) COS Switchover from the Attendant Console (ATND) Switchover of the normal COS of the COSX groups to an alternative COS can be performed from every attendant console, including the night attendant console (performed with the task BEZUM). c) COS Switchover by AMO COS switchover for COSX groups of stations can be performed using the AMO BERUM. d) COS switchover using a data processing system (DVA) is implemented via a data channel.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

73

Siemens

AMOs

e)

Automatic COS Switchover The COS switchover for COSX groups can be carried out automatically at a specific, definable time. This time is defined using the AMO BERUZ (time table for times at which class of service switchover is to occur). Switchover is carried out by the task BEZUM.

Priorities for COS Switchover The last COS switchover performed for a station is always in effect, regardless of where this change was carried out (from the station, from the attendant console or automatically).

Function: CHANGE-BERUM; DISPLAY-BERUM:

74

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

14

BERUZ - Times at which Class of Service Switchover is to Occur

Stations (configured by AMO SCSU and AMO SBCSU) are allocated two classes of service COS1 and COS2) in their line tables. A class of service contains the authorizations of a station. An identifier (COS pointer) in the line tables indicates which COS is active, i.e. which of the stations authorizations are currently activated; this is usually COS1. AMO SCSU and AMO SBCSU subdivides stations into COS switchover groups. This is performed in order to group stations so that a certain COS can be switched active for all of them. The COSX groups are independent of other station groups formed by other features. If no specific allocation has been made, a station belongs to COSX group 0. Stations with an active key switch (KEYSTN) are not switched over, but they are still assigned to a COSX group. The classes of service can be switched over from a station, from an attendant console, y means of AMO BERUM, via data channel, and/or by means of a timed switchover. Switchover at a fixed Time (timed Switchover) A table is created in the database, in which the following data is entered for each day of the week and for each COS switchover group:

A time at which COS1 is switched to active (COS1T), A time at which COS2 is switched to active (COS2T), A program switch indicating whether the displayed switchover to COS1 is to be carried out on that day (COS1), A program switch indicating whether the displayed switchover to COS2 is to be carried out on that day (COS2).

AMO BERUZ administrates this table. (The switchover is carried out with the task BEZUM.)
MON(1) COSX 0 06.55 15.40 off/on 06.55 15.40 on/on 00.00 00.00 off/off TUE(2) 06.55 15.40 off/on 06.55 15.40 on/on 00.00 00.00 off/off WED(3) 06.55 15.40 on/on 06.55 15.40 on/on 00.00 00.00 off/off THU(4) 06.55 15.40 on/on 06.55 15.40 on/on 00.00 00.00 off/off FRI(5) 06.55 15.40 on/on 06.55 15.40 on/on 00.00 00.00 off/off SAT(6) 00.00 00.00 off/off 00.00 12.00 on/on 00.00 00.00 off/off SUN(7) 00.00 00.00 off/off 00.00 12.00 off/off 00.00 00.00 off/off

COSX 1

............................... COSX15

(COSX = Class of service switchover group)

Table 14-1

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

75

Siemens

AMOs

Function: ADD-BERUZ: DISPLAY-BERUZ: REGENERATE-BERUZ:

76

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

15

ZIEL - Destination Addresses for Stations

This AMO is used to enter, interrogate or regenerate destinations in the database (DB) for the following features:

Call forwarding - fixed (FWD) Messenger Call (MSGR) Direct station select keys (DSS) Name/repertory key (NAME) Individual speed dialling (SPDI) Saved Number Redial (SNR) Attendant Console Direct Destination Select keys (DDS) Destinations for the BUZZ Feature

AMO-ZIEL is also used to add, delete, interrogate or regenerate for:


dialing external servers to deposit messages identifying external servers when retrieving messages with the START key

Call forwarding - fixed Two forwarding variants are possible:

STATION forwarding can be added or deleted by AMO ZIEL or by the subscriber, and activated or deactivated by the subscriber or by AMO ACTDA. SYSTEM forwarding is a new forwarding type Adding and deleting destinations is only possible by AMO ZIEL, whereby different destinations can be entered for different forwarding types (eg.busy, no response), immaterial, if the incoming call is internal or external. The forwarding can be activated or deactivated by AMO ACTDA, or by the subscriber using the relevant codes. Call forwarding on no response The fixed call forwarding destinations do not act ad destinations for call forwarding on no response any more. These can be added as fixed destinations for forwarding type CFNR (no response) or CFB (busy) in the SYSTEM forwarding (AMO ZIEL), and activated by AMOACTDA, or can be added and activated as variable forwarding (CFNR or CFB) (AMO ACTDA).

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

77

Siemens

AMOs

Fixed destinations can be created for each service. This AMO however does not activate or deactivate forwarding. Destinations can be entered in the services VCE (voice), FAX and DTE. Destinations for devices working to the DSS1 protocol can only be activated as variable forwarding destinations by AMO ACTDA. Destinations can be entered for all created STNOs (station numbers) with the exception of attendant terminals, irrespective of whether or not the station concerned has any terminal devices. The following diversion types can be used: for SYSTEM forwarding

CFU (Call Forward Unconditional) CFB (Call Forward Busy) CFNR (Call Forward No Reply) CFDND (Call Forward Do Not Disturb)

for STATION forwarding

CFU (Call Forward Unconditional)

Messenger Call The members of an integrated executive/secretary system can have a messenger call key on their voice terminal for which a fixed destination can be entered. This destination can also be programmed at the administration and maintenance terminal. Only analog stations are permitted. Direct station select keys Direct station select (DSS) keys can be assigned to all terminals. The key functions for OPTISET and Optipoint 500 are defined with the help of the AMO TAPRO. Only internal destinations are possible (analog telephone, digital voice terminal, and personal attendant call number). In addition to entering the destination in the database, the AMO ZIEL also enters partner information for the destination station (controls the lamps in the DSS key). Name/repertory key The key functions for the OPTISET and Optipoint 500 are defined with the help of the AMO TAPRO. Destinations can only be entered after the key functions have been defined. The destination entry may be any combination of digits comprising a maximum of 22 characters. Destination entries may be protected against changing and deleting by the destination terminal user, using parameter PROTECT=YES. Changing or deleting by AMO will be possible furthermore. Name/repertory keys of OPTISET / Optipoint 500 add on terminals have two levels to store destination entries. A level can be selected by entering a value for parameter LEVEL.

78

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

Individual speed dialling Stations that are permitted to use the SPDI are provided an SPDI list when created by means of AMO SBCSU. Stations with an analog telephone, a voice terminal, mobile users (without a device, but with a separate terminal connection), and DTE stations may use the SPDI. Voice terminals can also used name/repertory keys and DSS keys. Saved Number Redial Each analog telephone and voice terminal can store a dialed number with up to 22 digits for redial. The destination can be any combination of digits (0-9,*,#,A,B,C,D). Attendant Console Direct Destination Select keys Each attendant console has 42 destination (DDS) keys

40 destinations via the destination keys 2 destinations via R1, R2 keys (trunk group keys for reserving lines).

The destinations are entered into a storage area that can hold up to 42 The configuration is carried out when the attendant console is created by means of AMO ACSU. The destination keys write memory locations 1-40, while the trunk group keys R1 and R2 are always defined at locations 41 and 42. Destinations for the BUZZ Feature The buzz feature allows a user to alert (buzz) a predefined keyset or DFT (optiset and optiPoint 500) by pressing the BUZZ key or by keying an access code. Voice communication is not possible. Buzz causes the target keyset or DFT to be alerted and the originators station number to be displayed for two seconds. The buzz target (destination) and the originator must be located in the same node.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

79

Siemens

AMOs

15.1
Example

ADD-ZIEL

A fixed call forwarding destination for diversion type CFNR to STNO 3101 for the VOICE service can be created for voice station 2100. Input:
ADD-ZIEL:TYPE=FWD,SRCNO=2100,SI=VCE,DESTNOF=3101,DTYPE=CFNR,ITYPE=GEN ,CFVAR=SYSTEM;

15.2
Example

DISPLAY-ZIEL

Interrogate the call forwarding destination for station 2100. Input:


DISPLAY-ZIEL:TYPE=FWD,SRCNO=2100;

Output:
FWD SOURCE | SERVICE | DTYPE | ITYPE | CFVAR | DESTINATION -------+----------+-------+---------+---------+----------------------2100 | VCE | CFU | INT | SYSTEM | 3140

15.3
Example

REGENERATE-ZIEL

Regenerate the call forwarding destination for station 2100. Input:


REGENERATE-ZIEL:TYPE=FWD,SRCNO=2100;

Output
ADD-ZIEL :FWD,2100,VCE,2100,VCE,3101,,CFNR,GEN,SYSTEM;

80

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

16

ACTDA - Activation of User Features

The AMO ACTDA is used to regenerate feature-specific data entered by a user via the terminal. The functions DISPLAY, REGENERATE, ADD and DELETE are implemented. The AMO enables these data to be saved while the software version (APS) is being changed. Using the DISPLAY function, the user data recorded by ACTDA can be displayed on the administration and maintenance terminal. A command batch is generated with the REGENERATE function, based on the user data. This command batch is used for reinitializing the database. The ADD function initializes the database with the user data. The AMO ACTDA is used mainly for regenerating data. In addition, it can be used for test purposes. In special cases it can be necessary to deactivate the activated call forwarding of a station. This function has been implemented in the branch DELETE.

TYPE STN DND FWD OPTISET OUTHUNT RCUTOFF REMIND REPSECR RNGXFER VCR ATNDGR ITR NOPT DNDGR ISTR MOBHFA MLOGOFF MLOGON Do-not-disturb

Feature Fixed call forwarding Variable call forwarding individual optiset E / optipoint 500 settings switch out of hunt group Ringer Cutoff Timed reminder Deputy for secretary Ring transfer Voice call rejection Night variant for ATNDGR Group do-not-disturb function Controlled station-to-station restriction Controlled station-to-station restriction for all ISTR groups Logoff of mobile hfa-user Logon of mobile hfa-user

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

81

Siemens

AMOs

Some user data is already administrated by other AMOs. These data are not additionally administrated by ACTDA. AMO CHESE ZIEL Feature-specific data Secretarial transfer function destinations Individual speed dialing numbers Call numbers for stored number redial Name/repertory key data for DIGITEs DSS (direct station selection) destinations Messenger call destinations Name/repertory key data for ATNDs TAPRO BERUM Store key functions for DIGITEs Data for class-of-service changeovers (individual, group, all)

Function: ADD-ACTDA: DELETE-ACTDA: DISPLAY-ACTDA: REGENERATE-ACTDA:

82

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

17

PERSI - Personal Identification

The AMO PERSI is used to administer personal data. The cross-reference to the person is invariably established via the station number. a) Names Each station number can be assigned either one or several (any number of) names; the name entered first will be displayed on DIGITE displays. All other names are used for ETD functions. The name can also be made up of 2 parts: 1. 2. Surname, simple or composite, e.g. Hr. Meier, Fr. Dr. Huber Name, and additional information, e.g. Anna, Dept. A3 The characters of the "surname" are separated from those of the "name" by means of a "*".

Digite display: The DIGITE has a 24-character display. The type of display, e.g. station number plus name or name only is defined by means of AMO ZAND, TYPE=ALLDATA, DISPMODE-MODE1 to MODE5 (see examples). There is no verification of the last name. The number of blanks between the station number and the name is exactly one. Examples Input: Dr. v. Ritter*Martin Display MODE1: 32857 DR. V. RITTER M. MODE2: 32857 MODE3: DR. V. RITTER MARTIN MODE4: DR. V. RITTER MODE5: # DR. V. RITTER b) Organizational unit Each name can be assigned an organizational unit (for ETD functions). If a station number has not been assigned a name, no org. unit can be assigned. If station number has been assigned several names, but not everyone of these names has been assigned an organizational unit, the organizational unit which was assigned last is automatically assigned to the remaining names. Personal identification number (PIN) The PIN is used for personal identification of a person to the system. Each station number can be assigned any number of PINs. The length of a particular PIN type is determined centrally. The PIN length may or may not be the same for the types of PINs described above. Each PIN (except COSXCD) must be unique throughout the system.

c)

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

83

Siemens

AMOs

The "class of PIN" (COPIN) is used for each PIN type in order to implement the PIN display feature and in order to distinguish between the different PIN types. The characteristics of the COPINs (1 through 15) are summarized in the so-called COPIN table in which the following default values are assigned to the type of PIN:

PINTYPE PIN (COPIN) 1 = PIN1 2 = PIN2 3 4 5 6 7 8 9 10 11 12 13 14 15

COTYPE

PIN Meaning of a type of PIN

MOBILE Manual identification BUSLONG Identification of business calls (remains active until manual deletion or timeout). = PIN3 BUSSHRT Identification of business calls = PIN4 PRIVSHRT Identification of private calls = PIN5 PCODE Identification of a project for a call (project code = PCODE). = PINC PINCARD Identification by means of a magnetic/chip card which is inserted into the card reader of the terminal. = COSXCD COSXCD Identification of users which are authorized to activate COS changeover from the terminal. = SI SI Pin for service id = CDRAC PCODE CDR account code = PIN10 PCODE PIN for dialing pattern check = PIN11 MOBILE Manual identification = PIN12 MOBILE Manual identification = PIN13 MOBILE Manual identification = PIN14 MOBILE Manual identification = PIN15 MOBILE Manual identification

Function: ADD-PERSI: CHANGE-PERSI: DELETE-PERSI: DISPLAY-PERSI: REGENERATE-PERSI

84

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

18

LRNGZ - List of Central Speed Dialing Numbers

The central speed dialing facility (SPDC) is used to simplify dialing. Long call numbers (destination numbers) - usually external numbers - can be transmitted by means of a speed dialing number. The allocation of speed dialing numbers to destination numbers is stored in the central speed dialing lists. Up to 16 of these lists (0 to 15) can be set up, each with a maximum of 1000 speed dialing numbers. Each user can access up to 2 of these lists, which are allocated to him with parameters SPDC1 (List 1) and SPDC2 (LIST 2) of a subscriber AMO (e.g. AMO SCSU or SBCSU). The AMO LRNGZ is used to set up the lists and to allocate speed dialing numbers to each of them. The allocation of destination numbers is carried out using AMO ZRNGZ. The SPDC feature is accessed by dialing a code following the speed dialing number. There are two versions of access. a) Access of both lists via only one dialing code (digit analysis result SPDC1 in AMO WABE). In this case the speed dialing numbers of the lists, allocated to the user (parameter SPDC1 and SPDC2 of the subscriber AMO) must be different, since it is the speed dialing number which determines whether the 1st or 2nd list is dialed. The administrator of the switch has to take care of the so called unambiguousness of the speed dialing number ranges. Because of the various combinations of speed dialing lists, allocated to the users (any two lists out of the available lists 0 to 15 can be allocated to any user), AMO LRNGZ is not able to check the unambiguousness. In the case of 3 digit speed dialing numbers a user can access a maximum speed dialing number range of 000 to 999, divided over the two allocated lists. Therefore with this version of access a user has access to maximum 1000 speed dialing numbers. b) Access of both lists via 2 dialing codes (digit analysis results SPDC1 and SPDC2 in AMO WABE). Via dialing code of digit analysis result SPDC1, the user has access to the 1st list, allocated to the user (parameter SPDC1 of the subscriber AMO) and via dialing code of SPDC2 to the 2nd list (parameter SPDC2 of the subscriber AMO) In this case the speed dialing numbers of the lists, allocated to the user can be the same, i.e. the speed dialing number ranges can overlap, since the Lists are accessed via the dialing code (digit analysis results SPDC1 and SPDC2 in AMO WABE) and not via the speed dialing number.

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

85

Siemens

AMOs

In the case of 3 digit speed dialing numbers a user can access a maximum speed dialing number range of 000 to 999 per list. Therefore with this version of access a user has access to maximum 2000 speed dialing numbers. The AMO DIMSU is used to establish how many lists (parameter SPDCL) and destinations (parameter SPDCD) can be set up in the system.

Function: ADD-LRNGZ: CHANGE-LRNGZ: DELETE-LRNGZ: DISPLAY-LRNGZ: REGENERATE-LRNGZ

86

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

AMOs

Siemens

19

ZRNGZ - Central Speed Calling Digit Series

The central automatic dialer is a memory area of abbreviated numbers which is distributed among several lists. All system subscribers can access a maximum of two lists each.The speed dialing lists are created by AMO LRNGZ. An abbreviated number is used to simplify dialing. Each abbreviated number can be assigned an unabbreviated number. The number of suffix dialing digits describes the number of digits in the unabbreviated number which are to be transmitted with a time lag during automatic suffix dialing. DISPLAY-ZRNGZ:TYPE=SPDNO,LST=00,SPDNO=00&&49; Output:

LST: 00 KRN LRN 00 02 03

KRN-BEREICH:

00 BIS NAWA

49 NAME

00897221 ............1 .......SIEMENS MUENCHEN 003432564738 ... ..0 .......SPANIEN

0613111515 ..... ....0 .......KINODIENST MAINZ

Functions

ADD DELETE DISPLAY REGENERATE

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

87

Siemens

AMOs

88

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

Abbreviation

Siemens

Abbreviation
This table shows some important abbreviations. Abbreviation A ADP AMC AMO API C CC CMI COS D DBAR DEE DSCXL DSS E EDSS1 I ISDN Definition

Administration Daten Processor Administration and maintenance control Administration and maintenance Organization Application Interface

Common Control; Cordless Multicell Integration Class of Service;

Data Base Access Routine / Datenbasis Zugriffsroutine Data Terminal Equipment / Datenendeinrichtung Data and Switch Processor for CompactPCI/LAN Digital Subscriber Signalling 1

European Digital Signalling System No1 (Europ. D-Kanal Protokol)

Integrated System Design Network/ Diensteintegrierendes digitales Nachrichtennetz

L LDU M MMI O OS Q QSIG

Logical Device Unit

Man Machine Interface (Mensch Maschine Schnittstelle)

Operating System / Betriebssystem

ECMA-Standard fr die Signalisierung am Q-Referenzpunkt;

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

89

Siemens

Abbreviation

S SIP SWU V VINET

Session Initiation Protocol Switching Unit (or new Common Control CC)

Virtual Networking

90

EN4401EN00EN_0014
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved. Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG

S-ar putea să vă placă și