RECONSTRUCTION SYSTEM
RECONSTRUCTION SYSTEM
Optimized patello-femoral and tibio-femoral contact areas signicantly reduce contact stresses, to promote implant longevity.
RECONSTRUCTION SYSTEM
A Morse tapered bolt ensures insert xation while limiting backside wear potential.
RECONSTRUCTION SYSTEM
Minimum Resection.
Posterior stabilized knees are a mainstay in total knee arthroplasty. Substituting the PCL with a cam and post mechanism allows the knee replacement to go into deep flexion with added stability. The downside to this mechanism is the additional bone resection typically required to implant these devices. The APEX PS Knee utilizes a cylindrical resection, following the natural shape of the intercondylar fossa, preserving useful bone stock. This unique resection also allows the femoral component to have an elongated patella track, increasing range of motion in flexion.
Maximum Stability.
The APEX PS Knee utilizes the same anatomic features as the APEX CR Knee, adding a cam/post mechanism for additional stability. The cam and post are not engaged during normal gait, and rounded to avoid point contact. In flexion, the rounded cam is designed to roll down the post, and the posterior condyles maintain consistent contact with the tibial insert.
RECONSTRUCTION SYSTEM
Designed to Fit.
Some products are designed with females in mind, or gender specific. The APEX Knee System was specifically designed to fit the entire population. Before the sizing range was created, anthropomorphic studies were held with a goal to determine the overall A/P and M/L dimensions of a wide range of patients. From the results, OMNIlife science design team was able build the sizing to best fit the data. An important discovery from this data was the smaller M/L to A/P proportions in not only the female statistics, but also in select male data as well. To address this difference, APEX Plus sizes were created. These Plus sizes utilize the same box cut geometry as their larger counterparts, while incorporating a reduced flange profile and narrower M/L dimensions. This intuitive design allows the surgeon to eliminate overhang and downsize the component without having to re-cut the femur.
Reduced M/L
APEX PS KNEE
APEX CR KNEE
Reorder No. KL-014 Rev. 12/11 Copyright 2011. OMNIlife science, Inc. All rights reserved. OMNIlife science, APEX Knee and A.R.T. are trademarks of OMNIlife science, Inc. OMNIlife science Inc 50 OConnell Way Suite #10 East Taunton, MA 02718 North America: International: Tel 800-448-OMNI (6664) Fax 508-822-6030 Tel +1 508-824-2444 Fax +1 508-822-6030 www.omnils.com