Sunteți pe pagina 1din 71

Distribution Products

Distribution Products Contents Page

About Distribution Products


Broadband transmission products consist of all the products necessary to transport an RF signal, generated by a cable TV headend, through to the subscriber's drop line. This includes equipment such as trunk amplifiers, multi-taps and line passives, distribution amplifiers and line extenders. From this section, equipment product lists can quickly and easily be generated. Telewire Supply stocks products from such quality manufacturers to the cable TV industry as Power Guard, Regal Technologies, Scientific-Atlanta and many more. Equipment is regionally warehoused across the country, providing for complete system fulfillments and on-time delivery. This section is devised as a buyer's guide only and is not intended to be a design or installation guide.

Quality Policy
Telewire Supply is dedicated to meeting the requirements of our customers by providing Quality Products and Services on a timely basis.

In this section
Item . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page SA Trunk Stations . . . . . . . . . . . . . . . . . . . . . . . .H3-H11 SA Line Extenders . . . . . . . . . . . . . . . . . . . . . .H12-H14 SA Line Extender II . . . . . . . . . . . . . . . . . . . . . . . . .H15 SA Distribution Amplifiers . . . . . . . . . . . . . . . .H16-H19 SA System Amplifiers II+ . . . . . . . . . . . . . . . . .H20-H23 SA System Amplifier II+ Ordering Information . . . .H23 SA Distribution Accessories . . . . . . . . . . . . . . .H24-H28 Power Guard Power Supplies . . . . . . . . . . . . .H29-H32 Regal Taps & Passives . . . . . . . . . . . . . . . . .H35-H59 Regal 750 MHz Taps & Passives . . . . . . . .H37-H41 Regal Line Equalizers . . . . . . . . . . . . . . . . . . . . .H42 Regal 1 GHz Narrow Body Taps . . . . . . . .H43-H48 Regal 1 GHz Wide Body Taps . . . . . . . . . .H49-H52 Regal 1 GHz Passives . . . . . . . . . . . . . . . .H53-H56 Regal Tap & Passives Ordering Guide . . .H57-H59 CPB Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . .H60 SA In Line Equalizers . . . . . . . . . . . . . . . . . . . . . . .H60 SA Taps & Passives . . . . . . . . . . . . . . . . . . . . .H61-H62 MDU Distribution Amplifiers . . . . . . . . . . . . . . .H63-H70

Power Supply Batteries . . . . . . . . . . . . . . . . . . . . . .H33 Power Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H34

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H1

1996 TELEWIRE SUPPLY

Distribution Products Distribution Equipment

Definitions of Specifications
Frequency Response Maximum peak to peak variation measured between any two points in the operational bandwidth at a given location in the CATV plant. The maximum allowable peak to valley variation is N/10 + 1 dB - tilt. Measured with diplex filters, a 1 dB attenuator to simulate a valued equalizer insertion loss, and an interstage pad 1S board with jumper. Minimum Full Gain Minimum input to output station gain with automatic control module set to highest output. Minimum full gain is measured with diplex filters, a 1 dB attenuator to simulate a valued equalizer insertion loss, and an interstage pad 1S board with jumper. Typical Operating Gain Minimum input to output station gain allowing for the proper reserve gain for the automatic control module or thermal network where appropriate. Typical operating gain is measured in same test configuration as minimum full gain. Automatic Slope and Gain Equivalent cable variation at the upper frequency. Slope is the amount of cable equalization provided in the amplifier. The slope is specified as the difference in gain between the highest and lowest frequencies. Internal Station Tilt Slope of the amplifier station. Noise Figure Measured for both the highest and lowest channels at operation gain with diplex filters, a 1 dB attenuator to simulate a valued equalizer insertion loss, and an interstage pad 1S board with jumper. Additional Information can be found in Section L - Glossary Hum Modulation Hum and low frequency distortions are "undesirable signal modulations" related to power line or the video vertical sync frequencies. This is caused by variations in the visual carrier amplitude at power line frequency or its harmonic. Hum modulation is measured at maximum current passing. Cross Modulation A form of distortion when the modulated video components or any video carrier of any other channel will cross modulate or couple to the video carrier of any other channel in the operational bandwidth. This appears as undesirable beats in another carrier. Measured at stated reference levels using NCTA standard methods with synchronous square wave modulation. Composite Triple Beat Composite third order distortion is the amplitude distortion of desired signals caused by third order curvature of non-linear transfer characteristics in system equipment. CTB is the ratio expressed in dB of the peak level of the RF signal to the peak of the average level of the cluster of distortion components centered around the carrier. CTB is measured with CW carriers, carrier to average CTB, unmodulated carriers on any channel. Composite Second Order Composite second order distortion is the amplitude distortion of a desired signal caused by the second order curvature of the non-linear transfer characteristic occurring in the CATV system equipment. It is the ratio, expressed in dB, of the peak level of the desired RF signal to the peak of the cluster of distortion components falling in the sideband of the desired signal at .75 and 1.25 MHz around the carrier.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H2

Distribution Products Trunk Amplifiers

Trunk Stations SCIENTIFIC-ATLANTA


Electrical features Switching regulated power supply with automatic transient protection, overvoltage protection and current limiting circuitry for reliable operation. Plug-in hybrids and gain blocks provide for easy maintenance Built-in -20 dB input and output directional coupler test points for more accurate set-up and monitoring. Plug-in interstage trim networks permit simple system frequency response error correction without affecting basic module alignment. Switch-selectable thermal or carrier-controlled (ACM) slope and gain for maximum system stability. Surge filters for maximum protection from system surges. Mechanical features All trunk housings compatible with push-pull, parallel hybrid, feed forward or FT electronics. No motherboard - all control and functional components located within the plug-in modules - simplifying upgrade or maintenance and allowing for better heat transfer. 360 aluminum die-cast housing is 100% leak tested to ensure trouble-free operation. Positive cable seizures optimize return loss and do not damage cable center conductors or connector pins. Housing reversible for tandem mounting and convenient street-side access. Size and fin design allows for optimal heat dissipation. Amplifier technologies utilized by Scientific-Atlanta include the following:
Push-pull Parallel hybrid AT PT Feed forward FT Significantly reduces second order distortion Two push-pull stages combined for 3 dB higher levels (level addition) High performance parallel hybrid (2 dB improved distortion performance over parallel hybrid) High performance parallel hybrid (3 dB improved distortion performance over parallel hybrid) Two push-pull stages, delayed for distortion cancellation (no level addition) Feed forward gain block with parallel hybrid pre-amp

Description Scientific-Atlanta offers a complete line of 550 and 750 MHz trunk stations in either push-pull, parallel hybrid (AT), feed forward, or distortion improved FT configurations. Dual pilot ACMs, status monitoring and reverse can be easily added to any station by use of plug-in modules. Fully loaded feed forward module upgrades are possible in any Scientific-Atlanta housing existing in the field. A plug-in automatic control module augments a built-in thermal slope and gain compensator. Status monitoring/reverse switching and reverse options are compatible with forward modules allowing future upgrades without obsoleting existing equipment. Diplex filters plug in, as do the stepped pads, equalizers and other accessories. Trunk and bridger module technologies can be mixed and matched for optimal system performance. An accurate switch selectable built-in thermal slope and gain compensating network provides a continuous balance temperature reference for pad and equalizer selection. Plug-in interstage trim networks facilitate selective adjustment of the system frequency response without altering the basic amplifier module alignment.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H3

1996 TELEWIRE SUPPLY

Distribution Products Trunk Amplifiers

Trunk / Bridger Station Ordering Matrix SCIENTIFIC-ATLANTA 1

(DIGIT) COATING 1. 2. #373166 uncoated housing #372226 coated housing

(DIGIT) STATUS MONITOR 0. 1. 2. none #371146 109 MHz #372203 301.25 MHz (NSP*) specify #370760 107.5 MHz #376362 107.7 MHz

(DIGIT) FILTERS 1. 3. 4. 6. 7. #373177 surge filter fwd. only (std.) #375120 sub-split 46-550 MHz (1) #370292 mid-split 5-112/150-550 (1) #372276 high-split 5-186/222-550 MHz (1) #379944 int'l split 50-70 MHz (1)

3. 4. 5.

(DIGIT) AUTO CONTROL (3) 0. 1. None (order 1 LPA 035919) #343980 specify pilots

(DIGIT) VOLTAGE 0. #279660 60 VAC power supply (DIGIT) REVERSE (4) 0. (DIGIT) TRUNK AMPLIFIER (2) 3. F. 550 MHz 22 dB push-pull 344070 550 MHz 27 dB FF 347099 1. 7. none sub-split trunk 372741 (5) sub-, mid-, high-split trunk 234600 (7)

G. 550 MHz 30 dB FF 343920 L. 550 MHz 26 dB "FT" 376494

(DIGIT) BRIDGER (2) (3) (6) 0. none (order 1 LPA 035919) B. 550 MHz 32 dB std. PHD 370660 C. 550 MHz 32 dB "FT" 499937 D. 550 MHz 21 dB FF 499938 E. 550 MHz 26 dB PHD 381128 F. 550 MHz 32 dB dual PHD 30/46 381134

M. 550 MHz 22 dB "PHD" 462441 N. 550 MHz variable FITT, 30/468 466289 P. 750 MHz FITT/ Bridger, 30/468 502567

G. 550 MHz 32 dB dual PHD 50/70 463405 H. 550 MHz 25 dB dual PHD 30/468 500303

(1) (2) (3) (4)

2 filters per trunk amp; 1 per bridger - order separately. All trunk and bridgers require 1 pad (specify dB) and 1 forward EQ(specify MHz and dB); all bridgers require (1) BFM (bridger feedermaker). No LPA is required for ACM or bridger when ordering 344030 int/term trunks. If using reverse, high pass filters required as follows: 1 per trunk; 1 per bridger. Exception: if using 373185 or 376043 interstage EQ, these already have high pass filters built in them. Diplex filters must also be ordered and noted in the second block of this matrix. Also required for most reverse amps are: 1 reverse EQ and 1 pad. Requires (1) 234502 low pass filter; 2 pads and 1 reverse EQ.

(6)

Requires (1) 370305 high pass filter if used in mid-split operation or (1) 372286 high pass filter if used in high split operation. No high pass filter required for sub-split operation. Must include (1) thermal gain driver and (1) thermal slope driver; specify dB (1) high pass filter required; also requires 2 pads and 1 reverse EQ, low pass filter (1) 2 filters per trunk amp; 1 per bridger - order separately.
8

(7)

(8)

(5)

Dual PHD Bridgers (P/N 381134, 463405, 500303), Variable FITT (P/N 466289) and FITT/Bridger (P/N 502567) come with diplex filters installed. One plug-in passive is required for Variable FITT and FITT/Bridger, depending on configuration. Use jumper, if being used in terminating mode. Use two-way splitter, DC-8 or DC-12 in intermediate mode.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H4

Distribution Products Trunk Amplifiers

Trunk Amplifier Configurations SCIENTIFIC-ATLANTA


Choose components from the options . . . . list in the following column: Manual trunk station Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #1 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . #2 Forward trunk module. . . . . . . . . . . . . . . . . . . . #3 Automatic trunk station Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #1 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . #2 Forward trunk station . . . . . . . . . . . . . . . . . . . . #3 Automatic gain control . . . . . . . . . . . . . . . . . . . #4 Intermediate bridging amplifier Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #1 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . #2 Intermediate/terminating trunk amp module . . #5 Bridger amplifier . . . . . . . . . . . . . . . . . . . . . . . . #6 Manual trunk with bridging amplifier Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #1 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . #2 Forward trunk amplifier . . . . . . . . . . . . . . . . . . . #3 Bridger amplifier . . . . . . . . . . . . . . . . . . . . . . . . #6 Automatic trunk with bridging amplifier Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #1 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . #2 Forward trunk amplifier . . . . . . . . . . . . . . . . . . . #3 Automatic gain control . . . . . . . . . . . . . . . . . . . #4 Bridger amplifier . . . . . . . . . . . . . . . . . . . . . . . . #6 Ordering Information - #1 Housings Order No.
SCI 204153 SCI 122473

Mfg. No.
373166 372226

Description
uncoated coated

#2 Power Supply Order No.


SCI 039782

Mfg. No.
279660

Description
60VAC power

#3 Forward trunk modules Order No.


550 MHz SCI 117114 SCI 204300 SCI 147921

Mfg. No.
344070 347099 462441

Description
22 dB push-pull 27 dB FF 22 dB "AT"

#4 - Automatic gain control (AGC) specify high & low pilots* Order No.
SCI 049500 SCI 119551 SCI 119552 SCI 040774 SCI 147180

Mfg. No.
343980 343980 343980 343980 343980

Description
Ch. 3/N Ch. 3/W Ch. 3/12 Ch. 4/11 Ch. 3/NN

#5 - Intermediate / terminating trunk module Order No.


SCI 144951 SCI 204368

Mfg. No.
466289 502567

Description
variable 550 MHz 30/46 750 MHz 30/46

For reverse sub-split operation, add: Order No.


SCI 045347 SCI 049004 Various Various * dB value

Mfg. No.
372741 DFS30 EQ30T PP-*

Description
reverse amplifier diplex filters reverse equalizer plug-in pad

#6 - Bridger amplifier module Order No.


550 MHz SCI 117130 SCI 204367

Mfg. No.
370660 500303

Description
32 dB std. PHD 25 dB dual PHD

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H5

1996 TELEWIRE SUPPLY

Distribution Products Trunk Amplifiers

Power Supply Module for Trunk SCIENTIFIC-ATLANTA

Trunk Amplifier Housings SCIENTIFIC-ATLANTA

Features Switching regulated supply for high efficiency and reduced power bills Transistorized overvoltage protection circuit - high voltage transients of greater than 35 milliseconds blow the power supply fuse Short circuit protection - DC shorts activate current limiting circuits which prevent component damage Efficient thermal design utilizing direct module heat sink contact with housing Total access for ease of maintenance in the field Local/remote operation - switch selectable transformer taps to provide improved efficiency at lower AC voltage points Description The model 279660 switching regulated power supply module is used in all Scientific-Atlanta trunk stations to convert station AC input to a well-regulated DC voltage for station powering. The switching regulated power supply automatically adjusts its internal operating parameters for most efficient use of different levels of voltage and current within a system. It automatically determines load power requirements and adjusts its operation so that only that amount of power is provided. The module has advanced switching regulator design, false trigger immune overvoltage protection, current limit, efficient thermal design and total access for ease of maintenance in the field. Specifications - with 280182 FFD X-former
Recommended in voltage range Output voltage (factory set) Maximum output current Line regulation Efficiency Hum Overvoltage time delay Operating temperature 40 VAC - 80 VAC square wave 24 VDC 0.5 V 3.0 A 1% 80% 10 mV P-P 35 ms approx. -40F to +140F

Features Compatible with push-pull, parallel hybrid, feed forward or FT electronics No motherboard - all control and functional components located within the plug-in modules 360 aluminum die-cast 100% leak tested Positive cable seizures optimize return loss and do not damage cable center conductors or connector pins Optional protective paint coating with stainless steel hardware Reversible for tandem mounting and convenient street-side access Size and fin design allows for optimal heat dissipation Ordering Information Order No.
SCI 204153 SCI 122473

Mfg. No.
373166 372226

Ordering Information Order No.


SCI 039782

Mfg. No.
279660
800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

1996 TELEWIRE SUPPLY

H6

Distribution Products Trunk Amplifiers

550 MHz Trunk Amplifier SCIENTIFIC-ATLANTA


Ordering Information Order No.
SCI 117114

Mfg. No.
344070 347099 462441

Amplifier Type
PP FF AT

Gain
22 27 22

Features Plug-in hybrids including the feed forward post-amp minimize module distortions while providing for easy maintenance Built-in -20 dB input and output directional coupler test points for more accurate set-up and monitoring 10.5 sq. inches of direct module contact to the housing for superior amplifier heat sinking Plug-in accessories to protect the system set-up integrity Plug-in interstage trim networks to permit simple system frequency response error correction without affecting basic module alignment Switch-selectable thermal or carrier-controlled (ACM) slope and gain for maximum system stability AC power directors for power pass or block from input or output Description 550 MHz trunk amplifier modules are available in 22 dB pushpull, 27 and 30 dB feed forward, and 26 dB feed forward FT technologies. The AT trunk amplifier module utilizes an advanced version of parallel hybrid technology to offer significantly improved performance over conventional parallel hybrid. The FT trunk amplifier module improves system performance by utilizing a parallel hybrid pre-amp. The 550 MHz FT trunk module can often be used in 330 MHz to 550 MHz upgrades without respacing trunks.

SCI 204300 SCI 147921

Specifications on the following page.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H7

1996 TELEWIRE SUPPLY

Distribution Products Trunk Amplifiers

550 MHz Trunk Amplifier Module Specifications SCIENTIFIC-ATLANTA

Required plug-in components: Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required

All specifications reflect typical performance at stated reference levels; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt).

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H8

Distribution Products Trunk Amplifiers

550 / 750 MHz Variable Forward Intermediate / Terminating Trunk Modules SCIENTIFIC-ATLANTA

Specifications

Features Plug-in passive to divide the signal between through trunk leg and input to bridger Built-in -20 dB directional coupler test points for more accurate set-up and monitoring Plug-in thermal network for temperature compensation Built-in diplex filter for surge protection and two-way operation Plug-in signal directors to allow signal flow from left-toright or right-to-left AC power directors for power pass or block from input or output Through current capability of 12 Amps in the main intermediate path Description The variable intermediate/terminating trunk module is used in the forward system to provide feeder locations between trunk or distribution amplifier stations or to terminate the trunk system where existing trunk requirements end. In the intermediate configuration, the trunk signal is passed through the module (without amplification) and is tapped off, equalized, amplified and routed to a bridger module. In the terminating configuration, the input signal is equalized, amplified and routed to a bridger module. The module is configured for intermediate or terminating operation by means of a plug-in passive device. The module is variable, meaning a plug-in passive can be plugged into the module, allowing the user to select a splitter, 8 dB or 12 dB coupler in the intermediate mode. A plug-in jumper is selected to place the module in terminating mode. This module is reversible, allowing signal directors to be positioned such that the station RF direction can be either left-to-right or right-to-left.

Required plug-in components Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required Plug-in passives - one required All specifications reflect typical station performance numbers; cascade improvement not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt). Bridger module not included in specifications. (F) Specifications shown with no plug-in passive (G) Typical trunk through loss is specified in the following chart, at the following frequencies (H) For bridger path loss, use plug-in passive chart loss only. 5 MHz: 0.77; 30 MHz: 0.;42; 50MHz:0.45;300MHz:0.95;330 MHz: 0.99; 400 MHz: 1.09; 450 MHz: 1.19; 550 MHz: 1.61

Ordering Information Order No.


SCI 144951 SCI 204368

Mfg. No.
466289 502567

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H9

1996 TELEWIRE SUPPLY

Distribution Products Trunk Amplifiers

550 MHz Bridging Amplifier Module Specifications SCIENTIFIC-ATLANTA

Required plug-in components: Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required Plug-in feedermaker (specify type) - one required

All specifications reflect typical performance at stated reference levels; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt). (E) Flatness through bridger module only.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H10

Distribution Products Trunk Amplifiers

Reverse Amplifier Modules SCIENTIFIC-ATLANTA

Specifications

Features Built-in 20 dB input and output directional coupler test points for more accurate set-up and monitoring Plug-in accessories to protect system set-up integrity 10.5 sq. inches of direct module contact to the housing for superior amplifier heat sinking Plug-in trim networks to permit simple system frequency res-ponse error correction without affecting basic module alignment Two types of high isolation plug-in switches can be installed in either the trunk or feeder input and operated from a reverse disconnect system Plug-in combiner or jumper allows increased gain when only feeder or only trunk is activated Description Models 372741 and 466545 serve as the primary amplifiers for reverse trunk stations. Model 372741 provides 14 dB of gain and utilizes transistor technology; model 466545 provides 20 dB of gain and utilizes hybrid technology. The reverse amplifier module installs in the bottom of a standard trunk housing next to the power supply and provides gain for reverse trunk transportation and origination of feeder signals. Plug-in drivers allow for thermal slope and gain compensation of various lengths of cable. The single reverse amplifier with thermal compensation functions both as a transportation amplifier where trunk-only or both trunk and feeder may be activated or as a terminating amplifier where feeder-only is required. In a terminating station where trunk is not activated or in a transportation station where feeder is not activated, gain can be increased by removing the plug-in combiner and installing a jumper module including combiner as standard equipment. The amplifier is designed to be compatible with computer-operated reverse disconnect systems. Ordering Information Order No.
SCI 045347

All specifications reflect typical performance at stated reference levels; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt). (D.) See thermal compensation drivers. Required plug-in components: Plug-in pad for trunk path (PP-*) - one required Plug-in pad for feeder path (PP-*) - one required Plug-in reverse equalizer (specify value) - one required

Mfg. No.
372741

Description
sub-split (5-50 MHz)

Plug-in low pass filter (specify split) - one required Thermal slope and gain drivers - one each required

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H11

1996 TELEWIRE SUPPLY

Distribution Products Line Extenders

Line Extenders SCIENTIFIC-ATLANTA

Description Scientific-Atlanta line extender amplifiers are engineered for the same high reliability as the trunk amplifiers. They are designed to facilitate speed, accuracy and ease of set-up. Both forward and reverse amplifiers utilize plug-in field replaceable, state-of-the-art hybrid circuitry. Upgrading for two-way operation requires the insertion of a plug-in pad, equalizer, hybrid amplifier and diplexing filters. Thermal compensation option is available to compensate for changes in gain and slope due to ambient temperature swings. The housing and the line extender module are symmetrical, which enables the housing to be mounted in the direction most convenient for maintenance. Also available with a protective paint coating with stainless steel hardware for operation in the harshest environments.

Features Plug-in hybrids provide for easy maintenance Built-in -20 dB input and output directional coupler test point for more accurate set-up and monitoring Direct module plug-in to the housing for superior amplifier heat sinking Plug-in accessories for ease of system set-up Symmetrical module and housing permit mounting for most convenient maintenance Surge filter for maximum hybrid protection from system surges Plug-in transient protectors Connector selectable transformer taps and built-in voltage indicator Power supply overvoltage protection Input and output transient protection Cable seizures provide positive connection and ensure good return loss LED indicator on power supply

Ordering Information - Line Extender Housings Order No.


SCI 039779 SCI 123756

Mfg. No.
232700 370576

Description
uncoated housing coated housing

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H12

Distribution Products Line Extenders

550 MHz LE II Line Extender Modules SCIENTIFIC-ATLANTA

Specifications

Features Compatible with all existing line extender housings Housing and module are symmetric, allowing housing to be mounted in either direction Power supply more efficient than standard switching regulated supplies Directional coupler forward test points User friendly module cover Surge resistant circuitry (SRC) with on board surge filters and optional AC crowbar circuitry Optional auto control module, thermal compensation network and variable interstage equalizer Current capacity up to 12 Amperes Optional plug-in reverse amplifier and filters Description The LE II complements Scientific-Atlanta's system amp, variable FITT and trunk/bridger to meet current and future requirements. The LE II is fully backwards compatible to all S-A line extender housings, allowing flexible upgrade options at any time.

The LE II utilizes a high efficiency power supply, reducing power costs. The LE II also has the option of an auto control module, allowing longer feeder cascades and improved plant performance, regardless of the architecture being used. Ordering Information Order No.
SCI 145225 SCI 145226

All specifications include diplex filters, 1 dB for equalizer insertion loss, and 0 dB pad (normal 2-way operating configuration.) All specifications reflect typical performance numbers in manual mode; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt).

Mfg. No.
467066 467067

Amplifier Type
PHD PHD

Required plug-in components:

Gain
36 33

Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H13

1996 TELEWIRE SUPPLY

Distribution Products Line Extenders

550 MHz LE II Line Extender Module Specifications SCIENTIFIC-ATLANTA

Required plug-in components Forward Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required Reverse Sub-split 30/46 reverse kit Sub-split 50/70 reverse kit Plug-in pad - one required Plug-in equalizer - one required

All specifications reflect typical performance at stated reference levels; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt). (D) Reduction to full gain if using the following optional equipment: thermal network (378449) induces a maximum insertion loss of 5.6 dB at 550 MHz; interstage pad board (372538) induces a maximum insertion loss of 1 dB.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H14

Distribution Products Line Extenders

Line Extender II 750 MHz with 40/51 MHz Split

Ordering Information
Order No.
SCI 039779 SCI 123756

Mfg. No.
232700 370576

Description
Uncoated Housing Coated Housing

Housing - 1 Required

Amplifier Modules - 1 Required SCI 202558 SCI 201311 544906 511061 Forward Only w/No Lockout (for 60 V applications) Forward and Reverse w/No Lockout (for 60 V applications) Forward and Reverse w/40 V Lockout (for 90 V applications)

SCI 202555

544462

Required Accessories SCI 296743 542048 Single Pilot AGC w/3-9 dB Variable Interstage Equalizer Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

SCI 204565

503100

Description The Line Extender II (LE II) family of RF amplifiers complements Scientific-Atlantas System Amplifier I and II, Variable FITT, and Trunk/Bridger products. These high quality devices are available in a number of bandwidth and interstage control options to meet a variety of architecture requirements. Twoway versions of the LE II are also available to support the advanced networks currently being deployed. Features 60 and 90 Vac powering capability Unitized design (amplifier and power supply in a single module) enables simplified and faster maintenance Available with integrated reverse amplifier for two-way applications High efficiency, transformer-less power supply lowers system operating costs Fixed value plug-in accessories (common with all System Amplifier II and Line Extender II) simplify maintenance and reduce inventory requirements Surge Resistant Circuitry ? ensures hybrid protection without fuses or other nuisance failure causing devices Utilizes a standard Scientific-Atlanta line extender housing: - single tool (1/2-inch hex head) installation and maintenance - composite RFI/weather gasket - symmetric to enable mounting in either direction

SCI 204390

511380

Optional Accessories SCI 204542 467351 230 Vac Crowbar Surge Protector Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Related Equipment SCI 040028 SCI 204547 SCI 292429 SCI 294877 143351 501111 500477 538643 230 Vac Cable Seizure Wrench Long Reach Test Point Adapter Reverse Test Point Adapter Reverse Injection Filter, 5-40/51-750 MHz

Required Accessories Plug-in Pads, 2 required (1 input, 1 output), 1 additional pad required for reverse, and 1 addition pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (*denotes equalizer value), specify value. Reverse Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB. Model EQ40T-* (*denotes equalizer value), specify value. One of the following interstage Accessories is required for most applications: (Ordering Information for above on Pages H24 - H27)

Specifications and product availability are subject to change without notice. Surge Resistant Circuitry is a trademark of Scientific-Atlanta, Inc.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H15

1996 TELEWIRE SUPPLY

Distribution Products Distribution Amplifiers

Distribution Amplifiers SCIENTIFIC-ATLANTA


Electrical features Plug-in hybrids provide for easy maintenance Built-in 20 dB input and output directional coupler test points for more accurate set-up and monitoring Optional plug-in automatic slope and gain control module for use in fiber to the serving area or trunk applications Plug-in DC powered thermal network Plug-in accessories for ease of system set-up High efficiency transformerless switching regulated power supply or standard switching regulated power supply Optional reverse amplifier Plug-in transient protectors Mechanical features Two and four-port outdoor housings Two-port indoor housing Plug-in passives reduce the number of external splices Bandwidth operation up to 600 MHz Selectable transformer taps and built-in voltage indicator AC fused or circuit breaker input port Power passing or blocking jumpers on output ports

Description The distribution amplifier provides a variety of configurations for both trunk and feeder applications. When auto control is used, this station is ideal for fiber to the serving area applications, tapped trunk systems, local area networks, improving feeder stability, or as a cost effective substitute for the terminating bridger. The distribution amplifier is available with push-pull, standard parallel hybrid, PT parallel hybrid, standard feed forward and FT feed forward technologies. The station may be set for manual, thermal regulation or automatic slope/gain control. Housings are available in either two or four port configurations. The four port housing allows level and signal routing through plugin passive devices, mounted on the seizure boards. This reduces the need for connecting external passive devices which lowers the chance for signal leakage and cable pull-out problems. AC bypass and lightning filtering are accomplished on separate seizure boards mounted within the housing. Power passing and blocking are external to the amplifier module so that power is passed through the housing even in the absence of the amplifier module.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H16

Distribution Products Distribution Amplifiers

Distribution Amplifier Ordering Matrix SCIENTIFIC-ATLANTA

(DIGIT) COATING 31. #344802 2-port housing uncoated 32. #372206 2-port housing coated 41. #372315 4-port housing uncoated 42. #372316 4-port housing coated 50. #380902 2-port indoor housing (DIGIT) FILTERS - (qty 2) 0. 1. 3. 4. 6. 7. jumpers, forward only #374702 surge filter forward only #375128 sub-split 5-30/46-550 MHz #372480 mid-split 5-112/150-550 MHz #372281 high-split 5-186/222-550 MHz #379947 int'l split 5-50/70-600 MHz

(DIGIT) STATUS MONITOR 0. none

(DIGIT) AUTO CONTROL 0. 3. none #276660 auto control (specify high pilot)

(DIGIT) REVERSE (1) 0. none A. #376740 5-30 MHz discrete reverse for PP, PHD, PT (field installed kit) B. #372505 5-30 MHz discrete reverse for FF and FT (field installed kit) C. #463101 5-50 MHz hybrid reverse

(DIGIT) VOLTAGE 0. 2. 3. #276715 60 VAC power supply #115 VAC indoor application #463329 60 VAC high efficiency power supply (DIGIT) BRIDGER 0. none

(DIGIT) DISTRIBUTION AMPLIFIER 2. 8. 9. #344440 550 MHz 33 dB push-pull #370683 550 MHz 33 dB std. PHD #370697 550 MHz 37 dB std. PHD

C. #499966 550 MHz 37 dB feed forward

D. #3463402 600 MHz 36.5 dB std. PHD

(1) Reverse kits (items A, B and C) are field installed. All other reverse amps should be ordered in conjunction with a "0" in the distribution amplifier slot. (2) Jumpers (372340) and passives (372352 2-way splitter, 372348 8 dB directional coupler or 372444 12 dB directional coupler) must be ordered as follows: if only one output on housing is activated - order 1 jumper; if 2 outputs are activated-order 1 jumper and 1 passive; if 3 outputs are activated - order 2 passives.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H17

1996 TELEWIRE SUPPLY

Distribution Products Distribution Amplifiers

550 MHz Distribution Amplifier Module Specifications SCIENTIFIC-ATLANTA

Required plug-in components Forward Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) -one required Plug-in passives (for four-port housing) for routing RF signal flow jumper (372340) 2-way splitter (372352), DC-8 (372348), or DC-12 (372344) Reverse Discrete sub-split reverse kit - (276740) for push-pull or parallel hybrid,(372505) for feed forward Plug-in pad (PP-*) - one required Plug-in equalizer (EQ-dB-MHz) - one required SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

All specifications reflect typical performance at stated reference levels; cascade improvements not included. All specifications referenced to 68F (20C). Cable shape: (-) for cable (down tilt), (+) for equalization (up tilt). Powering: add 0.10 amps DC for AGC. (E) Reduction to full gain if using the following optional equipment: AGC network - 6 dB; optional trim network - 2 dB; interstage pad board - 2 dB. (F) Thermal network (276645) induces a maximum insertion loss of 3.5 dB at 550 MHz, 1.5 dB at 46 MHz.

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H18

Distribution Products Distribution Amplifiers

Distribution Amplifier Power Supply Module SCIENTIFIC-ATLANTA

Distribution Amplifier Automatic Control Module SCIENTIFIC-ATLANTA

Description The distribution amplifier power supply module is used in the distribution amplifier station to convert station AC input voltage to a well-regulated DC voltage for station powering. The switching regulated supply provides improved efficiency over a standard linear power supply which results in cost savings in operating expense. The switching regulated supply is a constant power device, meaning that it automatically adjusts its internal operating parameters for most efficient use of different levels of voltage and current within a system. The supply automatically determines load power requirements and adjusts its operation so that only that amount of power is provided. Specifications
Output voltage AC input voltage Output current Output ripple Switching frequency (1) 24 VDC 1V 60V to 37V min, 60V system typical 1.2A max. 10 mV peak-to-peak, max. 5 kHz to 20 kHz 20 ms, min. 60% to 70% 1.5 A

Description The distribution amplifier automatic control module is used in the forward system to provide carrier level control of the slope and gain circuits in the distribution amplifier module, and provides AGC systems up to 600 MHz. The automatic control module samples the band of signals of the distribution amplifier output, monitors a high-band carrier (high pilot), and provides error correction input to the slope and gain circuits in the event level changes occur. The closed loop system ensures a constant distribution amplifier output level despite changes in signal level prior to the station. It operates from either modulated carriers by detecting the peak carrier level during the sync interval or from unmodulated CW carriers. The automatic control module features excellent internal temperature stability, total immunity to adjacent channel level changes, total immunity to changes in modulation level or content, true peak carrier detection with either modulated or unmodulated inputs, and simple, accurate set-up. Specifications
Pilot frequency Return loss Nominal loss high pilot-standard trunk high pilots 16 dB 6 dB

Tsus (2) Efficiency over typical range Output fuse

Slope and gain, compensation range 4 dB Pilot level stability over temperature 0.25 dB Current requirements Operating temperature Weight 100 mA at 24 VDC -40F to +140F (-40C to +60C) 0.5 lb. net

Output overvoltage protection 32V threshold for SCR crowbar Operating temperature -40F to +140F (-40C to +60C)

(1) load dependent (2) minimum time that the supply can sustain stated output voltage when AC is interrupted

Ordering Information Ordering Information Order No.


SCI 079767

Mfg. No.
276715

Order No.
SCI 139363 SCI 139365 SCI 139366 SCI 139367

Mfg. No.
276660 276660 276660 276660

Pilot Channels
11 12 13 N

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H19

1996 TELEWIRE SUPPLY

Distribution Products Distribution Amplifier

System Amplifier II+ 750 MHz with 40/51 MHz Split

The High Gain Dual output module Providing two high level outputs (with the ability to split one to feed a third port), the High Gain Dual is primarily utilized in advanced Fiber to the Serving Area (FSA) architectures serving as a tap amplifier. With its extra amplification stage, the amplifier is also extremely useful in long-reach applications, and as a terminating bridger in more traditional architectures. In addition, the High Gain Duals common platform and configuration with the Model 6920 fiber node, make it the ideal device for positioning in future fiber deployment locations. Housing - 1 Required
499964 Uncoated 4-port Housing w/external test point access 499965 Coated 4-port Housing w/external test point access 500401 Coated 4-port Housing w/external test point access and side entry ports 544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid

Amplifier Modules - 1 Required for High Gain Dual


544901 Forward Only w/30 V Lockout (for 60 V applications) 539321 Forward and Reverse w/30 V Lockout (for 60 V applications)

Features 60 to 90 Vac powering capability Unitized design (amplifier and power supply in a single module) enables simplified and faster maintenance. Status monitoring capability Available with integrated reverse amplifier for two-way applications High efficiency, transformer-less power supply lowers system operating costs Reversible module increases availability during upgrading and reconfiguring Fixed value plug-in accessories (common with all System Amplifier II+ and Line Extender II) simplify maintenance and reduce inventory requirements Surge Resistant Circuitry Ensures hybrid protection without fuses or other nuisance failure causing devices Utilizes a standard, four-port housing featuring: - single tool (1/2-inch hex head) installation and maintenance - optional side-entry ports for pedestal installations - composite RFI/weather gasket Description The System Amplifier II+ family of RF amplifiers includes a variety of gain, output, and frequency configurations to optimally address the various network architectures being deployed. Whether its the Single (PHD or Quad), Dual (Low or High Gain), or Triple (Balanced or Unbalanced), each has been designed to afford maximum flexibility and upgradability to enable low cost delivery of basic broadcast video to high feature delivery of advanced video, data, and voice services. Reliability and maintainability are also at the core of the designs to ensure maximum network availability. Ordering Information on page H23
Specifications and product availability are subject to change without notice. FSA and Surge Resistant Circuitry are trademarks of Scientific-Atlanta, Inc. SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA

544458 Forward and Reverse w/40 V Lockout (for 90 V applications)

Required Accessories
Plug-in Pads, 4 required (1 input, 1 interstage, 2 output), 1 additional pad required for reverse, and 1 additional pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer, select one of the following: 511075 511295 511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

Plug-in Passive for Auxiliary Output for High Gain Dual, select one of the following: 467778 502110 502115 502120 Jumper 2-way Splitter DC-8 DC-12

One of the following Interstage Accessories is required for most applications: 542048 503100 511380 445 MHz Single Pilot AGC w/3-9 dB Variable Interstage Equalizer Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

Optional Accessories
467351 230 Vac Crowbar Surge Protector Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder 511216 Circuit Breaker, 5 amp 511217 Circuit Breaker, 8 amp

Related Equipment
501111 Long Reach Test Point Adapter

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H20

Distribution Products Distribution Amplifiers

System Amplifier II+750 MHz with 40/51 MHz Split continued


The Balanced Triple output module Providing three high level outputs, the Balanced Triple is primarily utilized in advanced Fiber to the Serving Area (FSA) architectures serving as a tap amplifier. In densely populated areas, it is a uniquely cost-effective solution.
Housing - 1 Required
499964 Uncoated 4-port Housing w/external test point access 499965 Coated 4-port Housing w/external test point access 500401 Coated 4-port Housing w/external test point access and side entry ports 544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid

The Quad Single output module As a high performance, low distortion device, it is ideally suited for supporting system upgrades of lengthy trunk runs. Housing - 1 Required
499964 Uncoated 4-port Housing w/external test point access 499965 Coated 4-port Housing w/external test point access 500401 Coated 4-port Housing w/external test point access and side entry ports 544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid

Amplifier Modules - 1 Required for Single Quad


544902 Forward Only w/30 V Lockout

Amplifier Modules - 1 Required for Balanced Triple


544903 Forward Only w/30 V Lockout (for 60 V applications) 511067 Forward and Reverse w/30 V Lockout (for 60 V applications) 544459 Forward and Reverse w/40 V Lockout (for 90 V applications)

537120 Forward and Reverse w/30 V Lockout

Required Accessories
Plug-in Pads, 2 required (1 input, 1 output), 1 additional pad required for reverse, and 1 additional pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer, select one of the following: 511075 511295 511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

Required Accessories
Plug-in Pads, 4 required (1 input, 3 output), 1 additional pad required for reverse if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer for Balanced Triple, select one of the following: 511075 511295 511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

One of the following Interstage Accessories is required for most applications: 542048 503100 511380 445 MHz Single Pilot AGC w/3-9 dB Variable Interstage Equalizer Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

One of the following Interstage Accessories is required for most applications: 503100 511380 Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

Optional Accessories
467351 230 Vac Crowbar Surge Protector Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder 511216 Circuit Breaker, 5 amp 511217 Circuit Breaker, 8 amp

Optional Accessories
467351 230 Vac Crowbar Surge Protector

Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder 511216 Circuit Breaker, 5 amp 511217 Circuit Breaker, 8 amp

Related Equipment
501111 Long Reach Test Point Adapter

Related Equipment
501111 Long Reach Test Point Adapter

Ordering Information on page H23

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H21

1996 TELEWIRE SUPPLY

Distribution Products Distribution Amplifiers

System Amplifier II+750 MHz with 40/51 MHz Split continued


The PHD Single output module It is ideally suited for express amplifier locations and for applications where status monitoring capability are required. It can also be applied in future multi-port positions enabling minimal interruption during reconfiguration.
Housing - 1 Required
499964 Uncoated 4-port Housing w/external test point access 499965 Coated 4-port Housing w/external test point access 500401 Coated 4-port Housing w/external test point access and side entry ports 544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid 499965 Coated 4-port Housing w/external test point access

The Low Gain Dual output module Providing two high level outputs (with the ability to split one to feed a third port), the Dual is primarily utilized in advanced Fiber to the Servicing Area (FSA?) architectures serving as an express or tap amplifier. It can also be deployed as a terminating bridger in more traditional architectures. In addition, the Duals common platform and configuration with the Model 6920 fiber node, make it the ideal device for positioning in future fiber deployment locations.
Housing - 1 Required
499964 Uncoated 4-port Housing w/external test point access

Amplifier Modules - 1 Required for Single PHD


544900 Forward Only w/30 V Lockout (for 60 V applications) 511058 Forward and Reverse w/30 V Lockout (for 60 V applications) 544461 Forward and Reverse w/40 V Lockout (for 90 V applications)

500401 Coated 4-port Housing w/external test point access and side entry ports 544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid

Amplifier Modules - 1 Required for Low Gain Dual


544899 Forward Only w/30 V Lockout (for 60 V applications)

Required Accessories
Plug-in Pads, 2 required (1 input, 1 output), 1 additional pad required for reverse, and 1 additional pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. - Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer, select one of the following: 511075 511295 511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

511052 Forward and Reverse w/30 V Lockout (for 60 V applications) 544457 Forward and Reverse w/40 V Lockout (for 90 V applications)

Required Accessories
Plug-in Pads, 3 required (1 input, 2 output), 1 additional pad required for reverse and 1 additional pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer, select one of the following: 511075 511295 511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

One of the following Interstage Accessories is required for most applications: 542048 503100 511380 445 MHz Single Pilot AGC w/3-9 dB Variable Interstage Equalizer Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

Reverse Combiner, 1 required for 2-way operation, order Plug-in Passive #502110. Plug-in Passive for Auxiliary Output, select one of the following: 467778 502110 502115 502120 Jumper 2-way Splitter DC-8 DC-12

Optional Accessories
467351 230 Vac Crowbar Surge Protector Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder

One of the following Interstage Accessories is required for most applications: 511216 Circuit Breaker, 5 amp 542048 511217 Circuit Breaker, 8 amp 503100 Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer 445 MHz Single Pilot AGC w/3-9 dB Variable Interstage Equalizer

Related Equipment
501111 Long Reach Test Point Adapter

511380

Optional Accessories
467351 230 Vac Crowbar Surge Protector Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder 511216 Circuit Breaker, 5 amp 511217 Circuit Breaker, 8 amp

Ordering Information on page H23

Related Equipment
501111 Long Reach Test Point Adapter SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H22

Distribution Products Distribution Amplifiers

System Amplifier II+750 MHz with 40/51 MHz Split continued


The Unbalanced Triple output module Providing one low and two high level outputs, the Unbalanced Triple is ideal for supporting trunk/bridger type locations in new build, rebuild, and upgrade architectures.
Housing - 1 Required
#499964 Uncoated 4-port Housing w/external test point access #499965 Coated 4-port Housing w/external test point access #500401 Coated 4-port Housing w/external test point access and side entry ports #544453 Coated 4-port Housing w/Low Profile Status Monitoring Lid

Ordering Information Housings Order No.


SCI 291724 SCI 201024 SCI 202482 SCI 202575

Required Accessories Mfg. No.


499964 499965 500401 544453

Order No.

Mfg. No.

Variable Reverse Equalizer SCI 201308 511075 SCI 201309 SCI 269839 511295 511298

Amplifier Modules - 1 Required for Unbalanced Triple


#544904 Forward Only w/30 V Lockout (for 60 V applications) #539327 Forward and Reverse w/30 V Lockout (for 60 V applications) #544460 Forward and Reverse w/40 V Lockout (for 90 V applications)

Plug-in Passive for Aux.

Amplifier Modules Order No.


High Gain Dual SCI 202571 SCI 296868 SCI 202566

Output SCI 147981 SCI 204562 SCI 204563 SCI 204564

467778 502110 502115 502120

Mfg. No.
544901 539321 544458

Required Accessories
Plug-in Pads, 4 required (1 input, 1 interstage, 2 output), 1 additional pad required for reverse, and 1 additional pad required for AGC if applicable. Available in 1 dB steps from 0 to 20 dB. Model PP-* (* denotes pad value), specify value. Plug-in Forward Equalizer, 1 required. Available in 1.5 dB steps from 0 to 27 dB at 750 MHz. Model EQ750-* (* denotes equalizer value), specify value. Variable Reverse Equalizer, select one of the following: #511075 #511295 #511298 1.5 to 4.5 dB 4.5 to 7.5 dB 7.5 to 12.0 dB

Interstage Accessories SCI 296743 542048 SCI 204565 SCI 204390 503100 511380

Balanced Triple SCI 202566 544903 SCI 201305 SCI 202557 Quad Single SCI 202556 SCI 202560 PHD Single SCI 202561 SCI 202562 SCI 202563 Low Gain Dual SCI 202564 SCI 201306 SCI 202565 511067 544459

Reverse Combiner SCI 204562 502110

One of the following Interstage Accessories is required for most Unbalanced Triple applications: #542048 #503100 #511380 Single Pilot AGC w/3-9 dB Variable Interstage Equalizer Thermal Compensator w/3-9 dB Variable Interstage Equalizer 3-9 dB Variable Interstage Equalizer

544903 537120

Optional Accessories Order No.


SCI 204542 SCI 296904 SCI 202567 SCI 204547

Mfg. No.
467351 511216 511217 501111

544900 511058 544461

Optional Accessories
#467351 230 Vac Crowbar Surge Protector

Interstage Trim Network, type and use factor, is determined by evaluating actual system frequency response. Use as needed. Status Monitoring Transponder #511216 Circuit Breaker, 5 amp #511217 Circuit Breaker, 8 amp

544899 511052 544457

Unbalanced Triple SCI 202568 544904 SCI 202577 SCI 202576 539327 544460

Related Equipment
#501111 Long Reach Test Point Adapter Specifications and product availability are subject to change without notice. FSA and Surge Resistant Circuitry are trademarks of Scientific-Atlanta, Inc.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H23

1996 TELEWIRE SUPPLY

Distribution Products Accessories

Circuit Breaker SCIENTIFIC-ATLANTA

Description Circuit breakers can be used in place of bridger module output fuses. The circuit breaker plugs in directly in place of the standard fuse. Ordering Information Order No.
SCI 039721

Mfg. No.
156942(PICB)

Load Pad Assembly SCIENTIFIC-ATLANTA

Description This 75 ohm termination mates with the coaxial female connectors located in the trunk station amplifier housing module sockets. This assembly is employed to terminate critical module output cables when operational modules are not used. The load pad assembly is primarily used to terminate trunk feeds to the bridger and automatic control modules when these modules are not included as part of the station. Ordering Information Order No.
SCI 039720

Mfg. No.
035919(LPA-75)

Thermal Compensators SCIENTIFIC-ATLANTA


Ordering Information Order No.
SCI 039741 used SCI 204088

Mfg. No.
276480 373045

Description
550 MHz, compensates for 10 dB of cable, in intermediate/terminating trunk modules 550 Mhz, compensates for 10 dB of cable plus 10 taps, used in line extender amplifiers

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H24

Distribution Products Accessories

Line Extender / Distribution Amplifier Reverse Kits SCIENTIFIC-ATLANTA


Description Forward line extenders and distribution amplifiers can be converted to sub-split twoway operation with the reverse kit. Ordering Information Order No.
SCI 058786

Mfg. No.
371126

Description
Sub-split reverse kit with 22 dB gain hybrid and two diplex filters. Station operational gain is 19 dB. Used with LE I line extenders. Sub-split reverse kit for use with LE II line extenders. With reverse hybrid and 2 diplex filters (5-30 MHz).

SCI 201312

499474

Diplex Filters SCIENTIFIC-ATLANTA

Description Diplex filters are used in the trunk amplifier, bridger amplifier and line extender amplifier modules for routing of forward and return signals. Forward trunk and line extender modules accept two plug-in diplex filters and the bridger amplifier modules accept one. Diplex filters plug into the respective modules in place of diplex jumpers which are shipped standard in all modules.

MHz Flatness Insertion Loss Chromiance to Luminance Delay

5-30 0.1 dB 0.2 dB 6ns (T10)

54-550 0.1 dB 0.2 dB 2ns (Ch. 2)

Ordering Information Order No. Mfg. No.


375120 467230

Description
Sub-split diplex filter for trunk stations and line extenders Sub-split diplex filter for LE II line extenders

SCI 049004 SCI 204541

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H25

1996 TELEWIRE SUPPLY

Distribution Products Accessories

Plug-In Cable Equalizers SCIENTIFIC-ATLANTA


Ordering Information
Telewire Supply Order No. (Prefix=SCI) Eq.Value dB 0 1.5 3.0 4.5 6.0 7.5 9.0 550 MHz SCI 043646 SCI 202482 SCI 204091 SCI 204092 SCI 204093 SCI 204094 SCI 204095 SCI 204096 SCI 204097 SCI 204098 SCI 204099 SCI 204100 SCI 204101 SCI 204102 SCI 204103 SCI 204104 SCI 204105 SCI 204106 SCI 204107 SCI 204108 SCI 204109 750 MHz SCI 043646 SCI 204401 SCI 204548 SCI 204549 SCI 204550 SCI 204551 SCI 204552 SCI 204553 SCI 204554 SCI 204555 SCI 204556 SCI 204557 SCI 204558 SCI 204559 SCI 204560 SCI 204561 SCI 202487 SCI 202486 SCI 202485 SCI 202484 SCI 202483

Description Plug-in equalizers are required at the input of all forward trunk, bridger, line extender and distribution amplifiers, and at the output of all reverse trunk, line extender and distribution amplifiers. Equalizer values are expressed in terms of cable attenuation in dB at the upper frequency. All forward equalizers are selected according to the upper frequency attenuation of the cable on the input side of the forward amplifier. Reverse equalizers are selected according to the upper frequency attenuation of the cable on the output side of the reverse amplifier. Maximum insertion loss:1 dB at upper frequency. Flatness - cable equivalent: 0.1 dB.

10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 22.5 24.0 25.5 27.0 28.5 30.0

Plug-In Pads
Description Plug-in pads are required in all bridger amplifiers, at the input of all forward modules and at the output of all reverse modules. Where reverse is activated through a bridger, an additional pad is required in the bridger path of the reverse trunk module for Scientific-Atlanta distribution equipment. Pad Calculation Forward modules pad = amplifier gain - upper frequency losses input side of amplifier (include cable and flat loss) Return modules pad = amplifier gain - upper frequency loss output side of amplifier (include cable and flat loss) Ordering Information
Order No. ATN 039730 ATN 048986 ATN 039731 ATN 039732 ATN 039733 ATN 039734 ATN 039735 ATN 039736 ATN 039737 ATN 039738 ATN 039739 Mfg. No. PP-O PP-0.5 PP-1 PP-2 PP-3 PP-4 PP-5 PP-6 PP-7 PP-8 PP-9 Order No. ATN 039740 ATN 041438 ATN 041439 ATN 041440 ATN 041441 ATN 041442 ATN 088786 ATN 088787 ATN 088788 ATN 088789 ATN 088790 Mfg. No. PP-10 PP-11 PP-12 PP-13 PP-14 PP-15 PP-16 PP-17 PP-18 PP-19 PP-20

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H26

Distribution Products Accessories

True Tilt Correction Network SCIENTIFIC-ATLANTA


Description During initial set-up of the system, the true tilt correction network allows conversion of true tilt signals to a flat response. The network is connected between the test point and the field test equipment with a short length of 75 ohm test cable. This results in a flat overall signal amplitude (frequency response observed when the signals are properly tilted). Measurements can thus be made without lengthy, error-producing calculations to ascertain flatness of response. Frequency response: cable equivalent 0.2 dB. Ordering Information
Order No. SCI 292526 SCI 140305 SCI 202517 SCI 292430 SCI 202518 Mfg. No. 344332 344331 507720 503782 509709 True Tilt 3 dB 9 dB 6 dB 9 dB 11 dB Drop Insertion Loss 550 MHz 550 MHz 750 MHz 750 MHz 750 MHz

Bridger Feeder Makers SCIENTIFIC-ATLANTA


Specifications
Insertion loss 50-550 MHz 1-way: 2 way: 3-way: 0.5 dB max. 3.5 0.5 dB low loss ports: 3.5 0.5 dB high loss ports: 7.0 0.5 dB

4-way: Return loss

7.0 0.5 dB 18 dB

Ordering Information Description Bridger feeder makers are available in one, two, three or four output configurations. One of the four types is required with each bridger module to activate trunk station feeder ports Order No.
SCI 039742 SCI 039743 SCI 039744 SCI 039745

Mfg. No.
463900 (BFM-1) 463903 (BFM-2) 463906 (BFM-3) 463907 (BFM-4)

Long Reach Test Point Adapter SCIENTIFIC-ATLANTA

Description This 75 ohm push-in adapter permits a test cable to be connected to test points in a trunk station or line extender module. These adapters are long enough to reach through the module housing to the test point inside. The push-in test point exhibits negligible insertion loss. Ordering Information Order No.
SCI 039719

Mfg. No.
035960

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H27

1996 TELEWIRE SUPPLY

Distribution Products Accessories

Jumper & Passives SCIENTIFIC-ATLANTA


Ordering Information Description For use with distribution amplifiers and intermediate/ terminating trunk modules. Order jumpers and passives as follows: If only one output is activated, order 1 jumper. If two outputs are activated, order one jumper and one passive. If 3 outputs are activated , order 2 passives. Order No.
SCI 147981 SCI 134804 SCI 204562 SCI 204564

Mfg. No.
467778 372352 502110 502120

Description
jumper 2-way splitter DC-8 DC-12

Cable Seizure Wrench SCIENTIFIC-ATLANTA

Description Machined from high grade stainless steel, the wrench is used to loosen or secure the cable seizure fittings in the trunk and line extender housings. The steel pins are field replaceable. Ordering Information Order No.
SCI 040028

Mfg. No.
143190 (CT-1)

Drop Adapter SCIENTIFIC-ATLANTA


Description This 75 ohm adapter permits a semi-permanent RG59 test cable to be connected to the trunk station test point and run to the bottom of the pole for easy access. The drop adapter screws into the standard trunk station external test points. The drop adapters exhibit negligible insertion loss. For slim line trunk housings. Ordering Information Order No.
SCI 051718

Mfg. No.
231390

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H28

Distribution Products Power Supplies

36 Volt Standby Power Supply


POWER GUARD

Specifications
AC input voltage AC line frequency Output voltage Output Amps 115 VAC 15 VAC RMS sine wave 60 Hz nominal 60 VAC RMS nominal SL-6015-36-S1: 15 SL-6012-36-S1: 12 SL-6009-36-S1: 9 2% 8 seconds nominal 87-92% maximum 36 VDC 5% 5% 16-20 hours typical 3 hours (load dependent) 15 milliseconds typical 90% maximum

Output regulation Output transfer delay Efficiency DC input voltage Load regulation Line regulation

Features High efficiency Totally modular design Ferroresonant module easily interchanges with "FL" series power supply Lightweight all aluminum mini-cabinet Thermostatically controlled battery charging Climate controlled battery compartment Input surge protection No power loss when either module is removed Easy access test points Short circuit and overload protected Automatic restart after short is removed Power company approved quick disconnect Two year warranty on ferro and standby modules Status monitoring capable Ordering Information - Housings

Recharge time Run time Transfer time DC efficiency

Operating temperature -40F to +140F Size Weight 17.6" H x 23" W x 20" D SL-6015-36-S1: 82 lbs. SL-6012-36-S1: 78 lbs. SL-6009-36-S1: 75 lbs.

For each power supply required, order one housing, one inverter module and one ferroresonant module.

Ordering Information - Ferroresonant Modules Description


Pole mount housing for 36 standby power supply

Order No.
PWR 153205 Volt

Mfg. No.
SLP-H201-S1

Order No.
PWR 140959 PWR 140960 PWR 140961 PWR 140962

Mfg. No.
FLM-6015 FLM-6012 FLM-6009 FLM-6006 FLM-6003 FLM-6015-A FLM-6012-A FLM-6009-A

Description
15 Amp ferroresonant module 12 Amp ferroresonant module 9 Amp ferroresonant module 6 Amp ferroresonant module 3 Amp ferroresonant module 15 Amp ferroresonant module with AMP meter 12 Amp ferroresonant module with AMP meter 9 Amp ferroresonant module with AMP meter

Ordering Information - Inverter Modules Order No.


PWR 146961 options PWR 148888

Mfg. No.
SLM-6015-36 SLM-6015-36EH

Description
36 Volt module without 36 Volt module with E (event counter) and H (hour meter elapsed time) options

PWR 140963 PWR 158576 PWR 158578 PWR 158577

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H29

1996 TELEWIRE SUPPLY

Distribution Products Power Supplies

24 Volt Standby Power Supply


POWER GUARD

Specifications
AC input voltage AC line frequency Output voltage Output Amps 115 VAC 15 VAC RMS sine wave 60 Hz nominal 60 VAC RMS nominal SL-6015-24-S1: 15 SL-6012-24-S1: 12 SL-6009-24-S1: 9 2% 8 seconds nominal 87-92% maximum 24 VDC 5% 5% 16-20 hours typical 2 hours (load dependent) 15 milliseconds typical 90% maximum

Output regulation Output transfer delay Efficiency DC input voltage Load regulation

Features High efficiency Totally modular design Ferroresonant module easily interchanges with "FL" series power supply Lightweight all aluminum mini-cabinet Thermostatically controlled battery charging Climate controlled battery compartment Input surge protection No power loss when either module is removed Easy access test points Short circuit and overload protected Automatic restart after short is removed Power company approved quick disconnect Two year warranty on ferro and standby modules

Line regulation Recharge time Run time Transfer time DC efficiency

Operating temperature -40F to +140F Size Weight 17.6" H x 15.5" W x 20" D SL-6015-24-S1: 82 lbs. SL-6012-24-S1: 78 lbs. SL-6009-24-S1: 75 lbs.

For each power supply required, order one housing, one inverter module and one ferroresonant module.

Ordering Information - Housings Order No.


PWR 148889 Volt

Ordering Information - Ferroresonant Modules Order No.


PWR 140959 PWR 140960 PWR 140961

Mfg. No.
SLP-H600

Description
Pole mount housing for 24 standby power supply

Mfg. No.
FLM-6015 FLM-6012 FLM-6009 FLM-6006 FLM-6003 FLM-6015-A FLM-6012-A FLM-6009-A

H
Description
15 Amp ferroresonant module 12 Amp ferroresonant module 9 Amp ferroresonant module 6 Amp ferroresonant module 3 Amp ferroresonant module 15 Amp ferroresonant module with AMP meter 12 Amp ferroresonant module with AMP meter 9 Amp ferroresonant module with AMP meter

Ordering Information - Inverter Modules Order No.


PWR 146960 PWR 148887

PWR 140962 PWR 140963

Mfg. No.
SLM-6015-24 SLM-6015-24EH

Description
24 Volt module without options 24 Volt module with E (event counter) and H (hour meter-elapsed time) options

PWR 158576 PWR 158578 PWR 158577

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H30

Distribution Products Power Supplies

Modular Pole Mount Power Supply


POWER GUARD
Specifications
AC input voltage AC line frequency Output voltage Output Amps 115 VAC 15 VAC RMS sine wave 60 Hz nominal 60 VAC RMS nominal FLP-6015-0: 15 FLP-6012-0: 12 FLP-6009-0: 9 FLP-6006-0: 6 FLP-6003-0: 3 FLP-6015-0: 1000 FLP-6012-0: 800 FLP-6009-0: 600 FLP-6006-0: 400 FLP-6003-0: 200 FLP-6015-0: 900 FLP-6012-0: 720 FLP-6009-0: 540 FLP-6006-0: 360 FLP-6003-0: 180 -40F to +140F 11.4" H x 8.5" W x 7.1" D FLP-6015-0: 31.65 lbs. FLP-6012-0: 30.15 lbs. FLP-6009-0: 24.85 lbs. FLP-6006-0: 23.15 lbs. FLP-6003-0: 16.95 lbs.

Input power (Volt/Amps)

Output power (Volt/Amps)

Features High efficiency Totally modular design Ferroreonant module easily interchanges with "FL" series power supply Lightweight all aluminum mini-cabinet Built-in surge protection Auxiliary AC convenience outlet Security lock Automatic short circuit and overload protection Automatic restart when overload is removed Power company approved quick disconnect Five year warranty

Operating temperature Size Weight

For each power supply required, order one housing, and one ferroresonant module.

Ordering Information - Housings

Ordering Information - Ferroresonant Modules Description


Modular pole mount power supply housing

Order No.
PWR 149288

Mfg. No.
FLP-H100

Order No.
PWR 140959 PWR 140960 PWR 140961 PWR 140962 PWR 140963 PWR 158576 PWR 158578 PWR 158577

Mfg. No.
FLM-6015 FLM-6012 FLM-6009 FLM-6006 FLM-6003 FLM-6015-A FLM-6012-A FLM-6009-A

Description
15 Amp ferroresonant module 12 Amp ferroresonant module 9 Amp ferroresonant module 6 Amp ferroresonant module 3 Amp ferroresonant module 15 Amp ferroresonant module with AMP meter 12 Amp ferroresonant module with AMP meter 9 Amp ferroresonant module with AMP meter

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H31

1996 TELEWIRE SUPPLY

Distribution Products Power Supplies

Power Supply Options


POWER GUARD
Ordering Information
Order No.
PWR 131023 PWR 131025 PWR 131024 PWR 142591 PWR 131046 PWR 137206

Mfg. No.
T T2 T3 C P1 M1

Amps

Weight

Time delay, 10 seconds typical Time delay, with fused link PIP-60 Time delay and power clamp crowbar circuit Power clamp crowbar circuit Fused link PIP-60 120 joule input surge protection with indicator lamp

Breaker Box
POWER GUARD
Description Breaker box (UL Listed) with quick disconnect and 120 joule surge protection. Ordering Information Order No.
PWR 131043

Mfg. No.
PCB-2

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H32

Distribution Products Power Supplies

G-100 Gel Technology Battery


POWER GUARD
Description Sealed, Recombinant Battery, Gel Type, 12 volt, 86 amp hour, with flag terminal. Power Guards premium G-100 "Gel" Technology battery is the newest, cutting edge battery designed specifically for the broadband communications industry. This battery boasts many features which make it the most reliable, long lasting, dependable battery on the market. The G100, utilizing gel electrolyte, has many benefits because it resists sulfation, to a high degree, unlike conventional liquid acid batteries. The G-100 battery, therefore, has a longer life, provides increased operating time and is maintenance-free. Compu-cast, power path grids and computer-controlled oxide provide your broadband communications system with maximum durability, power and life. The G-100 "Gel" technology battery has effectively captured all of the best features of conventional batteries in a gel design. The sealed recombinant construction provides added protection to your electronic equipment and technicians through the elimination of dangerous spills, leaks, gases and terminal corrosion. Power Guards G-100 batteries have a reduced self discharge rate of less than 1% per month so that dependable power is available when you need it. For your convenience, handles and hardware are included to facilitate transport and installation. Power Guards G-100 "Gel" technology battery for all the power you need. Ordering Information Order No.
MKB 250192

Features 6 cells per battery 610 amp maximum discharge current 12.7 volts per battery 5535 watts available for one minute watts to 1.50 VPC 4.0 milliohms resistance (full charge) Gelled electrolyte Fully charged operating temperature range is -76F (-60C) to 140F(60C) Float charging voltage is 13.5 to 13.8 VDC @ 68F (20) Cycle serive charging voltage is 13.5 to 14.1 VDC @ 68F (20) Charger ripple is 30 mv/cell (180 mv)

Mfg. No.
G-100

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H33

1996 TELEWIRE SUPPLY

Distribution Products Power Clamp

Power Clamp
POWER GUARD
Ordering Information - Bandwith 1GHz
Order No.
PWR 250778 PWR 136741

Mfg. No.
CR110 CR101

For use with


REGAL RPI-100 Power Inserter Regal RLS6-2 Splitter Regal RLS6-3 Splitter Regal RLDC6-8 Directional Coupler Regal RLDC6-12 Directional Coupler Regal RLDC6-16 Directional Coupler Regal RLS 10-3 Regal RLS10-2 Splitters Regal RLDC10-8 Directional Coupler Regal RLDC10-12 Directional Coupler Regal RLDC10-16 Directional Coupler Magnavox 9-LPI Power Inserter Magnavox 9-TFC-4 Splitter Magnavox 9-TFC-488 Splitter Magnavox 9-TFC-8 Directional Coupler Magnavox 9-TFC-12 Directional Coupler Magnavox 9-TFC-16 Directional Coupler Magnavox 9-TFC-777 Splitter Scientific-Atlanta SAIFW-RFI Power Inserter Scientific-Atlanta SAS2-G Splitter Scientific-Atlanta SAS3-G Splitter Scientific-Atlanta SAS8-G Directional Coupler Scientific-Atlanta SAS12-G Directional Coupler Scientific-Atlanta SAS16-G Directional Coupler

PWR 202446 PWR 202433

CR112 CR111

Description The Power Guard Power Clamp series of CATV system protectors adds protection at discrete points throughout the distribution system for high system reliability in areas prone to power surges or lightning strikes. This bi-directional circuit provides a low impedance surge clamping action for AC circuits. The Power Guard design uses two SCRs, which will conduct surges of all polarities. The Power Clamp is available in several kits designed for retro-fit of existing power inserters, distribution splitters, and couplers. All kits are custom designed for easy installation or replacement, and each is securely mounted and grounded with integral brackets. Each kit is supplied with required hardware and complete instructions. Specifications Dual 70A RMS SCR Design Trigger Voltage: 14V pk min. 150V pk nom. (protects up to 60VAC CATV line at 50 or 60 HZ) Trigger Response: Less than 60ns Peak Test Current Capacity: 3000 amps peak in IEEE standard 8 X 20 .s wave Clamp Duration: to 1/2 line frequency max. (8.3 - 10ms)

PWR 250522 PWR 202434

CM120 CA111

PWR 202432 PWR 202430 PWR 202431

CA113 CS120 CS111

All 1 GHz, except CR101 (750 MHz). Other models available, contact your TeleWire Sales Representative for details.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H34

Distribution Products Taps & Line Passives

Taps
REGAL

Line Passives
REGAL

Description ANTECs commitment to excellence in design and engineering is exemplified in its Regal tap and line passive product lines. Regal has always been recognized as the industry leader in quality, performance and innovation. During the past five years, more than 50 million Regal passives have been deployed in over 60 percent of the broadband networks in the United States. The need for added capacity and reliability is clear as the broadband industry moves toward the deployment of near video on demand, high definition television, digital signaling and fiber rich architectures. Installing Taps and line passives optimizes signal levels to the drop, provides the capacity needed to accommodates future services, and ensures reliable signal transmission to your customers. Enhancements to the Regal line include: power passing and non-power passing taps; interchangeable faceplate between 600 MHz, 750 MHz and 1 GHz taps and line passives.

Features Interlocking tongue and groove housing prohibits ingress and egress and provides excellent EMI isolation. Water tight, sealed backplate eliminates water damage to circuit board. Interchangeable faceplates provide cost efficient migration path to 1 GHz. 1/2" long, numbered F ports allows proper connector fit and use of sealing sleeves. Cast-in strip gauge facilitates proper center conductor trim length. Conical center conductor guide assists in accurate feeder line installs. Triple sealed, nickel plated, brass F ports inhibits water migration and resists corrosion. Glass epoxy printed circuit board with premium components for superior RF performance. Wide body 5-3/16" entry to exit port and narrow body 31/2" entry to exit port sizes provide quicker, easier, more cost efficient upgrades. 1 KV blocking capacitor on the F port increases tap ruggedness.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H35

1996 TELEWIRE SUPPLY

Distribution Products Taps & Line Passives

Features

5/8" port entry extensions Strip gauge for correct center conductor trim length Plated 360 aluminum alloy housing Double polyurethane coating Neoprene seal on each port Sealed nickel plated brass F ports Protective plastic washer under plate hold-down bolt O ring to seal interface between faceplate and F port Non-rotational center conductor seizing mechanism Stainless steel hardware Color coded tap value label Integral, surge resistant blocking capacitor

Printed circuit board with premium components Neoprene weather gasket between housing and faceplate Woven metallic RFI gasket in housing channel

Epoxy sealed F ports Interlocking tongue and groove faceplate/housing channel Protective plastic cover

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H36

Distribution Products Taps

750 MHz Two Way Narrow Body Tap


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H37

1996 TELEWIRE SUPPLY

Distribution Products Taps

750 MHz Four Way Narrow Body Tap


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H38

Distribution Products Taps

750 MHz Eight Way Wide Body Tap


REGAL

All 8 way taps are wide body Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H39

1996 TELEWIRE SUPPLY

Distribution Products Line Splitters

750 MHz Line Splitters


REGAL

*5-20

*20-50

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H40

Directional Couplers & Power Inserters

Distribution Products

750 MHz Directional Couplers


REGAL

750 MHz Power Inserters


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H41

1996 TELEWIRE SUPPLY

Distribution Products Line Equalizers

Line Equalizers
REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H42

Distribution Products Taps

1GHz Two Way Narrow Body Tap with Blocking Capacitors


REGAL

Specifications subject to change without notice

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H43

1996 TELEWIRE SUPPLY

Distribution Products Taps

1GHz Two Way Narrow Body Tap with Blocking Capacitors continued
REGAL

Recommended Torque

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H44

Distribution Products Taps

1 GHz Four Way Narrow Body Tap with Blocking Capacitors


REGAL

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H45

1996 TELEWIRE SUPPLY

Distribution Products Taps

1GHz Four Way Narrow Body Tap with Blocking Capacitors continued
REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H46

Distribution Products Taps

1 GHz Eight Way Wide Body Tap with Blocking Capacitors


REGAL

All 8 way taps are wide body


SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

H47

1996 TELEWIRE SUPPLY

Distribution Products Taps

1 GHz Eight Way Wide Body Tap with Blocking Capacitors continued
REGAL

Recommended Torque

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H48

Distribution Products Taps

1GHz Two Way Wide Body Tap


REGAL

65

65

65

65

65

65

65

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H49

1996 TELEWIRE SUPPLY

Distribution Products Taps

1GHz Two Way Wide Body Tap continued


REGAL

Recommended Torque

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H50

Distribution Products Taps

1GHz Four Way Wide Body Tap


REGAL

65

65

65 7

65

65

65

65

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H51

1996 TELEWIRE SUPPLY

Distribution Products Taps

1GHz Four Way Wide Body Tap continued


REGAL

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H52

Distribution Products Line Passives

1GHz Line Splitter


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H53

1996 TELEWIRE SUPPLY

Distribution Products Line Passives

1GHz Line Splitter continued


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H54

Distribution Products Line Passives

1GHz Directional Couplers


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H55

1996 TELEWIRE SUPPLY

Distribution Products Line Passives

1GHz Directional Couplers continued


REGAL

Ordering Information on Pages H57-H59

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H56

Distribution Products Taps & Line Passives

Regal Tap & Passives Ordering Information


Regal is proud to introduce the RMT Multitap which incorporates both Blocking Cap and Continuous Power Bus (CPB) technologies. The RMT taps will not deliver power to the drop, but will provide continuous power and RF signal even with the faceplate removed. When the operator decides to upgrade, or needs to replace a tap faceplate, there will be no service interruption to any subscriber other than those served by that particular tap. The nomenclature for these products will have a "BCP" suffix in the model number to denote the inclusion of both Blocking Caps and CPB technologies ("BC" for Blocking Cap,"P for continuous Power). The CPB kit does not provide power to the drop. Only the Power Passing Upgrade Kit provides power to the drop. This feature will enable operators to provide advanced cable/telephony service to their subscribers by delivering power to Network Interface Devices (NIDs) at the home. Two powering options will be available, either on the same coaxial cable that currently provides RF signal, or down a twisted pair adjacent to the coax. Consult your Telewire Supply Sales Representative for details on these products. Glossary of Terms CPB - Continuous Power Bus: Provides downstream power and RF signal with tap faceplate removed Surge Protection: Optional feature for all line passives (RPI, RLS, RLDC). Shunts voltage surges to ground, protecting the active passive system components. Voltage surges can be from lightning, power supply surges and power grid surges. Blocking Caps: Capacitors that block AC voltages to the drop. This reduces hum mod distortion and reduces damage to the drop.

Ordering Information Regal Narrow Body 1GHz Taps with Continuous Power Bus and Blocking Capacitors 2 Way Taps Order No.
REG 201158 REG 250979 REG 250980 REG 250981 REG 250982

Mfg. No.
RMT102BCP-4 RMT102BCP-8 RMT102BCP-11 RMT102BCP-14 RMT102BCP-17 RMT102BCP-20 RMT102BCP-23 RMT102BCP-26 RMT102BCP-29 RMT102BCP-32 RMT102BCP-35

4 Way Taps Order No.


REG 201168 REG 250990 REG 250991 REG 250992 REG 250993 REG 250994 REG 250995 REG 250996 REG 250997 REG 250998

Mfg. No.
RMT104BCP-8 RMT104BCP-11 RMT104BCP-14 RMT104BCP-17 RMT104BCP-20 RMT104BCP-23 RMT104BCP-26 RMT104BCP-29 RMT104BCP-32 RMT104BCP-35

8 Way Taps Order No.


REG 201178 REG 251000 REG 251001 REG 251002 REG 251003 REG 251004 REG 251005 REG 251006 REG 251007

Mfg. No.
RMT108BCP-11 RMT108BCP-14 RMT108BCP-17 RMT108BCP-20 RMT108BCP-23 RMT108BCP-26 RMT108BCP-29 RMT108BCP-32 RMT108BCP-35

REG 250983 REG 250984 REG 250985 REG 250986 REG 250987 REG 250988

All Regal Nominal Performance specifications provided reflect temperature cycled conditions

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H57

1996 TELEWIRE SUPPLY

Distribution Products Ordering Information

Ordering Information
Regal Narrow Body 1GHz Taps with Blocking Capacitors 2 Way Tap Order Mfg. No. No.
REG 201158 RMT102BC-4 REG 201159 RMT102BC-8 REG 201160 RMT102BC-11 REG 201161 RMT102BC-14 REG 201162 RMT102BC-17 REG 201163 RMT102BC-20 REG 201164 RMT102BC-23 REG 201165 RMT102BC-26 REG 201166 RMT102BC-29 REG 201167 RMT102BC-32 REG 201187 RMT102BC-35

4 Way Tap Order Mfg. No. No.


REG 201168 RMT104BC-8 REG 201169 RMT104BC-11 REG 201170 RMT104BC-14 REG 201171 RMT104BC-17 REG 201172 RMT104BC-20 REG 201173 RMT104BC-23 REG 201174 RMT104BC-26 REG 201175 RMT104BC-29 REG 201176 RMT104BC-32 REG 201177 RMT104BC-35

8 Way Tap Order Mfg. No. No.


REG 201178 RMT108BC-11 REG 201179 RMT108BC-14 REG 201180 RMT108BC-17 REG 201181 RMT108BC-20 REG 201182 RMT108BC-23 REG 201183 RMT108BC-26 REG 201184 RMT108BC-29 REG 201185 RMT108BC-32 REG 201186 RMT108BC-35

Regal Narrow Body 750 MHz Taps 2 Way Tap Order No.
REG 250195 REG 250196 REG 250197 REG 250298 REG 250299 REG 250200 REG 250201 REG 250202 REG 250203 REG 250204 REG 250205

Mfg. No.
RMT752-4 RMT752-8 RMT752-11 RMT752-14 RMT752-17 RMT752-20 RMT752-23 RMT752-26 RMT752-29 RMT752-32 RMT752-35

4 Way Tap Order No.


REG 250206 REG 250207 REG 250208 REG 250209 REG 250210 REG 250211 REG 250212 REG 250213 REG 250214 REG 250215

Mfg. No.
RMT754-8 RMT754-11 RMT754-14 RMT754-17 RMT754-20 RMT754-23 RMT754-26 RMT754-29 RMT754-32 RMT754-35

8 Way Tap Order No.


REG 250216 REG 250217 REG 250218 REG 250219 REG 250220 REG 250221 REG 250222 REG 250223 REG 250224 REG 250225

Mfg. No.
RMT758-1 RMT758-14 RMT758-17 RMT758-20 RMT758-23 RMT758-26 RMT758-29 RMT758-32 RMT758-35 RMT758-38

* All 8 way taps are wide body

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H58

Distribution Products Ordering Information

Ordering Information
Regal Wide Body 1GHz 2 & 4 Way Taps without Blocking Capacitors 8 Way Taps with Blocking Capacitors 2 Way Tap Order No.
REG 154672 REG 154673 REG 154674 REG 154675 REG 154676 REG 154677 REG 154678 REG 154679 REG 154680 REG 154681 REG 154682

Mfg. No.
RMT102W-4 RMT102W-8 RMT102W-11 RMT102W-14 RMT102W-17 RMT102W-20 RMT102W-23 RMT102W-26 RMT102W-29 RMT102W-32 RMT102W-35

4 Way Tap Order No.


REG 137516 REG 137517 REG 137518 REG 137519 REG 137520 REG 137521 REG 137522 REG 137525 REG 137526 REG 137527

Mfg. No.
RMT104W-8 RMT104W-11 RMT104W-14 RMT104W-17 RMT104W-20 RMT104W-23 RMT104W-26 RMT104W-29 RMT104W-32 RMT104W-35

8 Way Tap Order No.


REG 201178 REG 201179 REG 201180 REG 201181 REG 201182 REG 201183 REG 201184 REG 201185 REG 201186

Mfg. No.
RMT108BC-11 RMT108BC-14 RMT108BC-17 RMT108BC-20 RMT108BC-23 RMT108BC-26 RMT108BC-29 RMT108BC-32 RMT108BC-35

Power Inserters
Order No.
REG 250228 REG 139232 REG 139227

Ordering Information - Directional Couplers


Mfg. No.
RPI75-70 RPI-100 RPI-100SP

Description
750 MHZ 1 GHz 1 GHz with surge protection

Order No.
REG 250229 REG 139230 REG 139224 REG 250230 REG 139229 REG 139223

Mfg. No.
RLDC75-8 RLDC10-8 RLDC10-8SP RLDC75-12 RLDC10-12 RLDC10-12SP RLDC75-16 RLDC10-16 RLDC10-16SP

Description
750 MHZ 8dB 1 GHz 8dB 1 GHz 8dB with surge protection 750 MHZ 12dB 1 GHz 12dB 1 GHz 12dB with surge protection 750 MHZ 16dB 1 GHz 16dB 1 GHz 16dB with surge protection

Ordering Information - 2 Way Line Splitters


Order No. Mfg. No.
RLS75-2 RLS10-2 RLS10-2SP

REG 250231 REG 139228

Description
750 MHZ 1 GHz 1 GHz with surge protection

REG 139222

REG 250226 REG 139233 REG 139226

Ordering Information - Line Equalizers


Order No. Mfg. No.
RLEQ-8-550 RLEQ-10-750 RLEQ-12-1000

Description
550 MHZ 750 MHZ 1 GHz

Ordering Information - 3 Way Line Splitters


Order No.
REG 250227 REG 139234 REG 139225 REG 143533

REG 148752 REG 156844

Mfg. No.
RLS75-3 RLS10-3 RLS10-3SP RLS10-3B

Description
750 MHZ 1 GHz 1 GHz with surge protection 1 GHz with balanced outputs

REG 201261

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H59

1996 TELEWIRE SUPPLY

Distribution Products Continuous Power Bus Kits

Retrofit Continuous Power Bus Kit


REGAL
Description Retrofit Kits to add the Continuous Power Bus feature allowing the RF signal and power to continue down stream with the tap face plate removed. Ordering Information Order No.
REG 251506 REG 251507

Mfg. No.
RMT-CPBN RMT-CPBW

Description
for Regal narrow body taps for Regal wide body taps

In-Line Equalizers - 550-750 MHz SCIENTIFIC-ATLANTA

In-line equalizers
Frequency range Return loss, minimum Cable equalization Frequency response, all models Tilt - low pass Insertion loss Power passing Hum modulation LEQ 550: 54-500 MHz, all models 5-30 MHz 16 dB 11 dB 0.1 dB 0.5 dB all models LEQ 550 8.3 dB @ 54 MHz, 1.0 dB @ 550 MHz. All models: 0.5 dB @ 30 MHz 6A -70 dB at 6 A

Ordering Information Order No.


SCI 138163

Mfg. No.
LEQ 550

Description
Fixed value equalizer

Ordering Information Order No.


SCI 110069

Mfg. No.
504064

Description
Equalizer housing only

Plug-in equalizer module must be ordered separately, from page H26

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H60

Distribution Products System Passives

System Passives - 750 MHz SCIENTIFIC-ATLANTA

Specifications - splitters and directional couplers


Frequency range Frequency response, cable equivalent, all ports Return loss, all ports Hum modulation at 10 A Power passing 5-750 MHz 0.35 dB

5-450 MHz: 20 dB, 450-750 MHz: 18 dB 5-10 MHz: 68 dB, 10-450 MHz: 70 dB 450-550 MHz: 67 dB, 550-750 MHz: 64 dB 10 A, 60 VAC, 60 Hz

Power inserter
Frequency range 5-750 MHz 0.35 dB

Ordering Information Order No.


SCI 204029 SCI 148725 SCI 148726 SCI 204027 SCI 148728 SCI 148729 SCI 148730

Frequency response, cable equivalent, all ports Return loss, all ports

Mfg. No.
SAS2F SAS3F SAS3UF SADC8F SADC12F SADC16F SAIF

5-450 MHz: 20 dB, 450-750 MHz: 18 dB

Hum modulation at 10 A 5-10 MHz: 68 dB, 10-450 MHz: 70 dB 450-550 MHz: 67 dB, 550-750 MHz: 64 dB Power passing 15 A, 60 VAC max. input port10 A, 60 VAC max. output port no more than 15A total two output ports

Mfg. No. Splitters SAS2F

Type/tap loss 2-way

5 MHz 3.8 6.3 3.8 6.3 1.4 0.7 0.6 0.3

30 MHz 3.7 5.7 3.7 5.7 1.5 0.9 0.7 0.4

Maximum insertion loss (dB) 50 400 450 550 MHz MHz MHz MHz 3.7 5.7 3.7 5.7 1.5 0.9 0.7 0.4 3.8 5.9 3.8 5.9 1.6 1.1 0.9 0.5 4.0 6.0 4.0 6.0 1.7 1.2 0.9 0.5 4.3 6.1 4.3 6.5 2.0 1.6 1.3 0.6

600 MHz 4.3 6.8 4.3 7.4 2.0 1.6 1.3 0.8

750 MHz 4.6 7.2 4.9 8.2 2.4 2.0 1.7 1.2

SAS3F 3-way balanced SAS3UF H 3-way unbalanced L Directional couplers SADC8F SADC12F SADC16F 8.5 12.0 16.0 ---

Power inserter SAIF

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H61

1996 TELEWIRE SUPPLY

Distribution Products Distribution Products

Multi-Taps - 750 MHz SCIENTIFIC-ATLANTA

Features Brass F ports, tin plated Standard polymer coating for environmental protection Sealed extended F-ports for superior sealing against moisture ingress Component covers for additional protection of circuitry during maintenance Faceplate inter-changeability for 2 and 4-way taps Aerial or pedestal mounting Modular design allows changing of board and cover without removal of housing from cable

Order No.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H62

Distribution Products MDU - Distribution Amplifiers

One and Two -Way Signal Stretcher Amplifiers


AUGAT BROADBAND

Multiple Dwelling Amplifier


AUGAT BROADBAND

Description The Signal Stretcher amplifier provides additional gain for long house drops, multiple TV outlets or multiple service requirements at specifications comparable to line extenders. It is also capable of providing quality signals to small apartment and motel distribution systems. To meet a variety of system needs, the Signal Stretcher is available in one output and one-or two-way passive transmission. All versions provide nearly transparent transmission at typical house drop signal levels. They may be used at higher levels for multiple dwelling distribution systems due to the push-pull technology used in their design. The Signal Stretcher features full channel loading for the design bandwidth and is powered by a UL Listed Class II AC transformer or DC power supply that may be remotely located. DC powered units may also be remotely powered up the drop through the output port by using a power inserter (must order DC powered amplifier) Ordering Information

Description The Multiple Dwelling Amplifier is designed for high performance applications with bandwidths up to 550 MHz, for use in apartments, hotels, motels, CATV or MATV distribution networks or any other application where one-way transmission with 30 dB gain is needed. In addition, the MDA may be used as a general purpose wideband amplifier in the repair shop or as a system sweep post amplifier. The MDA is designed with push-pull hybrids which are installed in plug-in sockets to make down-time short and replacement quick and easy. A die-cast aluminum housing ensures excellent heat transfer from the active devices for lone life and reliable service. The housing can accommodate one or four output ports. To address system balancing, the MDA offers optional plugin equalizers and attenuator pads. The MDA is equipped with a UL Listed Class II transformer that is remotely located from the amplifier. Ordering Information
Order No.
AGB 151131

Mfg. No.
MDA4/30T-1-1W MDA5/30T-1-1W

Description
450 MHz, 30 dB gain, 1-way, one output 550 MHz, 30 dB gain, 2-way, one output

Order No.
AGB 151123 AGB 151124 AGB 151125 AGB 151126 AGB 151127 AGB 151128 AGB 151129

Mfg. No.
SS4/17T-1-1W SS4/17T-1-2W SS5/17T-1-1W SS5/17T-1-2W SS7/17T-1-1W SS7/17T-1-2W SS10/15T-1-2W

Description
450 MHz, 15 dB gain, 1-way, one output 450 MHz, 15 dB gain, 2-way, one output 550 MHz, 15 dB gain, 1-way, one output 550 MHz, 15 dB gain, 2-way, one output 750 MHz, 15 dB gain, 1-way, one output 750 MHz, 15 dB gain, 2-way, one output 1 GHz, 15 dB gain, 2-way, one output

AGB 151132

Specifications are on following pages.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H63

1996 TELEWIRE SUPPLY

Distribution Products MDU - Distribution Products

One and Two-Way Signal Stretcher Amplifier Specifications


AUGAT BROADBAND

1. 2. 3. 4. 5.

Measured with 0 dB pad and equalizer Gain is specified as minimum full gain from input to each output Slope in dB of actual slope from lowest to highest operating frequency Standard channels per NCTA test methods Worst case as measured on a Matrix distortion analyzer utilizing CW carriers

6. Worst case is measured on a Matrix distortion analyzer utilizing a 15.750 Hz square wave and measured to nearest dB, with 100% modulation 7. F1 F2 worst case any two channels relative to nearest operating carrier 8. Pad and equalizer may be ordered for gain and slope control

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H64

Distribution Products MDU - Distribution Amplifiers

Multiple Dwelling Amplifier Specifications


AUGAT BROADBAND

1. All distortions stated as signal-to-distortion ratios. Worst case at output levels shown. 2. Distortion specified to nearest dB as measured on a Matrix distortion analyzer. Crossmod measured with 100% modulation by a 15.750 Hz square wave. CTB measured with CW carriers.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H65

1996 TELEWIRE SUPPLY

Distribution Products MDU - Distribution Amplifiers

Flexible Multiple Dwelling Amplifier


AUGAT BROADBAND

Super Multiple Dwelling Amplifier


AUGAT BROADBAND

Description The Flexible Multiple Dwelling Amplifier is designed for CATV, SMATV and MATV home run or branching systems. This oneway amplifier meets most requirements for apartment, condominium, hotel and motel distribution systems. The XMDA features the latest hybrids (push-pull or power doubling) for the maximum output with a minimum of distortions. When equipped with power doubling hybrids, the XMDA-Plus gives these added design options: system distortions can be reduced by 6 dB while maintaining present output levels, or output levels can be increased by 3 dB with no change in distortions. Ordering Information
Order No.
AGB 151133 AGB 151134 AGB 151135 AGB 151136 AGB 151137

Description The Super Multiple Dwelling Amplifier is designed for CATV, SMATV and MATV home run or branching systems. This twoway amplifier meets most requirements for apartment, condominium, hotel and motel distribution systems. The XMDA features the latest hybrids (push-pull or power doubling) for the maximum output with a minimum of distortions. When equipped with power doubling hybrids, the XMDA-Plus gives these added design options: system distortions can be reduced by 6 dB while maintaining present output levels, or output levels can be increased by 3 dB with no change in distortions. The SMDA may be purchased in a one-way configuration to start and then later a return hybrid may be plugged in to activate the return operation.

Mfg. No.
XMDA4/30L XMDA4/50L XMDA5/30L XMDA5/30LP XMDA5/45L

Description
450 MHz, 30 dB gain, 1-way 450 MHz, 50 dB gain, 1-way 550 MHz, 30 dB gain, 1-way 550 MHz, 30 dB gain, power double,1-way 550 MHz, 45 dB gain, 1-way

Ordering Information
Order No.
AGB 151138 AGB 151141 AGB 151142 AGB 151143

Mfg. No.
SMDA4/33L SMDA4/33LP SMDA5/33L SMDA5/33LP

Description
450 MHz, 33 dB gain, 2-way capable* 450 MHz, 33 dB gain, 2-way capable* 550 MHz, 33 dB gain, 2-way capable* 550 MHz, 33 dB gain, power double, 2-way capable*

Specifications on following pages.

* must order plug-in reverse amplifier separately Specifications on following pages.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H66

Distribution Products MDU - Distribution Amplifiers

Flexible Multiple Dwelling Amplifier Specifications


AUGAT BROADBAND

1. Worst case as measured on a Matrix distortion analyzer. Measurements made with a 15.750 Hz square wave. Measured to nearest dB. 2. Measured on a Matrix distortion analyzer with CW carriers. 3. Measured at 120 VAC input with a Valhalla Model 2101 digital power analyzer.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H67

1996 TELEWIRE SUPPLY

Distribution Products MDU - Distribution Amplifiers

Super Multiple Dwelling Amplifier Specifications


AUGAT BROADBAND

1. Worst case as measured on a Matrix distortion analyzer. Measurements made with a 15.750 Hz square wave. Measured to nearest dB. 2. Measured on a Matrix distortion analyzer with CW carriers. 3. Negative slope measured at 30 MHz.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H68

Distribution Products MDU - Distribution Amplifiers

Distribution Amplifiers BLONDER-TONGUE

Features Hybrid IC circuitry for high output with low distortion Designed for critical applications requiring high gain Exceeds FCC specs for both conducted and radiated interference at full output level External fuse for ease of replacement LED pilot light Line transient protection Available in 300, 450 and 550 MHz bandwidths Description The BIDA is a completely self-contained indoor distribution amplifier designed specifically for signal distribution systems which use a "cable drop" as a signal source. Three models are available: the 5400-35 with 50 to 300 MHz bandpass, the 540045 with 50 to 450 MHz bandpass and the 5400-55 with 50 to 550 MHz bandpass. The basic amplifier is configured for oneway operation. Optional field installable modules provide twoway capability with either a passive or active sub-channel return path. The BIDA has a flat operating gain of 51 dB which can be adjusted down to 41 dB with the variable attenuator. Gain and slope controls are located on the front panel for easy set-up and adjustment. Two -30 dB back-matched test points are provided to permit testing without interruption of service. In applications where input signal levels are too high or where greater cable equalization is necessary, the BIDA can be reconfigured by using plug-in attenuators and cable slope equalizers to meet particular system requirements. Push-pull, hybrid IC modules enable the BIDA to operate at high output levels while retaining low distortion characteristics. The aluminum chassis is designed to provide excellent heat dissipation, thus allowing operation at high ambient temperatures with no degradation of performance or reliability.

Ordering Information Order No.


B-T 092517 B-T 135079 B-T 092516 B-T 142881

Mfg. No.
5400-35, BIDA-300-50 5400-43, BIDA-450-30 5400-45, BIDA-450-50 5400-55, BIDA-550-50

Field Installable Option Equipment BLONDER-TONGUE


BIDA-RF Return Filter Set Plug-in return filter adds passive reverse path to BIDA series amplifiers. Each BIDA-RF contains a high pass (50-450 MHz) and a low pass (5-30 MHz) filter element with a common (5-450 MHz) connecting point. A sheet metal cover is mounted over the circuitry to improve stability and prevent accidental de-tuning during shipping, handling and installation. The filters separate sub-band (return) signals from VHF (forward) signals for processing within the amplifier. Two identical BIDA-RF units in the set make an amplifier bi-directional. A passive return jumper wire is supplied to complete the sub-band path. BIDA-RA Return Amplifier Plug-in return amplifier adds reverse path gain to BIDA series amplifiers. The BIDA-RA is a sub-band (5-30 MHz) amplifier with 24 dB gain. It contains a 12 dB variable slope control and a 12 dB variable gain control. A BIDA-RF return filter set (54011) is required to complete the system.
SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288

BIDA-RF Flat Attenuators These plug-in flat attenuator pads are used to reduce forward gain in BIDA series amplifiers. Ordering Information
Order No.
B-T 115930 BT-125304 B-T 142889 B-T 142876 B-T 142878

Mfg. No.
54071, BIDA RF 5402, BIDA-RA 5410-6, 6 dB 5410-12, 12 dB 5410-18, 18 dB

Description
Return Filter Set Return Amplifier BIDA-RF Flat Attenuators BIDA-RF Flat Attenuators BIDA-RF Flat Attenuators

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

H69

1996 TELEWIRE SUPPLY

Distribution Products MDU - Distribution Amplifiers

Distribution Amplifiers BLONDER-TONGUE

Specifications
Bandwidth 5430: 5440: 5430: 5440: 5430: 5440: 5430: 5440: 5430: 5440: 5430: 5440: 40-300 MHz 40-450 MHz 0.5 dB 0.75 dB 32 dB 32 dB 9 dB 8 dB 9 dB 9 dB 5.5-7.5 dB 5.5-9.0 dB

Flatness

Full gain

Gain control range

Slope control range

Noise figure

Match

Input return loss 5430/5430: 14 dB Output return loss 5430/5440: 14 dB 5430/5440: -65 dB 5430: 5440: -100 dB -110 dB

Features Hybrid IC circuitry for high output with low distortion Temperature stability range of -18C to +60C Front panel gain and slope controls for easy adjustment Low 40 MHz band edge Aluminum chassis designed for superior heat dissipation to ensure component reliability Exceeds FCC specs for both conducted and radiated interference at full output level External UL listed power transformer with 6 ft. twin lead wire Line transient protection Compact size for minimum mounting space Mounting holes spaced to fit standard equipment rack rail Description The Blonder-Tongue ACA is a broadband indoor distribution amplifier designed specifically for CATV and SMATV RF distribution systems which use a "cable drop" as a signal source. Two models are available: the 5430 with 40 to 300 MHz bandpass, and the 5440 with 40 to 450 MHz bandpass. Both are designed for apartment complex applications. The ACA has a flat operating gain of 30 dB which can be adjusted down to 22 dB with the variable attenuator. Gain and slope controls are located on the front panel for easy set-up and adjustment. A push-pull hybrid IC module enables the ACA to operate at high output levels while retaining low distortion characteristics. The aluminum chassis is designed to provide excellent heat dissipation, thus allowing operation at high ambient temperatures with no degradation of performance or reliability.

Hum modulation Radiation suppression

No. of channels Output level (dBmV) Lowest ch. Highest ch. Composite triple beat distortion (dB) Cross mod. (dB) 2nd order (dB)

5430 12

35

5440 35

60

58 63

48 53

48 53

43 48

-59 -59 -70

-59 -59 -70

-59 -60 -77

-60 -61 -78

Power requirement (Amps, RMS)

117 VAC, 60 Hz: 0.25 24 VAC, 60 Hz: 0.65

Operational temperature range 0F to +140F Size Weight (shipping) 2" x 5-3/8" x 5-5/8" 2.9 lbs.

Ordering Information Order No.


B-T 092533 B-T 146523

Mfg. No.
5440,ACA-30-450 5450 ACA-30-550

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

H70

S-ar putea să vă placă și