Sunteți pe pagina 1din 73

Hardware (OSN 3500)

OSN3500
Huawei OSN

NGSDH series

stands for Optical Switch Node (support ASON)

Intelligent

OSN 3500 Intelligent Features



Service level agreement (SLA) Topology automatic discovery function Automatic end-to-end service configuration Support mesh networking and protection
Traffic engineering Supports RPR

Sub rack with Boards (OSN3500)

Cabinet Indicators

Subrack

Slot Access Capacity

Continue

Continue

System Architecture

10

Board Appearance and Dimensions

11

Functions of SL64

12

Optical Port Parameters

13

SDH Boards

14

Continue

15

Slots for SL64 & SF64

16

PDH Boards with Slot Allocation

17

Continue

18

PDH Board Function

19

Alarms

20

Ethernet Boards

21

Ethernet Boards Slots

22

Functions

23

Features of EFS4

Supports bandwidth auto-sensing Supports MPLS Supports LCAS Supports Port based flow control Supports receiving and transmitting Ethernet testing frame Supports inloop at Ethernet port and inloop and outloop at VC3 level Supports port level Ethernet performance monitoring Supports EPL/EPLAN/EVPL/EVPLAN services and QoS

24

Indicators

25

Continue

26

Ethernet Board Indicators

27

Ethernet Unit Alarms

28

Cross Connect & SCC Boards

29

Capacity of Cross Connect Boards

30

Cross Connect Unit Functions

31

GSCC


32

Support NE ID setting by software Supports 1+1 hot backup Supports 40 DCC Processes Order-wire bytes Controls cabinet indicators and intelligent fans Collects and monitors alarms and performance events Monitors power supply Supports ASON intelligent function Inserted in slot 18 (Active) and/or Slot 17 (Standby

SCC Unit Functions

33

SCC Databases

34

Summary

35

Continue

36

Continue

37

Equipment and Network Protection

38

TPS Protection

39

Working Protection Relationship

40

Ethernet Board Protection

41

Equipment Protection Slots

42

Equipment Protection Summary

43

Network Protection Summary

44

ETHERNET SERVICES OVER NGSDH

45

Basic Concepts
Port

External physical port of Ethernet unit, the common rates of external port are 10M, FE, GE and 10GE; VC Trunk Virtual Container Trunk, VC Trunk is built by VC. It is the internal port of Ethernet unit.

46

Continue

47

Tag Attributes

Tag flag is used to identify the type of frames. Three types of Tag attributes are available: Tag aware Access Hybrid

48

Continue

Tag Aware: When the port is set to be Tag aware, the port transmits the packets with the Tag flag transparently and discards those without the Tag flag; Access: When the port is set to be Access, the port attaches a Tag flag to the packets without Tag flag according to its VLAN ID and discards those with the Tag flag; Hybrid: When the port is set to be Hybrid, the port can process packets regardless of the Tag flag and attach a Tag flag to the packets without the Tag flag according to its VLAN ID.
49

Continue

50

Ethernet Services

E-Line EPL EVPL ELAN

51

E-Line

Ethernet service that is based on a Point-to-Point Ethernet Connection An E-Line Service type can be used to create a broad range of point-to-point services E-Line Service type may be between two different speed Customers Service Multiplexing (sharing) MAY occur at Ports and/or VC Trunks

52

Continue

E-Line Service used to create Ethernet Private Lines Virtual Private Lines

Carrier Ethernet Network

53

EPL

Bandwidth exclusive Services isolated No sharing Replaces a TDM Private line Dedicated VCTrunks and Ports for Point-to-Point connections The most popular Ethernet service due to its simplicity

54

Continue

55

EVPL
Ethernet Virtual Private Line (EVPL)

Supports sharing of multiple VC Trunks and/or Ports

Allows

single

physical

connection/Port

to

accommodate different customer traffic

ISP bandwidth utilization ratio and save Improve the POP

the ports resource of Ethernet Unit

56

Port Shared EVPL

57

VC Trunk Shared EVPL

58

Challenge!
What

about if Different customers data with same VLANID?

59

MPLS Basics

60

MPLS

Multi-protocol Label Switching, standard routing and switching platform; Tunnel/VC: Two labels in MPLS, range of value is 16(220-1) LSP: Label switching path, different value labels will be given in different nodes, data can be sent forward according these labels P/PE: P (Provider) internal node of MPLS network, PE (Provider Edge) the edge of MPLS network

61

EVPL (MPLS)

62

Q in Q

QinQ technology is a VLAN stacking technology C-VLAN S-VLAN Advantages of QinQ technology: Expands VLAN and alleviates VLAN resource insufficiency; Extends LAN service to WAN, connecting the client network to the carrier network and supporting transparent transmission

63

EVPL (Qin Q)

64

Ethernet Service Types : E-LAN


E-LAN Service used to create

Multipoint to Multipoint Transparent LAN Service Foundation for IPTV and Multicast networks etc.
Carrier Ethernet Network

65

Ethernet LAN (E-LAN) Service Type

Multipoint-to-Multipoint Ethernet Virtual Connection Service Multiplexing sharing MAY occur at none, one or more of the VC Trunks/Ports

66

Services Using E-LAN Service Type

Ethernet Private LAN (EP-LAN) Ethernet Virtual Private LAN (EVP-LAN) Supports dedicated or Shared services Supports transparent LAN services multipoint Layer 2 VPNs

and

67

EPLAN

68

VB/LP

69

EVPLAN
Bandwidth
Services

sharing by different users are differentiated by different

schemes IEEE 802.1q Bridge IEEE 802.1ad Bridge

70

IEEE 802.1q Bridge


Performs Layer 2 Switching According to Destination MAC address and VLANIDs

71

IEEE 802.1ad Bridge


Performs Layer 2 Switching According to Destination MAC address and S-VLANIDs

72

Thank You

73

S-ar putea să vă placă și