Documente Academic
Documente Profesional
Documente Cultură
FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Telephone : Fax : 0798-65-2111 0798-65-4200
Printed in Japan
*00080891000* *00080891000*
*00080891000*
*IME23660P60* *IME23660P60*
*IME23660P60*
SAFETY INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. Turn off the power at the switchboard before beginning the installation. Fire or electrical shock can result if the power is left on. Do not install the equipment where it may get wet from rain or water splash. Water in the equipment can result in fire, electrical shock or equipment damage. Be sure no water leaks in at the transducer mounting location. Water leakage can sink the vessel. Also confirm that the transducer will not loosen by ships vibration. The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation. Be sure that the power supply is compatible with the voltage rating of the equipment. Connection of an incorrect power supply can cause fire or equipment damage. The voltage rating of the equipment appears on the label above the power connector.
CAUTION
Observe the following compass safe distances to prevent deviation of a magnetic compass:
Standard compass Display unit Distribution Box Matching Box Transducer Switch Box (option) Junction Box (option) Digital depth indicator (option) 0.50 m Steering compass 0.40 m
1.90 m
1.15 m
0.50 m 1.00 m
0.40 m 0.60 m
0.30 m
0.30 m
0.50 m
0.40 m
When handling the transducer cable, keep in mind following points. Keep the cable away from oil and fuel. Keep the cable away from the place where it may be damaged during the installation. Do not paint the cable. The sheath of the transducer cable is made of chlorophrene rubber (or vinyl chloride). Therefore, do not paint the sheath with organic liquid (such as toluene) since it may harm the sheath.
EQUIPMENT LISTS
Standard Supply
Name Display Unit Distribution Box Matching Box Transducer Transducer Tank Spare Parts Installation Materials Type FE-701 FE-702 MB-502 MB-504 50B-6B 200B-8B TTF-5600 TTF-2000 SP02-04101 CP02-06301 Code no. 000-013-602 000-013-604 000-015-586 000-015-587 001-228-890 001-228-950 Qty 1 1 1 1 1 1 set 1 set For 50B-6B For 200B-8B w/15 m or 30 m cable w/15 m, 30 m or 50 m cable For 50B-6B For 200B-8B For distribution box For distribution box Remarks w/Installation Materials CP02-06400 (000-015-872) and Accessories FP02-04800 (000-015-469)
Optional Supply
Name Type Code no. 000-012-179 000-012-176 Transducer Switch Box EX-8 000-012-183 000-012-182 000-012-180 000-012-181 000-143-821 000-804-877 000-015-877 000-015-878 000-015-885 000-015-887 001-229-270 001-229-280 001-229-290 001-229-300 001-229-310 001-229-320 001-229-090 1 Qty Remarks Flush mount, color specified Bulkhead mount, color specified 7.5BG7/2, Flush mount 7.5BG7/2, Bulkhead mount N.G, Flush mount N.G, Bulkhead mount 2 m cable w/ a 6P connector For EX-8 For 50B-6B For 200B-8B For 50B-6B (w/Flange) For 200B-8B (w/Flange) 2.5GY5/1.5 7.5BG7/2 N3.0 2.5GY5/1.5 7.5BG7/2 For Windows 95/98/NT4.0 w/Installation Materials CP02-06700 (000-029-068) Spare Parts SP65-00601 (002-889-730) Accessories FP65-00400 (000-029-067)
Cable Assy.
FM-C6FPS003020 JUNCTION Box JIS F8821-1MO 0-20A3P TTF-5001 TTF-2001 Transducer Tank TTF-5002 TTF-2002 OP02-78-1 Bulkhead Kit OP02-78-2 OP02-79-1 Flush Mount Kit (F) OP02-79-2 OP02-79-3 Flush Mount Kit (S) OP02-80 Data Recording 02-522-990 Software for PC Digital Depth Indicator
1 1
1 1 1 1 1
FE-720
000-029-025
1 set
ii
MF-22L-1-100V MF-22L-1-200V Dimmer MF-22L-2-100V MF-22L-2-200V Terminal Box EGC Printer Gate Valve DS-802 PP-505-FE GV-50B-6B GV-200B-8B
000-069-401 000-069-403 1 000-069-402 000-069-404 000-029-064 000-055-892 000-015-265 000-015-273 1 set 1 set 1
100 VAC-120 VAC, Flush mount type 200 VAC-240 VAC, Flush mount type 100 VAC-120 VAC, Bulk head type 200 VAC-240 VAC, Bulk head type With Installation Materials CP65-00903 (000-029-064) With Installation Materials CP02-07601 (002-891-620)
iii
SYSTEM CONFIGURATION
DISPLAY UNIT FE-701
DIGITAL DEPTH INDICATOR FE-720 Navigation Device Navigation Device Personal Computer Printer DIMMER
IEC 61162-1
CONTACT CLOSURE
JB
JB
JB
JUNCTION BOX JIS F8821-1 0-20A3P MATCHING BOX MB-502 (for 50B-6B) MB-504 (for 200B-8B)
TRANSDUCER
: Local Supply
iv
1. MOUNTING
1.1 Category of Equipment
Equipment for protected area
Display Unit Distribution Box Matching Box Transducer Switch Box (option) Digital Depth Indicator (option)
Equipment to be submerged
Transducer
Cover Desktop
Overhead
Dummy cover
1.2.4
Flush mounting
There are two types of flush mount kits, F type and S type. For details, see the outline diagrams at the back of this manual.
F type
Flush Mount Kit (F): OP02-79-1 (001-229-290) OP02-79-2 (001-229-300) OP02-79-3 (001-229-310) Type Code no. 100-279-270 1 2 3 Cosmetic panel 02-129-1041-0 Hex bolt Spring washer M6X12 M6 100-279-280 100-279-290 000-862-127 000-864-260 4 4 1 Qty Remarks OP02-79-1:N3.0 OP02-79-2:2.5GY5/1.5 OP02-79-3:7.5GY7/2
No. Name
1. 2. 3.
Prepare a cutout in the mounting location whose dimensions are 210 (W) X 194 (H) mm. Attach the cosmetic panel (02-129-1041-0) to the display unit with four hex bolts (M6X12) and four spring washers (M6). Fix the display unit to the mounting location with four tapping screws (5X20).
S type
Flush Mount Kit (S): No. Name 1 2 3 4 5 Fixing plate Wing bolt Hex bolt Spring washer Wing nut OP02-80 (001-229-320) Type 02-129-1045-0 M4X30 M6X12 M6 M4 Code no. 100-279-300 000-804-799 000-862-127 000-864-260 000-863-306 Qty 2 6 4 4 6 Remarks
1. 2. 3. 4. 5.
Prepare a cutout in the mounting location whose dimensions are 194 X 194 mm. Insert the display unit to the cutout. Attach two fixing plates (02-129-1045-0) to the display unit with four hex bolts (M6X12) and spring four washers (M6). Screw six wing bolts (M4X30) to wing nuts (M4). Fasten the display unit with six wing bolts and nuts.
1.3 Transducer
The installation of the transducer and the tank should be accomplished by a dockyard referring to the installation drawings at the back of this manual. An example of transducer installation method is also shown in paragraph 1.3.2.
Note: Discussions should take place and agreement reached with the dockyard for sufficient reinforcement and watertightness of the hull to comply with the regulations concerned.
7. It is recommended to enclose the transducer cable in a conduit pipe for waterproofness and electrical shielding as well as for protecting the cable from mechanical damage. The conduit pipe should be fixed to the flange on the transducer tank. The pipe should be of such a length to clear the water level when the ship is fully loaded. The pipe end should be finished with filling compound. It is recommended to fill the pipe with sand between the transducer and the junction box (or matching box). This will protect the transducer from vibration and damage.
115 90 4- 15 FIXING HOLE SGP 11/4" JIS B2221 5 -32
K
1 2 3 4 5 6 7 8
Transducer (50B-6B) Transducer Tank Fixing Flange Gland Nut Washer Rubber Gasket Hex. Bolt (M6x25) Spring Washer (For M6)
59
154
*Sea water comes into the area marked with "*" inside the tank.
HULL PLATE
Fasten the matching box with four Trapping screws (6x20: local supply). Compass safe distances are as follows; standard compass: 0.50 m, Steering compass: 0.40 m.
1. Fasten the hanger with four tapping screws (5x20). 2. Fasten the digital depth indicator to the hanger with two knobs.
Tabletop
Overhead
Flush mounting
There are two types of flush mount kits, F type and S type. For details, see the outline diagrams at the back of this manual.
F type
Use the accessories FP65-00401 (See page A-3).
1. Prepare a cutout in the mounting location whose dimensions are 183 (W) X 92 (H) mm. 2. Attach the cosmetic panel (20-016-1051) to the indicator with Two hex bolts (M6X12) and two spring washers (M6). 3. Fix the indicator to the mounting location with four tapping screws (5X20).
S type
Use the accessories FP65-00402 (See page A-3).
1. Prepare a cutout in the mounting location whose dimensions are 167 (w) X 92 (H) mm. 2. Insert the indicator to the cutout. 3. Attach two fixing plates (20-007-2401) to the indicator with two hex bolts (M6X12) and two spring washers (M6). 4. Screw four wing bolts (M4X30) to wing nuts (M4). 5. Fasten the indicator with four wing bolts and nuts.
1. Disassemble the gate valve assembled tentatively: spacer, gasket1, gate valve, gasket 2, O-ring (P170), seachest cap and shaft assembly. When assembling the gate valve, use original washers, bolts and nuts. Keep the bottom of the seachest cap and the shaft free of dust and be careful not to damage them.
BOLT SHAFT
SCALE
SEACHEST CAP
O-RING (P135)
O-RING (P170)
GASKET2 SPACER
2. Weld the spacer to the hull bottom. The hull side of the spacer should be flush with the hull bottom. Be careful not to damage the side fixed to the gate valve. 3. Clean the side of the spacer to be fixed to the gate valve. 4. Grease (supplied) both sides of the gasket 1 and the inner side of the spacer. Place the gasket 1 onto the spacer. 5. Clean the flange side of the gate valve, and place it on the gasket 1. The scale side of the gate valve should be up. 6. Fix stud bolts with washers and bolts loosely. 7. Keep seachest cap and shaft assembly free of dirt and dust.
8. Grease O-ring (P170) and seachest cap lightly, and attach O-ring (P170) and gasket 2 to the bottom of seachest cap. O-ring (P170) and gasket 2 are attached by adhesion of grease. 9. Place the assembly made at step 8 on the gate valve. 10. Fix the assembly with bolts, nuts and washers loosely. 11. Unscrew nuts from flange 2, and confirm that shaft can be moved up and down smoothly by hand. You will feel some resistance because of the O-ring (P135). (See the illustration on the previous page.)
Nut
Washer
Flange 2
12. Fasten the gate valve with bolts, nuts and washers above and below. NOTE) When installing a transducer, do it before step 7 or after removing the seachest cap and the shaft assembly.
10
2. WIRING
Wiring
Connect three cable assemblies (supplied) between the display unit and distribution box.
Display unit FE-701 (rear panel)
MJ-A3SPF0015-100
POWER XDR
FM-C6FPS002-100
DATA
2.0 sq
MJ-A10SPF0002-100
TTYCYS-4
Terminal Box
1.25 sq
MJ-A7SPF0009-020
2.0 sq
Alarm system
DPYCYS-2.5
Matching box
TB1 TB2
1a 1T 2a 2T 3a 3T
Transducer TB4
TB1
12345678910
TB2
12
TB3
12345678910
12345
11
When the Transducer Switch Box EX-8 is used, the interconnection diagram is as follows.
Display unit FE-701 (rear panel)
MJ-A3SPF0015-100
POWER XDR
FM-C6FPS003-020
DATA
2.0 sq
MJ-A10SPF0002-100
TTYCYS-4
Terminal Box
Ground
1.25 sq
MJ-A7SPF0009-020
Alarm system
2.0 sq
TB1
1 2 3
RECORDER TB2
1 2 3
2.0 sq
FORE
AFT
Ground
Matching box
TB1 TB2
1a 1T 2a 2T
Matching box
TB1 TB2
1a 1T 2a 2T 3a 3T
TB7
3a 3T
2RNCT-SB 2CX2.5
TB1
12345678910
TB2
12
TB3
12345678910
Transducer FORE
Transducer AFT
PC IEC TTYCYS-4 61162-1 TTYCYS-4 TPYCYS-1.5 Power TTYCYS-4 Sours for FE-701
12
50mm Armor
40mm 100mm
Fold back shield over on vinyl sheath. Vinyl Sheath Shield Cores
Armor
Taping
Vinyl Sheath
Others
Crimp-on lug FV1.25-3 Red
Fabrication of cables
13
Several cables are required to supply at local. In this manual, JIS (Japan Industrial Standard ) cables are specified. Use equipment cables refering to the figures below. Shield
Sheath Armor
Vinyl sheath
Vinyl sheath
Vinyl sheath
14
50mm
40mm 100mm
Armor
Armor
Taping
Vinyl Sheath
Clamp here.
2 Rotate
Shield
Special tool for connecting wires, fitted inside the Distribution Box
Armor
Conductor
Vinyl sheath
2
1 3
Insert
S =0.75 mm =1.11 mm
Anticorrosive sheath
(Sectional view)
Terminal Board TB1, TB3 Cross section
15
Display unit
EMI core
To distribution box
Transducer
Connect the transducer cable to the distribution box. If necessary, attach the junction box between the distribution box and matching box.
Ground
Connect the ground wire (2.0 sq.) from both the display unit and distribution box to ships ground to prevent interference to the picture. Shorten the ground wire as much as possible. The optional digital depth indicator FE-720 should be grounded by 1.25 sq. wire. Note 1: Ground the equipment to prevent mutual interference. Note 2: Use closed-type lugs (supplied) to make the ground connection at the display unit and distribution box. Do not use an open-type lugs.
16
MJ-A7SPF0009-020 TB3 TD1-A TD1-B 24V 0V GND TD1-A TD1-B 24V 0V GND 1 2 3 4 5 6 7 8 9 10 TTYCYS-4 1 2 3 4 5 6 7 8 WHITE BLUE YELLOW GREEN RED BLACK
IN/OUT <1< <2< <3< <4< <5< <6< TD-A TD-B RD-A RD-B 24V 0V
17
Case2: Silencing the alarm from the digital depth indicator FE-720
When the main display unit FE-701 activates an alarm, it can be deactivated at the FE-701 itself and also, it can be deactivated from the digital depth indicator FE-720. To do this, connect as follows.
Connection
DISTRIBUTION BOX FE-702
TB1 1 MJ-A7SPF0009-020 6 TD1-A 7 TD1-B 8 RD1-A 9 RD1-B 10 TTYCYS-4 1 2 3 4 5 6 7 8 WHITE BLUE YELLOW GREEN RED BLACK IN/OUT <1< <2< <3< <4< <5< <6< TD-A TD-B RD-A RD-B 24V 0V
FE-720 setting
In the menu of the FE-720, ALARM should be set to ON. If an alarm activates, press any key on the FE-720, then the alarm will be deactivated at the FE-701 and FE-720.
MENU DIM CONTROL LANGUAGE CONTRAST ALARM TEST PANEL ONLY ENGLISH ON
18
100-115 VAC
Terminal location on TB7 1 2 Color of cable from T1 Black Orange
19
J1 TB5 TB6
J4
J3
J2
CONE Board
20
4. ADJUSTMENTS
This section provides the procedures for initial set up of the equipment. The type of transducer used should be properly set before operating the equipment.
4.1
Transducer Setting
Select the type of transducer used as follows. 1. Press the POWER Switch while pressing any key. Release the key when the following display appears.
EXTENSION MODE +: TRANSDUCER SETTING -: TEST : CLEAR MEMORY : DEMONSTRATION SELECT MODE
3. Set as follows by using [] or [] to select an item and [+] or [-] to set option. a) If only one transducer is installed, set XDR FORE field to 50 kHz or 200 kHz, according to actual installation. Leave the XDR AFT field as N/A.
b) If two transducers are installed via the switch box EX-8, set XDR FORE field and XDR AFT field to 50 kHz or 200 kHz, according to actual installation.
Note: The default settings in the TRANSDUCER SETTING window are N/A. At the first power-up after installation, the window appears to set transducer(s).
21
4.2
1.
2.
22
FE-720/HK
DESCRIPTION/CODE OUTLINE M4 YBSC2 MBNI2 DESCRIPTION/CODE FE-720 1 000-863-306 WING NUT Q'TY NAME Q'TY 4
02FI-X-9852-4
1/1
NAME
OUTLINE
UNIT
+ 2 TAPPING SCREW
ACCESSORIES
FP65-00403
5X20 SUS304 1 4
M6X12 SUS304
ACCESSORIES
FP65-00401
HEX.BOLT(SLOTTED HEAD) 000-862-127 M6 SUS304 2 CRIMP-ON LUG 000-864-260 20-016-1051-0 1 MJ 100-251-370 CABLE ASSY.
000-802-840
INSTALLATION MATERIALS
CP65-00801
FV0.5-4 (YEL) 20 000-107-268
SPRING WASHER
COSMETIC PANEL
ACCESSORIES
FP65-00402
000-144-235 MJ-A7SPF0009-020
1 000-145-612
SPRING WASHER
A-3
C2366-Z02-D
D-3a
D-13
Y. Hatai
D-14
Y. Hatai
D-15
Y. Hatai
D-16
Takahashi.T
D-17
Y. Hatai
D-18
Y. Hatai
S-1
1 2 3 4 5 6
ALARM RELAY NORMAL CLOSE/OPEN PC (EIA-232C) PP-505-FE PRINTER DEPTH INDICATOR *6 FE-720 OR NAV EQUIPMENT IEC61162-1
*1 DPYCYS-1.5 *1 TPYCYS-1.5
1 2 3 4 5 6 7 8 9 10
TB1 NORMAL CLOSE NORMAL OPEN RELAY COMMON EIA232-TD EIA232-RD GND TD1-A TD1-B RD1-A RD1-B TB3 TD1-A TD1-B 24V 0V GND TD1-A TD1-B 24V 0V GND
POWER J1 (+) (-) SHIELD DATA J2 TD2 RD2 GND TD1-A TD1-B RD1-A RD1-B DP-ON RELAY SHIELD
B
*1 DPYCYS-1.5
1 2 3 4 5 6 7 8 9 10
J1 RD2 TD2 GND TD1-A TD1-B RD1-A RD1-B DP-ON RELAY SHIELD
MJ-A10SPF0002,10m,9.0
24 VDC
5 4 3 2 1
*1 DPYCYS-2.5
TB3
*1 DPYCYS-1.5
1 2 3 4 5 FORE XDR
TB1
1 2 3
TB2
1 2 3 *1 IV-2sq.
*1 IV-2sq.
*1 DPYCYS-2.5
*4
*1
J.B
1 2 3
AFT XDR
DPYCYS-2.5 *1 *4
1 2 3
1 2 3
J.B *1
DPYCYS-2.5 *1
1a 2a 3a 1T 2T 3T TB2
TB1
400m 200kHz 50kHz FE-720 NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. CABLE LENGTH BETWEEN DISTRIBUTION BOX AND MATCHING BOX IS WITHIN 400 m. *5. TRANSMITTING FREQUENCY IS SET TO 200 kHz AT FACTORY. WHEN 50 kHz IS USED, SELECT THE SETTING FROM MENU. *6. REFER TO FE-720 INTERCONNECTION DIAGRAM FOR DETAIL.
TB2
TB1
*5 TRANSDUCER
*5 TRANSDUCER 2 USE A SWITCH BOX EX-8 WHEN TWO TRANSDUCERS ARE INSTALLED.
DRAWN Feb. 14 '06 CHECKED Feb. 14 '06 APPROVED Feb. 21 '06 SCALE DWG.No.
T.TAKENO T.YAMASAKI
T.Matsuguchi
MASS kg
TITLE
NAME
C2366-C01- K
1 2
A
*1 TTYCYS-4,30m MAX.
TB1 NORMAL CLOSE 1 NORMAL OPEN 2 RELAY COMMON 3 EIA232-TD 4 EIA232-RD 5 GND 6 TD1-A 7 TD1-B 8 RD1-A 9 RD1-B 10 24VDC *1 DPYC-1.5 7 8 1 2 3 4 5 6 MJ-A6SPF0003,2m WHT BLK *3 MJ-A6SPF DPYC-1.5 *1 1 2 3 4 5 6 1 2 3 4 5 6 7 TD-B RD-A RD-B +24V 0V SHIELD J6 DIM-P GND GND NC NC NC *1 IV-1.25sq. MJ-A7SPF0009,2m WHT BLU YEL GRN RED FUSE(1A) BLK
*1 IV-2sq.
*1 TTYCYS-4
*4
U V L
B
*1 TTYCYS-4,30m MAX.
*3 MJ-A7SPF
TB3 TD1-A 1 TD1-B 2 +24V 3 0V 4 GND 5 TD1-A 6 TD1-B 7 +24V 8 0V 9 GND 10 1 2 3 4 5 6 *1 DPYC-1.5 7 8 DIMMER *2 MF22L-1/2 -100V U V L DIMMER MF22L-1/2-200V
3k
MJ-A7SPF0009,2m WHT BLU YEL GRN RED FUSE(1A) BLK MJ-A6SPF0003,2m WHT BLK
*3 MJ-A6SPF
1 2 3 4 5 6 7
*1 IV-2sq. *1 IV-2sq.
1 2 3 4 5 6
*4
U V L
C
DRAWN
200V3k
TITLE
FE-720
S-2
NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. REMOVE RESISTANCE 3k FOR USING 200V SET.
Feb. 14 '06 T.TAKENO CHECKED Feb. 14 '06 T.YAMASAKI APPROVED Feb. 21 '06 T.Matsuguchi FE-700 MASS SCALE kg DWG.No. REF.No.
NAME
INTERCONNECTION DIAGRAM
1 2
A
FE-702
FM14-7P RXD (H) TXD (H) 0V TXD (C) RXD (C) +12V N.C. *3 1 2 3 4 5 6 7 4 EIA232-TD 5 EIA232-RD 6 GND *1 TPYCYS-1.5 (max.10m) TB1
PRINTER
DISTRIBUTION BOX
PP-505-FE
12-32 VDC
08S0157,3m
*2 FM14-2P
B
08S0087,2m
1 2
+ -
*1 IV-2sq.
C
DRAWN
TITLE
PP-505-FE
FE-700
NAME
NOTE *1: SHIPYARD SUPPLY *2: FITTED AT FACTORY *3: GROUND THRU CONNECTOR CLAMP.
DWG.No.
Feb. 14 '06 T.TAKENO CHECKED Feb. 14 '06 T.YAMASAKI APPROVED Feb. 21 '06 T.Matsuguchi SCALE MASS
C2366-C03- D
REF.No.
S-3
16-006-3022-0