Sunteți pe pagina 1din 2

TR-73U

Three Channel Data Logger


Temperature, Humidity and Ambient Pressure

The TR-73U has all the great features of TandDs TR-72U temperature and humidity data logger plus a third channel for monitoring and recording ambient pressure. This compact unit has a large 4 digit LCD display for reading current values that can be set to show any single channel, or all three on a rotating basis. The logger can store up to 8,000 sample triplets, operates on a single AA battery and incorporates a USB interface for rapid data downloading. As with all of TandDs data loggers, the TR-73U ships complete with software, sensor and cable included.

T&D Corporation

Product Specifications
TR-73U Measurement Parameter Measurement Channel Internal Sensor Standard External Sensor Optional External Sensor Measurement Accuracy Display Resolution Sensor Type Internal Sensor Time Constant Recording Interval Recording Capacity Recording Mode LCD Display Power Battery Life Data Back-up Communication Interface Data Download Time Dimensions Weight Operating Environment Standard Sensor (Included) Accessories included in package Temperature 1 Channel -10 to 60C 0 to 50C -40 to 110C 0.3% (0 to 50C) 0.5% (-40 to -20 / 80 to 110C) 0.1C Thermistor 12 Sec. Humidity 1 Channel --10 to 95% RH --5% RH (25C, 50% RH) 1% RH Macromolecular --8,000 Readings 2 or 3 Channels Endless Loop Method (Overwrite from the oldest data when recording capacity is full) One Time Method (Stop recording when recording capacity is full) Measurements, (Any Single Channel or alternating display of all Channels), Recording Status, Battery Life Warning, Amount of Recorded Data, Unit of Measurement AA alkaline battery (LR6) Approx. 1 year **2 Activated when battery power is low or when switch is off (Approx. 1 year) USB Communication Cable (included) Approximately 8 seconds (For full memory) H55mm W78mm D18mm About 62g (Including one AA battery) -10 to 60C, 90% RH (non-condensing) TR-3100 External Temperature & Humidity Sensor AA alkaline Battery (LR6), User's Manual, USB Cable (US-15C ; length 1.5m), Software CD Set 0.1 hPa Atmospheric Pressure Sensor 4 Sec. **1 1, 2, 5, 10, 15, 20, 30 Seconds / 1, 2, 5, 10, 15, 20, 30, 60 Minutes- Total of 15 choices Pressure 1 Channel 750 to 1100 hPa ----1.5% hPa

Software Specifications
Software Compatible Devices Communication Functions Temp/Humidity Graph Graph Display Data Display T&D Recorder for Windows TR-71U TR-72U TR-73U Recording Start (Programmed Start / Immediate Start) Recording Stop Main Unit Settings (Recording Interval Recording Method Upper and Lower Limits) Downloading of Recorded Data Temperature and Humidity Graphs for each Channel Zoom in, out and scroll with mouse or keyboard Change Channel Colors Turn ON and OFF Channel Display Channel Name Recording Interval Number of Readings Highest, Lowest and Average Readings Unit of Measurement. AB Cursor Dates, Times and Data Readings Calculated Difference between Cursor A and B Number of Channels Others 8 Channel Simultaneous Display and Processing Possible to process mixed data from TR-71U and TR-72U units. (up to 4units.) Data List Display Calculation Range Settings Data Maintenance Edit Recording Conditions Delete Data by Channel Re-order Data by Channel Other File Output Printing Compatible OS Serial Port Auto Find Function T&D Common Data File Text File (CSV, etc) (Selected Range or File for Entire Period) Graphs / Tables Microsoft Windows 2000 / XP English Microsoft Windows 98 / Me English Microsoft WindowsNT 4.0 English **1 PC/CPU Memory Hard Disk Monitor IBM Compatible with higher than Pentium 90MHz USB Port (1.0 / 1.1) More than 16MB More than 4 MB of free space (Data will need more space) VGA (640 480) more than 256 colors

**1 Pressure time constant is 40 seconds for sample rates of one minute or longer. **2 Battery life of TR-73U is approximately 10 months.

**1: USB communication with TR-71U / 72U data loggers cannot be carried out using WindowsNT4.0.

(1)

(2)

(3)

(4)

(5)

Easy to Read Multi-Functional Display


The easy to read LCD displays current readings, recording condition, battery life warning, and unit of measurement. (1) Recording condition: ON:Recording in progress. BLINKING:Waiting for programmed start. (2) Memory status: After every 2000 readings the scale will increment from left to right. (3) Data communication. ON: USB cable is connected. BLINKING: Data is being transferred. (4) ONTIME:When the number of recorded readings reaches 8000, "FULL"will appear in the unit's LCD display and recording will automatically stop. ENDLESS:When the number of recorded readings reaches 8000, the oldest data reading will be overwritten and recording will continue. (5) When the battery power becomes low, this will appear in the LCD display. If the battery power becomes even lower, SLP will appear and normal operations will stop. If the signal appears, please change the battery as soon as possible. (6) The unit of measurement (C, F, %, hPa) for the display will appear. (7) Current measurements or operational messages such as FULL or SLP will appear.

(6)

(7)

System Setup
Standard Humidity and Temperature Sensor (TR-3100) AA Alkaline battery LR6 x 1 Software (T&D Recorder for Windows)

Insert

Install

Output
USB Communication Cable US-15C

Text File

TR-73U

Connect

Connect

Printout

Product information, FAQ and software update downloads.

Web Site T&D Online

http://www.tandd.com/

5652-169 Sasaga Matsumoto City. Nagano 399-0033 Japan Facsimile(+81)263-26-4281 E-mail: overseas@tandd.co.jp

T&D Corporation

TandD US, LLC.

Phone: (518) 669-9227 Fax: (413) 639-9227 E-mail: inquiries@tandd.com