The Complete Solution for Remote Connection to Programmable Controllers and Control Networks Dialup Programming Alphanumeric Paging AutoDialer Supervisory Control and Data Acquisition
Remote Access Dial-in Modem Kits Remote Access Dial-in Modem Kits are designed for easy installation and configuration of dialup communications. Each kit comes complete with everything you need to establish a dial-up connection to your Allen-Bradley control system. Remote Access Dial-in modems are ideal for remotely supporting your control system. You can minimize support costs by remotely dialing in for: Online Programming Uploading/Downloading Processor and MMI Programs Updating Processor and MMI Firmware Monitoring Data Table Values Real-time Collecting Data Checking System Status
Remote Access Paging Modem Kits Remote Access Paging Modem Kits offer all of the features of our dial-in kits plus the added capability of alphanumeric paging. Remote Access Paging Modems allow even the simplest control system to forward alarm conditions and system status messages to most alphanumeric pagers. Additional features include: 250 Alarm Triggers from Binary or Integer Files 250 User-defined Text Messages Multi-pager Support (up to 16 users) Text Messages up to 100 Characters Integer File Variables Embedded into Alarm Text Internet-based Text Pager Services* Such as Text (processor alarm) Forwarding to E-mail, Fax, Voice Synthesis and Operator Dispatch. System Diagnostic Pages
* Check with your alphanumeric pager provider for available services
www.ab.com/networks/remote_access
Product Profile
Direct Connect to Enhanced PLC-5: Connection through the Channel 0 DF1 Comm Port of the PLC-5 enhanced processor. Enhanced processors include all PLC-5 processors.
Supported Software: RSLogix 500, Al 5, 6200 PLC-5 Order Kit #: 1747-CHORAD
Programming PC
PLC-5 Channel 0
Data Highway Plus Connection: through the 1770-KF2 module. Enables user to go on-line with a PLC-5 or SLC 5/04 controller over the Data Highway Plus network.
Supported Software: RSLogix 500, RSLogix 5, Al 500, Al 5, 6200 PLC-5 Order Kit #: 1770-KF2RAD 1700-KF2 Programming PC
Direct Connect to SLC 5/03, SLC 5/04, SLC 5/05: Enables user to go on-line with an SLC processor through DF1 Channel 0. As shown, the SLC 5/04 can be configured to enable pass thru over to the DH+ Network.
SupportedSoftware: RSLogix 500, Al 500 Order Kit #: 1747-CHORAD
Programming PC
Direct Connect to MicroLogic 100/1200/1500: Enables user to go on-line with MicroLogix processor through DF1 Channel 0.
Supported Software: RSLogix 500 Order Kit #: 1761-MICRORAD (For 1769-LRP, use 1747-CHORAD)
Programming PC
1747-KE Connection
Programming PC
MicroLogix Channel 0
Programming Computer
PLC-5
Paging Modem
Remote Access Paging Modem Kits provide the ability to monitor alarm conditions in an A-B control process and have alarm information sent to an alphanumeric pager. Remote Access Paging Modems support: Enhanced PLC -5, SLC 5/03, 5/04, 5/05, MicroLogix 1000, 1200 or 1500 processors. Each kit contains Microsoft Windows based Remote Access Paging Modem configuration software. This software configures the Remote Access Paging Modem communications between your Allen-Bradley Controller and your Alphanumeric Pager Service Provider. The Remote Access Paging Modem Configuration software allows you to custom configure address books of people to receive pages, up to 250 alarm triggers (Binary or Integer), and up to 100 characters of alphanumeric message text per alarm with your choice of Integer File variables embedded in the text messages. For example, a critical alarm temperature condition is present in a control process. An alarm condition generated by a Remote Access Paging Modem can be displayed on a alphanumeric pager as:Tank # 7 is over temperature Current temp is 100 degrees Celsius. In the alphanumeric page, the alarm text is Tank # {N7:10} is over temperature Current temp is {N10:5} degrees Celsius. The variables 7 {N7:10} and 100 {N10:5} where embedded into the alarm text. These variables ( 7 and 100) are integer file values. Remote Access Paging Modem Kits also provide the ability to quickly and easily remotely program Allen-Bradley controllers.
Dial-in
1770-KF2RAD1 Connect to DH+Network Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 1770-KF2 (Pre-configured) 9F/25M pin Modem Cable 25M/25F pin Modem Cable Tutorial CD-ROM 15 DH+cable with termination Industrial Modem 1770-KF2 Installation Manual
Paging
1785-CHORAPM1 Connect to Enhanced PLC-5 Qty:1 Paging Modem Qty:1 25F/25M pin Modem Cable Qty:1 Configuration CD-ROM 1747-CHORAPM1 Connect to SLC 5/03, 5/04, 5/05 Qty:1 Paging Modem Qty:2 9F/25M pin Modem Cable Qty:1 Configuration CD-ROM 17 61-MICRORAPM1 Connect to MicroLogix 1000, 1200, 1500 Qty:1 Paging Modem Qty:1 AB DIN /25M pin Modem Cable Qty:1 Configuration CD-ROM
1747-CHORAPM Connect to SLC 5/03, 5/04, 5/05 Qty:1 Qty:1 Qty:2 Qty:1 Paging Modem Dial-up Modem 9F/25M pin Modem Cable Configuration CD-ROM
1785-CHORAD Connect to Enhanced PLC-5 Qty:1 Qty:1 Qty:1 Qty:2 9F/25M pin Modem Cable 25M/25M pin Modem Cable Tutorial CD-ROM Industrial Modem
1785-CHORAD1 Connect to Enhanced PLC-5 Qty:1 25M/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem 1747-CHORAD1 Connect to SLC 5/03, 5/04, 5/05 Qty:1 9F/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem 1747-KERAD1 Connect to DH485 Network Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 1747-KE Module (Pre-configured) 9F/25M pin Modem Cable 1747-C13 DH-485 Cable Tutorial CD-ROM Industrial Modem 1747-KE Installation Manual
17 61-MICRORAPM Connect to MicroLogix 1000, 1200, 1500 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Paging Modem Dial-up Modem 9F/25M pin Modem Cable AB DIN /25M pin Modem Cable Configuration CD-ROM
1747-CHORAD Connect to SLC 5/03, 5/04, 5/05 Qty:2 9F/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:2 Industrial Modem 1747-KERAD Connect to DH485 Network Qty:1 Qty:2 Qty:1 Qty:1 Qty:2 Qty:1 1747-KE Module (Pre-configured) 9F/25M pin Modem Cable 1747-C13 DH-485 Cable Tutorial CD-ROM Industrial Modem 1747-KE Installation Manual
17 61-MICRORAD Connect to MicroLogix 1000, 1200, 1500 Qty:1 Qty:1 Qty:1 Qty:2 9F/25M pin Modem Cable AB DIN /25M pin Modem Cable Tutorial CD-ROM Industrial Modem
17 61 MICRORAD1 Connect to MicroLogix 1000, 1200, 1500 Qty:1 AB DIN /25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem
Software Compatibility
Rockwell Automation recognizes the diverse requirements of our customers. For this reason, we designed our Remote Access ModemKits to be compatible with a wide variety of software and hardware platforms under the Windows 95/98/NT operating systems. Some software packages and/or configurations do not support remote access or are not compatible with a particular operating system. The table to the right lists and cross-references all the configurations currently supported with the Remote Access Modem Kits.
Windows 95 /Windows 98 DH-485 RSLogix 5 RSLogix 500 AI 5 Software AI 500 Software 6200 PLC 5 Windows NT Version 4.0 DH-485 RSLogix 5 RSLogix 500 AI 5 Software AI 500 Software 6200 PLC 5 RSLinx 2.0 RSLinx 2.0 DH+ RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 SLC channel 0 PLC channel 0 RSLinx 2.0 Internal RSLinx 2.0 DH+ RSLinx 2.0 RSLinx 2.0 Internal/RSLinx Internal Internal/RSLinx Internal Internal/RSLinx RSLinx 2.0 Internal/RSLinx SLC channel 0 PLC channel 0 RSLinx 2.0
Micrologix 1000/1500 only supports RSLogix 500 (ver.3.01 or higher)and RSlinx (ver.2.0 or higher)
Remote Access Paging Modem Kits for SLC 5/03, 5/04 and 5/05 1747-CH0RAPM (dual modem kit) - Includes all necessary hardware and software for both alpha-numeric paging and dial-up online programming through SLC channel 0 (DF1 port). 1747-CH0RAPM1 (single modem kit) - Includes all necessary hardware an software for alphanumeric paging through SLC channel 0 (DF1 port).
Modem Specifications Dimensions: Height:1.5 ,Width:4.5 , Length:7.5 ,Weight:1.5Ib LED Displays for: TXD,RXD,CTS,DSR,DTR,CXR,EC,AA,SYN,SPD,F X Operating Speeds: 19.2K,16.8K,14.4K,12.0K,9600,7200, 4800,1200, and 300 BPS
Programming PC
Temperature: Operating:32 to 122 F (0 to +50 C) ambient; Humidity 5 -95%NC Compliance: FCC Part 68,Part 15-Class b, UL/CSA/DOC Certified,REN 0.8B,CTR 21 Remote Configuration: Local control of remote modem s configuration (requires remote access modems at receiving and sending end) Mounting: 35 mm-din rail or tabletop
Remote Access Paging Modem Kits for MicroLogix 1000, 1200 and 1500 1761-MICRORAPM (dual modem kit) - Includes all necessary hardware and software for both alphanumeric paging and dial-up online programming through MicroLogix DF1 port. 1761-MICRORAPM1 (single modem kit) - Includes all necessary hardware and software for alpha-numeric paging through MicroLogix DF1 port.
Programming PC
MicroLogix Channel 0
Switches: 10 DIP switch (disabled),Power on/off, speaker,volume, and front panel dialing Flow Control: Uni/8Bi-directional Xon/Xoff and RTS/CTS
Remote Access Paging Modem Kits for Enhanced PLC-5 processors 1785-CH0RAPM (dual modem kit) - Includes all necessary hardware and software for both alpha-numeric paging and dial-up online programming through PLC5 channel 0 (DF1 port). 1785-CH0RAPM1 (single modem kit) - Includes all necessary hardware and software for alpha-numeric paging through PLC5 channel 0 (DF1 port).
Programming PC
PLC-5 Channel 0
Modem Configuration
To help eliminate connection problems, every Remote Access Modem Kit comes with a pre-configured modem. Each modem is set to a default connection rate of 9600 baud. Although this rate has proven to be the most reliable, modems can support line speeds up to 19200K baud. Additional modem features include: Call-back feature with password protection prohibits unauthorized access Front panel dialing allows connectivity through automated call-routing systems. Remote Configuration Feature All remote modem settings can be changed through the dial-up connection when using a pair of Remote Access modems. This powerful feature enables the remote modem settings to be changed to match altered processor port settings.
Ordering Information
To order Remote Access Dial-in Kits,contact your local Rockwell Automation distributor.For more information,visit our web site at
www.ab.com/networks/remote_access
Copyright 2000 Rockwell International Corporation.DH-485,SLC, PLC 5,Data Highway Plus,and DH+are trademarks of Rockwell Automation.RSLogix,Al 5,WinLogix,RSLinx,and RSLinx Lite are trademarks of Rockwell Software.Windows 95,Windows 98,and Windows NT are trademarks of Microsoft Corporation.
Copyright 2000 Rockwell International Corporation. All trademarks and registered trademarks are property of their respective companies.