Sunteți pe pagina 1din 6

Remote Access Modem Kits

The Complete Solution for Remote Connection to Programmable Controllers and Control Networks Dialup Programming Alphanumeric Paging AutoDialer Supervisory Control and Data Acquisition

Remote Access Dial-in Modem Kits Remote Access Dial-in Modem Kits are designed for easy installation and configuration of dialup communications. Each kit comes complete with everything you need to establish a dial-up connection to your Allen-Bradley control system. Remote Access Dial-in modems are ideal for remotely supporting your control system. You can minimize support costs by remotely dialing in for: Online Programming Uploading/Downloading Processor and MMI Programs Updating Processor and MMI Firmware Monitoring Data Table Values Real-time Collecting Data Checking System Status

Remote Access Paging Modem Kits Remote Access Paging Modem Kits offer all of the features of our dial-in kits plus the added capability of alphanumeric paging. Remote Access Paging Modems allow even the simplest control system to forward alarm conditions and system status messages to most alphanumeric pagers. Additional features include: 250 Alarm Triggers from Binary or Integer Files 250 User-defined Text Messages Multi-pager Support (up to 16 users) Text Messages up to 100 Characters Integer File Variables Embedded into Alarm Text Internet-based Text Pager Services* Such as Text (processor alarm) Forwarding to E-mail, Fax, Voice Synthesis and Operator Dispatch. System Diagnostic Pages
* Check with your alphanumeric pager provider for available services

www.ab.com/networks/remote_access

Product Profile

Remote Access Dial-in Modem Kits


Rockwell Automations Remote Access Dial-in Kits provide a complete solution for remote dial-in connections to your programmable controller and/or control network.Kits are ready to use right from the box and allow you to conveniently monitor processes,collect data or make program changes from an off-site location. All Remote Access kits come complete with pre-configured industrial modems, interconnecting cables, selected communication network interfaces, din-rail mounting brackets and a detailed, CD-ROM based Installation Guide. Kits also include: Factory-tested and documented configurations Pre-configured communication module (network kits only) Comprehensive installation and configuration instructions for Windows 95/98/NT4 One year of award-winning Rockwell Automation technical support Installation Guide Our comprehensive installation guide leads you through an intuitive,userfriendly configuration process.This interactive CD-based resource uses a variety of screen shots and application examples to make remote connection fast and easy.Whether you begin with the step-by-step tutorial,or use the index and search tools to target specific reference material, the Remote Access installation guide will help ensure you get connected the first time and every time. Supported Configurations The following configurations are supported with the rermote access dial-in kit.
DH-485 Connection: throught the 1747-KE module residing in an SLC chassis. Enables you to go on-line with a processor over the DH-485 network
Supported Software: RSLogix 500, Al 500 Order Kit #: 1747-KERAD

Direct Connect to Enhanced PLC-5: Connection through the Channel 0 DF1 Comm Port of the PLC-5 enhanced processor. Enhanced processors include all PLC-5 processors.
Supported Software: RSLogix 500, Al 5, 6200 PLC-5 Order Kit #: 1747-CHORAD

Programming PC

PLC-5 Channel 0

Data Highway Plus Connection: through the 1770-KF2 module. Enables user to go on-line with a PLC-5 or SLC 5/04 controller over the Data Highway Plus network.

Supported Software: RSLogix 500, RSLogix 5, Al 500, Al 5, 6200 PLC-5 Order Kit #: 1770-KF2RAD 1700-KF2 Programming PC

Direct Connect to SLC 5/03, SLC 5/04, SLC 5/05: Enables user to go on-line with an SLC processor through DF1 Channel 0. As shown, the SLC 5/04 can be configured to enable pass thru over to the DH+ Network.
SupportedSoftware: RSLogix 500, Al 500 Order Kit #: 1747-CHORAD

Programming PC

SLC Channel 0 Connection

Direct Connect to MicroLogic 100/1200/1500: Enables user to go on-line with MicroLogix processor through DF1 Channel 0.
Supported Software: RSLogix 500 Order Kit #: 1761-MICRORAD (For 1769-LRP, use 1747-CHORAD)

Programming PC

1747-KE Connection

Programming PC

MicroLogix Channel 0

Remote Access Paging Modem Kits

Programming Computer

PLC-5

Paging Modem

Pager Paging Company

Remote Access Paging Modem Kits provide the ability to monitor alarm conditions in an A-B control process and have alarm information sent to an alphanumeric pager. Remote Access Paging Modems support: Enhanced PLC -5, SLC 5/03, 5/04, 5/05, MicroLogix 1000, 1200 or 1500 processors. Each kit contains Microsoft Windows based Remote Access Paging Modem configuration software. This software configures the Remote Access Paging Modem communications between your Allen-Bradley Controller and your Alphanumeric Pager Service Provider. The Remote Access Paging Modem Configuration software allows you to custom configure address books of people to receive pages, up to 250 alarm triggers (Binary or Integer), and up to 100 characters of alphanumeric message text per alarm with your choice of Integer File variables embedded in the text messages. For example, a critical alarm temperature condition is present in a control process. An alarm condition generated by a Remote Access Paging Modem can be displayed on a alphanumeric pager as:Tank # 7 is over temperature Current temp is 100 degrees Celsius. In the alphanumeric page, the alarm text is Tank # {N7:10} is over temperature Current temp is {N10:5} degrees Celsius. The variables 7 {N7:10} and 100 {N10:5} where embedded into the alarm text. These variables ( 7 and 100) are integer file values. Remote Access Paging Modem Kits also provide the ability to quickly and easily remotely program Allen-Bradley controllers.

Modem Kit Components


Each kit includes all the components necessary to establish a remote connection. For additional connections, single modem kits are also available. Single modem kits include one modem and cable for receiving end of a dial-in conneciton. Note: to take advantage of the advanced remote configuration feature, a Remote Access modem must also be used for transmitting. For this reason, it is recommended that a dual modem kit be purchased first. Dual Modem Kits Dial-in
1770-KF2RAD Connect to DH+Network Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:2 Qty:1 1770-KF2 (Pre-configured) 9F/25M pin Modem Cable 25M/25F pin Modem Cable Tutorial CD-ROM 15 DH+cable with termination Industrial Modem 1770-KF2 Installation Manual

Single Modem Kits Paging


1785-CHORAPM Connect to Enhanced PLC-5 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Paging Modem Dial-up Modem 9F/25M pin Modem Cable 25F/25M pin Modem Cable Configuration CD-ROM

Dial-in
1770-KF2RAD1 Connect to DH+Network Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 1770-KF2 (Pre-configured) 9F/25M pin Modem Cable 25M/25F pin Modem Cable Tutorial CD-ROM 15 DH+cable with termination Industrial Modem 1770-KF2 Installation Manual

Paging
1785-CHORAPM1 Connect to Enhanced PLC-5 Qty:1 Paging Modem Qty:1 25F/25M pin Modem Cable Qty:1 Configuration CD-ROM 1747-CHORAPM1 Connect to SLC 5/03, 5/04, 5/05 Qty:1 Paging Modem Qty:2 9F/25M pin Modem Cable Qty:1 Configuration CD-ROM 17 61-MICRORAPM1 Connect to MicroLogix 1000, 1200, 1500 Qty:1 Paging Modem Qty:1 AB DIN /25M pin Modem Cable Qty:1 Configuration CD-ROM

1747-CHORAPM Connect to SLC 5/03, 5/04, 5/05 Qty:1 Qty:1 Qty:2 Qty:1 Paging Modem Dial-up Modem 9F/25M pin Modem Cable Configuration CD-ROM

1785-CHORAD Connect to Enhanced PLC-5 Qty:1 Qty:1 Qty:1 Qty:2 9F/25M pin Modem Cable 25M/25M pin Modem Cable Tutorial CD-ROM Industrial Modem

1785-CHORAD1 Connect to Enhanced PLC-5 Qty:1 25M/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem 1747-CHORAD1 Connect to SLC 5/03, 5/04, 5/05 Qty:1 9F/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem 1747-KERAD1 Connect to DH485 Network Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 1747-KE Module (Pre-configured) 9F/25M pin Modem Cable 1747-C13 DH-485 Cable Tutorial CD-ROM Industrial Modem 1747-KE Installation Manual

17 61-MICRORAPM Connect to MicroLogix 1000, 1200, 1500 Qty:1 Qty:1 Qty:1 Qty:1 Qty:1 Paging Modem Dial-up Modem 9F/25M pin Modem Cable AB DIN /25M pin Modem Cable Configuration CD-ROM

1747-CHORAD Connect to SLC 5/03, 5/04, 5/05 Qty:2 9F/25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:2 Industrial Modem 1747-KERAD Connect to DH485 Network Qty:1 Qty:2 Qty:1 Qty:1 Qty:2 Qty:1 1747-KE Module (Pre-configured) 9F/25M pin Modem Cable 1747-C13 DH-485 Cable Tutorial CD-ROM Industrial Modem 1747-KE Installation Manual

17 61-MICRORAD Connect to MicroLogix 1000, 1200, 1500 Qty:1 Qty:1 Qty:1 Qty:2 9F/25M pin Modem Cable AB DIN /25M pin Modem Cable Tutorial CD-ROM Industrial Modem

17 61 MICRORAD1 Connect to MicroLogix 1000, 1200, 1500 Qty:1 AB DIN /25M pin Modem Cable Qty:1 Tutorial CD-ROM Qty:1 Industrial Modem

Software Compatibility
Rockwell Automation recognizes the diverse requirements of our customers. For this reason, we designed our Remote Access ModemKits to be compatible with a wide variety of software and hardware platforms under the Windows 95/98/NT operating systems. Some software packages and/or configurations do not support remote access or are not compatible with a particular operating system. The table to the right lists and cross-references all the configurations currently supported with the Remote Access Modem Kits.

Windows 95 /Windows 98 DH-485 RSLogix 5 RSLogix 500 AI 5 Software AI 500 Software 6200 PLC 5 Windows NT Version 4.0 DH-485 RSLogix 5 RSLogix 500 AI 5 Software AI 500 Software 6200 PLC 5 RSLinx 2.0 RSLinx 2.0 DH+ RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 RSLinx 2.0 SLC channel 0 PLC channel 0 RSLinx 2.0 Internal RSLinx 2.0 DH+ RSLinx 2.0 RSLinx 2.0 Internal/RSLinx Internal Internal/RSLinx Internal Internal/RSLinx RSLinx 2.0 Internal/RSLinx SLC channel 0 PLC channel 0 RSLinx 2.0

Micrologix 1000/1500 only supports RSLogix 500 (ver.3.01 or higher)and RSlinx (ver.2.0 or higher)

Remote Access Paging Modem Kits for SLC 5/03, 5/04 and 5/05 1747-CH0RAPM (dual modem kit) - Includes all necessary hardware and software for both alpha-numeric paging and dial-up online programming through SLC channel 0 (DF1 port). 1747-CH0RAPM1 (single modem kit) - Includes all necessary hardware an software for alphanumeric paging through SLC channel 0 (DF1 port).

Modem Specifications Dimensions: Height:1.5 ,Width:4.5 , Length:7.5 ,Weight:1.5Ib LED Displays for: TXD,RXD,CTS,DSR,DTR,CXR,EC,AA,SYN,SPD,F X Operating Speeds: 19.2K,16.8K,14.4K,12.0K,9600,7200, 4800,1200, and 300 BPS

Programming PC

SLC Channel 0 Connection

Temperature: Operating:32 to 122 F (0 to +50 C) ambient; Humidity 5 -95%NC Compliance: FCC Part 68,Part 15-Class b, UL/CSA/DOC Certified,REN 0.8B,CTR 21 Remote Configuration: Local control of remote modem s configuration (requires remote access modems at receiving and sending end) Mounting: 35 mm-din rail or tabletop

Remote Access Paging Modem Kits for MicroLogix 1000, 1200 and 1500 1761-MICRORAPM (dual modem kit) - Includes all necessary hardware and software for both alphanumeric paging and dial-up online programming through MicroLogix DF1 port. 1761-MICRORAPM1 (single modem kit) - Includes all necessary hardware and software for alpha-numeric paging through MicroLogix DF1 port.

Programming PC

MicroLogix Channel 0

Switches: 10 DIP switch (disabled),Power on/off, speaker,volume, and front panel dialing Flow Control: Uni/8Bi-directional Xon/Xoff and RTS/CTS

Remote Access Paging Modem Kits for Enhanced PLC-5 processors 1785-CH0RAPM (dual modem kit) - Includes all necessary hardware and software for both alpha-numeric paging and dial-up online programming through PLC5 channel 0 (DF1 port). 1785-CH0RAPM1 (single modem kit) - Includes all necessary hardware and software for alpha-numeric paging through PLC5 channel 0 (DF1 port).

Diagnostics: Self-Test (ST),ALB,LB-ST,DLB,RDLB,RDLB-ST,V.54 Operation: Full Duplex over 2-wire dial-up

Programming PC

PLC-5 Channel 0

Modem Configuration
To help eliminate connection problems, every Remote Access Modem Kit comes with a pre-configured modem. Each modem is set to a default connection rate of 9600 baud. Although this rate has proven to be the most reliable, modems can support line speeds up to 19200K baud. Additional modem features include: Call-back feature with password protection prohibits unauthorized access Front panel dialing allows connectivity through automated call-routing systems. Remote Configuration Feature All remote modem settings can be changed through the dial-up connection when using a pair of Remote Access modems. This powerful feature enables the remote modem settings to be changed to match altered processor port settings.

Ordering Information
To order Remote Access Dial-in Kits,contact your local Rockwell Automation distributor.For more information,visit our web site at

www.ab.com/networks/remote_access
Copyright 2000 Rockwell International Corporation.DH-485,SLC, PLC 5,Data Highway Plus,and DH+are trademarks of Rockwell Automation.RSLogix,Al 5,WinLogix,RSLinx,and RSLinx Lite are trademarks of Rockwell Software.Windows 95,Windows 98,and Windows NT are trademarks of Microsoft Corporation.

Copyright 2000 Rockwell International Corporation. All trademarks and registered trademarks are property of their respective companies.

Doc ID: RADKIT-PP001C-EN-P - February 2001

S-ar putea să vă placă și