MGE UPS SYSTEMS

Galaxy 3000
10/15/20/30 kV A

Data Center Grade Power Protection for Critical Environments

Advanced Features
Parallel ready Scalable power levels Field upgradeable single to parallel module Distortion free input Network based power management Fault tolerant architecture All-in-one complete solution Compact footprint Full front access Ultra high availability topology (UHAT) Input Power Factor Correction (PFC) User friendly graphical interface Digital Power Quality Management Power surge stabilization for IT equipment startup Generator friendly technology Galaxy 3000 is available as a UL 924 system for Emergency Lighting Applications

T H E

U N I N T E R R U P T I B L E

P O W E R

P R O V I D E R

MGE A World Leader in Power Protection Solutions


MGE UPS SYSTEMS is a world leader in providing superior power protection for sensitive electronic and electrical equipment. Providing high quality solutions to ensure continuous power availability to critical data and processes for over 40 years, our expertise in data centers is second to none in the industry with the unique ability to provide you with a total solution that meets your critical needs. MGEs family of Uninterruptible Power Supplies (UPS), Power Distribution Units (PMM/RPMM) and complementary communications software and connectivity device, provide power protection and management for mission-critical requirements for data centers and other critical needs. Selected by 95% of the Fortune 100 companies to protect their vital information systems, MGE is ready to meet your needs. MGE A Global Leader MGE is a global company that can provide customers with global solutions implemented at a local level. With over 170 sales and service centers in over 100 countries, MGE has the ability to meet your needs anywhere in the world. MGE Solutions Include: Uninterruptible Power Supplies Power Distribution Units and Static Transfer Switches Remote Power Management Battery Maintenance and Monitoring MGE PowerServicesTM Maintenance Contracts

Critical Power Protection


Double Conversion On-line Topology: The Galaxy 3000s double conversion topology uses the rectifier and inverter to isolate devices on the UPS output from the dangers of raw utility power - never exposing the critical load. Double conversion topology also allows the UPS to regulate the output frequency without switching to battery power, a necessity for continued reliable operation with a generator.

User friendly operation: With 30 years experience in the manufacture of UPS systems, MGE realizes user error accounts for a majority of UPS load drops. The Galaxy 3000s graphical user interface presents information, like operator instructions, in a clear and safe manner preventing unnecessary operator errors. Also depicted are alarm/event logs, mimic diagrams, and detailed system status information.

Power Factor Correction


While most UPS provide clean power on the output, the rectifier can reflect distortion back onto the utility power, disturbing other equipment sharing the utility power in the rest of the facility. The Galaxy 3000 is equipped with Input Power Factor Correction (PFC) for practically distortion free (<3% THD) input. Since the Galaxy 3000 uses a unique IGBT (Insulated Gate Bipolar Transistor) rectifier, input harmonics are eliminated without an input filter (required on other UPS). Unique Advantages of Galaxy 3000 Input Power Factor Correction Eliminates reflected harmonics on the input keeping utility power clean for the rest of the facility Contributes to unsurpassed generator compatibility Eliminates costly and bulky input filters reducing UPS power consumption by 20% Increased reliability with fewer components Traditional UPS with Filter

Clean Power on the Input and the Output


Reflected Distortion

UPS w/ 12 pulse rectifier

Galaxy 3000

Galaxy 3000 with IGBT Rectifier Traditional UPS with Input Filter UPS without Input Filter

Current Distortion <3% <10% >25%

Power Factor >0.99 0.95 0.85

While a UPS provides clean power on the output, the rectifier used on their input reflects disturbances back on to the utility disturbing nearby devices that share the power. Even a UPS equipped with input filters dont ensure that some distortion wont be reflected onto the utility. The above chart shows that the Galaxy 3000s IGBT rectifier is the most effective technology for reducing reflected distortion, and does not require the hidden cost and energy consumption associated with an input filter.

Output

ScalableReady to grow with your Business demands


Galaxy 3000 Parallel Ready Pay as you grow Fit the budget you have today Meet the future needs of your organization Simply add a new module when you need more power Up to three times the initial capacity (up to 90kVA) Fourth module for N+I redundancy Easy integration with networking and monitoring systems

Simple and Secure Paralleling Technology


Source 2 (Bypass) Source 1 (Main)
UPS 2

Choice A: Galaxy 3000 Parallel module (20/30kVA) for redundancy or capacity


UPS 1

simply by bussing the output of the modules to share the load equally. If any module goes
To Critical Load
System Maintenance Bypass

offline, the critical load is supported by the remaining modules. Should the remaining modules go offline, the critical load will automatically and seamlessly transfer to the utility via an internal module static bypass switch. Parallel intelligence resides in each module for true redundancy. MGE offers several versions of the system wrap-around bypass (SBC),

Source 1 (Main)
UPS 3

Source 1 (Main)

Integrated Parallel

including distribution and secondary UPS isolation breakers, to allow safe and hassle free operation.

Source 2 (Bypass)

UPS 1

Choice B: Galaxy 3000 Single Module in an Isolated Redundant UPS system design

Isolated Redundant
Source 1 (Main)

offers unmatched flexibility. The basic concept of this design is to always provide clean, conditioned power to the critical load, never raw utility power, regardless of UPS shutdown

UPS 2
To Critical Load

or maintenance operation. Redundancy is accomplished by installing an equally sized Single UPS modules that supplies

Source 1 (Main)

the bypass static switch and maintenance bypass of the primary module supplying the load. The illustration depicts a two module (1+1) isolated redundant system.

Communication
MGE Network Power Management Advantages Automatic shutdown/restart of an unlimited number of servers View power system status from any point on the WAN Integration with Enterprise-wide management systems Pager or E-mail notification of power events Load shedding for optimized use of backup power Environmental monitoring and management Communications cards for every application including: XML/Web, SNMP/Web, U-Talk (RS232-ASCII), RS232/RS485 (Modbus / JBUS), USB and a standard programmable dry contact card (2 input / 6 output)

Internet Ready Monitoring Module

Galaxy 3000 Technical Specifications


UPS Rating kVA/KW Input Voltage Frequency Power Factor Current Distortion (THDI) Input Current (A @ 208V) Output Voltage Frequency Voltage Regulation Voltage Transient Response Voltage Recovery Time Voltage Distortion THD Inverter Overload Bypass Overload Output Current (A @ 208V) Heat Rejection (BTUs) (@ 208V) Environmental Operating Temperature Non-Operating Temperature Relative Humidity Dimensions and Weights Single Module UPS Micro Cabinet Standard Cabinet Auxiliary Cabinet (matching Maintenance Bypass, Output Transformer, Distribution) Auxiliary Cabinet (42 Pole Distribution) Battery Cabinet Parallel Module UPS (20/30kVA) System Bypass Cabinet Distribution Cabinet Standards 10/8 15/12 20/16 30/24 208V, 220V, 480V, 600V, 3 Phase, 4 Wire + G (+15%) (Parallel Module 208V only) 60 Hz (+8/-25%) <0.99 <3 % 42 56

Standard Features
Double Conversion On-line topology Input Power Factor Correction (IGBT rectifier) Input Distortion Management
83

28

Step Load Voltage Stabilization Intelligent Battery Management System Fault Tolerant Architecture Scalable Architecture (10 & 20 kVA models) Integrated maintenance bypass (Single Module only) Dry contact I/O card Casters with stabilizing feet Color graphic display with multilingual user interface Bottom or top entry Three communications slots

208V (220V, 480V, 600V w/aux cabinet), 3 Phase, 4 Wire + G (Parallel Module 208V only) 60 Hz, 1% (selectable to 4%), 0.1% free running 1.0% for balanced load 2.5% for 100% unbalanced load 5% for 100% step load 1% for loss or return of AC input Within 1% of nominal within 1 cycle <3% L-L and L-N for non-linear loads 120% for 1 min, 145% for 30 sec 10 x nominal current for 1 cycle 28 42 56 83 4821 7232 8895 13342 UPS: 0 to 40C (32F to 104F) Battery: 25C (77F) 20C to +45C (4F to113F) 0-95% non-condensing
W x D X H in inches ( l b s . )

23.0W X 35.5D X 48.5H (830 lbs max) 32.8W X 40.1D X 62.4H (2,565 lbs max) 18.8W X 40.1D X 62.4H (450 lbs max) 18.8W X 40.1D X 62.4H (180 lbs max) 33.0W X 35.6D X 62.4H (2,723 lbs max) 32.8W X 40.1D X 62.4H (7565 lbs max) 28.8W X 35.64D X 62.33H (300 lbs max) 18.8W X 35.64D X 62.33H (180 lbs max) ISO 9001, UL 1778, cUL, UL924, FCC Part 15, Subpart J, Class A, NEMA PE 1, NEMA 250, NFPA 70, IEC 1000 (801) level 4, OSHA

Common Options (Single or Parallel)


Integrated Battery Bank Dual Input Remote Alarm Status Panel (RASP) Remote Summary Alarm Panel (RSAP) Advanced power management software Network Management Card/Web SNMP RS232, RS485 and dry contacts IBM AS400 Interface RemotePowerMonitoring

Maintenance Bypass Input


(Optional)

CB1 CB3 (Optional) Bypass Static Switch Q3BP 24 or 42 poles

Galaxy 3000 Single Module Single Line

Bypass Input
(Optional)

KA2

(Isolation Transformer Optional)

Input Fuses

QF1

Battery System
(External Cabinet Optional)
UPS Cabinet

The Critical Power and Cooling Services Business Unit of Schneider Electric
MGE UPS SYSTEMS 1660 Scenic Avenue Costa Mesa, CA 92626 tel (800) 523-0142 (714) 557-1636 fax (714) 557-9788 American Power Conversion 132 Fairgrounds Rd. West Kingston, RI 02892 tel (401) 789-5735 ext 2128 fax (401) 788-2782
www.mgeups.com info@mgeups.com GX 3000 Revision 301 Effective: November 2007

MGE UPS SYSTEMS, Inc. All specifications subject to change without notice. The MGE UPS SYSTEMS logo is a trademark of MGE UPS SYSTEMS.

Main Input

KA1

PFC Rectifier

Inverter Output Fuses

Output Static Switch Q5M Internal Maintenance Bypass


Wraparound Output Maintenance Transformer Bypass
(Optional) (Optional)

Single Module Options


CB2 To Load

Matching power distribution unit (24 or 42 pole) External maintenance bypass

Output Distribution Cabinet


(Optional)

Input isolation transformer

Parallel Module Options Galaxy 3000 Parallel Module Single Line


2CB or 3CB System Bypass Cabinet 2 to 4CB secondary UPS Isolation Circuit Breaker System Bypass Distribution up to 84 pole Remote Alarm Status Panel (RASP) 2/3/4 Module