Documente Academic
Documente Profesional
Documente Cultură
RMC SOLUTIONS
ACE3600 MOSCAD-M
IP-GW M-OPC
Water Electricity
Early Warning
SCADA/HMI Station
Programming Tool
ALLEN BRADLEY DF1 MASTER ON RS232 IEC 60870-5-101 SLAVE ON RS232 IEC 60870-5-104 SLAVE ON ETH
RTUs
ACE3600
MOSCAD-M
Accessories
ACT (Alarm control Tone)
Power Supply
CPU
Frames
I/O Modules
Radios
Software
Frame
On Metal Chassis
In Housing
FRAMES
The ACE3600 frames have the following tasks:
To hold the Power-Supply, CPU and I/O modules To connect the modules with operating voltages To connect the modules to the CPU
All frames can be installed on a wall The 8 I/O Frame can also be installed on a 19 rack The following frames are available:
No I/O frame Power Supply and CPU only 2 I/O slot frame - Power Supply, CPU and 2 I/O slots 3 I/O slot frame - Power Supply, CPU and 3 I/O slots 5 I/O slot frame - Power Supply, CPU and 5 I/O slots 7 I/O slot frame - Power Supply, CPU and 7 I/O slots 8 I/O slot frame - Power Supply, CPU and 8 I/O slots
PS & CPU Slots I/O Slots
No I/O
2 I/O
3 I/O
5 I/O
7 I/O
METAL CHASSIS
ACE3600 frames can be ordered with small or large Metal Chassis as an option. For 19 rack installation a 19 Metal Chassis is available. The Metal Chassis enables installation of radio(s), backup battery and other accessories. It can be installed on a wall or in a cabinet.
19 Chassis
HOUSING
ACE3600 can be ordered with small or large NEMA 4 (IP66) metal housing for outdoor installation. The housing includes a metal chassis that enables installation of radio, backup battery and other accessories. The housing can be installed on a wall.
Power Supply
CPU
Inputs
Outputs
Mixed I/O
PS2
CPU1
4 I/O cards
CPU2
CPU3680 CPU4600
Metering concentrator
Conventional Radio
ACE3600
Metering concentrator
Metering concentrator
ACE3600 Microwave
Metering concentrator
ACE3600
ACE3600
Communication Node
Conventional Radio
Electric Meters
ACE3600
Metering concentrator
...
19
MOSCAD-M STRUCTURE
Basic I/Os - 12DI, 4 Relay DO, 4 FET DO Expanded I/O board - Additional 3DI, 4AI, 1AO Power Management for low consumption One RS485/RS232 Port (Dialup/User/MDLC) One RS-232 Ports (MDLC/Dialup/User) One RS-232 or Radio (PPP/MDLC/Configuration) LED display - functional/diagnostic Indoor Housing (Wall/DIN rail mounting) Programmable by C Toolkit for custom application programming
RS-232/RS-485 (MDLC) OR External Radio
DI, AI DO, AO
SUPERVISED DEVICES
CONTROLLED DEVICES
Configuration Tool
S&F Repeater
RTU RTU
FIU
SCADA HMI
I/O Control
STS ToolBox
Wireless Network
RTU
Front End
RTU
Radio
Master Control Centre
RTU
(-)
CP Injection
ACE3600 RTU
CP Monitoring
Oil and Gas
IP Gateway
Communications
DNP 3.0, IEC 61850, IEC 60870-5-10x
ltiiOTOROLA SOLUTIONS