Documente Academic
Documente Profesional
Documente Cultură
Low voltage General performance IE2 high efficiency motors according to EU MEPS
We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers processes over the total life cycle of our products, and beyond.
2 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
General performance IE2 high efficiency motors according to EU MEPS Sizes 56 to 355, from 0.06 to 355 kW
ABBs General performance IE2 high efficiency motors are best suited for applications where simplicity and offthe-shelf availability are paramount. With ABB quality and support these motors have the features appreciated by volume customers and serial OEMs. Motors have IE2 efficiency. Motor range for cast iron motors 71 to 355, 0.25 to 250 kW and aluminum motors is 56 to 250, 0.06 to 55 kW.
Ordering information 04 Technical data Cast iron 05 Aluminum 08 Variant codes Cast iron 11 Aluminum 13 Dimension drawings Cast iron 15 Aluminum 15 General performance motors in brief Cast iron 16 Aluminum 19
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 3
Ordering information
When placing an order, please state the following minimum data in the order, as in the example. The product code of the motor is composed in accordance with the following example.
Motor type Pole number Mounting arrangement (IM-code) Rated output Product code Variant codes if needed
Motor size
A B C D, E, F
4 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
General performance cast iron motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 3000 r/min = 2 poles 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 110 M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA M2BA 71 MA 71 MB 80 MB 80 MC 90 SLB 90 SLC 100 LB 112 MB Speed r/min 2660 2680 2895 2870 2900 2885 2925 2895 2865 2890 2920 2934 2934 2933 2950 2947 2956 2960 2977 2976 2982 2982 2981 2980 2983 2980 2983 2978 Full 3/4 load load 100% 75% 69.2 73.2 80.6 81.8 82.2 84.7 85.2 86.1 88.0 88.6 89.8 91.1 91.0 91.5 92.2 92.5 93.0 93.9 94.0 94.3 94.6 94.9 95.2 95.3 95.4 95.4 95.5 94.7 73.5 77.3 79.9 82.4 84.1 86.7 84.9 87.0 88.6 88.8 91.0 92.2 91.8 92.8 92.9 93.0 93.5 94.3 93.7 94.2 94.1 94.6 95.0 95.2 95.2 95.4 95.5 94.6 1/2 load 50% 73.7 79.3 76.2 80.2 82.7 85.7 82.8 86.6 88.0 87.5 90.7 92.0 91.2 92.8 92.3 92.5 92.9 93.6 92.3 93.1 92.7 93.4 94.1 94.4 94.3 94.7 94.9 93.8 Current Power factor I N cos j A 0.80 0.85 0.74 0.80 0.86 0.87 0.86 0.86 0.86 0.84 0.89 0.90 0.89 0.91 0.89 0.91 0.90 0.90 0.88 0.90 0.86 0.88 0.89 0.90 0.89 0.89 0.88 0.90 0.96 1.27 1.81 2.4 3 4.3 5.9 7.7 10.4 14.5 19.8 26.4 32.9 38.1 52.7 63.4 77.6 93.9 130 153 195 228 272 336 424 535 609 186 Is IN 3.9 4.3 7.7 7.5 7.5 6.8 9.1 8.1 7.0 7.3 5.9 7.0 7.3 7.8 7.8 7.7 8.1 6.8 7.6 7.4 7.6 7.4 7.5 7.7 6.8 7.2 7.4 7.9 Torque TN Nm 1.32 1.95 2.4 3.6 4.9 7.2 9.7 13.1 18.3 24.7 35.9 48.8 60.2 71.6 97.1 119 145 177 240 288 352 422 512 640 800 Tl TN 2.2 2.4 4.2 2.7 2.5 1.9 3.1 2.9 2.0 2.0 1.6 2.5 2.6 3.0 2.7 2.8 3.1 2.6 2.1 2.1 2.0 2.3 2.6 1.5
IE2
Product code 400 V 50 Hz 3GBA 071 211-B 3GBA 071 212-B 3GBA 081 212-B 3GBA 081 213-B 3GBA 091 212-B 3GBA 091 213-B 3GBA 101 212-B 3GBA 111 212-B
Tb TN 2.3 2.5 4.2 3.5 2.6 2.5 3.5 3.2 2.7 3.6 2.7 3.1 3.2 3.5 3.3 3.6 3.4 2.5 3.0 2.9 3.0 3.0 3.0 2.8 2.8 2.7 3.0
Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA 2 kgm kg dB 0.00039 0.00051 0.001 0.0012 0.00254 0.0028 0.00528 0.00575 0.01275 0.01359 0.038 0.048 0.052 0.062 0.092 0.116 0.197 0.275 0.8 0.9 1.2 1.4 1.7 2.1 2.7 3.4 3.6 1.15 11 11 16 18 24 25 36 37 68 70 119 133 141 173 214 240 297 339 530 570 750 810 900 1020 1310 1450 1520 640 58 56 57 60 69 64 68 70 70 70 69 69 73 73 75 75 75 75 78 78 78 78 78 83 83 83 83 78
CENELEC-design
132 SMB 3GBA 131 212-B 132 SMC 3GBA 131 214-B 160 MLA 3GBA 161 044-G 160 MLB 3GBA 161 045-G 160 MLC 3GBA 161 046-G 180 MLA 3GBA 181 042-G 200 MLA 3GBA 201 043-G 200 MLB 3GBA 201 044-G 225 SMA 3GBA 221 042-G 250 SMA 3GBA 251 042-G 280 SA 3GBA 281 110-L 280 SMB 3GBA 281 220-L 315 SMA 3GBA 311 210-L 315 SMB 3GBA 311 220-L 315 SMC 3GBA 311 230-L 315 MLA 3GBA 311 410-L 355 SMA 3GBA 351 210-L 355 SMB 3GBA 351 220-L 355 SMC 3GBA 351 230-L 400 V 50 Hz 280 SMC 3GBA 281 230-L
2.2 3.0
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 5
General performance cast iron motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 1500 r/min = 4 poles 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 110
1)
IE2
Current Power factor I N cos j A 0.81 0.83 0.73 0.73 0.80 0.83 0.78 0.79 0.81 0.80 0.81 0.85 0.84 0.84 0.83 0.83 0.84 0.83 0.85 0.85 0.86 0.86 0.86 0.85 0.86 0.85 0.85 0.86 0.86 0.65 0.88 1.45 1.83 2.3 3 4.7 6.3 8.2 11.1 14.9 20.7 28.4 34.8 41.7 56.5 68.3 83.9 99.8 135 160 194 233 285 352 445 560 623 194 Is IN 3.5 4.0 5.0 5.3 6.1 6.3 6.4 7.7 7.0 5.9 5.6 7.1 7.2 7.9 8.0 7.3 7.2 7.4 7.3 6.9 7.2 7.2 7.1 7.2 7.0 6.7 7.3 6.8 7.6
Torque TN Nm 1.74 2.5 3.7 5 7.3 10 14.4 19.7 26.5 35.9 49.3 71.7 97.9 120 143 194 238 290 355 482 579 706 847 Tl TN 1.9 1.6 2.0 2.7 2.7 2.7 2.9 2.9 2.5 1.7 1.6 2.6 2.7 3.1 3.0 2.7 2.6 2.4 2.8 2.5 2.5 2.0 2.3 Tb TN 2.0 2.1 2.8 3.2 3.4 3.4 3.6 3.4 2.9 2.4 2.4 3.0 3.6 3.6 3.8 2.9 2.9 3.1 3.0 2.8 2.7 2.5 2.7 2.9 2.8 2.6 2.7 2.7 3.0
Product code 400 V 50 Hz 3GBA 072 211-B 3GBA 072 212-B 3GBA 082 211-B 3GBA 082 214-B 3GBA 092 212-B 3GBA 092 215-B 3GBA 102 213-B 3GBA 102 214-B 3GBA 112 212-B 3GBA 132 212-B 3GBA 132 213-B 3GBA 162 043-G 3GBA 162 044-G 3GBA 182 043-G 3GBA 182 044-G 3GBA 202 042-G 3GBA 222 043-G 3GBA 222 044-G 3GBA 252 042-G 3GBA 282 110-L 3GBA 282 220-L 3GBA 312 210-L 3GBA 312 220-L 3GBA 312 230-L 3GBA 312 410-L 3GBA 352 210-L 3GBA 352 220-L 3GBA 352 230-L 400 V 50 Hz 3GBA 282 230-L
Speed r/min 1365 1380 1415 1430 1435 1430 1450 1450 1440 1460 1450 1463 1463 1464 1465 1474 1479 1479 1478 1484 1483 1487 1487 1487 1486 1488 1488 1487 1485
Full 3/4 load load 100% 75% 68.3 72.4 74.5 81.0 83.6 84.3 85.9 86.8 86.8 89.0 89.3 90.2 90.6 91.2 91.6 92.3 93.0 93.2 93.5 94.2 94.4 94.7 95.0 95.2 95.3 95.2 95.5 95.5 94.9 70.8 74.5 73.8 80.7 84.5 85.6 85.1 87.0 87.7 89.8 90.1 91.4 91.8 92.3 92.5 93.4 93.9 94.0 94.2 94.2 94.6 94.6 95.0 95.3 95.4 95.2 95.5 95.7 95.1
1/2 load 50% 69.7 74.6 70.0 77.3 83.2 84.7 83.4 85.4 87.3 88.9 90.0 91.2 91.6 92.1 92.1 93.5 93.8 93.7 93.7 93.5 94.1 93.8 94.3 94.6 94.9 94.4 94.8 95.2 94.6
Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA 2 kgm kg dB 0.00074 0.00088 0.00144 0.00205 0.0044 0.0053 0.00948 0.011 0.0125 0.03282 0.03659 0.084 0.095 0.112 0.13 0.217 0.309 0.368 0.476 1.25 1.5 2.3 2.6 2.9 3.5 5.4 6.9 7.2 1.85 10 11 15 17 25 27 36 38 44 70 73 134 141 175 187 241 293 318 342 515 575 775 830 870 995 1400 1570 1650 640 45 45 45 50 50 56 56 58 59 67 64 65 65 62 65 62 68 68 70 71 71 78 78 78 78 82 82 82 71
CENELEC-design
M2BA 71 MA M2BA 71 MB M2BA 80 MA M2BA 80 MD M2BA 90 SLB M2BA 90 SLD M2BA 100 LC M2BA 100 LD M2BA 112 MB M2BA 132 SMB M2BA 132 SMC M2BA 160 MLA M2BA 160 MLB M2BA 180 MLA M2BA 180 MLB
1)
M2BA 200 MLA M2BA 225 SMA M2BA 225 SMB M2BA 250 SMA M2BA 280 SA M2BA 280 SMB M2BA 315 SMA M2BA 315 SMB M2BA 315 SMC M2BA 315 MLA M2BA 355 SMA M2BA 355 SMB M2BA 355 SMC M2BA 280 SMC
1027 2.4 1285 2.3 1604 2.0 2021 2.2 2279 2.4 707 3.0
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
6 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
General performance cast iron motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 1000 r/min = 6 poles 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 75 M2BA 71 MA M2BA 71 MB M2BA 80 MA M2BA 80 MB M2BA 90 SLC M2BA 90 SLE M2BA 100 L M2BA 112 MB M2BA 132 SMB M2BA 132 SMB M2BA 132 SMF M2BA 160 MLA M2BA 160 MLB M2BA 180 MLA M2BA 200 MLA M2BA 200 MLB M2BA 225 SMA M2BA 250 SMA M2BA 280 SA M2BA 280 SB M2BA 315 SMA M2BA 315 SMB M2BA 315 SMC M2BA 315 MLA M2BA 355 SMA M2BA 355 SMB M2BA 355 SMC M2BA 280 SMC Speed r/min 900 895 915 920 960 930 950 950 975 960 965 971 970 971 975 974 985 985 990 990 992 992 992 992 992 992 991 990 Full 3/4 load load 100% 75% 63.7 67.2 71.0 73.9 78.7 78.2 82.2 82.5 85.3 84.9 86.1 87.6 88.7 89.7 90.7 91.0 92.2 92.4 92.8 93.3 94.0 94.3 94.7 94.9 94.9 95.2 95.3 93.8 63.8 67.2 71.1 75.0 77.3 78.6 82.9 83.8 84.5 85.3 86.6 89.1 90.1 90.8 92.0 92.4 93.1 93.2 93.0 93.5 94.0 94.4 94.8 95.0 95.0 95.4 95.5 93.9 1/2 load 50% 59.0 62.6 67.0 72.8 72.5 76.4 81.6 81.7 81.3 83.9 85.5 89.0 89.9 90.5 91.9 92.5 93.1 93.0 92.1 92.9 93.0 93.6 94.2 94.4 94.4 94.9 95.2 93.3 Current Power factor I N cos j A 0.71 0.69 0.69 0.71 0.58 0.66 0.69 0.69 0.63 0.68 0.71 0.79 0.79 0.76 0.79 0.79 0.83 0.83 0.84 0.84 0.81 0.83 0.83 0.83 0.83 0.84 0.84 0.84 0.57 0.77 1.09 1.51 2.3 3 3.8 5.5 8 10 12.9 15.6 22.6 31.7 37.2 44.1 56.5 69.6 83.3 101 142 165 201 241 293 360 450 137 Is IN 3.1 3.4 3.6 3.8 4.5 4.0 4.0 4.4 5.5 4.6 5.1 7.1 7.6 7.8 6.2 5.8 6.9 6.6 7.0 7.0 7.0 7.2 7.0 7.2 6.2 6.5 6.7 7.3 Torque TN Nm 1.9 2.6 3.8 5.7 7.4 11.2 15 22.1 29.3 39.7 54.4 73.7 108 147 181 215 290 358 434 530 721 866 Tl TN 2.0 2.2 1.8 1.8 2.3 1.9 1.5 1.7 1.8 1.5 2.0 1.9 2.1 2.5 1.7 1.8 2.4 2.4 2.5 2.7 2.1
IE2
Product code 400 V 50 Hz 3GBA 073 211-B 3GBA 073 212-B 3GBA 083 211-B 3GBA 083 212-B 3GBA 093 213-B 3GBA 093 214-B 3GBA 103 212-B 3GBA 113 212-B 3GBA 133 211-B 3GBA 133 212-B 3GBA 133 214-B 3GBA 163 043-G 3GBA 163 044-G 3GBA 183 042-G 3GBA 203 043-G 3GBA 203 044-G 3GBA 223 042-G 3GBA 253 042-G 3GBA 283 110-L 3GBA 283 120-L 3GBA 313 210-L 3GBA 313 220-L 3GBA 313 230-L 3GBA 313 410-L 3GBA 353 210-L 3GBA 353 220-L 3GBA 353 230-L 400 V 50 Hz 3GBA 283 230-L
Tb TN 2.1 2.3 2.2 2.2 3.1 2.3 1.1 2.3 2.9 2.2 2.3 3.3 3.3 4.1 3.2 3.0 2.8 2.8 2.5 2.6 2.7 2.7 2.7 2.3 2.3 2.3 2.7
Moment Sound of inertia pressure J = 1/4 GD 2 Weight level LPA kgm2 kg dB 0.00089 0.0011 0.00187 0.00239 0.00491 0.0054 0.00873 0.0125 0.03336 0.03336 0.0487 0.089 0.119 0.137 0.198 0.222 0.532 0.718 1.85 2.2 3.2 4.1 4.9 5.8 7.3 9.7 11.3 2.85 10 12 15 17 25 28 37 44 69 69 86 141 157 187 228 241 318 336 500 540 705 800 870 980 1290 1440 1590 630 42 42 47 47 44 44 49 66 57 57 57 61 61 61 65 65 65 66 71 71 75 75 75 75 77 77 77 71
CENELEC-design
2.1 2.7
1058 2.2 1270 2.4 1540 2.1 1925 2.1 2409 2.3 723 2.8
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 7
General performance aluminum motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 3000 r/min = 2-poles 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 M2AA 56 A M2AA 56 B M2AA 63 A M2AA 63 B M2AA 71 A M2AA 71 B M2AA 80 B M2AA 80 C M2AA 90 L M2AA 90 LB M2AA 100 LB M2AA 112 MB M2AA 132 SB M2AA 132 SC M2AA 160 MLA M2AA 160 MLB M2AA 160 MLC M2AA 180 MLA M2AA 200 MLA M2AA 200 MLB M2AA 225 SMA M2AA 250 SMA 3GAA 051 001-A 3GAA 051 002-A 3GAA 061 001-C 3GAA 061 002-C 3GAA 071 001-E 3GAA 071 002-E 3GAA 081 212-E 3GAA 081 213-E 3GAA 091 212-E 3GAA 091 213-E 3GAA 101 212-E 3GAA 111 212-E 3GAA 131 212-E 3GAA 131 213-E 3GAA 161 044-G 3GAA 161 045-G 3GAA 161 046-G 3GAA 181 042-G 3GAA 201 043-G 3GAA 201 044-G 3GAA 221 042-G 3GAA 251 042-G Speed r/min 2820 2840 2820 2810 2800 2790 2895 2875 2900 2875 2920 2885 2915 2915 2920 2934 2934 2933 2950 2947 2956 2960 Full 3/4 load load 100% 75% 59.8 67.2 75.0 78.6 73.8 78.4 81.4 80.6 84.1 84.6 86.4 86.1 88.0 88.5 89.8 91.1 91.0 91.5 92.2 92.5 93.0 93.9 53.3 63.8 72.0 77.0 75.8 79.8 80.8 80.5 85.0 85.7 86.0 87.0 88.5 88.7 91.0 92.2 91.8 92.8 92.9 93.0 93.5 94.3 1/2 load 50% 47.9 55.6 66.1 69.6 73.9 78.7 77.1 77.9 83.5 85.5 83.9 88.0 87.6 88.1 90.7 92.0 91.2 92.8 92.3 92.5 92.9 93.6 Current Power factor I N cos j A 0.69 0.64 0.62 0.69 0.76 0.78 0.78 0.80 0.86 0.85 0.86 0.88 0.82 0.87 0.89 0.90 0.89 0.91 0.89 0.91 0.90 0.90 0.31 0.4 0.55 0.66 0.95 1.29 1.7 2.4 2.9 4.4 5.8 7.6 11 14 19.8 26.4 32.9 38.1 52.7 63.4 77.6 93.9 Is IN 3.9 4.1 4.2 4.5 4.9 5.3 8.1 7.8 7.6 6.9 9.3 7.6 7.9 7.6 5.9 7.0 7.3 7.8 7.8 7.7 8.1 6.8 Torque TN Nm 0.3 0.4 0.6 0.84 1.26 1.88 2.4 3.6 4.9 7.3 9.8 13.2 18 24.5 35.9 48.8 60.2 71.6 97.1 119 145 177 Tl TN 2.9 3.2 3.5 3.6 2.7 2.9 3.7 3.6 2.5 2.8 3.3 2.5 2.6 2.2 1.6 2.5 2.6 3.0 2.7 2.8 3.1
IE2
Product code
Tb TN 2.7 2.8 3.1 3.3 2.7 2.8 3.9 3.5 3.3 3.2 3.9 2.8 3.6 3.2 2.7 3.1 3.2 3.5 3.3 3.6 3.4
Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA 2 kgm kg dB 0.00011 0.00012 0.00013 0.00016 0.00035 0.00045 0.0009 0.0012 0.0024 0.0027 0.005 0.0062 0.016 0.022 0.038 0.048 0.052 0.062 0.092 0.116 0.197 0.275 3.2 3.4 3.9 4.4 4.9 5.9 10.5 11 16 18 25 30 42 56 83 96 104 123 160 186 244 308 48 48 54 54 58 58 60 60 60 63 62 68 73 73 69 69 73 73 75 75 75 75
400 V 50 Hz
CENELEC-design
2.6 2.5
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
8 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
General performance aluminum motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 1500 r/min = 4 poles 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 M2AA 56 A M2AA 56 B M2AA 63 A M2AA 63 B M2AA 71 A M2AA 71 B M2AA 80 A M2AA 80 D M2AA 90 LB M2AA 90 LD M2AA 100 LC M2AA 100 LD M2AA 112 MB M2AA 132 M M2AA 132 MA M2AA 160 MLA M2AA 160 MLB M2AA 180 MLA M2AA 180 MLB M2AA 200 MLA M2AA 225 SMA M2AA 225 SMB M2AA 250 SMA 3GAA 052 001-A 3GAA 052 002-A 3GAA 062 001-C 3GAA 062 002-C 3GAA 072 001-E 3GAA 072 002-E 3GAA 082 001-E 3GAA 082 214-E 3GAA 092 214-E 3GAA 092 215-E 3GAA 102 213-E 3GAA 102 214-E 3GAA 112 212-E 3GAA 132 212-E 3GAA 132 214-E 3GAA 162 043-G 3GAA 162 044-G 3GAA 182 043-G 3GAA 182 044-G 3GAA 202 042-G 3GAA 222 043-G 3GAA 222 044-G 3GAA 252 042-G Speed r/min 1340 1370 1400 1380 1365 1375 1375 1415 1435 1435 1450 1445 1445 1465 1460 1463 1463 1464 1465 1474 1479 1479 1478 Full 3/4 load load 100% 75% 51.1 55.5 65.5 67.3 65.1 69.7 72.8 79.8 83.7 84.2 86.4 85.7 86.7 89.0 89.1 90.2 90.6 91.2 91.6 92.3 93.0 93.2 93.5 45.8 50.2 60.4 63.9 66.0 71.9 76.1 81.3 84.1 84.1 86.2 86.1 86.5 89.8 89.9 91.4 91.8 92.3 92.5 93.4 93.9 94.0 94.2 1/2 load 50% 36.0 40.5 51.7 56.7 62.7 71.1 75.2 79.9 83.0 81.9 84.1 85.1 85.2 89.1 89.5 91.2 91.6 92.1 92.1 93.5 93.8 93.7 93.7 Current Power factor I N cos j A 0.67 0.62 0.57 0.62 0.76 0.79 0.77 0.82 0.78 0.76 0.79 0.79 0.75 0.79 0.79 0.85 0.84 0.84 0.83 0.83 0.84 0.83 0.85 0.25 0.37 0.46 0.62 0.72 0.96 1.41 1.65 2.4 3.3 4.6 6.3 8.8 11.2 15.3 20.7 28.4 34.8 41.7 56.5 68.3 83.9 99.8 Is IN 2.5 2.8 3.1 3.1 4.0 3.8 4.5 5.9 6.6 7.0 7.3 7.0 7.3 6.3 6.4 7.1 7.2 7.9 8.0 7.3 7.2 7.4 7.3 Torque TN Nm 0.42 0.62 0.81 1.24 1.74 2.5 3.8 5 7.3 9.9 14.4 19.8 26.4 35.8 49 71.7 97.9 120 143 194 238 290 355 Tl TN 2.2 2.9 2.7 2.5 2.0 2.0 1.8 2.6 2.9 3.1 2.8 2.4 3.1 1.9 1.8 2.6 2.7 3.1 3.0 2.7 2.6 2.8
IE2
Product code
Tb TN 2.2 2.9 2.8 2.6 2.1 2.2 2.2 3.2 3.2 3.5 3.4 3.0 3.4 2.6 2.6 3.0 3.6 3.6 3.8 2.9 2.9 3.0
Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA 2 kgm kg dB 0.00017 0.00018 0.00019 0.00026 0.00066 0.0008 0.0013 0.0016 0.0043 0.0048 0.009 0.011 0.0126 0.038 0.048 0.084 0.095 0.112 0.13 0.217 0.309 0.368 0.476 3.2 3.4 4 4.5 5.2 5.9 8.5 12 16 17 25 28 34 48 59 97 105 125 137 188 239 265 311 36 36 40 40 45 45 50 50 50 50 54 63 64 66 63 65 65 62 65 62 68 68 70
400 V 50 Hz
CENELEC-design
2.4 3.1
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 9
General performance aluminum motors Technical data for totally enclosed squirrel cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efficiency IEC 60034-2-1; 2007 Output kW Motor type 1000 r/min = 6 poles 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 M2AA 63 A M2AA 63 B M2AA 71 A M2AA 71 B M2AA 80 A M2AA 80 B M2AA 90 LB M2AA 90 LD M2AA 100 LC M2AA 112 MB M2AA 132 S M2AA 132 MB M2AA 132 MC M2AA 160 MLA M2AA 160 MLB M2AA 180 MLA M2AA 200 MLA M2AA 200 MLB M2AA 225 SMA M2AA 250 SMA 3GAA 063 001-C 3GAA 063 002-C 3GAA 073 001-E 3GAA 073 002-E 3GAA 083 001-E 3GAA 083 002-E 3GAA 093 213-E 3GAA 093 214-E 3GAA 103 212-E 3GAA 113 212-E 3GAA 133 211-E 3GAA 133 213-E 3GAA 133 214-E 3GAA 163 043-G 3GAA 163 044-G 3GAA 183 042-G 3GAA 203 043-G 3GAA 203 044-G 3GAA 223 042-G 3GAA 253 042-G Speed r/min 910 910 885 895 905 905 930 935 945 955 960 975 965 971 970 971 975 974 985 985 Full 3/4 load load 100% 75% 47.1 57.5 59.5 64.0 68.0 68.7 77.6 78.2 80.3 81.9 83.3 86.4 86.1 87.6 88.7 89.7 90.7 91.0 92.2 92.4 42.5 54.0 61.1 63.6 70.7 71.8 76.2 79.1 81.4 82.3 83.6 86.3 86.1 89.1 90.1 90.8 92.0 92.4 93.1 93.2 1/2 load 50% 32.1 46.2 56.5 59.5 68.3 69.7 75.6 76.5 80.7 79.8 81.7 84.0 84.3 89.0 89.9 90.5 91.9 92.5 93.1 93.0 Current Power factor I N cos j A 0.56 0.58 0.71 0.71 0.73 0.73 0.71 0.66 0.73 0.72 0.65 0.70 0.67 0.79 0.79 0.76 0.79 0.79 0.83 0.83 0.49 0.51 0.61 0.79 1.07 1.58 1.96 3 3.6 5.3 7.9 9.5 13.7 15.6 22.6 31.7 37.2 44.1 56.5 69.6 Is IN 2.1 2.1 3.1 3.3 3.6 3.3 4.0 4.2 3.9 5.2 4.3 7.3 6.2 7.1 7.6 7.8 6.2 5.8 6.9 6.6 Torque TN Nm 0.94 1.25 1.94 2.6 3.9 5.8 7.7 11.2 15.1 21.9 29.8 39.1 54.4 73.7 108 147 181 215 290 358 Tl TN 2.1 2.1 1.7 2.2 1.6 1.6 2.0 2.2 1.7 1.8 1.6 2.1 2.5 1.9 2.1 2.5 1.7 1.8 2.4 2.4
IE2
Product code
Tb TN 2.1 2.1 1.9 2.2 2.1 1.8 2.3 2.6 2.0 2.2 2.3 4.4 2.8 3.3 3.3 4.1 3.2 3.0 2.8 2.8
Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA 2 kgm kg dB 0.0002 0.00027 0.00092 0.0012 0.002 0.0026 0.0048 0.0056 0.009 0.01 0.031 0.045 0.049 0.089 0.119 0.137 0.198 0.222 0.532 0.718 4 4.5 5.5 6.5 9 10 18 20 26 28 39 54 59 105 121 139 173 187 265 305 38 38 42 42 47 47 44 44 49 56 57 57 61 61 61 61 65 65 65 66
400 V 50 Hz
CENELEC-design
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
10 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
Variant code Roller bearing at D-end. Heat resistant grease. Bearings regreasable via grease nipples SPM compatible nipples 63-series bearings in D-end Stainless steel / acid proof bolts. Light alloy metal fan Binding dimension drawing. Plugged existing drain holes. External earthing bolt. Heating element, 100-120V. Heating element, 200-240V. IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101).
71 NA M NA M M M M M M M M M
80 NA M NA M M M M M M M M M
90 NA M NA M M M M M M M M M
100 NA M NA M M M M M M M M M
112 NA M NA M M M M M M M M M
132 NA M NA M M M M M M M M M
160 M S NA M M M M M M M M M
180 M S NA M M M M M M M M M
200 M S NA M M M M M M M M M
225 M S NA M M M M M M M M M
250 M S NA M M M M M M M M M
280 M M S M NA M M M M S M M
315 M M S M NA M M M M S M M
355 M M S M NA M M M M S M M
Branch standard design Cooling system Documentation Drain holes Earthing bolt Heating elements
Mounting arrangements M M M M M M M M M M M M M M M M M M M M M M M M NA M NA NA NA M NA NA NA M NA NA NA M NA NA NA M NA NA NA M NA NA NA M NA NA NA M NA NA
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
M M M M S
Painting 114 005 072 076 002 095 135 159 161 331
1)
Special paint colour, standard grade. Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Draining holes with plugs in open position Restamping voltage, frequency and output, continuous duty. Restamping output (maintained voltage, frequency), intermittent duty. Mounting of additional identification plate, stainless. Additional plate with text Made in..... Additional rating plate delivered loose. IE1 motor not for sale for use in EU
Protection
Following variant codes are available, more information from ABB M = modifications NA = not applicable S = Standard
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 11
M2BA Code 122 435 436 441 445 230 400 447 Testing 145 148 701 704 Type test report from a catalogue motor, 400V 50Hz. Routine test report. Insulated bearing at N-end EMC cable gland. Variable speed drive NA M NA M NA M NA M NA M NA M NA M NA M NA M NA M NA M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M
1)
Variant code Bimetal detectors, break type (NCC), (3 in series), 150C, in stator winding. PTC - thermistors (3 in series), 130C, in stator winding. PTC thermistors (3 in series), 150C, in stator winding PTC - thermistors (3 in series, 130C & 3 in series, 150C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Standard metal cable glands 4x90 degr turnable terminal box Top mounted separate terminal box for monitoring equipment.
71
80
90
100
112
132
160
180
200
225
250
280
315
355
Terminal box
Following variant codes are available, more information from ABB M = modifications NA = not applicable S = Standard
12 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
1)
Variant Transport lock for bearings Roller bearing at D-end. Cold resistant grease Heat resistant grease. Bearings regreasable via grease nipples SPM compatible nipples for vibration measurement 63-series bearings in D-end Stainless steel / acid proof bolts. Cast iron D-end shield (on aluminum foot mounted motor). Metal fan cover Binding dimension drawing. Plugged existing drain holes. External earthing bolt. Heating element, 100-120V. Heating element, 200-240V. IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5) IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). Modified for specified mounting position differing from IM B3
56 NA NA NA M NA NA NA M NA NA M M M M M
63 NA NA M M NA NA NA M NA S M M M M M
71 NA NA M M NA NA NA M M M M M M M M
80 NA NA M M NA NA NA M M M M M M M M
90 M NA M M NA M M M M M M M M M M
Mounting arrangements NA NA M M NA M M M M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA M M M M M M M M M M M M M NA NA NA NA NA NA NA NA NA M M M M M M M M M M M M M NA NA NA NA NA NA NA M NA M M M M M M M M M M M M M M NA NA NA NA NA M M NA M M M M NA NA NA NA NA M M M M NA NA M NA NA NA M M NA M M M M NA NA NA NA NA M M M M NA NA M NA NA NA M M NA M M M M NA NA NA NA NA NA NA NA NA NA M M M M M M M M M NA M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA NA M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA NA M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA NA M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA NA M NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
(1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101) M Flange ring holder. Flange ring FT 85. Flange ring FT 100. Flange ring FF 100. Flange ring FF 115. Flange ring FT 115. Flange ring FF 130. Flange ring FT 130. Flange ring FF 165. Flange ring FT 165. Flange FF 165. Flange FT 165. Flange ring FF 215. Flange ring FT 215. Flange ring FF 265. Flange FF 265. IM 2001 foot/flange mounted, IEC flange from IM 3001 (B35 from B5)
Certain variant codes cannot be used simultaneously.
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
Following variant codes are available, more information from ABB M = modifications NA = not applicable S = Standard
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 13
M2AA Code 114 005 072 076 002 095 098 135 138 139 159 161 331 121 122 435 436 441 445 230 Testing 145 148 704
1)
1)
Variant Special paint colour, standard grade. Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Draining holes with plugs in position Restamping voltage, frequency and output, continuous duty. Restamping output (maintained voltage, frequency), intermittent duty. Stainless rating plate Mounting of additional identification plate, stainless. Mounting of additional identification plate, aluminum Additional identification plate delivered loose Additional plate with text Made in.... Additional rating plate delivered loose. IE1 motor not for sale for use in EU Bimetal detectors, break type (NCC), (3 in series), 130C, in stator winding Bimetal detectors, break type (NCC), (3 in series), 150C, in stator winding. PTC - thermistors (3 in series), 130C, in stator winding. PTC - thermistors (3 in series), 150C, in stator winding. PTC - thermistors (3 in series, 130C & 3 in series, 150C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Standard metal cable glands. Type test report from a catalogue motor, 400V 50Hz. Routine test report. EMC cable gland.
56 M M M S M M NA NA NA NA M M M
63 M M M S M M NA NA NA NA M M M
71 M M M S M M NA M NA NA M M M
80 M M M S M M NA M NA NA M M M
90 M M M S M M NA M NA NA M M M
Painting Protection
Terminal box
Following variant codes are available, more information from ABB M = modifications NA = not applicable S = Standard
14 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
General performance IE2 high efficiency motors Sizes 56 - 355 Dimension drawings
Foot-mounted motor IM1001, B3
M000418
IM 1001. IM B3 ja IM 3001. IM B5
Motor size D poles 2 4-6 56 63 71 80 90 S 90 L 100 112 132 1) 132 160 180 200 225 250 M2BA 71 80 90 100 112 132 160 180 200 225 250 280S 280SM_ 315SM_ 315ML_ 355SM_
2)
IM 1001. IM B3
L max poles 2 4-6 197 214 240 197 214 240 A B B C HD K H
IM 3001. IM B5
M N P S
GA poles 2 4-6
F poles 2 4-6 3 4 5 6 8 8 8 8 10 10 12 14 16 18 18 5 6 8 8 8 10 12 14 16 18 18 20 20 22 25 28
E poles 2 4-6 20 23 30 40 50 50 60 60 80 80 110 110 110 110 140 30 40 50 60 60 80 110 110 110 110 140 140 140 140 140 140 20 23 30 40 50 50 60 60 80 80 110 110 110 140 140 30 40 50 60 60 80 110 110 110 140 140 140 140 170 170 210
265.5 265.5 284.5 284.5 309.5 309.5 351 393 447 550 584 681 726 821 880 264 321 357 381 403 533 584 681 726 821 879 982 1052 1216 1330 1399 351 393 447 550 5843) 681 726 851 880 264 321 357 381 403 533 5845) 681 726 851 879 982 1052 1246 1360 1469
193.5 10
295.5 12
14.5 160 14.5 180 18.5 200 225 250 71 80 90 100 112 132
51.5 51.5 14
5254) 18 5724) 22 178 195 219 247 259 300 413 433 539 584 768 768 845 845 926 7 10 10 12 12 12
14.5 160 14.5 180 18.5 225 24 24 24 28 28 35 250 280 280 315 315 355
1)
51.5 51.5 14
79.5 18 79.5 18 85 85 18 18 20
74.5 106
S M5 M5 M6 M6 M8 M8 M8 M10
Tolerances A,B 0,8 D ISO j6 28 mm ISO k6 < 38 mm ISO m6 55 mm F ISO h9 H -0,5 N ISO j6 C 0,8
All types except M2A SC 2 pole, MC 6 pole 2) M2AA 132 SC 2 pole and MC 6 pole 3) 160MLB 6-pole L = 681 4) For voltage code S add 32 mm to listed HD-dimension 5) 160MLB 6-pole L = 681 6) 200, voltage code S HD = 478
Above table gives the main dimensions in mm. For detailed drawings please see our webpages www.abb.com/motors&generators or contact ABB.
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 15
Cable lugs, 6 terminals Polypropylene. Reinforced with 20% glass fibre. Steel Black RAL 9011 Phosphating pretreatment and polyester powder top coat 70m Copper Insulation class F 3 PTC thermistors as standard, 150C Diecast aluminum. Half key balancing Closed key way 8W IP 55 IC 411 Drain holes with closable plastic plugs, open on delivery. Bolted to the stator 25 W
16 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
160
180
200
225
250
Cast iron EN-GJL-200/GG 20/GRS 200 Munsell blue 8B 4.5/3.25 / NCS 4822 B05G Two-pack epoxy paint, 70m Integrated with stator Cast-iron EN-GJL-200/GG 20/GRS 200 Cast iron EN-GJL-200/GG 20/GRS 200 Munsell blue 8B 4.5/3.25 / NCS 4822 B05G Two-pack epoxy paint, 70m 6209-2Z/C3 6209-2Z/C3 V-ring V-ring Permanently lubricated shielded bearings. Cast iron, base integrated with stator. Two-pack epoxy paint, 70m Steel 8.8, zinc electroplated and chromated (2 x M40 + M16)*) 35 6 terminals for connection with cable lugs (not included) M6 Polypropylene. Reinforced with 20% glass fibre. Hot dip galvanized steel Black, NCS 8801-B09G Polyester powder paint, 70m Copper Insulation class F 3 PTC thermistors as standard, 150C Diecast aluminum Half key balancing Closed key way M10 (2 x M63 + M16) 70 6210-2Z/C3 6209-2Z/C3 6212-2Z/C3 6209-2Z/C3 6213-2Z/C3 6210-2Z/C3 6215-2Z/C3 6212-2Z/C3
Material
On request
25 W IP 55 IC 411
50 W
Drain holes with closable plastic plugs, open on delivery. Integrated with the stator
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 17
18 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
Polyester powder paint, 60m 6204-2Z/C3 6205-2Z/C3 6306-2Z/C3 6306-2Z/C3 6208-2Z/C3 1) 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3 D-end
10
3)
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 19
20 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
Notes:
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 21
Total offer of motors, generators and mechanical power transmission products with a complete portfolio of services
ABB is the leading manufacturer of low, medium and high voltage motors and generators, mechanical power transmission products with an offering of a complete portfolio of services. Our in-depth knowledge of virtually every type of industrial processing ensures we always specify the best solution for your needs.
Cast iron frame (TEFC) Air to air cooled (TEAAC) motors Motors and generators for explosive atmospheres IEC and NEMA motors and generators, for all protection types Synchronous motors Synchronous generators Synchronous generators for diesel and gas engines Synchronous generators for steam and gas turbines Wind power generators Generators for small hydro Other motors and generators Brake motors DC motors and generators Gear motors Marine motors and generators Single phase motors Motors for high ambient temperatures
Permanent magnet motors and generators High speed motors Smoke extraction motors Wash down motors Water cooled motors Generator sets Roller table motors Servo motors Traction motors Life cycle services Installation and commissioning Service contracts Preventive maintenance Spare parts Diagnosis Repair and refurbishment Site survey and overhaul Replacement motors and generators Technical support and consulting Trainings Mechanical power transmission components, bearings, gears
Low and high voltage IEC induction motors Process performance motors General performance motors High voltage cast iron motors Induction modular motors Slip-ring modular motors Synchronous reluctance motors Low and medium voltage NEMA motors Steel frame open drip proof (ODP) motors Weather protected, water cooled, fan ventilated
22 Low voltage General performance IE2 high efficiency motors according to EU MEPS | ABB Motors and Generators
Products Motors and Generators > IEC low voltage AC motors >> General performance motors Process performance motors >>> IE2 high efficiency cast iron motors >>> IE2 high efficiency aluminum motors >>> IE1 standard efficiency cast iron motors >>> IE1 standard efficiency aluminum motors Brake Motors High Ambient Temperature Motors Marine Motors Permanent Magnet Motors Roller Table Motors Single phase motors Smoke Extraction Motors Water Cooled Motors
ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors according to EU MEPS 23
Contact us
We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2013 ABB. All rights reserved.
9AKK105789 EN 01-2013
www.abb.com/motors&generators
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility what so ever for potential errors or possible lack of information in this document.