Sunteți pe pagina 1din 2

SCHMIDT Flow Sensor SS 30.

30X

Poduct description Flow sensor for volume flow measurements in compressed air and gases with integrated LED display and two configurable signal outputs. Configurable with two buttoms. Selectable indication of flow rate, total flow, temperature, measuring units and attenuation. Selectable signal outputs for switching outputs or analog/impulse outputs.

Applications n Consumption measurement of compressed air n Inert gas flow measurement n Consumption measurement of compressed air tools n Consumption measurement of compressed air driven machines

Advantages n Easy installation n Direct measurement fo normal volume flow n Very low pressure loss n LED display for flow rate, total flow, temperature and configuration

Technical data
Technology / design Measuring range (F.S) thermal inline flow sensor 0.2576.3 normal m3/h (SS 30.300) 0.8 229 normal m3/h (SS 30.301) 1.5 417 normal m3/h (SS 30.302) 3.0 712 normal m3/h (SS 30.303) (at 20 C and 1013.25 hPa) (3 % of m.v. + 0.3 % of full scale) (air quality class 141 or 344) 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1 s default: 0.6 s 2 C (maximum volume flow) unidirectional clean air, nitrogen. Other gases on request air quality class 141 oder 344 (according DIN 8573-1) 90 % medium: electronics: inside: length: 0 +60 C 0 +60 C 16.1 mm 51 mm 300 mm 475 mm 16 bar Pipe dimensions (depending on version) Output 1 (OUT 1) switchable to Output 2 (OUT 2) switchable to Configuration switching output Layout digital output (switch & impulse) Working resistance Display Supply voltage UB Current consumption Electrical connection Protection class Material housing Material sensor element Material tube outside: connection: switching output impulse output switching output 4 ... 20 mA switching values / range / hysteresis opener / closer PNP (highside-driver at UB) 250 mA; voltage drop < 2 V 500 4 digits LED display 7 segments, 7mm, red 19 30 V DC < 100 mA (without output load) plug 4 pins, M12 IP 65 PBT, glas fibre reinforced ceramics, glass passivated stainless steel 1.4301 DN 15 DN 50 male thread R R2

Accuracy flow Attenuation (dAP)


Form 1082/ 06/09/ 1000 /6 Art.-Nr. 522861.02 A Data subject to change

Response time (dAP = 0 s) < 0.1 s Accuracy temperature Measuring direction Medium Medium resistance Maximum pressure Relative humidity Operating temperature Pipe dimensions (depending on version)

SCHMIDT Technology GmbH Feldbergstrae 1 78112 St. Georgen im Schwarzwald Germany Telefon +49 (0) 77 24 / 8 99 - 0 Fax +49 (0) 77 24 / 8 99 - 1 01 info@schmidttechnology.de www.schmidttechnology.de

SCHMIDT Flow Sensor SS 30.30X

Drawing and dimensions

111 100

Programming buttons LED display, 4-digits

45

DA

M12x1

DI

Flow
120 L in L

Dimensions Sensor SS 30.300 SS 30.301 SS 30.302 SS 30.303 Length L [mm] 300 475 475 475 Inlet Path Lin [mm] 210 375 275 275 Outer Diameter DA [mm] 21.3 33.7 42 54 Inside Diameter DI [mm] 16.1 27.3 39 51 Height H [mm] 76.8 88.5 120 133 Connection R R R1 R1 R2

Order information SS 30.300 76.3 normal m3/h SS 30.301 229 normal m3/h SS 30.302 417 normal m3/h SS 30.303 712 normal m /h
3

Order number 508 520 508 521 508 522 508 523

Accessories (please order separately) Connection cable (5 m) Connection cable (10 m) Female connector, 4 pins, without cable with screw terminal Power supply 24 V DC, 115 / 230 V AC, terminal block, short circuit protected mounting on rail ISO calibration certificate SS 30.300 6 calibration points ISO calibration certificate SS 30.301 6 calibration points ISO calibration certificate SS 30.302 8 calibration points ISO calibration certificate SS 30.303 8 calibration points

Order number 300 722-1 300 722-2 301 008

300 838 510 356-1 510 356-2 510 356-3 510 356-4