Sunteți pe pagina 1din 2

3791652900

CellD 300
Power system
Description
CellD systems are small, just like cells. They can be embedded in the telecom infrastructure and are often used in OutD outdoor solutions. The products in this series are light and designed especially for installations with limited space offering high density of the installed power. The system includes high efficiency rectifiers, AC and DC connections, battery connection and either Delta PSC 3 or CSU 502 controller. In addition to advanced supervision, short depth and easy installation are the success factors of the system. Delta is known for quality and product reliability in this solution that has been combined to optimize the total cost of ownership.

Main features
19in rack mounted system up to 17.4 kW Integrated 3U distribution unit + rectifiers shelf 1U 3U High efficiency rectifiers up to 96,2 % All connections easily accessible from the top All battery and load breakers accessible at the front Sliding mechanism to support easy access to the output connections Option for enhanced monitoring and controlling

Applications
Wireless applications, network base stations, LTE Fixed line applications, broadband services Transmission

3791652900

CellD 300
Power system

Technical specifications
DPS 1600B-48-9 CellD 300 Rectifier module Efficiency Install power (max. config.) Input current (per 1 phase) Input protection (recom.) Height (overall) Width (body) Depth (body) Weight AC input AC configuration Input voltage range Frequency range Mains connection Input protection 3 x (L + N + PE) or 3L + N + PE 80 300 VRMS 45 - 66 Hz Cable / Screw terminals N loss, Internal OVP, Inbuilt fuses (L+N), High input voltage Remote monitoring DPR 1600B-48 (max. 9 pcs.) 92 % 14.4 kW 19 ARMS (2 shelves) 2 x (3 x 20 A) 266 mm (3U + 3U) 444 mm (19) 280 mm 25 kg DPS 2400B-48-5 CellD 300 DPR 2400B-48 (max.5 pcs.) 94 % 12 kW 30 ARMS 3 x 32 A 177 mm (3U + 1U) 444 mm (19) 415 mm 20 kg Control / Monitoring Controller Local interface PSC 3 or CSU 502 Display, menu structure, keypads, LEDs 6 alarm relays, modems, WEB Interface, SNMP protocol DPS 2900B-48-6 CellD 300 DPR 2900B-48 (max. 6 pcs.) 96.2 % 17.4 kW 32 ARMS 3 x 40 A 222 mm (3U + 2U) 444 mm (19) 310 mm 20 kg

Others Operating temperature -45 - +65 C 95 % max, non cond. ETSI EN 300 019-1-3 IEC 60950 EN 300 386

DC output Output voltage range Output current (max.) Load breakers Battery breakers LVD (battery) PLD (not critical loads) Critical / non critical loads configuration Output protection 42-58 VDC; 53.5 VDC nom. 250 A 16 x MCB 6 x HMCB (up to 100A) 3 x HMCB (up to 200A) 2 x HMCB (up to 300A) 250A (standard) 250 A (option) 7 x MCB + 9 x MCB (option) Inbuilt fuses (both poles) High output voltage Over-temperature protection

Humidity (relative) Environment standard Safety standard EMC standard Ordering System Rectifier DPR 1600B-48 Rectifier DPR 2400B-48 Rectifier DPR 2900B-48

3791467500 TPS1010001B TPS1010002A ESR-48/56B F-S

Delta Energy Systems (Finland) Oy Juvan teollisuuskatu 15, FIN-02921 Espoo Phone: +358 9 849 660, Fax: +358 9 8496 6100 www.deltapowersolutions.com
Fact_sheet_CellD_300_en.doc / Rev. 00 / RP