Assembly Instructions:
What you need - Not included in kit
TOOLS PARTS
•• Electric or Battery powered Drill/Driver •• Garden hose(s) to connect wall to spigot.
•• Drill Bit – 1/4” •• 14-16 fasteners/anchors for attachment of
•• 7/16” Wrench VertiRail Furring Strips and HideAway Brackets to
wall (See page 14 for Fastener Recommendation)
•• Level
•• Wood or metal to cover irrigation chase and
•• Tape Measure associated fasteners.
•• Pencil •• 2 - AA Batteries
•• Utility Knife or Pipe Cutter
Also Recommended
•• Eye Protection
•• Gloves •• Flashing Tape (for sealing the anchors drilled
into the building wall)
•• Non-PTFE Thread Sealant
Also Recommended
•• Drill Bit - 3/16”
•• Stud Finder
•• Ladder or Scaffold
•• 2 C-Clamps - preferably quick release
Brass Swivel Coupler - The first connects Irrigation Screen Filter - Connects to
the close nipple to the hose. The second hose timer using brass swivel coupler.
connects the hose timer to the screen Filters unwanted particles to prevent
filter. clogging.
WallTer™ Inserts - Dropped into wall WallTer™ Wall Planters - Dropped into
planters, hold plants and soil. RainRail slots, hold planted inserts.
Half (8”) and Full (16”) sizes included. Half (8”) and Full (16”) sizes included.
16” 16”
Wall stud
Furring Strip
H-Rail
Furring Strip
Slot Rail
(without
nozzle holes)
BOTTOM
RainRail
(with
nozzle holes)
Fastenening
12”
Screw
12”
GapTool
12”
•• On the side which you want to feed irrigation, push the LightBlock Elbow onto the smooth end of a RainRail
Adapter, and insert the double-o ring end of the RainRail Adapter into the end of the top RainRail.
•• Push 1” x 10 5/8” section of pipe into the LightBlock Elbow.
•• Push LightBlock Tee onto a RainRail Adapter, insert top end of Tee into previously installed section of pipe, and
insert RainRail Adapter into end of second RainRail. Insert another piece of 1” x 10 5/8” pipe onto bottom end of
Tee. Repeat this step for all RainRails.
•• Secure all RainRail Adapters with set screws.
•• Cut 42” pipe to desired length, and push onto the bottom end of
the lowest LightBlock Tee. The pipe may extend as far down from the
wall as desired; however, at least 1 foot distance from pipe to ground LightBlock
is needed. Then, push 1” Light Block Male Adapter onto end of pipe Elbow
toward ground. RainRail Adapter
•• Insert RainRail End Plugs to all RainRails on the opposite side
to 1” LightBlock
(the side without irrigation) and secure with set screws.
RainRail
Endplug
RainRail Adapter
to 1” LightBlock LightBlock
Tee
H-Rail without
nozzles Cut 42” pipe
to desired length
Push Adapter (Light-
Block 1” Male) onto
Cut Pipe
Adapter (LightBlock
1” Male)
Reducer Coupling
Brass Swivel
Coupler
•• Starting at the spigot, connect the top end of the Hose Timer. Install two AA Batteries in Hose Timer.
•• Attach Hose Timer to Brass Swivel Coupler.
•• Screw the Screen Filter into the Brass Swivel Coupler. Ensure that ARROWS ON THE SCREEN FILTER POINT IN
DIRECTION OF WATER FLOW / HOSE.
•• Screw the Brass Adaptor onto the Screen Filter. Wrap Brass Adapter threads and attach to Garden Hose.
.2 gpm .2 gpm
.1 gpm .1 gpm
•• Install perimeter HideAway brackets Space HideAway brackets close enough together to provide sufficient
support for facing against wind pressure.
•• Space brackets no greater than 24” on center.
•• Install trim boards (not included) onto HideAway Brackets.
1-1/2”
Centerline
12” HideAway Brackets
12”
•• FOR GREATEST EFFICIENCY, install Wall Planters from RIGHT TO LEFT due to overlapping lip orientation.
»» Install top row first, beginning with a 16” wide wall planters.
»» Planters in the first row are all 16” wide planters.
»» Push the top edge of the planter into the RainRail slot above it, and then drop the bottom edge down into
the lower RainRail slot.
»» The second row is installed beginning with an 8” wide WallTer module on the right hand side. This is
followed by a series of 16” modules, and ends with another 8” module.
•• Install WallTer Limiting Screw in score line toward top of WallTer module. (Optional for theft or wind resistance)
For Plant and Soil Selection and Planting Instructions, see the LIVEWALL PLANTING GUIDE (enclosed).
•• Install WallTer™ Inserts into the WallTer wall planters.
•• Run irrigation system for a couple of minutes to settle soil and prevent plant material from wilting.
•• Set hose timer to recommended irrigation settings listed in included LiveWall Maintenance Protocol, included.
FOLLOW THE LIVEWALL MAINTENACE GUIDE (enclosed) in caring for your plants and system.
Below are fastener recommendations for different structural applications based on 18 pounds per square foot .
Brick Torx Hex Washer Head Screw 1/4” x 1-3/4” 1/4” N/A HILTI KWIK-CON II+1/4” x 1-3/4”
Anchor THWH St Steel
ITW Red Head Tapcon Screw 1/4” x 1-3/4” 1/4” N/A Fastenal 0131211 1/4” x 1-3/4” Hex
Anchor Washer, Hex Drive, St Steel
Poured Walls Torx Hex Washer Head Screw 1/4” x 1-3/4” 1/4” N/A HILTI KWIK-CON II+1/4” x 1-3/4”
- Page 14 -
Anchor THWH St Steel
ITW Red Head Tapcon Screw 1/4” x 1-3/4” 1/4” N/A Fastenal 0131211 1/4” x 1-3/4” Hex
Anchor Washer, Hex Drive, St Steel
Steel Studs Ballistic Point, Single Fastener 0.157 - 1” N/A N/A HILTI X-U 27 P8 TH
Metal “Tophat” & 8mm Plastic
Aluminum Studs Ballistic Point, Single Fastener 0.157 - 1” N/A N/A HILTI X-U 27 P8 TH
Metal “Tophat” & 8mm Plastic
Wooden Studs Hex Lag Screw 1/4” x 1-1/4” 1/4” N/A HILTI 3-WD-1/4”-20 x 1-1/4” HWH Lag
Screw, Galvanized
Hex Lag Screw 1/4” x 1-1/4” 1/4” N/A Fastenal 22087 1/4” x 1-1/4” Hex Head
Lag Screw, Galvanized
Exterior Varies Varies Varies Varies Varies Varies Fasten through EFIS to Structure Below
Insulation
rev. 11-APR-2017
Finishing System
(EIFS)
method should be pre-approved with the manufacturer to
LiveWall Disclaimer/Limitation of ensure that it is suited for use in conjunction with the
LiveWall system. LiveWall accepts no liability for any
Remedies and Liability for LiveWall and issue related to construction components, moisture
LiveScreen Modular Green Wall System barrier systems or bonding methods. The waterproofing
This disclaimer/limitation of remedies and liability applies system manufacturer should always be consulted before
applying any type of green wall system. LiveWall
to all LiveWall modular planted living wall products and
accepts no liability for moisture, mold, mildew, insects or
LiveScreen and LiveFence products manufactured and
sold by LiveWall, LLC under the name of LiveWall, animals.
LiveScreen or LiveFence. No person representing or
purporting to represent LiveWall, LLC shall be entitled to Limitation of Remedies and Liability
waive or vary the terms set forth herein, and any attempt If the product is proved to be defective, the exclusive
to do so shall be void and of no effect. remedy, at LiveWall, LLC’s option, shall be to refund the
purchase price of the WallTer container (exclusive of soil
Warranty and plant material) or to timely repair or supply of
replacement containers (exclusive of soil and plants).
The LiveWall WallTer module is warranted against
LiveWall, LLC shall not otherwise be liable for any loss
material defects and photo degradation for 15 years from
or damages, whether direct, indirect, special, incidental,
the date of installation. The RainRail™ mounting bracket
punitive, or consequential, regardless of the legal theory
is warranted against material defects for 15 years from
asserted, including negligence, warranty, or strict
date of installation. Color of WallTer planters MAY
liability.
lighten with exposure to U.V.
If LiveWall, LLC shall elect to repair or replace the
Suitability/Particular Applications defective product, or refund the purchase price
Because LiveWall, LLC does not have control over each (exclusive of soil and plants), such election shall not be
particular application of its products, LiveWall makes no deemed an admission of liability. Any lawsuit or legal
warranties express or implied related to the fitness action against LiveWall, LLC with regard to product must
of LiveWall products for particular applications and be brought in Ottawa County, Michigan, and Michigan
or purposes. It is the responsibility of the user to law shall apply to all proceedings.
determine whether the product is suited to a particular
purpose or application, and LiveWall, LLC recommends Plant Grades and Standards
consultation with a competent architect or engineer to
The LiveWall system is intended to be delivered in
determine if the LiveWall system is suitable for particular
conjunction with empty or vegetated WallTer™ Inserts.
conditions related to but not limited to wall design,
The plants are to be an assortment of plants that is
sun/shade orientation, potential of wind damage, and
suitable for the intended purpose. They may be annuals,
propensity for mold/mildew. LiveWall does not assume
perennials, long lived succulents, herbs, vegetables,
any liability for damage or injury resulting from system
medicinals, or tropical plants. Any warranty for
component, stationary or falling, or from soil, plant
vegetation must come from the local LiveWall®
matter, snow, ice, etc., or components of the LiveWall
Grower/Distributor or maintenance provider. Any such
system falling or dislodging from an installation, or from
warranty may vary from grower to grower (independent
injury due to anyone climbing upon the LiveWall system.
Furthermore, LiveWall, LLC assumes no liability for of LiveWall, LLC). Typically plant warranties from
slippery or wet surfaces under or around its growers are associated with additional charges and the
products. adherence to and documentation of specific
maintenance practices.
LiveWall, LLC makes no warranty that products
The LiveWall system is intended to be supplied with
installed by installers have been installed properly or in
LiveWall’s LiveSoil™ engineered soil, in accord with
accordance with LiveWall standardized installation
procedures. Any warranties for product installation established specifications. Significant deviation from
such specifications may result in suboptimal
and related work are available solely from the actual
performance, and resultant performance is solely at the
installer.
discretion and responsibility of the system owner.
LiveWall reserves the right to modify its soil formulations,
Vegetated walls typically keep wall membranes wetter
formulate by subcontractor, or adapt formulations
than traditional walls. This is an important consideration
regionally based upon climate, water quality, codes, and
when determining what type of membrane and bonding
regionally available materials.
agent/method to use. The choice of moisture barrier
(breathable membrane or otherwise) and bonding