Sunteți pe pagina 1din 2

IEEE.

org | IEEE Xplore Digital Library | IEEE Standards | IEEE Spectrum | More Sites For Institutional Users:
Institutional Sign In Athe ns/Shibbole th

Brow se Journals & Magazines > Neural System s and Rehabilita ...> Volum e:20 Issue:2

| Back to Results |

Dry and Noncontact EEG Sensors for Mobile BrainComputer Interfaces

Full Text
Sign-In or Purchase

Author(s)

Chi, Y.M. ; Dept. of Electr. & Comput. Eng., Univ. of California-San Diego, La Jolla, CA, USA ; Yu-Te Wang ; Yijun Wang ; Maier, C. more authors

Abstract

Authors

References

Cited By

Keywords

Metrics

Similar

Dry and noncontact electroencephalographic (EEG) electrodes, which do not require gel or even direct scalp coupling, have been considered as an enabler of practical, real-world, brain-computer interface (BCI) platforms. This study compares wet electrodes to dry and through hair, noncontact electrodes within a steady state visual evoked potential (SSVEP) BCI paradigm. The construction of a dry contact electrode, featuring fingered contact posts and active buffering circuitry is presented. Additionally, the development of a new, noncontact, capacitive electrode that utilizes a custom integrated, highimpedance analog front-end is introduced. Offline tests on 10 subjects characterize the signal quality from the different electrodes and demonstrate that acquisition of small amplitude, SSVEP signals is possible, even through hair using the new integrated noncontact sensor. Online BCI experiments demonstrate that the information transfer rate (ITR) with the dry electrodes is comparable to that of wet electrodes, completely without the need for gel or other conductive media. In addition, data from the
0
Like

noncontact electrode, operating on the top of hair, show a maximum ITR in excess of 19 bits/min at 100% accuracy (versus 29.2 bits/min for wet electrodes and 34.4 bits/min for dry electrodes), a level that has never been demonstrated before. The results of these experiments show that both dry and noncontact electrodes, with further development, may become a viable tool for both future mobile BCI and general EEG applications.

0
Tw eet

0
Share

Published in: Neural Systems and Rehabilitation Engineering, IEEE Transactions on (Volume:20 , Issue: 2 ) Date of Publication: March 2012
Page(s): 228 - 235 ISSN : 1534-4320 INSPEC Accession Number: 12615336 Digital Object Identifier : 10.1109/TNSRE.2011.2174652 Date of Publication : 12 December 2011 Date of Current Version : 19 March 2012 Issue Date : March 2012 Sponsored by : IEEE Engineering in Medicine and Biology Society PubMed ID : 22180514

Sign In | C reate Account

IEEE Account
C hange Username/Password

Purchase Details
Payment Options

Profile Information
C ommunications Preferences

Need Help?
US & Canada: +1 800 678 4333

Update Address

Order History Access Purchased Documents

Profession and Education Technical Interests

Worldwide: +1 732 981 0060 C ontact & Support

About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology. C opyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.

S-ar putea să vă placă și