Sunteți pe pagina 1din 6

Roofs and Faades PRODUCT RANGE

TRIMOTERM FTV FIREPROOF FAADE PANELS


Trimoterm FTV
Trimoterm FTV fireproof panels are used for a wide range of external faade cladding, internal partition walls, fire walls and ceilings for either leisure, commercial, industrial, hygenic and other facilities. Panels can be installed in either vertical or horizontal orientation.
An example of panel marking:

Trimoterm FTV

Side A

FTV ms-60/1000
Width Thickness Side B Side A V - profile S - profile (standard profile) Side B

Profile Type S - profile (s) V - profile (v)


Smooth profile

Side A

Side B

Smooth profile (g, G) Micro-lined profile (m) Multi vario (X)

Micro-lined profile

Multi vario profile EN 14509:2006

Side A is usually the external side of a panel. Thickness selection for the panels: 50, 60, 80, 100, 120, 150, 172, 200, 240 mm. Non-standard panel widths can be made by special request. Panel lengths range up to 14 m.

Trimoterm FTV INVISIO


Trimoterm FTV INVISIO fireproof faade panels shows its outrange clean facade outlook with no visible fixings while fixing on intermediate cladding rails is performed through a panel side lap joint by special developed supporting elements. Panels are mainly intended for vertical type of cladding but under certain conditions and limitations can also be used for various horizontal cladding applications.
An example of panel marking:

Trimoterm FTV INVISIO


Width

FTV H ms-60/1000
Thickness Side B Side A Invisio S - profile (standard profile)

Side A

Side B

Tipe of profile
V - profile

Side A

Side B

S - profile (s) V - profile (v) Smooth profile (g, G) Micro-lined (m) Multi vario (X)

Smooth profile

Micro-lined profile

Multi vario profile

Side A is usually the external side of a panel. Thickness selection for the panels: 60, 80, 100, 120, 150, 172, 200 mm. Non-standard panel widths can be made by special request. Panel lengths range up to 14 m.

EN 14509:2006

Trimoterm FTV GLADIO


Trimoterm FTV GLADIO faade panels are COMPLETELY and OPTICALLY FLAT. The outer, visible side of steel sheet is manufactured using a special high technology process that ensures an optimal flat surface. For further possibilities of the internal facing see Trimoterm FTV and INVISIO.
Side A An example of panel marking:

FTV Gs-60/1000
Width Thickness Side B Gladio

Side B EN 14509:2006

Trimoterm FTV MULTI VARIO


Trimoterm FTV MULTI VARIO

Side A

Side B

The basic model of the MULTI VARIO panel is the enlarged micro profile. For further possibilities of the internal facing see Trimoterm FTV and INVISIO.

An example of panel marking:

FTV X 21 s-60/1000
Width Thickness Side B

A wide variety of profile possibilities can be derived from the basic model; these are combinations of the flat and enlarged micro profiles. Some possibilities are presented in the sections below.
8 5 8 5 3 17 18 20 24 24 29 29 3 17 18 20

Profile number Multi vario

21

21

EN 14509:2006

Trimoterm FTV ACOUSTIC PANEL


Acoustic sound absorbing panels are used for sound damping in internal applications only. They can be erected as cladding of sound-absorbing cabins, as partition walls and additional cladding on faades and roofs.
Side A

An example of panel marking:

FTV ss-60/1000-ac
Acoustic Width Thickness

Side B

Side B Side A

TRIMOTERM SNV FIREPROOF ROOF PANELS


Trimoterm SNV, SNV-3L
Trimoterm SNV fireproof panels are mainly used with additional sealing of longitudinal joints for roof cladding however they can also be used for the wall clading. Minimum roof slope is 3 with additional sealing of longitudinal joints. Trimoterm SNV
Side A An example of panel marking:

SNV s-60/1000
Width

Side B

Thickness Side B

Trimoterm SNV-3L
Side A

An example of panel marking:

Side B

SNV-3L s-60/1100
Width Thickness Side B

Trapezoid profile

Trapezoid profile 3L 37,3 S - profile (standard profile)

Profile Type Trapezoid S - profile (s) V - profile (v) Smooth (g)

Side A

Side B

V - profile

Smooth profile

Thickness selection for the panels 60, 80, 100, 120, 150, 172, 200 mm. Panel lengths range up to 14 m.
EN 14509:2006

Trimoterm SRV
Trimoterm SRV Panels are used for flat roofs (min. roof slope 2 %).
Folia PVC An example of panel marking:

SRV-60/1000
Width Thickness

Thickness selection for the panels 60, 80, 100, 120, 150, 200 mm. Panel lengths range up to 14 m.
EN 14782:2006

Calculation of allowed spans is by the SandStat program


FM 4880 for internal use
Cert. No. 650a to LPS 1208

Rights to alteration reserved. The last version of the document is available on www.trimo.si. For information about the delivery of panels see Trimos General conditions and the valid price list.

TRIMOVAL PROFILED SHEET METAL


Trimoval TE 600
Profiled steel sheet TE 600 is used for the assembly of floor constructions under commercial name HI-BOND.

Trimoval TP 650, TPF 650 and Trimoval TP 835, TPF 835


Profiled steel sheet types TP650 and TP 835 are intended for roofing and cladding of un-insulated buildings, or ventilated roofs and faades.

EN 14782:2006

TPF is trapezoid sheet metal with felt. Panel lengths range up to 8.5 m.

Trimoval TPO 1000


TPO 1000 is intended for roofing and cladding of un-insulated buildings or as a form of ventilated roofs and faades.

EN 14782:2006

Panel lengths range up to 14 m.

Trimoval TPO Dom


TPO Dom roofing is installed in bands from the ridge to the eaves in a single section. TPO Dom is intended for the roofing of either new or reconstruction of old residential buildings.

Panel lengths range up to 14 m.

EN 14782:2006

Published by: TRIMO d.d., Design: Meta Gabrijel, Edvin Nepulan, Photography: Janez Erjavec, Miran Kambi, Bernd Theisen, Archive Trimo, Circulation: EN, 01/2010

S-ar putea să vă placă și