Sunteți pe pagina 1din 22

Product line E11

E11

New! New!

Circuit protection system

ETI Elektroelement d.d.


Obrezija 5, SI - 1411 Izlake
Slovenia
Phone: + 386 03 56 57 570
Fax: + 386 03 56 74 077
eti@eti.si
www.etigroup.eu

PRODUCT LINE
E11

Miniature circuit breakers

Miniature circuit breakers ETIMAT11


Advantages of miniature circuit breakers ETIMAT11
Sealing
cover

Sealing
possibility
ON/OFF mark
on the switch button

Locking
device

Better protection
of terminals against
touching the parts
under voltage

New method of
mounting on the
DIN rail and simple
replacement
Double connection
possibility
Every product is
marked with EAN code

Option of mounting auxiliary


devices (auxiliary switch, shunt
trip)

PRODUCT LINE
E11

Miniature circuit breakers

PS/SS Auxiliary signal switch for ETIMAT11


A device which can either be set up as an auxiliary switch or a signal switch; depending on
the setting selected, this device may be used for remote indication of the current switching
status of a switching device in the type series ETIMAT11 MCB.
Auxiliary switch = contact position indication
Signal switch = indication device tripped on fault occurrence
This switch may be used as a potential-free break/make or break/change-over contact.
Even in an assembly, all terminals are easily accessible from above.

Installation and operation:


This switch is mounted together with the switching device on the support rail. If required,
therefore, both may be removed together from the assembly and replaced.
Before fitting, the universal auxiliary switch will be set to the desired function auxiliary
switch or signal switch by turning the adjusting-screw, marked by an appropriate label
(fig.1)
On the relevant switching device, an aperture for the tripping pin is provided; this
aperture is broken out (fig. 2)

Auxiliary switch PS/SS E11


type
contacts
PS/SS E11
1xNC, 1xNC/NO
NC - normally closed contact
NO - normally opened contact

Connection to the switching device is effected by two retaining clamps, operation is


effected via the tripping pin or the connecting piece to the toggle switch (fig. 3)
For test purposes, the universal auxiliary switch (in assembled condition) may be operated
without actuation of the switching device. To this end, the connecting pin to the protective
switching device toggle is withdrawn; then, using a small screwdriver, activate the function
TEST of the auxiliary switch (fig.4)

Fig.1

Fig.2

Fig.3

Fig.4

ETIMAT11 RC - Remote control


ETIMAT11 RC is a miniature circuit breaker with remote control mechanism.
ETIMAT11 RC provides following advantages:









remote switching with simultaneous protection


minimal space requirement
straightforward actuation
can be used as actuator in any instalation bus system
secure against remote activationafter manual switch-of and/or being tripped by
overcurrent
control coil protected against thermal overload
easy instalation assured by rapid fastening method
visual status display : red/ON, green/OFF
sealable control lever
capability of adding an auxiliary switch

Technical Data:

the remote control mechanism, which serves to actuate ETIMAT11 RC is conected to


Etimat11 MCB by the factory before dispatch
the remote control mechanism is activated electro-magneticaly by the application of
a control voltage acc. to following data:
rated voltage:
230V a.c.
exciting current:
approx 1.5A, duration min 20msek

No. of operations:

20.000 , max 12 per minute

PRODUCT LINE
E11

Miniature circuit breakers

ETIMAT11 QC - Quick connect

Use rigid wire

Connecting the wire

with cross section from 1,5 to 4 mm2

Voltage test

Disconnecting the wire


- press the button

PRODUCT LINE
E11

Miniature circuit breakers

Miniature circuit breaker ETIMAT11 Characteristics


I/t characteristics at 50 and 60Hz

min.

1min.

1min.
4

10s

10s

6
4

6
4
2

1s
6

1s
6

sek.

100ms

100ms

10ms

10ms

6
1

1.5

NxI

10

20

30

1.13 1.45

min.

100

10

2
1min.

10s

10s

6
4

1s
6

1s
6

100ms

100ms

10ms

10ms

6
3

NxI

10

20

30

10

20

30

10

20

30

1.05 1.2

NxI

6
4

1.5

10

120

1min.

1.5

min.
t

10

100

sek.

1.13 1.45

100

10

1.13 1.45

sek.

sek.

min.

100

1.5

NxI

n
5

Miniature circuit breaker ETIMAT11 Characteristics


Effect of the ambient temperature on the tripping characteristic
70

Corection factor is valid for current with times over 30 s


I(xC) - test current at x ambient temperature
I(30C) - test current at 30C ambient temperature

T/ C

60

50

In
[A]
0,5
1
1,6
2
4
6
10
13
16
20
25
32
40
50
63

40

30

20

10

-10

-20

I(xC)

-30

-40

k= ----------------I(30C)

0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5

10

-40
0,61
1,22
1,95
2,44
4,88
7,32
12,2
15,9
19,5
24,4
30,5
39
48,8
61
76,9

6
2

B63

10

B50

B40
B32

B25
B20

B16

B10
B13
4

2
2

Ip/A

B6

C50
C40
C32
C25
C20

C16
C10
C13

10

C63

C6

10 3

1.5

2.5

10

9 10 4

10 3

1.5

Prospective current I p (A)


10
2

I t/As

9 10 4

Ip/A

10

D32

D25
D20

4
3

D16
D10
D13
D6

Max. operating I t (A s)

2
2

2.5

9 10 4

K16
K10
K13

1.5

K25
K20

10 3

K32

10

Prospective current I p (A)

I t/As

Ip/A

2.5

Prospective current I p (A)

10

70
0,38
0,75
1,2
1,5
3
4,5
7,5
9,75
12
15
18,8
24
30
37,5
47,3

10

60
0,41
0,82
1,32
1,65
3,29
4,94
8,23
10,7
13,2
16,5
20,6
26,3
32,9
41,2
51,9

10

50
0,44
0,88
1,42
1,77
3,55
5,33
8,89
11,5
14,2
17,7
22,2
28,4
35,5
44,4
56

Max. operating I t (A s)

2
2

10

40
0,47
0,94
1,51
1,88
3,77
5,66
9,44
12,2
15,1
18,8
23,6
30,2
37,7
47,2
59,4

I t/As

Ip/A

10

Ambient temperature T/OC


0
10
20
30
0,56 0,54 0,52
0,5
1,12 1,09 1,05
1
1,79 1,74 1,68
1,6
2,24 2,18
2,1
2
4,49 4,36 4,20
4
6,73 6,54 6,31
6
11,2 10,9 10,5
10
14,5 14,1 13,6
13
17,9 17,4 16,8
16
22,4 21,8
21
21
28
27,2 26,3
25
35,9 34,9 33,6
32
44,9 43,6
42
40
56,1 54,5 52,6
50
70,7 68,7 66,2
63

10

-10
0,57
1,15
1,84
2,30
4,61
6,91
11,5
14,9
18,4
23
28,8
36,9
46,1
57,6
72,6

10

-20
0,59
1,18
1,89
2,36
4,72
7,09
11,8
15,4
18,9
23,6
2,5
37,8
47,8
59,1
74,4

I t/As

Max. operating I t (A s)

-30
0,6
1,2
1,92
2,4
4,8
7,2
12
15,6
19,2
24
30
38,4
48
60
75,6

10

Max. operating I t (A s)

PRODUCT LINE
E11

Miniature circuit breakers

10

K6

10 3

1.5

2.5

Prospective current I p (A)

9 10 4

PRODUCT LINE
E11

Miniature circuit breakers

Miniature circuit breaker ETIMAT11


Rated short-circuit capacity

10 kA

1-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20
25
32
40
50
63

Un
[V]
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400

1-pole + N
ln
[A]
0,5
1
2
4
6
10
13
16
20
25
32
40
50
63

Un
[V]
230
230
230
230
230
230
230
230
230
230
230
230
230
230

2-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400
400
400
400
400

Rated current

0,5 - 63 A

Tripping characteristic

B, C, D, K

code No. B

code No. C

code No. D

code No. K

700600102
701000105
701300104
701600103
702000106
702500101
703200103
704000108
705000109
706300109

700501100
700101108
700201101
700401107
700601103
701001106
701301105
701601104
702001107
702501102
703201104
704001109
705001100
706301100

700502101
700102109
700202102
700402108
700602104
701002107
701302106
701602105
702002108
702502103
703202105

700503102
700103100
700203103
700403109
700603105
701003108
701303107
701603106
702003109
702503104
703203106

code No. B

code No. C

code No. D

code No. K

700610109
701010102
701310101
701610100
702010103
702510108
703210100
704010105
705010106
706310106

700511107
700111105
700211108
700411104
700611100
701011103
701311102
701611101
702011104
702511109
703211101
704011106
705011107
706311107

700512108
700112106
700212109
700412105
700612101
701012104
701312103
701612102
702012105
702512100
703212102

700513109
700113107
700213100
700413106
700613102
701013105
701313104
701613103
702013106
702513101
703213103

code No. B

code No. C

code No. D

code No. K

700620106
701020109
701320108
701620107
702020100
702520105
703220107
704020102
705020103
706320103

700521104
700121102
700221105
700421101
700621107
701021100
701321109
701621108
702021101
702521106
703221108
704021103
705021104
706321104

700522105
700122103
700222106
700422102
700622108
701022101
701322100
701622109
702022102
702522107
703222109

700523106
700123104
700223107
700423103
700623109
701023102
701323101
701623100
702023103
702523108
703223100

weight
[g]
124
124
124
124
124
121
121
121
121
121
121
130
130
130

packaging
[pcs]
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60

weight
[g]
249
249
249
249
249
245
245
245
245
245
245
261
261
261

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

weight
[g]
249
249
249
249
249
245
245
245
245
245
245
261
261
261

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

PRODUCT LINE
E11

Miniature circuit breakers

3-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400
400
400
400
400

3-pole + N
ln
[A]
0,5
1
2
4
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400
400
400
400
400

code No. B

code No. C

code No. D

code No. K

700630103
701030106
701330105
701630104
702030107
702530102
703230104
704030109
705030100
706330100

700531101
700131109
700231102
700431108
700631104
701031107
701331106
701631105
702031108
702531103
703231105
704031100
705031101
706331101

700532102
700132100
700232103
700432109
700632105
701032108
701332107
701632106
702032109
702532104
703232106

700533103
700133101
700233104
700433100
700633106
701033109
701333108
701633107
702033100
702533105
703233107

code No. B

code No. C

code No. D

code No. K

700640100
701040103
701340102
701640101
702040104
702540109
703240101
704040106
705040107
706340107

700541108
700141106
700241109
700441105
700641101
701041104
701341103
701641102
702041105
702541100
703241102
704041107
705041108
706341108

700542109
700142107
700242100
700442106
700642102
701042105
701342104
701642103
702042106
702542101
703242103

700543100
700143108
700243101
700443107
700643103
701043106
701343105
701643104
702043107
702543102
703243104

code No. B

code No. C

code No. D

code No. K

710600109
711000102
711300101
711600100
712000103

710501107
710101105
710201108
710401104
710601100
711001103
711301102
711601101
712001104

710502108
710102106
710202109
710402105
710602101
711002104
711302103
711602102
712002105

710503109
710103107
710203100
710403106
710603102
711003105
711303104
711603103
712003106

weight
[g]
377
377
377
377
377
367
367
367
367
367
367
393
393
393

packaging
[pcs]
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20

weight
[g]
500
500
500
500
500
488
488
488
488
488
488
524
524
524

packaging
[pcs]
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15

weight
[g]
124
124
124
124
124
121
121
121
121

packaging
[pcs]
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60

Miniature circuit breaker ETIMAT 11-QC


Rated short-circuit capacity

10 kA

Rated current

0,5 - 20 A

Tripping characteristic

B, C, D, K

1-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20

Un
[V]
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400

1-pole + N
ln
[A]
0,5
1
2
4
6
10
13
16
20

Un
[V]
230
230
230
230
230
230
230
230
230

2-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20

Un
[V]
400
400
400
400
400
400
400
400
400

3-pole
ln
[A]
0,5
1
2
4
6
10
13
16
20

Un
[V]
400
400
400
400
400
400
400
400
400

3-pole + N
ln
[A]
0,5
1
2
4
6
10
13
16
20

Un
[V]
400
400
400
400
400
400
400
400
400

code No. B

code No. C

code No. D

code No. K

710610106
711010109
711310108
711610107
712010100

710511104
710111102
710211105
710411101
710611107
711011100
711311109
711611108
712011101

710512105
710112103
710212106
710412102
710612108
711012101
711312100
711612109
712012102

710513106
710113104
710213107
710413103
710613109
711013102
711313101
711613100
712013103

code No. B

code No. C

code No. D

code No. K

710620103
711020106
711320105
711620104
712020107

710521101
710121109
710221102
710421108
710621104
711021107
711321106
711621105
712021108

710522102
710122100
710222103
710422109
710622105
711022108
711322107
711622106
712022109

710523103
710123101
710223104
710423100
710623106
711023109
711323108
711623107
712023100

code No. B

code No. C

code No. D

code No. K

710630100
711030103
711330102
711630101
712030104

710531108
710131106
710231109
710431105
710631101
711031104
711331103
711631102
712031105

710532109
710132107
710232100
710432106
710632102
711032105
711332104
711632103
712032106

710533100
710133108
710233101
710433107
710633103
711033106
711333105
711633104
712033107

code No. B

code No. C

code No. D

code No. K

710640107
711040100
711340109
711640108
712040101

710541105
710141103
710241106
710441102
710641108
711041101
711341100
711641109
712041102

710542106
710142104
710242107
710442103
710642109
711042102
711342101
711642100
712042103

710543107
710143105
710243108
710443104
710643100
711043103
711343102
711643101
712043104

weight
[g]
249
249
249
249
249
245
245
245
245

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

weight
[g]
249
249
249
249
249
245
245
245
245

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

weight
[g]
377
377
377
377
377
367
367
367
367

packaging
[pcs]
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20

weight
[g]
500
500
50
500
500
488
488
488
488

packaging
[pcs]
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15

PRODUCT LINE
E11

Miniature circuit breakers

PRODUCT LINE
E11

Miniature circuit breakers

Miniature circuit breaker ETIMAT RC (remote control)


Rated short-circuit capacity

10 kA

Rated current

6 - 63 A

Tripping characteristics

B, C

1-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63


10

Un
[V]
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400

1-pole + N
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
230
230
230
230
230
230
230
230
230
230

2-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400

3-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400

code No. B

code No. C

630600100
631000103
631300102
631600101
632000104
632500109
633200101
634000106
635000107
636300107

630601101
631001104
631301103
631601102
632001105
632501100
633201102
634001107
635001108
636301108

code No. B

code No. C

630610107
631010100
631310109
631610108
632010101
632510106
633210108
634010102
635010103
636310103

630611108
631011101
631311100
631611109
632011102
632511107
633211109
634011103
635011104
636311104

code No. B

code No. C

630620104
631020107
631320106
631620105
632020108
632520103
633220105
634020100
635020101
636320101

630621105
631021108
631321107
631621106
632021109
632521104
633221106
634021101
635021102
636321102

code No. B

code No. C

630630101
631030104
631330103
631630102
632030105
632530100
633230102
634030107
635030108
636330108

630631102
631031105
631331104
631631103
632031106
632531101
633231103
634031108
635031109
636331109

weight
[g]
124
121
121
121
121
121
121
130
130
130

packaging
[pcs]
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60

weight
[g]
249
245
245
245
245
245
245
261
261
261

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

weight
[g]
249
245
245
245
245
245
245
261
261
261

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

weight
[g]
377
367
367
367
367
367
367
393
393
393

packaging
[pcs]
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20

3-pole + N
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
400
400
400
400
400
400
400
400
400
400

code No. B

code No. C

630640108
631040101
631340100
631640109
632040102
632540107
633240109
634040104
635040105
636340105

700641109
701041102
701341101
701641100
702041103
702541108
703241100
704041105
705041106
706341106

weight
[g]
500
488
488
488
488
488
488
524
524
524

PRODUCT LINE
E11

Miniature circuit breakers

packaging
[pcs]
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15

Miniature circuit breaker ETIMAT11-DC


Rated short-circuit capacity

6 kA

Rated current

6 - 63 A

1-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
220
220
220
220
220
220
220
220
220
220

2-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

Un
[V]
440
440
440
440
440
440
440
440
440
440

Tripping characteristic

B, C

code No. B

code No. C

690600102
691000105
691300104
691600103
692000106
692500101
693200103
694000108
695000109
696300109

690601106
691001109
691301108
691601107
692001100
692501105
693201107
694001102
695001103
696301103

code No. B

code No. C

690620106
691020109
691320108
691620107
692020100
692520105
693220107
694020102
695020103
696320103

690621107
691021100
691321109
691621108
692021101
692521106
693221108
694021103
695021104
696321104

weight
[g]
124
245
245
245
245
245
245
261
261
261

packaging
[pcs]
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60

weight
[g]
249
245
245
245
245
245
245
261
261
261

packaging
[pcs]
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30
6/30

Accessories for ETIMAT11, ETIMAT11-QC and ETIMAT11-DC


PS/SS E11 is an auxiliary switch used for remote signalling of the MCB to which it is fixed.
PS/SS E11 may also be fixed later of the state. Clamps are safe to touch. External dimensions comply
with MCB, built-in width is 0,5 module (9 mm). During fitting, the MCB must be switched off.

Auxiliary switch PS/SS E11


type
code No.
PS/SS E11

768900101

contacts
1xNC, 1xNC/NO

weight
[g]
40

packaging
[pcs]
1/10

11

PRODUCT LINE
E11

Miniature circuit breakers

DA ETIMAT11 shunt trip release is fixed to the right side of the miniature circuit breaker ETIMAT11 for
remote release of the MCB. Dimensions correspond to those of MCB ETIMAT11.

Shunt trip release DA ETIMAT 11


type
code No.
DA ETIMAT11 12-60V AC/DC
DA ETIMAT11 110-250V AC

770610108
772510107

weight
[g]
110
110

packaging
[pcs]
1/54
1/54

weight
[g]
231
231
231

packaging
[pcs]
2/72
2/72
2/72

weight
[g]
466
466
466

packaging
[pcs]
1/36
1/36
1/36

weight
[g]
696
696
696

packaging
[pcs]
1/18
1/18
1/18

weight
[g]
860
860
860

packaging
[pcs]
1/18
1/18
1/18

Miniature circuit breaker ETIMAT11 80 -125A


Rated short-circuit capacity

15, 20 kA

Rated current

80 - 125 A

Tripping characteristics

C, D

1-pole
ln
[A]
80
100
125

2-pole
ln
[A]
80
100
125

3-pole
ln
[A]
80
100
125

3-pole + N
ln
[A]
80
100
125


12

code No. C

code No. D

002131731
002131732
002131733

002151731
002151732

code No. C

code No. D

002133731
002133732
002133733

002153731
002153732

code No. C

code No. D

002135731
002135732
002135733

002155731
002155732

code No. C

code No. D

002136731
002136732
002136733

002156731
002156732

PRODUCT LINE
E11

Miniature circuit breakers

Accessories for ETIMAT11 80 - 125A

Shunt trip release DA ETIMAT 80/125 110 - 415V


code No. B
weight
packaging
[g]
[pcs]
002159321
173
1/54

Auxiliary switch PSM 80/125


code No. B
weight
[g]
002159121
62

packaging
[pcs]
1/12

Current limiter OSP-11


Rated short-circuit capacity

10 kA

1-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

3-pole
ln
[A]
6
10
13
16
20
25
32
40
50
63

Rated current

6 - 63 A

code No.
700603992
701003995
701303994
701603993
702003996
702503991
703203993
704003998
705003999
706303999

code No.
700633993
701033996
701333995
701633994
702033997
702533992
703233994
704033999
705033990
706333990

Tripping characteristics
Test current
Tripping time
t > 3600 s
1,1 x In
2 < t < 900 s
1,4 x In
0,5 < t < 60 s
2,5 x In
t > 0,1 s
10 x In
t < 0,1 s
20 x In

Rated voltage

230/400 V

weight
[g]
124
121
121
121
121
121
121
130
130
130

packaging
[pcs]
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60
12/60

weight
[g]
377
367
367
367
367
367
367
393
393
393

packaging
[pcs]
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20
4/20

Application
< Limiting the consumption of
electric power based on current
overload
< Protection against short circuit.
Dimensions
< A single pole device (width 1
module) dimensions fit circuit
breaker ETIMAT 11
< Three-pole device: width of 3
modules
Built-in
< Domestic distribution boards
(built-in and surface-mounted), it
is possible to seal the connecting
terminals with special sealing
peace.
< Surface-mounted distribution
board NE 2 (distribution board
width: 2 moduls) for a single pole
device
< Surface-mounted distribution
board NE 4 (distribution board
width: 4 moduls) for three pole
device
< Sealing available for both NE 2
and NE 4.

Result
No tripping
Tripping
Tripping
No tripping
Tripping
13

PRODUCT LINE
E11

Residual current circuit breakers

Residual current circuit breakers


Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for
prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation
and for protection against direct contacts of parts under voltage in case of In30mA. Residual current circuit breakers
can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective
conductor are separated (VDE 0100 Part 410).
Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current
(AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).

type
A

EFI 2
EFI 4
type type type type type type type type
AC
G
UT
A
AC
S
G
UT

For alternating residual current


For alternating and pulsating direct
residual current
Short-circuit capacity with back-up
fuse
lower temperature limit of
application -25C
VDE 0664, part 1
(up to 80 A)
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)
UT

Unwanted tripping

Note: Tripping time according to standard IEC 61008

Residual current circuit breaker EFI-2


Rated residual current

0,03 - 0,5 A

Rated current

16 - 80 A

type

A, AC, G

EFI-2 type A, EFI-2 type AC


number
ln
ln
[A]
[A]
of poles
16
0,03
2
25
0,03
2
40
0,03
2
63
0,03
2
80
0,03
2
16
0,1
2
25
0,1
2
40
0,1
2
63
0,1
2
80
0,1
2
16
0,3
2
25
0,3
2
40
0,3
2
63
0,3
2
80
0,3
2
16
0,5
2
25
0,5
2
40
0,5
2
63
0,5
2
80
0,5
2


14

code No. A

code No. AC

002062521
002062522
002062523
002062524
002062525
002063521
002063522
002063523
002063524
002063525
002064521
002064522
002064523
002064524
002064525
002065521
002065522
002065523
002065524
002065525

002062121
002062122
002062123
002062124
002062125
002063121
002063122
002063123
002063124
002063125
002064121
002064122
002064123
002064124
002064125
002065121
002065122
002065123
002065124
002065125

weight
[g]
229
229
229
244
244
223
223
223
227
230
223
223
223
227
230
223
223
223
227
230

packaging
[pcs]
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54

PRODUCT LINE
E11

Residual current circuit breakers

Residual current circuit breaker EFI-4


Rated residual current

0,03 - 0,5 A

Rated current

16 - 80 A

type

A, AC

EFI-4 type A, EFI-4 type AC


number
code No. A
ln
ln
[A]
[A]
of poles
16
0,03
4
002062541
25
0,03
4
002062542
40
0,03
4
002062543
63
0,03
4
002062544
80
0,03
4
002062545
16
0,1
4
002063541
25
0,1
4
002063542
40
0,1
4
002063543
63
0,1
4
002063544
80
0,1
4
002063545
16
0,3
4
002064541
25
0,3
4
002064542
40
0,3
4
002064543
63
0,3
4
002064544
80
0,3
4
002064545
16
0,5
4
002065541
25
0,5
4
002065542
40
0,5
4
002065543
63
0,5
4
002065544
80
0,5
4
002065545
* type with N-pole on the left side is also available.

code No. AC
002062141
002062142
002062143
002062144
002062145
002063141
002063142
002063143
002063144
002063145
002064141
002064142
002064143
002064144
002064145
002065141
002065142
002065143
002065144
002065145

weight
[g]
393
393
393
400
407
393
393
393
400
407
364
364
364
372
372
364
364
364
372
372

packaging
[pcs]
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27

Accessories for residual current circuit breakers EFI (16 - 80 A)


The PS EFI is fixed to EFI series switches. The width of the device is 9 mm, other dimensions are in compliance with EFI
switches. The auxiliary switch PS EFI is used for the remote signalling of the state of contacts condition (close/open) of
EFI switches. During fitting, the EFI must be switched off.

Auxiliary Switch PS EFI


type
contact

code No.

PS EFI - MD
b-contact/a-contact
PS EFI - 2M
2 x b-contact
PS EFI - 2D
2 x a-contact
a - contact = make contact (NO)
b - contact = break contact (NC)

002069001
002069002
002069003

Sealing piece EFI-2


code No.
weight
[g]
002069011
2

packaging
[pcs]
2

Sealing piece EFI-4


code No.
weight
[g]
002069012
3

packaging
[pcs]
2

weight
[g]
50
50
50

packaging
[pcs]
1/12
1/12
1/12

15

PRODUCT LINE
E11

Residual current circuit breakers

Residual current circuit breaker EFI-2 100


Rated residual current

0,03 - 0,3 A

Rated current

100 A

type

A, AC

EFI-2 100
ln
[A]
100
100
100

type A, EFI-2 100 type AC


number
code No. A
ln
[A]
of poles
0,03
2
002062530
0,1
2
002062532
0,3
2
002062534

code No. AC
002062531
002062533
002062535

weight
[g]
400
400
400

packaging
[pcs]
1/27
1/27
1/27

weight
[g]
320
320
320

packaging
[pcs]
1/27
1/27
1/27

Residual current circuit breaker EFI-4 100


Rated residual current

0,03 - 0,3 A

Rated current

100 A

type

A, AC

EFI-4 100
ln
[A]
100
100
100

type A, EFI-4 100 type AC


number
code No. A
ln
[A]
of poles
0,03
4
002062150
0,1
4
002062152
0,3
4
002062154

code No. AC
002062151
002062153
002062155

Residual current circuit breaker EFI-2 UT


Rated residual current

0,03 A

Rated current

25 A

type

EFI-2 UT type A
ln
ln
[A]
[A]
25
0,03

number
of poles
2

code No. A
852528418

weight
[g]
260

packaging
[pcs]
1/10

weight
[g]
453
453
470
470
470
470
470
470
470

packaging
[pcs]
1/10
1/10
1/10
1/10
1/10
1/10
1/10
1/10
1/10

Residual current circuit breaker EFI-4 UT


Rated residual current

0,03 - 0,5 A

Rated current

25 -63 A

type

EFI-4 UT type A
ln
ln
[A]
[A]
25
0,03
40
0,03
63
0,03
40
0,1
63
0,1
40
0,3
63
0,3
40
0,5
63
0,5

16

number
of poles
4
4
4
4
4
4
4
4
4

code No. A
852548411
854048418
856348419
854041411
856341412
854043413
856343414
854045415
856345416

PRODUCT LINE
E11

Residual current circuit breakers

Residual current circuit breaker EFI-4 S


Rated residual current

0,3 A

Rated current

40 - 63 A

type

A, AC

EFI-4 S type A, EFI-4 S type AC


number
code No. A
ln
ln
[A]
[A]
of poles
40
0,3
4
859443410
63
0,3
4
859643416

code No. AC

weight
[g]
400
400

002064243
002064244

packaging
[pcs]
1/27
1/27

Residual current circuit breaker EFI-4 KV/G


Rated residual current

0,03 A

Rated current

40 A

EFI-4 KV/G type A


number
ln
ln
[A]
[A]
of poles
40
0,03
4

type

code No. A
854088416

weight
[g]
400

packaging
[pcs]
1/27

Accessories for residual current circuit breakers EFI UT, EFI S, EFI KV/G
PS/SS is an auxiliary switch used for remote signalling of the MCB to which it is fixed.
PS/SS may also be fixed later of the state. Clamps are safe to touch. External dimensions comply with
EFI, built-in width is 0,5 module (9 mm). During fitting, the EFI must be switched off.

Auxiliary switch PS/SS


type

code No.

contacts

PS/SS

769900102

1xNC, 1xNC/NO

weight
[g]
40

packaging
[pcs]
1/10

17

PRODUCT LINE
E11

Residual current circuit breakers with integral overcurrent protection

Residual current circuit breakers with integral


overcurrent protection
Residual current circuit breaker with integral overcurrent protection KZS-2M
Rated short-circuit capacity

10 kA

Rated current

6 - 40 A

Tripping characteristic

B, C

Rated residual current

0,01 - 0,03 - 0,3 A

Description: KZS (KZS-2M, KZS-3M, KZS-4M 3p, KZS-4M 3p+N and KZS-2M UT) is a residual current
circuit breaker combining the features of a miniature circuit-breaker and a residual current circuit
breaker and is functionally independent on line voltage. Used primarily in circuits with an increased
requirements regarding touch voltage such circuits of portable appliances, in kindergartens, schools
and hospitals etc.


18

KZS-2M
ln
[A]
6
10
13
16
20
25
32
40

In = 30 mA
type A
code No. B
code No. C
002173201
002173221
002173202
002173222
002173203
002173223
002173204
002173224
002173205
002173225
002173206
002173226
002173207
002173227
002173208
002173228

type AC
code No. B
code No. C
002173101
002173121
002173102
002173122
002173103
002173123
002173104
002173124
002173105
002173125
002173106
002173126
002173107
002173127
002173108
002173128

KZS-2M
ln
[A]
6
10
13
16
20
25
32
40

In = 300 mA
type AC
code No. B
code No. C
002173301
002173321
002173302
002173322
002173303
002173323
002173304
002173324
002173305
002173325
002173306
002173326
002173307
002173327
002173308
002173328

packaging
[pcs]
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54

KZS-2M
ln
[A]
6
10
13
16

In = 10 mA
type A
code No. B
code No. C
002173211
002173231
002173212
002173232
002173213
002173233
002173214
002173234

packaging
[pcs]
1/54
1/54
1/54
1/54

packaging
[pcs]
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54

PRODUCT LINE
E11

Residual current circuit breakers with integral overcurrent protection

Residual current circuit breaker with integral overcurrent protection KZS-3M


Rated short-circuit capacity

10 kA

KZS-3M
ln
[A]
6
10
13
16
20
25

Rated current

6 - 25 A

Tripping characteristic

B, C

In = 30 mA
type A
code No. B
code No. C
002173801
002173821
002173802
002173822
002173803
002173823
002173804
002173824
002173805
002173825
002173806
002173826

Rated residual current

0,03 A

packaging
[pcs]
1/36
1/36
1/36
1/36
1/36
1/36

Residual current circuit breaker with integral overcurrent protection KZS-4M 3p


Rated short-circuit capacity

10 kA

Rated current

6 - 32 A

Tripping characteristic

B, C

Rated residual current

0,03 A

NEW!

KZS-4M 3p In = 30 mA
type A
ln
[A]
code No. B
code No. C
6
002174701
002174721
10
002174702
002174722
13
002174703
002174723
16
002174704
002174724
20
002174705
002174725
25
002174706
002174726
32
002174707
002174727

type AC
code No. B
code No. C
002174801
002174821
002174802
002174822
002174803
002174823
002174804
002174824
002174805
002174825
002174806
002174826
002174807
002174827

weight
[g]
478
478
478
478
478
478
478

packaging
[pcs]
1/27
1/27
1/27
1/27
1/27
1/27
1/27

Residual current circuit breaker with integral overcurrent protection KZS-4M 3p+N
Rated short-circuit capacity

10 kA

Rated current

6 - 32 A

Tripping characteristic

B, C

Rated residual current

0,03 A

NEW!

KZS-4M 3p+N In = 30 mA
type A
ln
[A]
code No. B
code No. C
6
002174901
002174921
10
002174902
002174922
13
002174903
002174923
16
002174904
002174924
20
002174905
002174925
25
002174906
002174926
32
002174907
002174927

type AC
code No. B
code No. C
002174001
002174021
002174002
002174022
002174003
002174023
002174004
002174024
002174005
002174025
002174006
002174026
002174007
002174027

weight
[g]
478
478
478
478
478
478
478

packaging
[pcs]
1/27
1/27
1/27
1/27
1/27
1/27
1/27

Residual current circuit breaker with integral overcurrent protection KZS-2M UT


Rated short-circuit capacity

10 kA

Rated current

16 A

KZS-2M UT In = 30 mA
type A
ln
[A]
code No. B
code No. C
16
741615323
741616324

Tripping characteristic

B, C

weight
[g]
290

Rated residual current

0,03 A

packaging
[pcs]
1/10

19

PRODUCT LINE
E11

Build-in switch

Accessories for residual current circuit breaker with integral overcurrent protection KZS-2M UT
PS/SS is an auxiliary switch used for remote signalling of the MCB to which it is fixed.
PS/SS may also be fixed later of the state. Clamps are safe to touch. External dimensions comply with
KZS-2M UT, built-in width is 0,5 module (9 mm). During fitting, the KZS-2M UT must be switched off.

Auxiliary switch PS/SS


type

code No.

contacts

PS/SS

769900102

1xNC, 1xNC/NO

weight
[g]
40

packaging
[pcs]
1/10

Build-in switch
Build-in switch SV
Rated current

100 A

Utilization category

AC-22B

Application
Build-in switch is used as a main switch in distribution boxes in houses or as a switch for individual electric circuits.
With a build-in switch we can completely replace the cam switch. Build-in switch can be sealed either in ON or OFF
position.
Advantages
Build-in switch has a more robust and simple construction and therefore a more reliable operation. It also shows the
status of the contacts. With an additional label the circuit in which the switch is built in can be marked. Switches with
In 63A have a double switching OFF.

1-pole
type

SV 1100

2-pole
type

SV 2100

3-pole
type

SV 3100

20

In

code No.

Un

[A]
100

002423116

[V]
230/400

In

code No.

Un

[A]
100

002423216

[V]
400

In

code No.

Un

[A]
100

002423316

[V]
400

utilization
category
AC-22B

utilization
category
AC-22B

utilization
category
AC-22B

weight

packaging

[g]
90

[pcs]
12/108

weight

packaging

[g]
180

[pcs]
6/54

weight

packaging

[g]
270

[pcs]
4/36

4-pole
type

SV 4100

In

code No.

Un

[A]
100

002423416

[V]
400

utilization
category
AC-22B

weight

packaging

[g]
360

[pcs]
3/27

PRODUCT LINE
E11

Build-in switch

21

ETI Elektroelement d.d.


Obrezija 5, SI - 1411 Izlake
Slovenia
Phone: + 386 03 56 57 570
Fax: + 386 03 56 74 077
eti@eti.si