GOVERNMENT OF INDIA DEPARTMENT OF ATOMIC ENERGY DIRECTORATE OF CONSTRUCTION, SERVICES AND ESTATE MANAGEMENT CHIEF ENGINEER (ELECTRICAL) 4th

floor, Vikram Sarabhai Bhavan, Anushaktinagar, Mumbai 400 094 Telephone: (022) 25487416/7486/7411/7420/7415 Fax: (022) 2556 5362 E-TENDER FINANCIAL BID NIT No.: DCSE/CE(E)/ 356 flats /Ext/11/09-2013 dt. 24/09/2013 Name of work : Providing External Electrical works for 356 flats at Anushaktinagar, Mumbai-94.

NAME OF THE CONTRACTOR

Schedule of Quantities
Sl. Description of Item No. 1.0 L.T. Power Cable: Supply, installation, testing & commissioning of 1.1 KV grade stranded aluminium conductor circular/ sector shape core with PVC/XLPE insulation, PVC extruded (inner) sheathed, G.I flat strip/wire armoured, PVC outer sheathed with antirodent & anti termite treatement FRLS grade PVC sheath type ST-2 cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/column /slab /false ceiling or in existing hume pipe/trench/ shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws /grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/ angles and saddles or in ground at a - depth of 900 mm below ground level/in all types of soil/concrete road cutting /foot path cutting including excavation (except Murram/hard rock), sand bedding, laying of baked bricks on side & top-, temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500 mtrs and making good to the original finish etc providing brass cable number tag as per enclosed detailed technical specifications standard drawing no. CSG-EM-STD-13-R2 & as per instructions of the E-I-C of the following sizes. Note: 1) LT Cable shall meet all the technical specifications as per Section -6. 2) In case short lengths FRLS cable is not available coating of Fire retardant Intumescent paint may be done on normal PVC cable for one meter from end joint. 3) More than one cable is taken on M.S angle iron cable supports made with 40 x 40 X 5 mm angle section, duly painted shall be used. 4) The length given against quantity of cable shall be treated as route length. 5) Sealing of hume pipes with wooden bushes after cable laying shall be included in the scope of work. 6) Excavation inmuram/ hard rock to be measured under item no. 8. 1.1 3.5 C x 95 sq.mm Aluminium PVC/XLPE armoured cable 1.1.1 In hume pipe/GI pipe/ cable trench/on wall/ slab/ beam/ coloumn /M.S. support etc. 200 mtr 0 Qty Unit Rate (`) Amount (`)

1.1.2 In ground 1.2 3.5 C x 150 sq.mm Aluminium PVC/XLPE armoured cable

50

mtr

Page No. 1 of 9

Sl. No.

Description of Item

Qty

Unit

Rate (`) Amount (`)

1.2.1 In hume pipe/GI pipe/ cable trench/on wall/ slab/ beam/ coloumn /M.S. support etc.

120

mtr

1.2.2 In ground 1.3 3.5 C x 240 sq.mm Aluminium PVC/XLPE armoured cable 1.3.1 In hume pipe/GI pipe/ cable trench/on wall/ slab/ beam/ coloumn /M.S. support etc.

230

mtr

490

mtr

1.3.2 In ground 1.4 3.5 C x 300 sq.mm Aluminium PVC/XLPE armoured cable 1.4.1 In hume pipe/GI pipe/ cable trench/on wall/ slab/ beam/ coloumn /M.S. support etc.

1450

mtr

80

mtr

1.4.2 In ground 1.5 End Joints: End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of Engineer-in-charge. 1.5.1 3.5 C x 95 sq.mm Aluminium PVC/XLPE armoured cable 1.5.2 3.5 C x 150 sq.mm Aluminium PVC/XLPE armoured cable 1.5.3 3.5 C x 240 sq.mm Aluminium PVC/XLPE armoured cable 1.5.4 3.5 C x 300 sq.mm Aluminium PVC/XLPE armoured cable 2.0 LT PANEL: Design, manufacture, testing at works, supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-52 protection with hinged and lockabale doors. Switchboards fabricated from CRCA sheets 2 mm thick for load bearing members & 1.6 mm thick for non load bearing members (minimum) as per manufactures standards, including interconnections, tinned copper strip /Wire crimping lugs, bonding to earth and painting suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and to withstand a fault level of 50 KA symmetrical at 415 V complete as per specifications, as required. LT Panel shall be comprising of various sections . All switchboards shall have provision for entry of cables from the top/bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves. SMC/ DMC shrouds and busbar supports shall be used.

220

mtr

30 10 36 4

nos nos nos nos

0 0 0 0

Page No. 2 of 9

Sl. No.

Description of Item Note: 1) All G.A. & fabrication drawings shall be got approved from the E.I.C. Panel shall be powdercoated with approved shade RAL-7032. Necessary touch up shall be done at site, incase if required. The scope includes all tests as specified in department's specification, relevant I.S. and as required by E.I.C, shall have to be performed at factory & at installation site and shall be included in the quoted rate. 2) The equipment shall be designed to ensure complete safety during operation inspection, connection of cables etc. 3) Control wires shall be of 1.1 KV 4 / 2.5 sq.mm FRLS copper wires and neatly bunched separately and adequately supported so as to prevent sagging and strain on termination. 4) A minimum of 10% spare terminals shall be provided on each terminal block. 5) All non current carrying metallic parts of the equipment shall be earthed with copper flexible wire / strip of adequate size. 6) All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. 7) The size of the earth bus chosen shall be to withstand full fault current of 50 KA 8) Earth bus bar shall be supported at suitable intervals. 9) All the current transformers shall be resin cast type class-I only. 10) Scope includes cable end boxes, reverse entry boxes as per site conditions and extension of bus bars as required for terminating the number of cables as per schematic diagram. 11) G.A. & detailed fabrication drawing and short circuit forces and temp rise calculation for busbars including the panel fabricator shall be submitted for dept. approval, before fabrication. 12) Bimetallic washers to be used for all aluminium to copper joints wherever required & it shall be of approved make & quality where ever required. 13) Indication lamp shall be cluster type LED heavy duty. 14) All Outgoing feeders shall have 'ON', 'OFF'indication lamp. 15) All neutral shall be isolatable type. 16) The scope includes the Supply and installation of M.S. Channel (ISMC 100) required for installation of panel on cable trench. 17) Scope includes the cutting of M.S.chequered plate trench covers to require size after installation of Panel. 18) The contactors shall have interlock. 19) Cubicle illumination lamp & space heater in the cable alley should be provided with neccesary switch/ MCB. 20) Panel shall meet all as per the technical specification. 21) All interconnections for incoming & outgoing shall be with tinned copper bus bar for 100A & above 100A capacity outgoing & single core stranded copper conductor pvc insulated wire below 100A capacity outgoing. 22) All MCCB's shall be of 50 KA breaking capacity with O/L, S/C thermal magnetic release. 23) Vertical bus rating shall be based on outgoing feeders. 24) The switchboard shall have provision for entry of busduct / cables from top /bottom as required as per site condition. 25) Neutral link shall be tinned copper.

Qty

Unit

Rate (`) Amount (`)

Page No. 3 of 9

Sl. Description of Item No. 2.1 L T Panel at Type -E building (electrical room). I/C comprising of the following: i) 400 A, TP MCCB with neutral bus bar & link with all accessories - 1No. ii) R,Y,B LED Indication lamps with HRC fuses- 1 set. iii) 0-500 V 96 x 96 mm Voltmeter with selector switch & HRC fuses - 1 set. iv) Current transformers 400/5Amps, 10VA, Class-1.0 ( for metering) - 3 Nos. v) 0-400 A 96 x 96 mm Ammeter with selector switch. - 1 No. Busbars: 400 Amp TPN tinned copper busbar having maximum current density of 1.24 Amp/sq. mm to with stand symmetrical fault level of 50 KA at 415 V. The neutral busbar shall have 100 % capacity. R,Y,B LED Indication lamps with HRC fuses- 1 set for busbar Outgoing feeders : a) 400A, TP MCCB with neutral bus bar & link with all accessories - 1No.. b) 250A, TP, MCCB with neutral bus bar & link with all accessories- 3Nos. c) 125A, TP, MCCB with neutral bus bar & link with all accessories- 1No. d) 100A, TP, MCCB with neutral bus bar & link with all accessories- 1No. e) 63A, TP, MCCB with neutral bus bar & link with all accessories- 2No.

Qty 1

Unit Set

Rate (`) Amount (`) 0

2.2 L T Panel at Type -D ( D1- buildings electrical room- North & D2- buildings electrical room- East). I/C comprising of the following: i) 400 A, TP MCCB with neutral bus bar & link with all accessories - 1No.. ii) R,Y,B LED Indication lamps with HRC fuses- 1 set. iii) 0-500 V 96 x 96 mm Voltmeter with selector switch & HRC fuses - 1 set. iv) Current transformers 400/5Amps, 10VA, Class-1.0 ( for metering) - 3 Nos. v) 0-400 A 96 x 96 mm Ammeter with selector switch. - 1 No. Busbars: 400 Amp TPN tinned copper busbar having maximum current density of 1.24 Amp/sq. mm to with stand symmetrical fault level of 50 KA at 415 V. The neutral busbar shall have 100 % capacity. R,Y,B LED Indication lamps with HRC fuses- 1 set for busbar Outgoing feeders : a) 400A, TP, MCCB with neutral bus bar & link with all accessories- 1No. b) 250A, TP, MCCB with neutral bus bar & link with all accessories- 3Nos. c) 200A, TP, MCCB with neutral bus bar & link with all accessories- 1 No. d) 100A, TP, MCCB with neutral bus bar & link with all accessories- 1No. e) 63A, TP, MCCB with neutral bus bar & link with all accessories- 2Nos.

sets

2.3 L T Panel at Type -D ( D1- buildings electrical room- South & D2- buildings electrical room- West). I/C comprising of the following: i) 400 A, TP MCCB with neutral bus bar & link with all accessories - 1No.. ii) R,Y,B LED Indication lamps with HRC fuses- 1 set. iii) 0-500 V 96 x 96 mm Voltmeter with selector switch & HRC fuses - 1 set. iv) Current transformers 400/5Amps, 10VA, Class-1.0 ( for metering) - 3 Nos. v) 0-400 A 96 x 96 mm Ammeter with selector switch. - 1 No.

sets

Page No. 4 of 9

Sl. No.

Description of Item Busbars: 400 Amp TPN tinned copper busbar having maximum current density of 1.24 Amp/sq. mm to with stand symmetrical fault level of 50 KA at 415 V. The neutral busbar shall have 100 % capacity. R,Y,B LED Indication lamps with HRC fuses- 1 set for busbar Outgoing feeders : a) 400A, 4P, Isolator with all accessories- 1 No. b) 250A, TP, MCCB with neutral bus bar & link with all accessories- 3Nos. c) 125A, TP, MCCB with neutral bus bar & link with all accessories- 1 No. d) 100A, TP, MCCB with neutral bus bar & link with all accessories- 1No. e) 63A, TP, MCCB with neutral bus bar & link with all accessories- 2Nos.

Qty

Unit

Rate (`) Amount (`)

2.4 L T Panel at Type -C electrical room. I/C comprising of the following: i) 400 A, TP MCCB with neutral bus bar & link with all accessories - 1No.. ii) R,Y,B LED Indication lamps with HRC fuses- 1 set. iii) 0-500 V 96 x 96 mm Voltmeter with selector switch & HRC fuses - 1 set. iv) Current transformers 400/5Amps, 10VA, Class-1.0 ( for metering) - 3 Nos. v) 0-400 A 96 x 96 mm Ammeter with selector switch. - 1 No. Busbars: 400 Amp TPN tinned copper busbar having maximum current density of 1.24 Amp/sq. mm to with stand symmetrical fault level of 50 KA at 415 V. The neutral busbar shall have 100 % capacity. R,Y,B LED Indication lamps with HRC fuses- 1 set for busbar Outgoing feeders : a) 400A, TP MCCB with neutral bus bar & link with all accessories - 1No. b) 200A, TP, MCCB with neutral bus bar & link with all accessories- 7Nos. c) 63A, TP, MCCB with neutral bus bar & link with all accessories- 2 Nos.

set

3.0 Feeder Pillar : Design, manufacture, supplying, fixing in position, testing and commissioning of feeder pillar with double door with detachable canopy, front operated, front access, 3mm thick MS CRCA sheet steel enclosed free standing, dust and vermin proof, Feeder Pillars with IP-55 protection with hinged and lockable doors complete with interconnections, copper crimping lugs, brass glands, bonding to earth and painting. Feeder Pillar shall be suitable for use at 415 volts, 3 phase 4 wire 50 Hz system, and with 35 KA rupturing capacity at 415 volts. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided. Scope includes suitable angle iron frame work for mounting arrangement 400 mm above ground level and 300mm pedestal below ground level necessary grouting, PCC base etc. Also scope incudes enclosing the supports by 3 mm thick MS CRCA sheet steel all around with detachable covers, etc all as per specification and instructions of E-I-C. Note: 1) The MCCBs shall be provided with microprocessor based overcurrent & short circuit release. 2) MCCBs shall be of minimum 35 KA Ics breaking capacity. 3) All Feeder Pillars shall be provided with RYB indication lamps (heavy duty LED cluster type) with HRC protection fuses.

Page No. 5 of 9

Sl. Description of Item No. 3.1 FP : (for type-E bldg) Incomer : a) 250A TPN MCCB with neutral bus bar & link with all accessories -1 no. b) RYB indication lamp with HRC fuses-1 set Bus bar : 250 A TPN tinned copper bus bar having maximum current density of 1.24 A/sq.mm to withstand symmetrical fault level of 50 kA at 415 V. The neutral bus bar shall have 100% capacity Outgoings : 1) 250A TPN MCCB with neutral bus bar & link with all accessories -1 No. 2) 160A TPN MCCB with neutral bus bar & link with all accessories -1 No. 3) 125A TPN MCCB with neutral bus bar & link with all accessories -1 No.

Qty 1

Unit set

Rate (`) Amount (`) 0

3.2 FP : (for type-D bldg) Incomer : a) 250A TPN MCCB with neutral bus bar & link with all accessories -1 no. b) RYB indication lamp with HRC fuses-1 set Bus bar : 250 A TPN tinned copper bus bar having maximum current density of 1.24 A/sq.mm to withstand symmetrical fault level of 50 kA at 415 V. The neutral bus bar shall have 100% capacity Outgoings : 1) 250A TPN MCCB with neutral bus bar & link with all accessories -1 No. 2) 125A TPN MCCB with neutral bus bar & link with all accessories -3 No.

sets

3.3 FP : (for type-C bldg) Incomer : a) 250A TPN MCCB with neutral bus bar & link with all accessories -1 no. b) RYB indication lamp with HRC fuses-1 set Bus bar : 250 A TPN tinned copper bus bar having maximum current density of 1.24 A/sq.mm to withstand symmetrical fault level of 50 kA at 415 V. The neutral bus bar shall have 100% capacity Outgoings : 1) 250A TPN MCCB with neutral bus bar & link with all accessories -1 No. 2) 200A TPN MCCB with neutral bus bar & link with all accessories -1 No. 3) 160A TPN MCCB with neutral bus bar & link with all accessories -1 No.

set

4.0 Change Over Switch: 4.1 Supply, Installtion, Testing & commissioning of 125 A , 415 V, 4 Pole, 3 -position on load change over switch in cubical type enclosure made out of 2 mm thick CRCA sheet with cable end boxes for incoming and outgoing cables, suitable for termination of 3.5 C x 95 sq. mm. XLPE cable at two incoming & one outgoing terminals, mounted on 40x40x6 mm angle frame, duly painted with two coats of primer & two coats of enamel paint, RYB indication lamps with fuses at both incomers, 125/5A , 10VA, cl1.0, 3nos current transformer with necessary fixing arrangement, 0-125A Ammeter with selector switch & as per instruction of EIC.

sets

Page No. 6 of 9

Sl. Description of Item No. 4.2 Supply, Installtion, Testing & commissioning of 200A , 415 V, 4 Pole, 3 -position on load change over switch in cubical type enclosure made out of 2 mm thick CRCA sheet with cable end boxes for incoming and outgoing cables, suitable for termination of 3.5 C x 150 sq. mm. XLPE cable at two incoming & one outgoing terminals, mounted on 40x40x6 mm angle frame, duly painted with two coats of primer & two coats of enamel paint, RYB indication lamps with fuses at both incomers, 200/5A , 10VA, cl-1.0, 3nos current transformer with necessary fixing arrangement, 0-200A Ammeter with selector switch & as per instruction of EIC. 5.0 MCCB Cubical : 5.1 Supply, Installtion, Testing & commissioning of 250A , 415 V, TP+N MCCB in cubical type enclosure made out of 2 mm thick CRCA sheet with cable end boxes for incoming and outgoing cables, suitable for termination of 3.5 C x 240 sq. mm. XLPE cable ( incoming & outgoing) with all accessories and mounting arrangement on wall, duly painted with two coats of primer & two coats of enamel paint, RYB indication lamps with fuses at incomer, & as per instruction of EIC.

Qty 1

Unit set

Rate (`) Amount (`) 0

no

5.2 Supply, Installtion, Testing & commissioning of 400A , 415 V, TP+N MCCB in cubical type enclosure made out of 2 mm thick CRCA sheet with cable end boxes for incoming and outgoing cables, suitable for termination of 3.5 C x 240 sq. mm. XLPE cable ( incoming & outgoing) with all accessories and mounting arrangement on wall, duly painted with two coats of primer & two coats of enamel paint, RYB indication lamps with fuses at incomer, & as per instruction of EIC.

no

6.0 Replacement MCCB : 6.1 Replacement of existing 300A TP&N MCCB with new 400A TP&N MCCB with neutral bus bar & link with all accessories in existing normal supply panel at Badrinath Sub Station encluding supply, installation, testing & commissioning of 400A TP&N MCCB & handing over of 300A TP&N MCCB to the department & as per instruction of EIC.

no

7.0 Earthing : Tinned copper earth wire/earth strip fixed on wall/side of trench/slab /column /beam /shaft connection to panel/DBs /SFU's/MCCB's etc. with 5mm. Thick G.I. Spacers & 2mm thick G.I. Saddle in ground at 750 mm. below including excavation in ground with protective baked bricks, excavation in ground, in all type of soil, refilling & removal of excess earth within a radius of 500 mtr.Temporary instatement & back filling of trench, consolidation, interconnection of earth strip/wire with brass bolt & nuts & washers &solder jointing, painting with two coats of black bituminous paint for earth wire / strip in ground & green enamel paint for earth wire /strip on surface etc. 7.1 25 x 6 mm tinned copper strip 7.2 25 x 3 mm tinned copper strip 7.3 4 SWG tinned copper wire 8.0 Excavation of earth: Excavation of earth in following.
Page No. 7 of 9

450 100 550

mtr mtr mtr

0 0 0

Sl. Description of Item Qty Unit No. 8.1 Excavation in murram for cable laying including shoring if necessary, dressing the 15 cu. M sides, trimming etc., (Cutting of asphalted road shall be measured against this item) as per the direction of E.I.C. 8.2 Excavation in hard rock for cable laying by chiselling or by using machines shoring if necessary, dressing the sides, trimming etc., as per the direction of E.I.C. 9.0 G I Pipe : Supply, installation of GI pipe of B class sleeves in beams /column /slab for passing electrical cables/conduit as per instruction of E-I-C. 9.1 40 mm dia 9.2 60 mm dia 9.3 80 mm dia 10.0 MS Fabrication Items: Supply, Fabrication & Installation of MS item of channel/angle/Flat as per instruction of E-I-C. 25 20 10 500 mtr mtr mtr kg 20 cu. M

Rate (`) Amount (`) 0

0 0 0 0

11.0 Cable Tray: Supply & Installation of following sizes of ladder type sheet metal hot dip galvanized cable trays with C profile side channel & C profile rung of spacing 300 mm centre to centre complete with horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling / wall with supporting arrangement hot dip galvanized MS angle / MS flat / MS channel / hangers / threaded rods etc. as required as per specifications and instructions of E.I.C. 11.1 300 mm (width) x 100 mm (height of side channel) x 1.5 mm thickness 11.2 450 mm (width) x 100 mm (height of side channel) x 1.5 mm thickness 12.0 Hume Pipe : Supply & installation of RCC Hume pipe to be laid in ground with necessary joints, concrete supports. Scope includes escavation in below ground level/in all types of soil/concrete road cutting/foot path cutting, nallah cutting /any RCC floor cutting including excavation, back filling, dewatering, consolidation, reinstatement as original,disposal of excess earth within the radius of 500 mtrs and making good to the original finish etc. Spares Hume pipe shall be sealed properly. 12.1 150 mm dia. 12.2 250 mm dia. 150 700 mtr mtr 0 0 50 50 mtr mtr 0 0

Page No. 8 of 9

Sl. Description of Item No. 13.0 Cable Markers: Supply, installation of oval/circular shaped G.I cable marker engraved as "MV Cable" complete with 32mm dia NB medium class G.I pipe support as per IS 1239 with 1:2:4 PCC base concreting, G.I nut,bolts including excavation in all types of soil to required depth and refilling etc., all as per drawing, specification and as instructions of E.I.C. Total

Qty 40

Unit nos

Rate (`) Amount (`) 0

0 0.00 0.00

Unconditional Rebate if any in percentage Total amount after rebate

Signature of Contractor With Seal


Note: 1. All cells with yellow background are to be filled compulsorily. 2. If any cell (Rate) is left Blank, then the same will be treated as "Zero".