Sunteți pe pagina 1din 6

O NT ER INUOUS S

A RS N WARRA

B8000 FXS | 10 - 40kVA

VI CE

T Y

C OF

YE

BORRI B8000 | FXS


With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical infrastructure device in the data centre. Interruption to electrical supply can cost organisations in excess of 100,000 per hour in lost revenues and productivity.
The innovative design of the Borri B8000FXS makes it one of the most technologically advanced UPS of its kind. Exclusively developed by Borri, the FXS series delivers an advanced combination of low input current distortion, unity power factor input, high overall eciency and maximum load protection ensuring ultimate power quality. This sophisticated arrangement of features make this series ideal for applications where reliability and high performance are fundamental. In addition, the FXS range comprises an IGBT input rectier design with dual DSP (Digital Signal Processing) and C (Micro Controller) technologies, which provides full digital control. The FXS conguration guarantees high quality output required by loads requiring a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Systems. VFI (Voltage & Frequency Independent) Online Double Conversion topology, provides built-in inverter galvanic protection, completely isolating the output of the UPS from mains power problems. This advanced design oers an extensive range of user benets including achieving high eciency without compromising load protection. > 3 Year Warranty > High Eciency > Transformer Free Design

3 Year | Warranty
A 3 year warranty is standard on all Borri B8000FXS UPS. We are able to oer such an impressive warranty due to the superior reliability and condence in our product.
A RS N WARRA
T Y
YE

To the best of our knowledge no other UPS manufacturer can boast such a lengthy warranty. Not only does this give the user peace of mind but also has the added benet of reducing on-going maintenance costs.

As the AC input is always converted to DC and then converted back to AC, the double conversion process provides complete electrical isolation of the output from the input, in fact unless the inverter is switched o the critical load will never see the raw mains power.

Enhanced Compatibility with Mains & Generators


The B8000 FXS uses an IGBT input rectier design, encompassing an advanced PFC (Power Factor Correction), which maintains input current THDi (Total Harmonic Distortion of the input) at a level of

Online Double Conversion


Ultimate protection for all loads from computer rooms and small datacentres to industrial applications, the B8000FXS incorporates Online Double Conversion or VFI (Voltage and Frequency Independent) topology.

less than 3% and an input power factor within 1% of unity, even when only small loads are applied. Main benefits for the user: > The installation of the UPS is simplied > Upstream electrical supplies and cables do not have to be

In online double conversion mode the output voltage and frequency are constantly generated by the inverter and so are isolated from any input power disturbances, spikes, dips or outages. For maximum protection, the batteries are positioned in the conversion circuit to ensure there is no break or switching should the need arise for them to power the load.

heavily overrated to cope with high harmonic distortion > Standby generators can typically be downsized by 40% > Users can extract more output power from their current supply increasing load capacity > Eciency is massively increased, typically 20%!

This technology allows for an extremely wide range of input voltage and frequency, whilst enabling the UPS to control perfect output conditions without having to use battery power. > Reduced charges from your energy supplier > THDi <3% with Input power factor >0.99

B8000FXS Main Features


Online Double Conversion Topology Smart Online Function 98% Efficiency
UPS Block Diagram

3xL-N

Scalable up to 8 units in parallel Temperature Compensated Battery Charging Front Access Back Feed Protection High Level Diagnostics via LCD Screen Dual DSP Controller Enhanced Generator Compatibility

High Efficiency
Dedicated to traditional UPS design, we know that a UPS operating in true online double conversion mode (VFI) oers a higher level of protection over Line Interactive (VI), or Oine (VFD) topologies. Historically this has resulted in poor operating eciency, however, investment at component level in the design of B8000 FXS means that the FXS range, can perform with overall eciency levels of greater than 95% through mid-range loadings. This impressive operational rating provides the user with true eciency without compromise. > Overall efficiency in excess of 95% at half load running in full online double conversion mode. > Smart Online eciency of up to 98%

Ultra High Efficiency - Smart Online (SOL)


Whilst we advocate that ultimate protection is only achieved with Online Double Conversion mode, we also understand that in some situations users will require ultimate eciency. With this in mind, the FXS series now features smart online mode (SOL). This mode signicantly reduces energy consumption as the load is fed primarily through the bypass line. The SOL function continually monitors the input characteristics of the supply and the UPS switches to Inverter within 2mS should the control system experience any anomalies. This mode is perfect for achieving a reduced data centre PUE.

www.borri.co.uk

Parallel
Oering parallel options for redundancy or capacity modes, the B8000 FXS can add future resilience or scalable growth. Up to 8 units can be connected in parallel giving a total scalable power output of 320kVA. The FXS series incorporates fully digital, parallel control circuitry and acts on both active and reactive power on each phase of the UPS outputs. This allows accurate load current sharing among the UPS units even during transient conditions. Parallel control is distributed between all units and communication is achieved through the use of a CAN BUS connection loop. This eliminates any single point of failure within the system and increases reliability. Intelligent design of the system connections allow for easy installation and future additions without the need for a power down.
Mains

In the modular arrangement units can be added or removed whilst the system is supporting a load. The smart parallel function enables individual units to shut down based on the load applied, delivering optimum eciency whilst maintaining redundancy. Two independent parallel systems can be synchronised to feed downstream STS for seamless transfers. > 8 units in parallel conguration (up to 320kVA) > Output synchronisation of separate parallel systems > Smart parallel with load based shutdown

Load

Easy Installation, Operation and Maintenance


The B8000FXS is designed with three individual power modules with access from the front for installation and maintenance. This means the units can be installed close to walls and adjacent equipment providing a signicant reduction in oor space. As all critical components are accessible from the front of the unit, regular maintenance can be completed with ease. For increased exibility, the B8000FXS modules can easily be removed for delivery and positioning. The modules can then be re-mounted during the commissioning.

BORRI B8000 | FXS


Technical Specification
POWER - KVA Capacity (kVA) Dimensions WxDxH (mm) Weight (kg) w/o battery with battery Input/output connection Battery INPUT Nominal voltage Voltage range Frequency Power factor Current distortion (THDi) OUTPUT Nominal voltage Frequency Voltage regulation PF acceptable without de-rating Overload capacity Efficiency EPS (Eco-mode) Options USER INTERFACE Front panel Standard communication ports Optional ENVIRONMENTAL Operating temperature Storage temperature Altitude Audible noise at 1 meter (dBA) STANDARDS & CERTIFICATION Marking Safety EMC Test and Performance Quality 10 kVA 3/1 10 10 kVA 3/3 15 kVA 3/3 20 kVA 3/3 30 kVA 3/3 40 kVA 3/3 10 15 20 30 40 450x650x1200 90 100 100 90 100 100 141 141 250 260 260 250 260 260 Hardwired (dual input) Hardwired (optional dual input) Internal or external, 372 cells External, 372 cells 220/380, 230/400, 240/415 VAC three phase -20%, +10% from nominal 50/60 Hz (4565 Hz) 0,99 3% 220/380, 230/400, 240/415 VAC three phase 50/60 Hz 1% static; 2% dynamic 100% load change, <10 ms recovery time Lagging to 0.9 leading 101125% for 10 min (on-line); 126150% for 1 min (on-line); 500% for 1 cycle (bypass) >95% >98% Parallel capacity/redundancy; isolation transformer; external bypass; external battery cabinets, battery switch box; battery thermal probe; transformers/ autotransformers for voltage adaptation; Graphical LCD display, mimic with LEDs and keyboard RS232 serial port, USB port, Emergency Power Off input, battery switch monitoring port Web/SNMP, ModBus, relay, modem cards; remote panel; shutdown and monitoring software 0C +40C -10C +70C <1000 m <60 CE IEC EN 62040-1 IEC EN 62040-2 IEC EN 62040-3 ISO9001 :2000 220, 230, 240 VAC single phase
The data and text contained within this brochure are for general information only and can not be deemed as definitive, specifications can change without notice.

15 kVA 3/1 15

20 kVA 3/1 20

Front view of B8000FXS

Rear view of B8000FXS

BORRI LTD Systems House Rotherside Road Eckington Sheffield S21 4HL Tel: +44 (0)1246 431431 Fax: +44 (0)1246 431444 Email: sales@borri.co.uk Web: www.borri.co.uk BORRI S.p.A Via 8 Marzo, 2 52010 Bibbiena (Arezzo) Italy Tel: +39 0575 5351 Fax: +39 0575 561438 Email: info@borri.it Web: www.borri.it