Analysis of Shallow Foundations in Cohesionless Soil Using The Extended Bearing Capacity Equation
Rev # 1 2 3 4 5 Revision Description Revised By Date
Notes 1 2 3 4 5
1 of 5
Analysis of Shallow Foundations in Cohesionless Soil Using The Extended Bearing Capacity Equation
Description: This worksheet will provide the allowable capacity of shallow footings in cohesionless soil. This worksheet is applicable for square, rectangular, circular, and strip footings. This work sheet only looks at footing geometry and soil properties when calculating the capacity and is not applicable for uplift, eccentric or inclined loading, or footings in other than cohesionless soil. Capacity is calculated using the Extended Bearing Capacity Equation. The user must input soil properties, footing geom etry, and the axial load and factor of safety for the footing.
Notes: According to The Extended Bearing Capcity Equation. Only applicable for cohesionless soils.
2 of 5
Inputs
Soil Properties
Soil Type
Unit Weight of Soil Below Foundation Level Unit Weight of Soil Above Foundation Level Soil Friction Angle
Foundation Properties
Footing Shape
D f := 5 ft B := 5 ft L := 5 ft
Depth to Base of Footing Width of Footing Length of Footing (Only needed for rectangular footings)
Loading
Q := 70 kip FS := 2.5 Load on Footing (Load per linear foot for Strip Footings) Factor of Safety
3 of 5
Calcualations
Footing Parameters
Area = 25 ft
2
Area of Footing
Shape Factors
Depth Factors
4 of 5
Calculations (continued)
Bearing Capacity
Extended Bearing Capacity Equation 1 q net := c N c rc sc dc + B 1 N r s d + 2 D f N q 1 rq sq dq 2
)(
q allow :=
q allow = 5014 psf Q allow := q allow Area Q allow = 125.3 kip Allowable Load Capacity
Results
Q allow = 125.3 kip Allowable Load on Footing (Load per linear foot for Strip Footings)
Check :=
Q Q allow
= 55.8 %
5 of 5