Sunteți pe pagina 1din 24

sorinc.

com 913-888-2630
Mini-Hermet pressure switches
are robust eld-mounted instruments. The pressure sensing assembly is similar to a conventional
SOR type. The main difference is that the switching element assembly is hermetically sealed in
an explosion proof steel capsule. Switching elements are
SPDT or DPDT. See Principle description on page 2.
Application Information
The pressure switches in this catalog are suitable for a
variety of process applications in hazardous locations
and hostile environments where stainless steel exterior
parts are required and where space is limited. Basic
models with standard wetted parts are normally suitable
for air, oil, water and non-corrosive process uids. See
the Quick Selection Guide on page 4.
Corrosive service and particular user requirements may
require optional components. See How to Order on
page 3. Adjustable ranges to accommodate lower
Set Points, switching elements to handle heavier
electrical loads and user preference may require Big
Hermet models.
High pressure uid power (hydraulic) applications where
high shock pressures and high cycle rates are expected
normally require Pivot Seal type pressure switches.
Mini-Hermet
Pressure Switches
Form 456
Registered Quality System to ISO 9001:2008
2/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Principle
Mini-Hermet
Pressure Switches
F
e
a
t
u
r
e
s

a
n
d

B
e
n
e

t
sBuilt-In Quality
Rigid quality standards maintained from
raw material to nished product.
Explosion Proof Hermetically Sealed
Switching Capsule
Isolates switching elements from corrosive,
hostile and hazardous environments and
virtually eliminates problems from corrosion.
UL Listed, CSA Certied, ATEX and
SAA Approved Models
Meet most code and customer
requirements.
Safety Certied to IEC 61508 (SIL)

SOR products are certied to IEC 61508
for non-redundant use in SIL1 and SIL2
Safety Instrumented Systems for most
models. For more details or values
applicable to a specic product, see
the Safety Integrity Level Quick Guide
(Form 1528).
Field Adjustable Set Points
Full range adjustability without disconnecting
electrical power while maintaining explosion
proof integrity, self-locking adjustment, no
charge for factory calibration.
Warranty
3 years from date of manufacture.
Instrument Quality
High resolution of Set Points, high repeatability,
narrow dead band, negligible temperature
effect, high overrange and proof pressures.
Robust Construction
High cycle rate tolerance, long life, not critical
to vibration, protected internal hermetically
sealed switching element capsule.
Cost Effective
Simple, fast installation without special tools,
long service life. Periodic service or spare parts
not required.
Delivery
Routine shipments 7 to 10 working days.
Emergency shipments via air within 48 hours.
Service
Factory service engineers and area factory rep
resentatives provide effective and prompt
worldwide service.
The pressure sensing element of the SOR Pressure
Switch is a force-balance, piston-actuated
assembly. The sensing element is sealed by a
exible diaphragm and a static o-ring. There are
only three wetted parts in this arrangement: a
pressure port, a diaphragm and an o-ring. A wide
selection of wetted parts materials for media
compatibility and containment are available. A
metal diaphragm may be welded to the pressure
port for certain applications, thereby eliminating the
o-ring (Designators U8 and U9).
Media pressure on the piston counteracts the force
of the range spring (adjustable by the adjusting
screw) which moves the piston shaft only a few
thousandths of an inch to directly actuate the
electrical snap-action switching element that is
enclosed in the hermetically sealed steel capsule.
This design results in low friction and virtually no
wear. The electrical switching element is isolated
from corrosive atmospheres.
1/2 NPT(M)
Electrical
Connection
Buna-N
O-Ring
Electrical
Switching
Elements
Explosion
Proof Hermetically
Sealed Switching
Element Capsule
Actuator Lever
Assembly
Agency Approvals
& Ratings Tag
for Switching
Element Capsule
Piston Shaft
Nameplate:
Data Bearing
and Agency
Approvals/
Ratings
U8 Fire-Safe
Welded
Diaphragm
System
Pressure Port
Factory
Sealed
Electrical Leads
Glass-to-Metal
Seal
Weathertight
Cap
Weathertight
Gasket and
Cap Retainer
Set Point
Adjusting Screw
External Ground
Lug BG,
BH, & JH
Housing Only
Range Spring
Piston Assembly
O-Ring
(Not Installed
on Welded
Diaphragm Systems)
Viton O-Ring
Weathertight Seal
3/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Quick Selection Guide
Basic Mini-Hermet pressure switches in AG or AH housings with standard wetted parts are normally
suitable for air, oil, water and non-corrosive process applications in hazardous locations and hostile
environments where space is limited. Refer to the Quick Selection Guide section on page 4 for a basic
model number. Corrosive service and particular customer requirements may require optional components.
Refer to the How to Order section below to build a customized model number or the dedicated page to locate
optional components, such as: switching elements, diaphragm systems, pressure ports and accessories.
Each position in the model number, except Accessories, must have a designator.
6AG-EF3-M4-C2A-YY
Model Number System
Diaphragm
& O-Ring
Housing Piston Switching
Element
Range
Spring
Pressure Port Accessories
Applications
Mini-Hermet pressure switches in the AG and AH housings are normally suitable for a variety of process
applications in hazardous locations and hostile environments because the electrical switching elements are
hermetically sealed in a stainless steel capsule that is UL Listed, CSA Certied, ATEX and SAA Approved as
an explosion-proof snap switch. Specic customer or code requirements for the complete pressure switch
to be UL Listed, CSA Certied or ATEX Approved can normally be met by specifying an AP, AS, BG, BH or
JH housing and U8 diaphragm system. See pages 6, 7, 8 and 10 for details. Other application requirements
can normally be met by selecting optional components, such as: switching elements, diaphragm systems
and pressure ports. Certain applications may require customized specials. Consult the factory or the SOR
representative in your area. Conventional explosion-proof pressure switches for process applications are
shown in Form 216.
High-pressure uid power (hydraulic) applications where high shock pressure and high cycle rates are
expected normally require Pivot Seal type pressure switches. Refer to SOR Catalog 219.
How to Order
Information and data in this catalog are formatted to provide a convenient guide to assist instrument
engineers, plant engineers and end users in selecting pressure switches for their unique applications.
Steps 1 through 5 required. Step 6 optional. Orders must have complete model numbers, i.e. each
component must have a designator.
Step 1: Select Piston-Spring Adjustable Range/Set Point from Specication (page 5).
(Piston/Spring combination determines adjustable range.)
Step 2: Select Housing for type of pressure switch and service (page 6).
Step 3: Select electrical Switching Element for electrical service (page 7).
Step 4: Select Diaphragm and O-Ring for process compatibility and containment (page 8).
Step 5: Select Pressure Port for process compatibility and connection (page 9).
Step 6: Select Accessories required for service (page 11).
If Agency Approved, Certied or Listed pressure switches are required, see page 12 for components that
must be specied.
How to Order
Mini-Hermet
Pressure Switches
4/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Quick Selection
Mini-Hermet
Pressure Switches
Basic Mini-Hermet pressure switches with AG - Aluminum or AH - Stainless Steel housings and
standard wetted parts are normally suitable for air, oil, water and non-corrosive processes in
hazardous locations and hostile environments. The Set Point must be within the adjustable range.
Refer to How to Order section on page 3 to locate optional components. Each position in the model
number, except Accessories, must have a designator.
Pressure
Standard Construction
1. Housing: AGAluminum or AH - Stainless Steel. See Housing and Dimensions pages for
details.
2. Switching element: EFSPDT 5A 250 VAC. See Switching Element page for optional
switching elements.
3. Diaphragm & O-Ring: N4primary (wetted) diaphragm TCP, o-ring (wetted) Buna-N. See
Diaphragm & O-Ring page for optional diaphragm and o-ring systems.
4. Pressure port: F1ACarbon steel 1/4 NPT(F). When AH - Stainless Steel housing is specied,
pressure port must be C1A - 316SS 1/4 NPT(F). See Pressure Port page for optional
pressure ports.
5. Dead band values are expressed as typical expected at mid-adjustable range with the
standard EF switching element assembly installed. See Dead Band Considerations on page 7.
Vacuum
Model Number
Adjustable Range
psi
Typical
Dead Band
psi
Overrange
psi
Proof
psi
6AG - EF2 - N4 - F1A 7 to 30 1.6
1500 2500
6AG - EF3 - N4- F1A 12 to 100 2.7
6AG - EF5 - N4 - F1A 20 to 180 4.2
6AG - EF45 - N4 - F1A 25 to 275 5.7
5AG - EF3 - N4 - F1A 25 to 240 6.6
5AG - EF5 - N4 - F1A 35 to 375 9.3
5AG - EF45 - N4 - F1A 45 to 550 11.7
9AG - EF4 - N4 - F1A 100 to 500 15.9
2500 6000 9AG - EF5 - N4 - F1A 200 to 1000 27.6
9AG - EF45 - N4 - F1A 200 to 1750 45
1AG - EF45 - N4 - F1A 500 to 4000 294 5000 6000
Model Number
Adjustable Range
in. Hg vacuum to
pressure
Typical
Dead Band
in. Hg
Overrange
psi
Proof
psi
56AG - EF216 - M2 - C1A 30 - 0 - 20 2.5
1500 2500
56AG - EF316 - M2 - C1A 30 - 0 - 160 3.5
5/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches
This table is a listing of piston-spring combinations and the corresponding adjustable ranges, dead
bands, overrange and proof pressures. Adjustable range is expressed for increasing pressure; the
Set Point must be within the adjustable range. Dead band is expressed as typical. See Dead Band
Considerations at the bottom of switching element page 7.
Step 1: Pressure Specication
6AG-EF3-M4-C2A-YY
Step 1: Vacuum Specication
56AG-EF216-M4-C2A-YY
This table is a listing of pistonspring combinations and the corresponding adjustable ranges, dead
bands, overrange and proof pressures. SOR vacuum switches are compound; they will operate in
either vacuum or pressure modes. Adjustable range is expressed from maximum vacuum decreasing
to zero gauge and increasing to maximum pressure. Dead band is expressed as typical. See Dead
Band Considerations on bottom of page 7. The Set Point must be within the adjustable range. A
vacuum switch is generally better suited than a pressure switch for Set Points very near zero guage.
Notes
1. Dead band values are expressed as typical expected at mid-range with the standard EF
switching element assembly installed. When optional switching elements are specied,
corresponding dead band multipliers shown on page 7 must be applied.
2. Special ranges may be possible. Consult the factory or the SOR representative in your area.
3. Diaphragms may have an additional effect on dead band. Consult the factory. See Notes on page 8.
4. Metric bar (mbar) values are practical equivalents of the reference English values; not
necessarily exact mathematical conversions. This data appears on the product nameplate
when metric engineering units are specied.
Piston-Spring
Designator
Adjustable Range Typical Dead Band Overrange Proof
psi bar psi bar [mbar] psi bar psi bar
6 - 2 7 to 30 0.5 to 2 1.6 [114]
1500 100 2500 170
6 - 3 12 to 100 0.8 to 7 2.7 [184]
6 - 5 20 to 180 1.4 to 12 4.2 [289]
6 - 45 25 to 275 1.7 to 19 5.7 [393]
5 - 3 25 to 240 1.7 to 16 6.6 0.5
5 - 5 35 to 375 2.4 to 26 9.3 0.6
5 - 45 45 to 550 3.1 to 38 11.7 0.8
9 - 4 100 to 500 7 to 35 15.9 1.0
2500 170 6000 410 9 - 5 200 to 1000 14 to 70 27.6 1.9
9 - 45 200 to 1750 14 to 120 45 3.1
1 - 45 500 to 4000 35 to 275 294 20.3 5000 340 6000 410
Piston-Spring
Adjustable Range
Vacuum - O Pressure
Typical Dead Band
Vacuum Mode
Overrange Proof
in. Hg bar in. Hg [mbar] psi bar psi bar
56 - 216 30 - 0 - 20 1.0 - 0 - 0.7 2.5 [85]
1500 100 2500 170
56 - 316 30 - 0 - 160 1.0 - 0 - 5.4 3.5 [120]
Design and specications are subject to change without notice. For latest revision, see www.sorinc.com.
6/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches Step 2: Housing
6AG-EF3-M4-C2A-YY
Note
Mini-Hermet pressure switches with AG and AH housings are not agency listed, certifed or approved.
However, the hermetically sealed electrical switching element capsules in them are UL Listed, CSA
Certied and SAA Approved as explosion-proof snap switches for hazardous locations. See page 14 for
dimensional details.
*Consult the factory.
Service Description Designator
Hazardous Locations
(UL Listed, CSA
Certied & SAA
Approved Snap Switch)
Housing contains explosion-proof snap switch for hazardous
locations and hostile environments. UL Listed, CSA Certied
Class I, Group A, B, C, D; Class II, Group E, F, G, Divisions 1& 2
and SAA Approved Ex s Zone 2 IIC T4 IP65, Ex tD A22 T105C
IP65. See details Note 3, page 7. Electrical conduit connection
1/2 NPT(M). NEMA 4, 4X, IP65, IP66, IP67.
Material: Copper-free aluminum*.
AG
Hazardous Locations
(UL Listed, CSA
Certied & SAA
Approved Snap Switch)
Housing contains explosion-proof snap switch for hazardous
locations and hostile environments. UL Listed, CSA Certied
Class I, Group A, B, C, D; Class II, Group E, F, G; Divisions 1 & 2
and SAA Approved Ex s Zone 2 IIC T4 IP65, Ex tD A22 T105C
IP65. See details Note 3, page 7. Electrical conduit connection
1/2 NPT(M). NEMA 4, 4X, IP65, IP66, IP67.
Material: Stainless steel.
AH
Hazardous Locations
(UL Listed/CSA
Certied Pressure
Switch)
UL Listed and CSA Certied pressure switch
Class I, Group A, B, C, D; Class II, Group E, F, G; Divisions 1 &
2 for hazardous locations and hostile environments. See details,
page 12. U8 re-safe diaphragm system designator required.
Electrical conduit connection 1/2 NPT(M).
NEMA 4, 4X, IP65, IP66, IP67.
Material: Copper-free aluminum*.
AP
Hazardous Locations
(UL Listed/CSA
Certied Pressure
Switch)
UL Listed and CSA Certied pressure switch
Class I, Group A, B, C, D; Class II, Group E, F, G; Divisions 1 &
2 for hazardous locations and hostile environments. See details,
page 12. U8 re-safe diaphragm system designator required.
Electrical conduit connection 1/2 NPT(M).
NEMA 4, 4X, IP65, IP66, IP67.
Material: Stainless steel.
AS
Flammable Atmospheres
(ATEX Approved
Pressure Switch)
ATEX Approved pressure switch
EEx d IIC T5 or T6 per EN 50-014 & 018 for ammable
atmospheres and hostile environments. See details, page 12.
Electrical conduit connection 1/2 NPT(M). NEMA 4, 4X, IP65.
Material: Copper-free aluminum*.
BG
Flammable Atmospheres
(ATEX Approved
Pressure Switch)
ATEX Approved pressure switch
EEx d IIC T5 or T6 per EN 50-014 & 018 for ammable
atmospheres and hostile environments. See details, page 12. Electri-
cal conduit connection 1/2 NPT(M). NEMA 4, 4X, IP65, IP66, IP67.
Material: Stainless steel.
BH
7/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches Step 3: Switching Element
6AG-EF3-M4-C2A-YY
Notes
1. AC/DC electrical ratings in the table above are UL
Listed, CSA Certied, ATEX, SAA and JIS/RIIS
Approved with the following conditions and exceptions:
a) JF and JG are not SAA and JIS/RIIS Approved.
b) DC electrical ratings are for resistive loads only.
c) DC ratings marked with an asterisk (*) are not
agency approved, certied or listed but have been
veried by testing or experience.
d) AF, AG, JF and JG are also ATEX Approved for 0.5
amps 125 VDC (resistive) when used with a BG or
BH housing.
2. Switching Elements AG, EG and JG have two separate
SPDT switching elements that are operated by a
single lever for DPDT switching action. Simultaneous
actuation or deactuation occurs at both increasing and
decreasing Set Points. Two independent electrical
circuits can be simultaneously switched, i.e. one AC
and one DC.
3. The hermetically sealed switching element capsule is
UL Listed, CSA Certied, ATEX and SAA Approved as
an explosion-proof snap switch per the table to the
right.
4. Ambient Temperature Limits: 40 to 167F
(40 to 75C)
5. Electrical connections are 18 18 AWG color-
coded stranded wire leads unless Accessory TB, HT,
HB or HMBE (electrical junction box with screw
terminals) are specied.
6. Wire Lead Color Code
EF, AF, JF Red NC (Normally Closed)
Black NO (Normally Open)
Blue C (Common)
Green G (Ground - Earth)
EG, AG, JG Red NC1 (Normally Closed - 1)
Black NO1 (Normally Open - 1)
Blue C1 (Common - 1)
Orange NC2 (Normally Closed - 2)
Brown NO2 (Normally Open - 2)
Yellow C2 (Common - 2)
Green G (Ground - Earth)
Dead Band Considerations
CAUTION: The hermetically sealed switching element
capsule
assembly has been precisely positioned in the housing;
over-travel has been precisely adjusted and secured at the
factory for optimum performance. Field replacement of the
capsule is not practical and is not recommended. Removal or
breakage of the tack weld voids the warranty. Movement of the
capsule in the housing will degrade performance and could
render the device inoperative.
1. Dead band values are expressed as typical expected at
mid-range with the standard EF switching element
assembly installed. When optional switching elements
are specied, corresponding dead band multipliers
must be applied.
2. Dead bands are xed (non-adjustable).
3. Dead band can be widened by selecting an optional
switching element with a multiplier greater than 1.0.
Example: Model 5AH-AG3-M4-C2A-YY
Typical Dead Band: 6 psi
AG Switching Element multiplier = 3.0
Typical Dead Band corrected for AG switching element:
6 x 3.0 = 18 psi
Agency Hazardous Location Conditions Designator
UL Listed
CSA
Listed
Class I, Group A, B, C, D
Class II, Group E, F, G;
Divisions 1 & 2
AF, EF, AG,
EG, JF, JG
SAA
Approved
Ex s Zone 2 IIC T4 IP65
Ex tD A22 T105C IP65
AF, EF, AG,
EG, JF, JG
ATEX
Approved
II 2 G EEx mII
AF, EF, AG,
EG, JF, JG
Switching Element Designators Multiplier
EF, JF 1.0
AF 1.5
EG, JG 2.0
AG 3.0
Service
Contact
Form
Electrical
Connection
AC Rating
(See Note 1)
DC Rating
(See Note 1)
Dead Band
Multiplier
Designator
volts amps volts amps volts amps
Normal AC/DC
SPDT 18 18 AWG
Color-Coded
Standard
Wire Leads
1/2 NPT(M)
Conduit
Connection
250
11 125 .5* 30 5 1.5 AF
5 125 .5* 30 5* 1.0 EF
DPDT
11 125 .5* 30 5 3.0 AG
5 125 .5* 30 5* 2.0 EG
Gold Contacts
for Low Power
Data Acquisition
Interface
SPDT
125
1 - - 30 1 1.0 JF
DPDT 1 - - 30 1 2.0 JG
8/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Notes
1. N4 diaphragm system is standard, but requires a
designator in the model number. It is normally
suitable for air, oil, water and non-corrosive
processes. M2 diaphragm system is standard on
Number 56 vacuum switches.
2. U8 designates the welded re-safe diaphragm
system. U8 must be specied for the complete
pressure switch to be UL Listed and CSA
Certied; it may be specied on ATEX Approved
models. See pages 10 and 12. 316SS is stocked.
Not available on Number 1 piston or vacuum
switches. Example: U8-C2A is a 316SS re-safe
welded diaphragm system.
3. U9 designates a welded diaphragm system. Not
available on vacuum switches. Example: U9-A1A
is a Monel welded diaphragm system. See page 10.
4. Other diaphragm and o-ring combinations may be
available. Consult the factory or the SOR
representative in your area for more information.
5. Wetted parts have been selected as representing
the most suitable commercially available material
for use in the service intended. However, they do
not constitute a guarantee against corrosion or
permeation, since processes vary from plant to
plant and concentration of harmful uids, gases
or solids vary from time to time in a given
process. Empirical experience by users should be
the nal guide. Alternate materials based on this
are generally available.
6. Specify N3 diaphragm system for high cycle rate,
high shock applications where Buna-N and TCP
are compatible with the process.
7. This table shows allowable minimum and
maximum temperatures for o-rings. Consult the
factory for temperatures down to 65F on
re-safe and welded metal diaphragm systems.
8. Dead bands are slightly higher when using H,
N3, N6, J4, J6, U or W series diaphragm options.
Consult Factory.
9. Diaphragm systems U8, U9 are not available on
Number 56 vacuum switches.
10. M9 diaphragm system is suitable for steam
applications up to 400
o
F.
Mini-Hermet
Pressure Switches Step 4: Diaphragm and O-Ring
6AG-EF3-M4-C2A-YY
O-Ring Material F C
Viton 32 to 400 0 to 204
Viton GLT -20 to 400 -29 to 204
Kalrez* 5 to 400 -15 to 204
Aas 25 to 400 -4 to 204
Buna-N Neoprene EPR -30 to 200 -34 to 93
Fire-Safe/Welded
Disphragm System
-30 to 400 -34 to 204
TCP-Teon Coated
Polyimide Diaphragm
-30 to 400 -34 to 204
*Kalrez or equivalent Perfuoroelastomer (FFKM) o-rings
O-Ring
(Wetted)
Diaphragm
(Wetted)
Designator
Viton
Monel
A4
Kalrez A6
Viton
Hastelloy-B
H4
Kalrez H6
Viton
Hastelloy-C
J4
Kalrez J6
Viton
Carpenter-20
L4
Kalrez L6
Viton GLT
316L SS
M1
Buna-N M2
Viton M4
Neoprene M5
Kalrex M7
Aas M8
EPR
M9 (See Note
10)
Viton
TCP
Teon-Coated
Polyimide
N1
Buna-N
N3
(See Note 6)
Buna-N
N4
Standard
(See Note 1)
Kalrez N5
Kalrez Kalrez N6
EPR TCP
Teon-Coated
Polyimide
N7
Aas N8
Buna-N Buna-N P1
Neoprene Neoprene R1
Viton
Viton
S1
Viton GLT S2
Buna-N
Tantalum
W2
Viton W4
Neoprene W5
Kalrez W6
EPR
Ethylene
Propylene
EPR
Ethylene Propylene
Y1
None Fire-Safe Welded
U8
(See Note 2)
None Welded
U9
(See Note 3)
9/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches Step 5: Pressure Port
6AG-EF3-M4-C2A-YY
Notes
1. Select designator for material and connection
size. Large bold face designators denote those
items generally available from stock. Small light
face designators denote items with limited
stock and possible long delivery.
2. 1/4 and 1/2 tapered BSP(F) pressure
(designated B instead of A in the 3rd
position) ports are available.
3. The standard material and connection size for
Numbers 6, 5, 9 & 1 pressure ports with:
aluminum housing is F1A - 1/4 NPT(F) carbon
steel; stainless steel housing is C1A -
1/4 NPT(F) 316SS.
4. Brass not available on Piston Numbers 9 and 1.
5. Other materials such as PVC, Kynar, etc., are
available. Denote unlisted material by
specifying an X followed by the required
connection size, and describe the material.
Examples:
X2A = PVC pressure port with 1/2 NPT(F)
connection.
X1A = Titanium pressure port with
1/4 NPT(F) connection.
Non-metal pressure ports generally reduce
proof pressure and may reduce overrange
pressure. The pressure port material may
limit the process temperature. Delivery may
be longer than normal.
See the next page for presentation of welded diaphragm and FM Approved fre-safe systems.
Piston 6, 5, 9, 1 56
Process
Connection Size
1/4 NPT(F) 1/2 NPT(F) 3/4 NPT(M) 1/4 NPT(F) 1/2 NPT(F)
Carbon Steel Ledloy
AX Wrought
F1A
(Standard)
F2A F3A N/A N/A
316SS/316LSS
Wrought
C1A C2A C3A C1A C2A
347 Stainless Steel
Wrought
E1A E2A E3A
Consult the factory for
availability of Pressure Port
Material and Process
Connection Size
Carpenter 20 Stainless
Steel Wrought
L1A L2A L3A
316L Stainless Steel
Low Carbon
Z1A Z2A N/A
Brass (See Note
4) Half Hard Yellow
Wrought
D1A D2A D3A
Hastelloy B H1A H2A H3A
Hastelloy C J1A J2A J3A
Monel A1A A2A A3A
P
r
e
s
s
u
r
e

P
o
r
t

M
a
t
e
r
i
a
l
10/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches
Welded Diaphragm
& Fire-Safe Systems
Designator Description
Fire-Safe Welded Diaphragm System
Factory Mutual System Approved-
U.S. Patent Number 4,438,305
Tested in ames at 1900
o
F for periods up to 30 minutes while
pressurized to the rated overrange pressure.
A metal diaphragm, the cylinder disc and the pressure port
are welded as a unit, thereby, eliminating the o-ring. This
arrangement may be indicated for extremely corrosive, hot, harsh
or volatile process where o-rings are not suitable. See the re-
safe denition on page 13.
316SS is standard. Hastelloy B and C, Monel are available with
possible longer lead times: The pressure port designator
determines the material.
Example: U8-C2A
U8 = Fire-safe welded diaphragm system
C2A = 1/2 NPT(F) 316SS pressure port
Note
1/2 NPT(F) is stocked; 1/4 NPT(F) is not stocked and has a
longer lead time. Not available on Number 1 piston and vacuum
switches.
Welded Diaphragm System
A metal diaphragm is welded to the pressure port, thereby,
eliminating the o-ring.
This arrangement may be indicated for extremely corrosive, hot
or harsh process where o-rings are not suitable.
316SS is standard. Hastelloy B and C, Monel are available
with possible longer lead times: The pressure port designator
determines the material.
Example: U9-A2A
U9 = Welded diaphragm
A2A = 1/2 NPT(F) Monel pressure port
Note
Not available on vacuum switches.
Piston
Shaft
Spring
Stop
Cylinder
Disc
Diaphragm
Pressure
Port
Diaphragm
Pressure
Port
U8
U9
Approved
11/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches Step 6 : Accessories
6AG-EF3-M4-C2A-YY
Accessory/Option & Description Designator
Wetted parts are cleaned for industrial oxygen service. BB
Canadian Registration Number (CRN) - Process ratings may be affected. Consult the factory for details. CV
CSA Dual Seal Approval. See Agency Listings on page 12 for details. DS
Universal terminal box, 1/2 NPT(F). 316SS. Explosion proof. ATEX Certied EEx d IIC T4, T5, T6. HB
Universal terminal box, M20 x 1.5(F). 316SS. Explosion proof. ATEX Certifed EEx d IIC T4, T5, T6. HBME
Universal terminal box, 1/2 NPT(F). 316SS. Explosion proof. FM Approved; CSA Certifed. HT
Vacuum protector plate. Retains diaphragm system in pressure switch if subjected to intermittent vacuum greater
than 10 in. Hg. If a pressure switch is subjected to continuous, rapid changes of vacuum, other protection may be
available (consult factory). Material matches or exceeds pressure port material. N/A on Pistons 52, 54, or 56.
MM
Compliance to NACE Certifcation MR0175/ISO 15156. NC*
Pipe (stanchion) mounting kit for (1-1/2 to 2 pipe.) PK
Tag, ber. Attached with plastic wire to housing. Printed with customer-specied tagging information. PP
Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) PY
Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer-specied tagging
information. (2 lines, 18 characters and spaces per line.)
RR
Explosion-proof and weathertight electrical junction box with screw terminals. Aluminum 3/4 NPT(F) top, left
or right conduit connections as required. UL Listed and CSA Certied Class I, Groups A, B, C, D; Class II,
Groups E, F, G; Divisions 1 & 2. (TA housing.) Includes cover o-ring for weathertight applications.
Not available with BG, BH or JH housings.
TB
Oversize stainless steel nameplate or separate stainless steel tag. Permanently attached to housing.
Stamped with customer-specied tagging information.
TT
Fungicidal varnish. Covers exterior and interior except working parts. VV
Epoxy coating. Exterior only. Polyamide epoxy with 316SS pigment. (200 hours-salt spray) YY
X is used as a sufx to the model number for special requirements not keyed elsewhere in the model number
by an X. Each X must be completely identied in the text of the order or inquiry. When more than one X
is required, use X followed by the number of such items. For example, X3 means three separate otherwise
unidentiable requirements.
X
*Consult factory for materials other than A105, A106B, 316/316L, or 304/304L.
Certicates C1 C2 C3 C4 C5 C6 C8 B1 B4 B5 B6 B7 A1 A2 A3 A4 A5 A6 A7 A8
Calibration

Hydrostatic
Pressure Test

Inspection Report
Compliance /
Conformance

Dielectric Test
Insulation
Resistance

Typical Material
of Wetted Parts

Test Certicates
12/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches
Agency Approval
The chart below shows authorized combinations of components so that the complete pressure
switch is approved, certied or listed by the cognizant agencies. Components or combinations of
them may acquire additional approval, certication or listing prior to revision of this catalog.
Contact the factory for the most current information.
UL Listed
CSA
Certied
ATEX
Approved
* Refer to Mini-Hermet Form 168 for special conditions for safe use.
For Hazardous Locations Class I, Groups A, B, C, D; Class II, Groups E, F, G; Divisions 1 & 2
Piston Housing
Switching
Element
Spring
Diaphragm
System
Pressure Port
Material and
Connection Size
Accessories
Options
5, 6, 9 AP, AS
AF, AG,
EF, EG,
JF, JG
2, 3, 4,
5, 45
U8
C1A
C2A
BB, NC, NN, PK,
PP, RR, TB, TT, VV,
YY
Note: UL Listed models are suitable for handling petroleum-based, ammable and combustable liquids and gases, air,
oxygen and water at fuid temperatures not exceeding 40C and ambient temperatures not exceeding 40C.
For Hazardous Locations Class I, Group A, B, C, D; Class II, Groups E, F, G; Divisions 1 & 2
Piston Housing
Switching
Element
Spring
Diaphragm
System
Pressure Port
Material and
Connection Size
Accessories
Options
5, 6, 9 AP, AS
AF, AG,
EF, EG,
JF, JG
2, 3, 4,
5, 45
U8
C1A
C2A
BB, HT, NC, PK,
PP, RR, TB, TT, VV,
YY
For Dual Seal Approval
Piston Housing
Switching
Element
Spring
Diaphragm
System
Pressure Port
Material and
Connection Size
Accessories
Options
1, 5, 6,
9, 56
AG, AH,
AP, AS
AF, AG,
EF, EG,
JF, JG
2, 3, 4,
5, 45, 316
M2, M4, N4,
U8, U9
C1A
C2A
DS Required
CV, NC, PP,
RR, TT, YY
For Flammable Atmospheres: Rating: EEx d IIC T5 or T6 per EN 50-014 & 018
Piston Housing
Switching
Element
Spring
Diaphragm
System
Pressure Port
Material and
Connection Size
Accessories
Options
5, 6, 9
BG, BH
AF, AG,
EF, EG,
JF, JG
2, 3, 4,
5, 45
U8, U9
All
BB, HB, HBME, PP,
RR, TT, VV, YY
1, 5, 6, 9
2, 3, 4,
5, 45
A4, M1, M2,
M4, M5, M7,
M8, N1, N3,
N4, N5, N6,
N7, N8, P1,
R1, S1, S2
W2, W4, W5,
W6, Y1
13/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Pressure Switch
A bi-stable electromechanical device that
actuates/de actuates one or more electrical
switching element(s) at a predetermined
discrete pressure/vacuum (Set Point) upon
rising or falling pressure/vacuum.
Adjustable Range
The span of pressure between upper and lower
limits within which the pressure switch can be
adjusted to actuate/deactuate. It is expressed
for increasing pressure.
Set Point
That discrete pressure at which the pressure
switch is adjusted to actuate/deactuate on
rising or falling pressure. It must fall within the
adjustable range and be called out as
increasing or decreasing pressure.
Dead Band
The difference in pressure between the
increasing Set Point and the decreasing Set
Point. It is expressed as typical, which is an
average with the increasing Set Point at mid
range for a pressure switch with the standard K
switching element. It is normally xed
(non-adjustable).
Overrange
The maximum input pressure that can be
continuously applied to the pressure switch
without causing permanent change of Set
Point, leakage or material failure.
Proof Pressure
The maximum input pressure that can be
continuously applied to the pressure switch
without causing leakage or catastrophic
material failure. Permanent change of Set
Points may occur, or the device may be
rendered inoperative.
Repeatability
The ability of a pressure switch to successively
operate at a Set Point that is approached from
a starting point in the same direction and
returns to the starting point over three
consecutive cycles to establish a pressure
prole. Repeatability on SOR switches will
be smaller than 1% of full scale per ISA/ANSI
S51.1.
SPDT Switching Element
Single-Pole, Double Throw (SPDT) has three
connections: C Common, NO Normally
Open and NC Normally Closed, which
allows the switching element to be electrically
connected to the circuit in either NO or NC
state.
DPDT Switching Element
DPDT is two synchronized SPDT switching
elements which actuate together at increasing
Set Point and deactuate together at
decreasing Set Point. Discrete SPDT switching
elements allow two independent circuits to be
switched; i.e., one AC and one DC.
The synchronization linkage is factory set, and is
not eld adjustable. Synchronization is
veried by connecting test lamps to the
switching elements and observing them go
On simultaneously at actuation and Off
simultaneously at deactuation.
Fire-Safe
The ability of a welded seal pressure sensor to
contain the process at elevated temperatures
up to 1200
o
F at the rated overrange pressure,
unsupported by the body of the pressure switch.
Hermetically Sealed
A welded steel capsule with glass-to-metal,
factory-sealed, electrical leads that isolates the
electrical switching element(s) from the
environment.
SOR recognizes that there is no industry convention with respect to terminology and denitions
pertinent to pressure switches. This glossary applies to SOR pressure with hermetically switching
element capsules.
Mini-Hermet
Pressure Switches
Glossary of Terms
14/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
*156.6
6.17
34.9
1.38
76.2
3.00
PROCESS
CONN SIZE
* LENGTH
1,5,6,9
* LENGTH
2,3
* LENGTH
56
** HEX
1,5,6,9,56
** HEX
2,3
1/4 NPTF SHOWN
14.0
ADD
0.55
18.3
ADD
0.72
28.7
1.13
28.7
1.13
1/2 NPTF
13.2
ADD
0.52
24.1
ADD
0.95
38.1
1.50
9/16 SAE SHOWN
14.0
ADD
0.55
N/A
28.7
1.13
3/4 NPTM
23.1
ADD
0.91
N/A N/A
Model Name: 0090119.ASSEM/18/2+
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE 1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
S BOAL
DATE
10 FEB 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 1/2/3/5/6/9 & 56
MINI-HERMET
EO NUMBER: 5090
SCALE: 0.88
DO NOT SCALE PRINT
DRAWING NUMBER REV
0090119 19
SHEET 1 OF 1
DWG SIZE
B
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
FACTORY SEALED LEADS
COLOR CODED & MARKED
457.2
18.00
MIN LENGTH
ELECT CONN
1/2 NPTM
WEATHERTIGHT
COVER SCREW
FLEXIBLE SEAL
RETAINER
PROCESS
CONNECTION
28.7
1.13
HEX
EXTERNAL GROUND
BG, BH, & JH HOUSING
** HEX
INSTALLATION
CLEARANCE MIN
Reset Form
Mini-Hermet
Pressure Switches
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certied drawings for a particular model number.
Notes
1. Dimensions on pages 14 and 15 are expressed as millimeters over inches (Linear = mm/in.).
2. Dimensions marked A-Length on housing dimension drawings vary with respect to process
connection size. The chart below lists A-Lengths with reference to piston number and process
connection size.
Dimensions
Process Connection Size
A-Length
Piston Number 6, 5, 9, 1 Piston Number 56
1/4 NPT(F) 156.6mm / 6.17 inch
174.9mm / 6.89 inch
1/2 NPT(F) 169.8mm / 6.69 inch
3/4 NPT(M) 179.7mm / 7.08 inch (outline not shown) N/A
Drawing 0090119
15/16
Form 456
sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Mini-Hermet
Pressure Switches Dimensions
Pipe Mounting Bracket - PK Junction Box with Terminal
Block - TB
Terminal Boxes
H Series
Parallel Mounting Perpendicular Mounting
*Dimension shown is approximate and based on a
5-thread engangement.
Dimensions Shown are for Reference
Only. Contact the Factory for Certifed
Dimension Drawings.
Linear = mm/in.
Approximate Weight
Component Designator Weight (lbs) (kgs)
Housing AG, AP, BG 1.5 [0.7]
Housing AH, AS, BH, JH 2.0 [1.0]
Junction Box TB
(Add to housing)
5
[2.25]
Pipe Mounting Kit PK
(Add to housing)
1.5
[0.7]
Terminal Box HB, HBME, HT
(Add to housing)
2.0
[1.0]
Drawing
0090300
Drawing
0091353
Drawing 0090763
16/16
Form 456 sorinc.com
913-888-2630 Registered Quality System to ISO 9001:2008
Registered Quality System to ISO 9001:2008 Form 456 (03.12) 2012 SOR Inc.
echOsonix


Level Transmitters
Temperature
Switches
P
r
e
s
s
u
r
e
Flow
Level
Level
Switches
Flow
Switches
Pressure
Switches
SOR

offers a full line of commercial-grade process instruments.


T
e
m
p
e
r
a
t
u
r
e
We Deliver Quality On Time
SOR Europe, Ltd.
Farren Court
Cowfold
West Sussex RH13 8BP
United Kingdom
Phone +44 (0) 1403 864000
Fax +44 (0) 1403 864040
SOR - China
Room 903, No. 10 Building
Wan Da Plaza
No. 93 Jian Guo Road
Chao Yang District
Beijing, China 100022
Phone +86 (10) 5820 8767
Fax +86 (10) 58 20 8770
SOR Inc.
14685 West 105th Street
Lenexa, Kansas 66215
Phone 913-888-2630
Toll Free 800-676-6794
Fax 913-888-0767
sorinc.com
Process Instrumentation
Form 168 (05.13) SOR Inc. 1/8
General Instructions
Design and
specifications are
subject to change
without notice.
For latest revision, go to
www.sorinc.com
Mini-Hermet Pressure Switches
with Hermetically Sealed
Electrical Switching Elements
Table of Contents
Installation .......................................2
Process Connection ............................2
Electrical Connection ...........................3
SIL Installation ..................................4
Calibration .......................................4
Special Conditions ..............................5
Dimensions ......................................5
General Information for ATEX .................6
ATEX Marking Materials .......................7
Declaration of Conformity .....................8
Registered Quality System to ISO 9001
These instructions cover installation, process connection, electrical connection and
calibration of the SOR

Mini-Hermet explosion proof pressure switches.


The switching element is hermetically sealed in an explosion proof capsule
that is UL Listed and CSA Certified for hazardous locations Class I,
Groups A, B, C & D; Class II, Groups E, F & G; Divisions 1 & 2 and
SAA Approved for Ex s IIC T6 IP65 Class 1, Zone 1. When certain
options are ordered, the Pressure Switch may be ATEX Certified
EEx d IIC or UL Listed and CSA Certified Class I, Groups A, B, C & D;
Class II, Groups E, F & G; Divisions 1 & 2.
Static O-Ring Type (prefaced by 1, 5, 6, 9, 10 or 56)
Typical Model No. 6AG-EF3-N4-C1A
The static o-ring type pressure switch with optional wetted parts is
suitable for a wide variety of process applications. This type is not
recommended for high-pressure fluid power applications where
high shock pressure and high cycle rates are expected. Use SOR
pivot seal type for fluid power applications.
Pivot Seal Type (prefaced by 2 or 3)
Typical Model No. 3AH-EF45-P1-C1A
The pivot seal type pressure switch is generally suitable for fluid power hydraulic
applications where high shock pressures and high cycle rates are expected and where
only normally industrial clean hydraulic fluid is used. Use static o-ring type for other
process applications.
NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative
in your area for a return authorization number (RMA). This product should only be installed by
trained and competent personnel.
2/8 Form 168 (05.13) SOR Inc.
Installation
When rigid process piping or electrical conduit is not available, the pressure switch
should be clamped in the area between the set point adjustment protrusion and the
pressure port to a suitable component in the application.
Process Connection
Use two wrenches when connecting to the process pipe or tube fitting.

1. A 1-1/8 inch open-end wrench to HOLD the pressure port
2. The other wrench to TURN the process pipe or tube fitting
It is important that NO bending or torsional forces
are imposed on this pressure switch when making the
PROCESS and ELECTRICAL connections.
The hermetically sealed switch element capsule has been
precisely positioned and locked during manufacture.
Excessive force could overcome the lock and cause
movement which will adversely affect proper operation or
render the pressure switch inoperative.
Should movement occur, factory calibration must be
performed in order to restore normal operation.
DO NOT USE
A pipe wrench or strap wrench
on the round body while
installing the PROCESS or
ELECTRICAL conduit connection.
pipe
or
tube
Form 168 (05.13) SOR Inc. 3/8
Electrical Wiring and Connection
WI RI NG
Ensure that wiring conforms to all applicable local and national electrical codes and
install unit(s) according to relevant national and local safety codes.
The electrical switch element capsule assembly contains UL Listed and CSA
Certified factory-sealed leads. A conduit seal is not required to preserve explosion
proof integrity. Electrical leads are marked NC (Normally Closed), NO (Normally Open)
and C (Common). Electrical switch elements are snap-action and are either 1-SPDT or
2-SPDT (DPDT) set to actuate simultaneously.
2-SPDT
(DPDT)
Pressure
Blue (C1)
Black (NO)
Red (NC)
Green (GND)
Wiring Lead
Code Colors
Blue (C1)
Black (NO)
Red (NC)
Yellow (C2)
Brown (NO2)
Orange (NC2)
SPDT
Pressure
NO1 NO2 Green (GND)
CONNECTI ON
Use two wrenches when connecting to the electrical conduit or conduit fitting.

1. One wrench to TURN the electrical conduit.
2. A 1-1/8 inch open-end wrench to HOLD the switch
element capsule.
TACK WELDS
Do NOT put stress on
tack welds OR
colored lacquer
at the switch
element capsule
when connecting the
electrical conduit.
COLORED LACQUER
c
o
n
d
u
i
t

4/8 Form 168 (05.13) SOR Inc.
Calibration
Mini-Hermet Pressure Switches are field adjustable across the entire cataloged range
for a particular piston/spring combination. Field adjustable models have a set point
adjustment under the removable weathertight cover screw.
It is not necessary to disconnect the electrical power, since the electrical switching
element is inside the hermetically sealed explosion proof capsule, thereby maintaining
explosion proof integrity.
Remove knurled weathertight cover screw.
Use 1/8 inch hex (Allen type) wrench to turn adjusting screw to achieve desired
set point. Turn adjusting screw clockwise (in) to increase set point; turn
adjusting screw counterclockwise (out) to decrease set point. Use an external
pressure measuring device to accurately calibrate set points.
Do not unthread the adjusting screw more than two threads below the fush
point of housing as calibration could be adversely affected.
After the set point has been calibrated, replace the cover screw tightly to ensure
the weathertight integrity of the device.
SOR discourages field modifications, change-out of wetted parts or repair. It is
recommended that products be returned to SOR Inc. for inspection and necessary
repair work. Any field work should be performed by a qualified instrument technician
following formal SOR procedures.
NOTE: UL Listed models are suitable for handling petroleum-based, fammable and
combustible liquids and gases, air, oxygen and water at fuid temperatures not exceeding
40C and designed for ambient temperatures not exceeding 75C.
Units in hazardous locations - Prior to removal from service, make sure that
the work area is declassifed. Failure to do so could result in severe personal
injury or substantial property damage.
Safety Integrity Level (SIL) Installation Requirements
The SOR pressure switches have been evaluated as Type-A safety related hardware.
To meet the necessary installation requirements for the SIL system, the following
information must be utilized:
Proof Test Interval shall be one year.
Units may only be installed for use in Low Demand Mode.
Products have a HFT (Hardware Fault Tolerance) of 0, and were evaluated in a
1oo1 (one out of one) configuration.
Form 1538 (03.12) 2012 SOR Inc.
Form 168 (05.13) SOR Inc. 5/8
Dimensions are for
reference only.
Contact the factory
for certified drawings
for a particular model
number.
Special Conditions for Safe Use ATEX, TIIS units
Dimensions
Linear = mm/inches
Drawing 0090119
The permanently attached cables are to be suitably terminated and protected
from impact.
To minimize the risk of electrostatic discharge, clean only with a damp cloth.
6/8 Form 168 (05.13) SOR Inc.
General Information for ATEX Certifed Models
R
e
g
u
l
a
r

P
r
e
s
s
u
r
e
Piston-Spring
Designators
Adjustable Range Overrange Proof
psi bar psi bar psi bar
6 - 2 7 to 30 0.5 to 2
1500 100 2500 170
6 - 3 12 to 100 0.8 to 7
6 - 5 20 to 180 1.4 to 12
6 - 45 25 to 275 1.7 to 19
5 - 3 25 to 240 1.7 to 16
5 - 5 35 to 375 2.4 to 26
5 - 45 45 to 550 3.1 to 38
9 - 4 100 to 500 7 to 35
2500 170 6000 410 9 - 5 200 to 1000 14 to 70
9 - 45 200 to 1750 14 to 120
1 - 45 500 to 4000 35 to 275 5000 340 6000 410
V
a
c
u
u
m
Piston-Spring
Adjustable Range
Vacuum-0-Pressure
Overrange Proof
in. Hg bar psi bar psi bar
56 - 216 30 - 0 - 20 1.0 - 0 - 0.7
1500 100 2500 170
56 - 316 30 - 0 - 160 1.0 - 0 - 5.4
P
i
v
o
t

S
e
a
l
Piston-Spring
Designators
Adjustable Range Overrange Pressure Proof Pressure
psi bar psi bar psi bar
2 - 3 100 to 1900 7 to 130
8000 550 10,000 700
2 - 5 500 to 3000 35 to 210
3 - 45
1000 to
7000
70 to 480
Designator
AC Rating DC Rating (Resistive)
Volts Amps Volts Amps Volts Amps
AF & AG 250 11 125 0.5 30 5
EF & EG 250 5 - - - -
JF & JG 125 1 - - 30 1
Form 168 (05.13) SOR Inc. 7/8
ATEX Marking Materials
Serial Number
(First Two Numbers Indicate
Year of Manufacture)
Manufacturers
Registered Trademark
ATEX Listing
Information
Thread Form
Information
Product Model
Identification
Drawing 8304108
8/8 Form 168 (05.13) SOR Inc.
Declaration of Conformity
For ATEX Certifed Models
Form 1382 (08.12) 2012 SOR Inc. (Printed in USA)
Product
Manufacturer
Date of Issue
We declare that the above
products conform to
the following specications
and directives
Carries the marking
Reference document

ATEX Notied Body
Persons responsible
A Mini Hermet Pressure or Temperature Switch
SOR Inc.
14685 West 105
th
Street
Lenexa, Kansas 66215-2003
United States of America

July 25, 2012
ATEX Directive (94/9/EC) Equipment Intended for use
in Potentially Explosive Atmospheres
EN 60079-0:2009
EN 60079-1:2007
II 2 G Ex d IIC T6 Gb

(Tamb = -40C to +65C) or T5 (Tamb = -40C to +80C)

EC-Type Examination Certicate
Baseefa03ATEX0582X
Issued October 31, 2003
Baseefa Ltd. (Notied Body No. 1180)
Rockhead Business Park, Staden Lane,
Buxton, Derbyshire SK17 9RZ
United Kingdom
Baseefa Customer Reference No. 1021
John J. Fortino (VP of Engineering)
John J. Fortino

14685 West 105th Street, Lenexa, KS 66215-2003
9138882630 8006?66?94 SA 9138880?6? FAX
Engineered to Order with Off-the-Shelf Speed
EC Declaration
of Conformity
14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 USA Fax 913-888-0767
Printed in USA www.sorinc.com

S-ar putea să vă placă și