Documente Academic
Documente Profesional
Documente Cultură
REV. DATE BY
PREAMBLE :
This Design Document represents Design of RC Column with 4 Sided equally Distrubuted R/f with Provisions of IS 456 : 2000
DESIGN DATA :
Factored Axial Load = Pu = Factored Moment about Major Axis = Mux = Factored Moment about Minor Axis = Muy =
PROPERTIES OF SECTION :
60 T 1 T-m 1 T-m
B = Width of Column i.e Minor Axis Size = D = Depth of Column i.e Major Axis Size = Lx = Unsupported Length about Major Axis = Ly = Unsupported Length about Minor Axis =
MATERIAL SPECIFICATION :
0.45 0.23 2 2
m m m m
GO TO SUMMARY
d'
D= 2000
MAJOR AXIS
D = 230
Y
B = 450 NOTE : R/F SHOWN IS INDICATIVE ONLY
2OF39 HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 4 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Lx = Unsupported Length about Major Axis = lex = Effective Length about Major Axis = lex = Kx * Lx= ( 1.2 x 2 ) = Ly = Unsupported Length about Minor Axis = ley = Effective Length about Minor Axis = ley = Kx * Ly= ( 1.2 x 2 ) =
lx =Slenderness Ratio about Major Axis = lx = ( lex / D ) = ( 2.4 / 0.23 ) = 10.43478 Musx = Moment due to Slenderness about Major Axis Musx = ( Pu * D ) * [lex/D]2 = 0 T-m 2000 Musx is Zero, if ( lx ) is <= 12
lx =Slenderness Ratio about Minor Axis = ly = ( ley / B ) = ( 2.4 / 0.45 ) = 5.33 Musy = Moment due to Slenderness about Minor Axis Musy = ( Pu * B ) * [ley/B]2 = 0 T-m 2000 Musy is Zero, if ( ly ) is <= 12
Minimum Eccentricity about Major Axis ( emin-x) = emin-x = ( Lx / 500 ) + ( D/ 30 ) = Or 0.02m whichever is greater
0.020 m
Minimum Eccentricity about Minor Axis ( emin-y) = emin-y = ( Ly / 500 ) + ( B/ 30 ) = Or 0.02m whichever is greater
0.020 m
Moment due to minimum Eccentricity about Major Axis = M ecc-x = Pu * emin-x = 1.200 T-m Moment due to minimum Eccentricity about Minor Axis = M ecc-y = Pu * emin-y = 1.200 T-m
DESIGN FACTORED FORCES :
60 T
Factored Moment about Major Axis = Mux = Mux = [ ( Mux(i) OR Mecc-x ) + Musx ] = 1.2 T-m ( Note := Musx shall be added only if Slenderness ratio is greater than 12 ) Factored Moment about Minor Axis = Muy = Muy = [ ( Muy(i) OR Mecc-y ) + Musy ] = 1.20 T-m ( Note := Musy shall be added only if Slenderness ratio is greater than 12 )
3OF39 HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 4 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Reinforcement to be distributed equally on FOUR SIDES . Adopt Bar Combination = Total Area of Steel As( Total ) = Corresponding Percentage of Steel = pt % = 4 - 16 # 804 mm2 0.78 %
Bars Contribution in Major Axis = Percentage of Steel about Major Axis = pt % = Area of Steel = Ast = pt * B * D = pt / fck = ( 0.78 / 20 ) =
Pu / fck * B * D = ( 600000 / 20 x 450 x 230 ) = Mux1 / fck * B * D2 = ( Mux1 = 0.05 x 20 x 450 x 230 ^2 ) = 0.290 0.05 2.38 T-m
Bars Contribution in Minor Axis = Percentage of Steel about Minor Axis = pt % = Area of Steel = Ast = pt * B * D = pt / fck = ( 0.78 / 20 ) =
4 - 16 # 0.78 %
2 804 mm
Pu / fck * B * D = ( 600000 / 20 x 450 x 230 ) = Muy1 / fck * D * B2 = ( Muy1 = 0.05 x 20 x 230 x 450 ^2 ) = 0.290 0.05 4.6575 T-m
4OF39 HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 4 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Mux Mux1
Muy Muy1
1.0
where, Mux = Factored Moment about Major Axis due to Design Loads = Mux = 1.2 T-m Mux1 = Maximum Uniaxial Bending Moment Capacity about major Axis for an Axial Load of Pu Mux1 = 2.38 T-m Muy = Factored Moment about Minor Axis due to Design Loads = Muy = 1.20 T-m Muy1 = Maximum Uniaxial Bending Moment Capacity about minor Axis for an Axial Load of Pu Muy1 = 4.6575 T-m an is related to Pu / Puz where, Puz = 0.45 fck * Ac + 0.75 fy * Asc Puz = ( 0.45 x 20 x ( 450 x 230 - 804 ) + 0.75 x 415 x 804 ) \ Puz = 117.45 T Pu = Puz 0.511 \ an = 1.52 an = 1.0, if ( Pu / Puz ) <= 0.2 an = 2.0, if ( Pu / Puz ) >= 0.8
1.52
1.52
Mux Mux1
Muy = Muy1
0.353
0.128
0.481
HENCE ASSUMED R/F IS ADEQUATE
TRANSVER R/F :
8 mm Use Diameter of Transverse R/f = The Pitch of Tranverse R/f shall be not more than the least of following. 1. Least Lateral dimension of column = 230 mm 2. 16 x Smallest Dia of Longitudinal R/f = 256 mm 3. Minimum 300 mm 300 mm Provide 8 # with 225 c/c as Transverse R/f
5OF39 HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 4 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
4 - 16 # 8 # @ 225 c/c 40 mm
Y
MINOR AXIS
d'
D= #REF!
MAJOR AXIS
D = 230
Y
B = 450
HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 2 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
PREAMBLE :
This Design Document represents Design of RC Column with 2 Sided equally Distrubuted R/f with Provisions of IS 456 : 2000
DESIGN DATA
Factored Axial Load = Pu = Factored Moment about Major Axis = Mux = Factored Moment about Minor Axis = Muy =
PROPERTIES OF SECTION :
B = Width of Column i.e Minor Axis Size = D = Depth of Column i.e Major Axis Size = Lx = Unsupported Length about Major Axis = Ly = Unsupported Length about Minor Axis =
MATERIAL SPECIFICATION :
m m m m
GO TO SUMMARY
MAJOR AXIS
D = 525
d'
HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 2 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Lx = Unsupported Length about Major Axis = lex = Effective Length about Major Axis = lex = Kx * Lx= ( 1 x 4.2 ) = Ly = Unsupported Length about Minor Axis = ley = Effective Length about Minor Axis = ley = Kx * Ly= ( 1 x 4.2 ) = lx = Slenderness Ratio about Major Axis = lx = ( lex / D ) = ( 5.04 / 0.525 ) =
9.6
Musx = Moment due to Slenderness about Major Axis Musx = ( Pu * D ) * [lex/D]2 = 2000 ly = Slenderness Ratio about Minor Axis = ly = ( ley / B ) = ( 5.04 / 0.23 ) =
0 T-m
Musy = Moment due to Slenderness about Minor Axis Musy = ( Pu * B ) * [ley/B]2 = 0.3699798 T-m 2000 Musy is Zero, if ( ly ) is <= 12
Minimum Eccentricity about Major Axis ( emin-x) = emin-x = ( Lx / 500 ) + ( D/ 30 ) = Or 0.02m whichever is greater
0.026 m
Minimum Eccentricity about Minor Axis ( emin-y) = emin-y = ( Ly / 500 ) + ( B/ 30 ) = Or 0.02m whichever is greater
0.020 m
Moment due to minimum Eccentricity about Major Axis = M ecc-x = Pu * emin-x = 0.174 T-m Moment due to minimum Eccentricity about Minor Axis = M ecc-y = Pu * emin-y = 0.134 T-m
DESIGN FACTORED FORCES :
6.7 T
Factored Moment about Major Axis = Mux = Mux = [ ( Mux(i) OR Mecc-x ) + Musx ] = 17.12 T-m ( Note := Musx shall be added only if Slenderness ratio is greater than 12 ) Factored Moment about Minor Axis = Muy = Muy = [ ( Muy(i) OR Mecc-y ) + Musy ] = 0.65 T-m ( Note := Musy shall be added only if Slenderness ratio is greater than 12 )
HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 2 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Percentage of Steel about Major Axis= pt % = Area of Steel = Ast = pt * B * D = Respective Bar Combination about Major Axis = pt / fck = d' = d' / D = ( 75 / 525 ) = ( 1.5 / 20 ) =
Pu / fck * B * D = ( 67000 / 20 x 230 x 525 ) = Mux1 / fck * B * D2 = ( Mux1 = 0.15 x 20 x 230 x 525 ^2 ) =
UNIAXIAL CAPACITY ABOUT MINOR AXIS = MUY1 =
Percentage of Steel about Minor Axis= pt % = Area of Steel = Ast = pt * B * D = Respective Bar Combination about Minor Axis = pt / fck = d' = d' / B = ( 50 / 230 ) = ( 0.8 / 20 ) =
0.8 %
2 966 mm
Pu / fck * B * D = ( 67000 / 20 x 230 x 525 ) = Muy1 / fck * D * B2 = ( Muy1 = 0.12 x 20 x 525 x 230 ^2 ) = 0.028 0.12 6.67 T-m
HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 2 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Mux Mux1
Muy Muy1
1.0
where, Mux = Factored Moment about Major Axis due to Design Loads = Mux = 17.12 T-m Mux1 = Maximum Uniaxial Bending Moment Capacity about major axi for an Axial Load of Pu Mux1 = 19.02 T-m Muy = Factored Moment about Minor Axis due to Design Loads = Muy = 0.65 T-m Muy1 = Maximum Uniaxial Bending Moment Capacity about minor Axis for an Axial Load of Pu Muy1 = 6.6654 T-m an is related to Pu / Puz where, Puz = 0.45 fck * Ac + 0.75 fy * Asc Puz = ( 0.45 x 20 x ( 230 x 525 - ) + 0.75 x 415 x ) \ Puz = 108.68 T Pu = Puz 0.062 \ an = 1.00 an = 1.0, if ( Pu / Puz ) <= 0.2 an = 2.0, if ( Pu / Puz ) >= 0.8
1.00
1.00
Mux Mux1
Muy = Muy1
0.900
0.098
0.998
HENCE ASSUMED R/F IS ADEQUATE
TRANSVER R/F :
8 mm Use Diameter of Transverse R/f = The Pitch of Tranverse R/f shall be not more than the least of following. 1. Least Lateral Dimension of Column = 230 mm 2. 16 x Smallest Dia of Longitudinal R/f = 320 mm 3. Minimum 300 mm 300 mm Provide 8 # with 225 c/c as Transverse R/f
HINDUSTAN CONSTRUCTION CO. LTD. MUMBAI. Subject : DESIGN OF RC COLUMN Details : 2 Sided Equally Distributed R/F
SH. NO.
REV. DATE BY
Main R/f about Major Axis= Main R/f about Minor Axis= Links = Eff. Cover =
6 - 20 # 10 - 12 # 8 # @ 225 c/c 75 mm
Y
MINOR AXIS
d'
MAJOR AXIS
D = 525
d'
Y
B = 230
CTIVE LENGTH
NOTE : l is Unsupported Length of Compression Member DEGREE OF END RESTAINST EFFECTIVELY HELD IN POSITION AND RESTRAINED AGAINST ROTATION IN BOTH ENDS SYMBOL THEORITICAL
0.5l
EFFECTIVELY HELD IN POSITION AT BOTH ENDS, RESTRAINED AGAINST ROTATION IN ONE END
0.7l
EFFECTIVELY HELD IN POSITION AT BOTH ENDS, BUT NOT RESTRAINED AGAINST ROTATION
1.00l
EFFECTIVELY HELD IN POSITION AND RESTRAINED AGAINST ROTATION AT ONE END, AND AT THE OTHER RESTRAINED AGAINST ROTATION BUT NOT HELD IN POSITION
1.00l
EFFECTIVELY HELD IN POSITION AND RESTRAINED AGAINST ROTATION AT ONE END, AND AT THE OTHER PARTIALLLY RESTRAINED AGAINST ROTATION BUT NOT HELD IN POSITION EFFECTIVELY HELD IN POSITION AT ONE ENDBUT NOT RESTAINED AGAINST ROTATION, AND AT THE OTHER END RESTRAINED AGAINST ROTATION BUT NOT HELD IN POSITION EFFECTIVELY HELD IN POSITION AND RESTAINED AGAINST ROTATION AT ONE END BUTNOT HELD IN POSITION NOR RESTAINED AGAINST ROTATION AT THE OTHER END
---
2.00l
2.00l
EFFECTIVELY HELD IN POSITION AND RESTAINED AGAINST ROTATION AT ONE END BUTNOT HELD IN POSITION NOR RESTAINED AGAINST ROTATION AT THE OTHER END
RECOMMENDED
0.65l
0.80l
1.00l
1.20l
1.50l
2.00l
2.00l