RPW/BPROS/ECOCPL13/eng/WIND/01.13/FR/7861 ALSTOM 2013. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or tness for any particular purpose. Reproduction, use or disclosure to third parties, without prior express written authority, is strictly prohibited.
POWER
POWEROF3 advantages
increase the annual energy production of the wind farm : capacity factor of a wind farm can be increased by up to20% reduce the total investment cost when compared with traditional development approaches : BOP (Balance of Plant) cost can be reduced by 15% by minimizing number of turbine positions, land utilization and hence infrastructure costs common spare parts, standardized operation and maintenance procedures for the whole site thanks to product platforming lower cost of energy in a wide range of wind projects
Optimised operation and maintenance Modular approach Alstoms full range of services capabilities can provide everything from spare parts, repair, and on-site eld services, up to and including long-term O&M solutions. A modular approach covering manpower and materials for both corrective and preventive maintenance tasks means that customers can select the optimal combination of services to meet their specic needs.
Alstoms SCADA : WindAccess Based on 30 years of turbine maintenance experience and the latest developments in industrial communications, Alstoms Supervisory Control And Data Acquisition (SCADA) system lies at the heart of our enhanced operation and maintenance strategy. WindAccess is a web-based tool, which provides remote access to wind turbine data such as generated power, rotor rpm, electrical data, temperature of main components, mechanical sensors status, wind conditions and wind turbine status. Besides turbine data, it integrates wind farm masts and substation equipment and is compatible with most monitoring and control systems encountered in the energy business. The system allows remote monitoring and distributed control, thus owners can benet fully from the support of Alstom wind farm experts. By using Alstoms SCADA, the performance of an individual wind turbine or the whole wind farm can be studied and optimised in real time. Furthermore, the remotely collected data can be used to establish benchmarks and identify irregularities allowing timely intervention to avoid unplanned outages or secondary damage.
Specications
OPERATING DATA Wind turbine class (IEC) Rated power Cut-in wind speed Rated wind speed Cut-out wind speed (avg. 10 min) Instant cut-out wind speed (3s) ROTOR Rotor diameter Swept area Rotor yaw Number of blades Blade lenght Speed range GEARBOX Type Cooling system Lubrication system GENERATOR Type of generator Rated power Frequency Stator rated voltage Cooling ConVerter Type Cooling Grid code compLiance Designed for high demanding grid codes Fault Ride Through Reactive/active current injection Voltage range Frequency range Power factor range Zero voltage ride through Power recovery TOWER Standard hub heights ENVIRONMENTAL SPECIFICATIONS Ambient operational temperature Standstill temperature range Lightning protection IEC-61024 OPTIONS Monitoring Dynamic power regulation Noise reduction Cold climate kit Hot desert kit
ECO 100
IA 3.0 MW 12.0 m/s
ECO 110
IS-IIA 3.0 MW 3 m/s 11.5 m/s 25 m/s 34 m/s
ECO 122
IIB-IIIA 2.7 MW 10.0 m/s
100 m 7980 m2
122 m 11 689 m2
53.2 m 7.7 - 13.6 r.p.m. 3-stage planetary/helical active, cooler with forced ventilation forced oil lubrication asynchronous DFIG 3150 kW 50/60 Hz 1000 V water-air back-to-back IGBT water Yes Yes Yes 0.9-1.1 -7% to +5%
With over thirty years of experience in wind power, Alstom provides global energy solutions: from wind turbine design and supply to wind farm development, construction, and operation and maintenance services. The company offers onshore and offshore wind turbines ranging from 1.67MW to 6MW, providing solutions for all types of geographical locations and weather conditions. As part of its R&D activities, Alstom has developed the Haliade 150-6MW, the rst new generation offshore wind turbine. All Alstom wind turbines feature the ALSTOM PURE TORQUE concept, a unique rotor support design that protects the drive train from deection loads to ensure higher reliability. To date, Alstom has installed or is installing more than 2,500 wind turbines in over 150 wind farms with a total capacity of nearly 3,800 MW. For more information contact your Alstom representative:
Europe, Middle-East and Africa Alstom Roc Boronat, 78 08005 Barcelona Spain Phone: +34 932 257 600 Fax: +34 932 210 939 France Alstom 4, avenue Andr Malraux 92309 Levallois-Perret France Phone: +33 1 41 49 2000 Fax: +33 1 41 49 24 85 North America Alstom 100 Gateway Centre Parkway Richmond, VA 23235 USA Phone: +1 804 763 7676 Fax: +1 804 763 7675
0.87
0.85
75 m, 90 m, 100 m
75 m, 90 m, 100 m
-10C to + 40C -20C to + 50C Level 1 SCADA-type system with remote access Active and reactive power Congurable by date, time & wind speed/direction Operating to -30 C, Standstill to -40 C Operating up to +45C
www.alstom.com/power
RPW/BPROS/ECOCPL13/eng/WIND/01.13/FR/7861 ALSTOM 2013. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or tness for any particular purpose. Reproduction, use or disclosure to third parties, without prior express written authority, is strictly prohibited.
POWER