Sunteți pe pagina 1din 22

INSTALAO BASE TESTE AUTOSERVIO 1-Instalao usando emulador de impressora fiscal.

O PDV DE TESTES DEVE OBRIGATORIAMENTE ESTAR CADASTRADO EM UM BANCO DE DADOS DE TESTES. CASO ESTEJA EM PRODUO, CUPONS E OPERAES EFETUADAS NO MESMO SERO ENCAMINHADOS PARA SINTEGRA, SPED, NOTA FISCAL PAULISTA, NOTA FISCAL ELETRNICA, LIVROS FISCAIS, RELATRIOS DE VENDA, PLANO DE VO E ASSIM POR DIANTE. O CAIXA DE TESTES DEVE SER INSTALADO NO SISTEMA OPERACIONAL WINDOWS XP PROFESSIONAL. OUTROS SISTEMAS NO FORAM TESTADOS. Passo 1 SIMULADOR PORTA COM COM0COM-2.2.0.0-i-386 Aps criar a base local, necessrio criar o ambiente do autoservio no banco de testes. Ser necessrio criar o usurio Caixa. Use o seguinte script: create user caixa identified by caixa default tablespace ts_dados temporary tablespace temp; grant connect,resource to caixa; grant create table, create synonym, create sequence, create view to caixa; grant create database link to caixa; alter user caixa quota unlimited on ts_dados; alter user caixa quota unlimited on ts_indice; alter user caixa quota 0m on system; Feito isso, importe o dmp do usurio caixa. Acesse o cmd.

O comando : imp system/local fromuser=caixa touser=caixa file=caixa.dmp Caso a senha do usurio system no seja local, informe a senha correta. Salve o dmp no diretrio C:\.

Primeiramente, verifique quantas portas seriais (COM) existem na mquina e se as mesmas esto instaladas corretamente. Uma porta COM com defeito pode interferir no funcionamento de outras portas e mesmo em portas virtuais. necessrio um par de portas COM para uso de emulador de impressora fiscal. Feita a verificao, instale o simulador de portas seriais com0com.

Clique em Setup.exe.

Clique em Next.

Aceite a licena.

Clique em I Agree. Desmarque a opo CNCA<>CNB0.

Clique em Next.

Clique em Install. Clique em Next para finalizar a instalao.

Clique em Launch Setup Command Prompt.

Agora sera necessrio digitar o comando para instalar a porta serial. Conforme citado anteriormente, necessrio um par de portas. Exemplo: COM1 e COM2, COM2 e COM4. OBS: o emulador da impressora fiscal consegue comunicao at a porta COM4, ento no devem ser criados pares como COM5 e COM6, COM10 e COM12, etc.

O comando install portname=COM4 portname=COM5. (exemplo)

Sero solicitados automaticamente os instaladores de portas seriais do Windows XP.

Marque No, no agora para procura do driver via Windows Update e clique em Avanar.

Marque a opo Instalar o software automaticamente (recomendvel) e clique em Avanar.

Clique em Concluir. Essas telas so para a instalao das duas portas seriais.

Com isso, a instalao das portas seriais esto concludas.

Passo 2 EMULADOR DE IMPRESSORA FISCAL ITAUTEC FISCNET. Descompacte o arquivo Simulador ZPM 1.10.zip para o C:\ do PDV. Ser criada o diretrio C:\ Simulador ZPM 1.10. Dentro deste diretrio, clique duas vezes sobre o executvel Logg2.exe.

No topo do aplicativo, observe que h a possibilidade de selecionar a porta serial da impressora fiscal. Marque a opo (devido ao exemplo, COM4) e marque o boto ao lado que se assemelha a uma ligao. Utilize o aplicativo ECFTeste.exe para testes com o emulador antes de executar a rotina diretamente.

No ECFTeste, marque o modelo da impressora fiscal como FiscNET e clique em Ativar.

Acesse o menu Variveis, opo Equipamento e clique em Num Srie.

O nmero de srie do emulador 999999999. Feito isso, acesse a rotina PCSIS2044 e crie o caixa de teste.

Deixe a verso do emulador da Itautec como Nulo, sem marcar nenhum modelo. Clique em Alterar Db.Link para criar a comunicao do servidor para o caixa.

Informe o ip ou nome do host do caixa, usurio Caixa e senha Caixa.

Acesse a rotina PCSIS2001 e agende as cargas para o caixa.

No caixa, clique em Desativar no ECFTeste e execute a rotina PCAUX2075.

A rotina ir procurar pela impressora nas portas COM existentes at encontrar. Caso no encontre, ser exibida mensagem com a informao de que a impressora no est conectada.

Criar o diretrio do Auto Servio. No diretrio C:\WinThor\Prod\Mod-020, salve as dlls citadas abaixo: BemaFI32.dll InterfaceEpson.dll BemaFI32.ini InterfaceEpson.lib BemaMFD.dll libeay32.dll BemaMFD2.dll libseppemv.dll Borlndmm.dll libseppemv.ini Cheque.ini Licence.dll CliSiTef.ini MenuFiscal.dll CliSiTef32.dll Midas.dll CliSiTef32I.dll ModOperPC.dll CONVECF.dll Mrrima3eApi.dll CONVECF.lib MSJET35.dll CONVECF95.dll P05.dll CONVERSOR.dll PCAUX2075.ini Cripto.dll Pccrip.dll DAO350.dll PcScale.dll DAO350.lib Pcstrutils.dll Daruma32.dll Pcversao.dll Dbexpint.dll Qtintf.dll Dbexpora.dll Registra.bat DLL2EFC32.dll RFDZPMAPI.dll DLLG2.dll RFDZPMAPI.lib DLLG2.dll SC501GER.dll DLLG20.dll SC504.dll DllInscE32.dll sign_bema.dll ECF32M.dll SWECF.dll ecfcom32.dll Swmfd.dll EcfItaApi.dll SWMFD-connectc5.dll ECFZPMAPI.dll Tbudf.dll ECFZPMAPI.lib tec65_32.dll gds32.dll WinThor.ini INPOUT32.dll Zecf32.dll Acesse a rotina PCAUX2075. Faa os procedimentos padres para uso da rotina 2075. Pressione F2. O F2 funciona como uma atualizao de base de dados localmente (Oracle XE). Ela ir criar campos e tabelas novas (caso seja necessrio), porm comparando com a estrutura no servidor de produo.

Se a rotina 560 no for atualizada, ocorrero erros na atualizao do F2 da 2075.

Pressione F2. Ser exibida essa tela de confirmao de atualizao de estrutura de base de dados.

Clique em Sim.

Clique em Sim.

NO TENTE ACESSAR O MENU FISCAL. CASO PRECISE, SOLICITE AUXILIO DO SUPORTE DO MODULO 20.

MANUTENO DE CHECKOUTS Acesse o MENU DE MANUTENO DE CHECKOUT . Clicar no boto F-FUNO FISCAL DE CAIXA. Clicar na opo (F2) Atualizar estrutura de dados Em seguida execute a opo (F3)AJUSTAR NUMERADORES DAS VENDAS. Clicar em (F9) para criar o dblservidor. Acesse o MENU DE MANUTENO DE CHECKOUT

CD USURIO: Informar o cdigo do operador/ fiscal de caixa SENHA: Informar a senha desse usurio

Dblservidor

Informe o ip ou host da maquina, usurio do banco local e senha, depois informe se ser servidor de carga de tabelas ou servidor WinThor, o servidor que o caixa estar vinculado. A rotina PCAUX2075 faz a criao e atualizao de tabelas e campos, no banco de dados local (funciona como a rotina PCINFTAB nos caixas). Esse procedimento necessrio para que, o banco de dados de produo esteja coerente com o banco local. Cada mquina pode ter um comportamento diferente com esses aplicativos (simulador de portas, emulador de impressoras fiscais). Caso haja alguma dificuldade ou mensagens no apresentadas aqui, entre em contato com o fabricante. A homepage do simulador de portas http://com0com.sourceforge.net/. O fabricante do emulador de impressora fiscal a ITAUTEC, www.itautec.com.br.

2 Instalao para caixa de nota fiscal. Aps subir a base do banco de dados local, necessrio criar o usurio do caixa e subir o dmp. create user caixa identified by caixa default tablespace ts_dados temporary tablespace temp; grant connect,resource to caixa; grant create table, create synonym, create sequence, create view to caixa; grant create database link to caixa; alter user caixa quota unlimited on ts_dados; alter user caixa quota unlimited on ts_indice; alter user caixa quota 0m on system; Feito isso, importe o dmp do usurio caixa. Acesse o cmd.

O comando : imp system/local fromuser=caixa touser=caixa file=caixa.dmp Caso a senha do usurio system no seja local, informe a senha correta. Salve o dmp no diretrio C:\. Agora, acesse a rotina 2044 para a criao do caixa de nota fiscal.

No Tipo Impressora marque Nota Fiscal e no nmero de srie, informe 123. Clique em Alterar Db.Link para criar a comunicao do servidor para o caixa.

Informe o ip ou nome do host do caixa, usurio Caixa e senha Caixa.

Verifique o processo de criao do diretrio e inicializao da 2075 descrito acima, na instalao usando impressora fiscal ( a mesma coisa). Acesse a rotina 2075 e pressione CTRL + F.

Informe o nmero do caixa que de nota fiscal.

Pressione F2, faa a carga total e depois acesse o F5, depois Funes Fiscal de Caixa e atualize a base de dados local e crie o dblservidor.

S-ar putea să vă placă și