Sunteți pe pagina 1din 18

WinPISA

Setup and Programming of Smart Positioning Controller SPC-200

Setup

Create a New Project


Select File / New project Type in a File Name Confirm with <OK>

In the following Dialog type in a title and an optional comment; Confirm with <OK>

05.98 / PV-IIP /znk

Setup

Configuration of Hardware

Select the Hardware icon Right Mouse click the Hardware icon

At the following context menu ...

05.98 / PV-IIP /znk

Setup

Configuration of Hardware

Select - Insert object / - SPC 200 ...

05.98 / PV-IIP /znk

Setup

Configuration of SPC-200

With Online activated, you can upload the Controller configuration

For manual configuration, select an empty slot by clicking

05.98 / PV-IIP /znk

Setup

Open the drop down list and select the according unit

05.98 / PV-IIP /znk

Setup

Configuration of Axes

Select the Controller icon Right Mouse Click the Controller icon

On the following Context Menu ...

05.98 / PV-IIP /znk

Setup

Select - Insert object / - Positioning axis

05.98 / PV-IIP /znk

Setup

scroll down the list with the scroll bar

Select the cylinder by diameter and stroke range

05.98 / PV-IIP /znk

Setup

double click the Axis icon

05.98 / PV-IIP /znk

10

Setup

Axis Parameter
Designation for drive
stroke length

length of position sensor

05.98 / PV-IIP /znk

11

Setup

Application Parameter
tool load

software limit switches tolerance

05.98 / PV-IIP /znk

12

Setup

Create a Test Program

Right mouse click the Software Icon On the following context menu select Insert object ...

05.98 / PV-IIP /znk

13

Setup

Type in a title for the program Type in an optional comment

Confirm with <OK>

05.98 / PV-IIP /znk

14

Setup

Editing a Test Program

Type in a first test program: N001 G01 X50 FX50 N002 G01 X450 FX50 N003 M30

05.98 / PV-IIP /znk

15

Setup

Speed Buttons:

Syntax Check Compile Program Save Program and Close Window

The Status Bar gives Information about Speed Buttons


05.98 / PV-IIP /znk

16

Setup

Download the Project

Activate the Online Mode: Online / Online mode

Download the complete Project: Online / Download / Project

05.98 / PV-IIP /znk

17

Setup

Test the System

Check the input signals: ENABLE = 24 V STOP = 24 V Start the system with START = 0 ---> 1 Stop the system with STOP = 0V

(Input 9) (Input 7)

(Input 8)

NOTE: After first Project Download a 0/1 transition at ENABLE input is required !

05.98 / PV-IIP /znk