Sunteți pe pagina 1din 4

Art&ScienceofProtectiveRelayinginPowerSystem

CourseIntroduction:
The quality of Electric Power is an evergrowing concern today for both utility supplier and consumers. For that, all Transmission Lines Feeders, Motors, Busbars, ..) have to be adequately protected to avoid major system distur bances, which may cause system instability or damage to equipment if faults on the system are not cleared within speciedfaultclearingtimes. understanding of system faults and their detection, as well as their reliable safe isolation from the system. This

WhoShouldAttend?
The course curriculum is designed for Electric Power Engineers, Supervisors, Foreman and Senior Technicians ElectricPowerSystems. It is also intended for Consulting and Manufacturing Engineers as well as Engineers with Protective Relaying EquipmentSupplyCompanies.

system components (Generators, Transformers, involved in the Control, Operation, and Protection of

CourseOutlines
1.1 WhatisProtectiveRelaying?

Protection of the Power System requires an Module(01)ThePhilosophyofProtectiveRelaying 1.2 TheFunctionofProtectiveRelaying course presents comprehensive and systematic 1.3 PrimaryandBackupProtection descriptions of the concepts and principles of application 1.4 FundamentalPrincipleofProtectiveRelaying 1.5 PrimaryRelayingandBackup 1.6 1.7 ProtectionagainstotherAbnormalConditions FunctionalCharacteristicsofProtectiveRelay power system elements. Many utilities need this course that studies the relay characteristics during faults and weakprotectionpointsinelectricalpowersystems. presenting case studies occurred on the system. The course will be valuable to engineers and technicians just

and operation of protection schemes applied for various

Module(02)FundamentalRelayOperating
OperatingPrinciples TimeDelayanditsDefinitions RelaysandRelayTypes ThermalRelays,FrequencyRelay SingleQuantityRelayoftheElectromagnetic AttractionType. DirectionalRelaysoftheElectromagnetic AttractionType 2.2 2.3

In addition, the course enforces the concepts by 2.1

entering the system protection field and those seeking 2.4 a better understanding of the new stateoftheart of 2.5 protectiverelaying.

CourseObjectives
Thiscourseisdesignedtoreviewfortheparticipantsthe fundamental concepts of protective relaying and fault currentcalculationsusingsymmetricalcomponents. Also after they completed this course they will be gain morebenefitssuchas:
Knowing the fault reasons in Electrical Networks

2.6

Module(03)MeasuringTransformers(VT/CT)
3.1 3.2 CurrentTransformer 3.1.1 Design,Construction,andOperation 3.1.2 OpenCircuitedCurrentTransformer 3.1.3 ShortTimeFactor 3.1.4 AccuracylimitFactor 3.1.5 SpecificationofCurrentTransformer 3.1.6 SecondaryRating,WindingImpedance 3.1.7 CurrentTransformerTesting:Polarity/Ratio PotentialMeasuringDevices 3.2.1 ResidualConnection 3.2.2 CapacitorVoltageTransformer 3.2.3 RatioCheckTesting 3.2.4 PolarityCheckTesting

andtheireffectontheelectricalquantities.
Understanding main concepts of Protection

EquipmentanditsnecessityinelectricalSystem.
Howtomakerelaycoordinationformainandback

upprotectionrelaysonelectricalnetwork.
Howtofindthecauseofrelayoperationandverify

ifitiscorrect,fallsormaloperation.
Howtoprotectthepowersystemduetoabnormal

operatingconditions.

Art&ScienceofProtectiveRelayinginPowerSystem CourseOutlines(Contd)
Module(04)DifferentialProtection
4.1 4.2 4.3 4.4 4.5 4.6 ApplicationofDifferentialProtection PrinciplesofCirculatingCurrentDifferential DifficultiesinDifferentialProtection BiasedorPercentDifferentialRelays SettingofDifferentialRelays BalancedVoltageDifferentialProtection

Module(08)MotorProtection
8.1 8.2 8.3 8.4 8.5 AbnormalConditions SynchronousandAsynchronousMotors UnderVoltageProtection SinglePhasingProtection ShortCircuitProtection

Module(09)TransmissionLineProtection
9.1 9.2 OverCurrentProtection 9.1.1 NonDirectionalTimeGradedSystemof Feeder(Line)Protection Coordination 9.1.2 SettingofInverseOvercurrentRelaysfor 9.1.3 DirectionalTimeandCurrentGradedSystem 9.1.4 SettingofDirectionalOverCurrentRelays ofaRingMain 9.1.5 CurrentGradedSystem 9.1.6 InstantaneousandIDMTProtection 9.1.7 OverReachofInstantaneousOverCurrent 9.1.8 DefiniteTimeovercurrentProtectionofLines DistanceProtection 9.2.1 DistanceProtectionofH.VandE.H.V. 9.2.2 SteppedCharacteristic 9.2.3 SingleSteppedDistance,TimeCharacteristic 9.2.4 ThreeStepDistanceTimeCharacteristic 9.2.5 PowerSwings 9.2.6 CarrierAssistedDistanceProtection 9.2.7 CarrierTransfer 9.2.8 CarrierBlockingScheme (DirectionalComparisonMethod) 9.2.9 CarrierAcceleration 9.2.10DistanceSchemesforSinglePoleandTriple PoleAutoReclosing 9.2.11ConnectionofDistanceRelays 9.2.12ProtectionofParallelTransmissionLines

Module(05)TransformerProtection
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 ProtectionRequirements SafetyDeviceswithPowerTransformers BuchholzRelay(GasActuatedRelay)Limitationof BuchholzRelay BiasedDifferentialProtection,Percentage DifferentialProtectionofPowerTransfer ProblemsArisinginDifferentialProtection DifferentialofthreewindingTransformer DifferentialProtectionofAutoTransformer OvercurrentProtectionofPowerTransformer ExternalShortCircuit(ThoughFaults)

5.10 OverloadProtection

5.11ThermaloverHeatingProtection 5.12 OverFluxingProtection 5.13 ProtectionofGroundingTransformer

Module(06)GeneratorProtection
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 FaultsonGenerator DifferentialProtectionofGenerators TurntoTurnFaults Statoroverheating ReversePower RotorEarthFault FieldSuppression Overspeed ProtectionoflargeGeneratorsTransformerUnits

6.10 ProtectionofsmallStandbyGenerators

Module(10)BusbarProtection
10.1 DifferentialProtectionofBuses 10.2 Autoreclosure 10.3 InterlockOvercurrentProtection 10.4 BusbarSwitching(transfer)Arrangements

Module(07)DistributionSystemProtection
7.1 7.2 7.3 7.4 7.5 DiscriminationandCoordination SelectiveTrippingPlan,SelectiveTrippingTime SelectiveTrippingTimesontheLowVoltageSide SelectiveTrippingTimesontheHighVoltageSide ProtectiveDevicesforlowVoltageSide

Art&ScienceofProtectiveRelayinginPowerSystem CourseInstructor
Prof.AlmoatazY.Abdelaziz
ProfessorinElectricalEngineeringDepartment, FacultyofEngineering,AinShamsUniversity,Egypt

CourseFees
The amount of 3000 USD will be charged for the course. participant.

Send (3) delegates and get a 10% discount on the third

Prof.AlmoatazreceivedtheB.Sc.andM.Sc.degreesin ElectricalEngineeringfromAinShamsUniversity,Cairo, Egypt in 1985, 1990 respectively and the Ph. D. degree Englandin1996.HeiscurrentlyaProfessorofElectrical PowerEngineeringinAinShamsUniversity. electrical group in the General Directorate for Projects &Maintenance,KingSaud University,Riyadh,KSA from 2005to2007. Prof.Abdelaziz is expert in training elds, and has been doing many training courses and consultants for more

PaymentMethod
A confirmation letter will be sent upon your registration. Note that full payment must be made prior to the event.

Onlythosedelegateswhohavepaidinfullwillbeadmitted in Electrical Engineering from Brunel University, totheevent. All payments should be in favor of Apex FZLLC. Account detailsareasfollows: HSBCBankMiddleEastlimited, JebelAliBranch,Dubai,UAE A/C:035626472101

He was the head of consultant engineers of the

CancellationPolicy
If you are unable to attend the course you may send

asubstitutedelegate. than ten years in Egypt and Gulf area. He has supervised a large number of Ph. D. and. M. Sc.

research work in his research interest areas which Cancellation should be made 20 days prior to the course include the applications of articial intelligence to power systems and protection and new optimization techniquesinpowersystemsoperationandplanning. He has authored or coauthored more than 60 refereed journal and conference papers. Dr. Abdelaziz is a CourseCoordinator: Mobile:+971559326285 technical papers in several journals. He is also Email:lee@apexdubai.com a member in IET and the Egyptian SubCommittees of IECandCIGRE`. Prof.Abdelaziz hasbeen awardedAin Shams University Prizefordistinctresearchesin2002. He had a good experience in Technical Training in Electrical Field as a general and Protection Field as his specialty, he gave around 50 Industrial condensed courses for engineers, and technicians in Middle East Companies.
APEXFZLLC Block18,KnowledgeVillage Dubai,UAE,P.O.Box.502221

conduction. Failure to cancel within 10 days will be requiredtopaythecoursefeeinfullamount.

CONTACT DETAILS
LeeJoaquin

member of the editorial board and a reviewer of

+971 04 3622021 +971 04 3678636 info@apex-dubai.com www.apex-dubai.com