equipotential bonding
14 Fig. 9.13.1
bus station
Lightning and surge protection for SIMATIC Net PROFIBUS FMS and DP
hazardous area
equipotential bonding
Fig. 9.13.2
www.dehn.de
No. in Fig. Protection for ... 9.13.1 nd 9.13.2 Combined arresters Type 1 3-phase TN-C system 3-phase TN-S system 3-phase TT system
4
SPDs
Part No.
DEHNventil DV M TNC 255 DEHNventil DV M TNC 255 FM DEHNventil DV M TNS 255 DEHNventil DV M TNS 255 FM DEHNventil DV M TT 255 DEHNventil DV M TT 255 FM DEHNventil DV M TN 255 DEHNventil DV M TN 255 FM DEHNventil DV M TT 2P 255 DEHNventil DV M TT 2P 255 FM
951 300 951 305 951 400 951 405 951 310 951 315 951 200 951 205 951 110 951 115
Single-phase TN system Single-phase TT system Surge arresters Type 2 3-phase TN-C system 3-phase TN-S system 3-phase TT system
5
DEHNguard DG M TNC 275 DEHNguard DG M TNC 275 FM DEHNguard DG M TNS 275 DEHNguard DG M TNS 275 FM DEHNguard DG M TT 275 DEHNguard DG M TT 275 FM DEHNguard DG M TN 275 DEHNguard DG M TN 275 FM DEHNguard DG M TT 2P 275 DEHNguard DG M TT 2P 275 FM
952 300 952 305 952 400 952 405 952 310 952 315 952 200 952 205 952 110 952 115
Single-phase TN system Single-phase TT system Surge arresters Type 3 for 230 V supply
6
installations and systems, even in case of a direct lightning strike. If lightning equipotential bonding and the installation of surge protection systems are performed as carefully as the external lightning protection system, failures are reduced even at direct lightning strikes. The 230/400 V a.c. supply lines going from outside to the low-voltage main distribution board will be
protected by a DEHNventil modular, an SPD Type 1. This complete prewired unit is available for every low voltage system (TN-C, TN-S, TT) (Table 9.13.3). In addition to the operating state/fault indication which is not supplied by operating currents, this SPD Type 1 has a 3-pole terminal for remote signalling. Up to conductor lengths of 5 m between DEHNventil and terminal equipment, there is sufficient protection without additional protective devices.
www.dehn.de
Longer conductors require additional surge protective devices at terminal equipment, e.g. DEHNrail. Tables 9.13.1 and 9.13.2 show surge protective devices for bus lines and Table 9.13.3 lists the surge protective devices to be installed for the power supply.
Building without external lightning protection system If there is no external lightning protection system, the bus sharing units must be connected to surge protective devices. Here, the use of lightning current arresters on the power supply and data cables is not required. In Figure 9.13.1 and 9.13.2 the combined arrester Type 1 with No. (4) on the power line nor the lightning current arrester with No. (1) on the bus line are not required.
www.dehn.de