1. Obtain the efficiency vs. output characteristic of the given single-phase transformer without conducting a load test at 0.

8 pf lag. 2. Obtain the efficiency vs. output characteristic of the given single-phase transformer without conducting a load test at 0.8 pf lead. 3. Obtain the efficiency vs. output characteristic of the given single-phase transformer without conducting a load test at upf. 4. Obtain the regulation vs. load characteristic of the given single-phase transformer without conducting a load test at upf. 5. Obtain the regulation vs. load characteristic of the given single-phase transformer without conducting a load test at 0.8 pf lag. 6. Obtain the regulation vs. load characteristic of the given single-phase transformer without conducting a load test at 0.707 pf lead. 7. Obtain the regulation vs. power factor characteristic of the given single-phase transformer without conducting a load test at full load. 8. Obtain the regulation vs. power factor characteristic of the given single-phase transformer without conducting a load test at half of full load. 9. Obtain the regulation vs. power factor characteristic of the given single-phase transformer without conducting a load test at (3/4)th of full load. 10. Determine the maximum efficiency of the given single phase transformer and the load at which it occurs. 11. Obtain the circuit model of the given single-phase transformer referred to the LV side. 12. Obtain the circuit model of the given single-phase transformer referred to the HV side. 13. Determine the voltage across the load connected to the LV winding of the given single phase transformer when rated current is supplied at the rated voltage to its HV winding at 0.6 pf lag. 14. Determine the voltage across the load connected to the HV winding of the given single phase transformer when rated current is supplied at the rated voltage to its LV winding at 0.8 pf lead. 15. Determine the voltage across the load connected to the HV winding of the given single phase transformer when rated current is supplied at the rated voltage to its LV winding at upf. 16. Obtain the field control characteristic of the given dc shunt motor on no load at 100% rated value of armature applied voltage. 17. Obtain the field control characteristic of the given dc shunt motor on no load at 90% rated value of armature applied voltage. 18. Obtain the field control characteristic of the given dc shunt motor on no load at 80% rated value of armature applied voltage. 19. Obtain the armature control characteristic of the given dc shunt motor on no load at 100% rated value of excitation. 20. Obtain the armature control characteristic of the given dc shunt motor on no load at 90% rated value of excitation. 21. Obtain the armature control characteristic of the given dc shunt motor on no load at 80% rated value of excitation. 22. Determine the characteristic efficiency vs. output of the given dc shunt machine, when it is operated as a generator.

23. Determine the characteristic efficiency vs. output of the given dc shunt machine, when it is operated as a motor. 24. Determine the efficiency and line current of the given dc motor when it delivers the rated output. 25. Determine the efficiency and line current of the given dc motor when it delivers half the rated output. 26. Determine the efficiency and line current of the given dc motor acting as a generator when it takes the input of 1.5kW. 27. Determine the efficiency and line current of the given dc motor acting as a generator when it takes the input of 2.2kW. 28. Determine the torque vs. output characteristic of dc shunt motor. 29. Obtain the characteristic synchronous impedance vs. field current of the given three-phase synchronous generator. 30. Obtain the characteristic synchronous reactance vs. field current of the given three-phase synchronous generator. 31. Determine percentage regulation of the given 3-phase synchronous generator when it delivers rated load at 0.8 pf lag. 32. Determine percentage regulation of the given 3-phase synchronous generator when it delivers rated load at 0.8 pf lead. 33. Determine percentage regulation of the given 3-phase synchronous generator when it delivers rated load at upf. 34. Determine the critical resistance of the given dc shunt generator under no-load at rated speed. 35. Plot the open circuit characteristic of the given dc shunt generator at 90% of the load speed and determine the critical resistance of it at rated speed. 36. Plot the open circuit characteristic of the given dc shunt generator at 80% of the load speed and determine the critical resistance of it at rated speed. 37. Plot the open circuit characteristic of the given dc shunt generator at 70% of the load speed and determine the critical resistance of it at rated speed. 38. Determine the critical speed of the given dc shunt generator under no-load with a field current to produce rated voltage at the initial point. 39. Plot the induced emf vs. speed of the given dc shunt generator by setting the field current to produce 90% of the rated voltage at the initial point and determine the critical speed of it at rated voltage. 40. Plot the induced emf vs. speed of the given dc shunt generator by setting the field current to produce 80% of the rated voltage at the initial point and determine the critical speed of it at rated voltage. 41. Plot the induced emf vs. speed of the given dc shunt generator by setting the field current to produce 70% of the rated voltage at the initial point and determine the critical speed of it at rated voltage. 42. Obtain the external characteristic of the given dc shunt generator without conducting a load test.

43. Obtain the internal characteristic of the given dc shunt generator without conducting a load test. 44. Obtain the external characteristic of the given dc shunt generator by conducting a load test. 45. Obtain the internal characteristic of the given dc shunt generator by conducting a load test. 46. Conduct a suitable test on the given dc shunt generator and obtain the characteristic voltage drop due to armature reaction vs. armature control. 47. Conduct Sumpners test on the given pair of single phase transformers and obtain the efficiency vs output at 0.8 pf lag. 48. Conduct Sumpners test on the given pair of single phase transformers and obtain the efficiency vs output at 0.8 pf lead. 49. Conduct Sumpners test on the given pair of single phase transformers and obtain the efficiency vs output at upf. 50. Conduct Sumpners test on the given pair of single phase transformers and obtain the regulation vs output at upf. 51. Conduct Sumpners test on the given pair of single phase transformers and obtain the regulation vs. output at 0.8 pf lag. 52. Conduct Sumpners test on the given pair of single phase transformers and obtain the regulation vs. output at 0.8 pf lead. 53. Conduct Sumpners test on the given pair of single phase transformers and obtain the regulation vs output at rated load. 54. Determine the maximum efficiency of each of the given pair of single phase transformer by conducting a back-to-back test on them. 55. Obtain the circuit model of the given pair of the single phase transformers referred to the LV side by conducting a back to back test. 56. Obtain the circuit model of the given pair of the single phase transformers referred to the HV side by conducting a back to back test. 57. Determine the voltage to be applied to the LV winding of the given pair of single phase transformers to supply rated load at rated voltage on 0.8 pf lag from the HV winding by conducting a back to back test. 58. Determine the voltage to be applied to the LV winding of the given pair of single phase transformers to supply rated load at rated voltage on 0.6 pf lead from the HV winding by conducting a back to back test. 59. Determine the terminal voltage across the load connected to the LV winding on the given pair of single phase transformers when rated current is supplied at rated voltage to the HV winding at 0.6 pf lag by conducting a back to back test. 60. Determine the terminal voltage across the load connected to the HV winding on the given pair of single phase transformers when rated current is supplied at rated voltage to the LV winding at 0.8 pf lead by conducting a back to back test. 61. Obtain the V-curves of the given synchronous generator at any two loads. 62. Obtain the efficiency vs. output characteristic of the given three-phase induction motor by loading the machine.

63. Obtain the line current vs. output characteristic of the given three-phase induction motor by loading the machine. 64. Obtain the power factor vs. output characteristic of the given three-phase induction motor by loading the machine. 65. Obtain the torque vs. line current characteristic of the given three-phase induction motor by loading the machine. 66. Determine the efficiency of the given three-phase induction motor at full load by conducting the no load and blocked rotor tests at the suitable values when the slip is 0.05. 67. Determine the efficiency of the given three-phase induction motor at half of full load by conducting the no load and blocked rotor tests at the suitable values when the slip is 0.02. 68. Determine the efficiency of the given three-phase induction motor at (3/4)th of full load by conducting the no load and blocked rotor tests at the suitable values when the slip is 0.03.

S-ar putea să vă placă și