27.74 1243 Flag 4 LS5 device 63 27.75 1244 Flag 5 LS5 device 63 27.76 1245 Flag 1 LS5 device 64 27.77 1246 Flag 2 LS5 device 64 27.78 1247 Flag 3 LS5 device 64 27.79 1248 Flag 4 LS5 device 64 27.80 1249 Flag 5 LS5 device 64 9.4.5 Factory Settings SimpIe (function) Extended (configuration) ResuIt [00.0x] FIag {x}; {x} = 1 to 7 f TRUE, flag {x} becomes TRUE. Deactivated by default. FALSE [00.08] FIag 8 - pre-configured to engine start via timer f TRUE, flag 8 becomes TRUE. TRUE once the configured time 1 has been reached [11.01], and the configured time 2 [11.02] has not been reached as well if the cur- rent day is the configured day [11.03] ( Chapter 4.7 'Configure LogicsManager' on page 319) Not available in operating modes "STOP" and "MAN" dependent on timer [00.09] Start request in Auto f TRUE, the engine is started in AUTOMATC operating mode. TRUE once discrete input [D 2] is energized. Note: This function is pre-configured and may be activated by passing through the command vari- ables [00.08] LM: Flag 8 or [04.03] Remote request ('' instead of '0'). Not available in operating modes "STOP" and "MAN". dependent on [D 2] [00.10] Stop request in Auto Functions Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 676 SimpIe (function) Extended (configuration) ResuIt f TRUE, the engine is either stopped in AUTO- MATC operating mode or a start of the engine is suppressed (also an emergency operation). Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE [00.11] Inhibit emergency run f TRUE, an emergency operation is inhibited or interrupted. Deactivated by default. Not available in operating modes "STOP" and "MAN". Only available in application mode , , , and . FALSE [00.12] UndeIay cIose GCB f TRUE, the GCB will be closed in an emer- gency operation without waiting for expiration of the delayed engine monitoring. TRUE once emergency mode is enabled. Only available in application mode to and operating modes "AUTO" and "MAN". dependent on emergency operation [00.14] Constant IdIe run f TRUE, the control outputs an "Constant idle run" if a start request for the generator is present Deactivated by default. FALSE [00.15] ExternaI acknowIedgment f TRUE, all alarms are acknowledged from an external source. TRUE once discrete input [D 5] is energized. dependent on discrete input [D 5] [00.16] Operation mode AUTOMATIC Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 677 SimpIe (function) Extended (configuration) ResuIt f TRUE the unit changes into AUTOMATC operating mode. Deactivated by default. FALSE [00.17] Operation mode MANUAL f TRUE the unit changes into MANUAL oper- ating mode. Deactivated by default. FALSE [00.18] Operation mode STOP f TRUE the unit changes into STOP operating mode. Deactivated by default. FALSE [00.19] Start without Ioad f TRUE, the engine is started without load transfer to the generator (closing the GCB is blocked). Deactivated by default. FALSE [00.20] Automatic IdIe mode f TRUE, the control performs an idle run for a configured time at start-up. Deactivated by default. Note This function is pre-configured and may be acti- vated by passing through the command variable [00.09] Start req. in Auto ('' instead of '0'). FALSE [00.21] Raise frequency/Ioad setpoint Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 678 SimpIe (function) Extended (configuration) ResuIt f TRUE, the frequency/load setpoint will be raised. Deactivated by default. FALSE [00.22] Lower frequency/Ioad setpoint f TRUE, the frequency/load setpoint will be low- ered. Deactivated by default. FALSE [00.23] Raise voItage/power factor setpoint f TRUE, the voltage/power factor setpoint will be raised. Deactivated by default. FALSE [00.24] Lower voItage/power factor setpoint f TRUE, the voltage/power factor setpoint will be lowered. Deactivated by default. FALSE [00.25] Frequency droop active f TRUE, the frequency droop is enabled. TRUE once missing members are detected on the load share bus. Not available in operating mode "STOP". dependent on missing mem- bers [00.26] VoItage droop active Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 679 SimpIe (function) Extended (configuration) ResuIt f TRUE, the voltage droop is enabled. TRUE once missing members are detected on the load share bus. Not available in operating mode "STOP". dependent on missing mem- bers [00.27] ExternaI mains decoupIing f TRUE, a mains failure is requested by an external device. Deactivated by default Not available in operation modes "STOP" and "MAN". FALSE [00.28] CriticaI mode f TRUE, the control performs a critical mode operation. Deactivated by default. TRUE, if no start failure is present and/or dis- crete input [D 1] is not energized. Not available in operation modes "STOP" and "MAN". dependent on start failure and [D 1] [00.29] Firing speed reached f TRUE, the unit recognizes that the ignition speed has been reached. Deactivated by default. FALSE [00.3x] FIag {y}; {x} = 0 to 5, {y} = 9 to 14 f TRUE, flag {y} becomes TRUE. Deactivated by default Not available in operation modes "STOP" and "MAN". FALSE [00.36] FIag 15 Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 680 SimpIe (function) Extended (configuration) ResuIt f TRUE, flag 15 becomes TRUE. Prepared for GCB fail to close or Synchroniza- tion time GCB. Not available in operating modes "STOP" and "MAN". dependent on GCB fail to close and Synchroniza- tion time GCB [00.37] FIag 16 f TRUE, flag 16 becomes TRUE. Prepared for Critical mode or Start without load. Not available in operating modes "STOP" and "MAN". dependent on Critical mode and Start without load [00.38] Synchronization mode CHECK f TRUE, the CHECK synchronization mode is enabled. Deactivated by default. Only available in operating mode "AUTO" and application mode to . FALSE [00.39] Synchronization mode PERMISSIVE f TRUE, the PERMSSVE synchronization mode is enabled. Deactivated by default. Only available in operating mode "AUTO" and application mode to . FALSE [00.40] Synchronization mode RUN f TRUE, the RUN synchronization mode is ena- bled. Deactivated by default. Only available in operating mode "AUTO" and application mode to . FALSE [00.81] Setpoint 2 frequency enabIed Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 681 SimpIe (function) Extended (configuration) ResuIt f TRUE, the frequency setpoint 2 is enabled. Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE [00.82] Setpoint 2 Ioad enabIed f TRUE, the load setpoint 2 is enabled. Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE [00.83] Setpoint 2 voItage enabIed f TRUE, the voltage setpoint 2 is enabled. Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE [00.84] Setpoint 2 power factor enabIed f TRUE, the power factor setpoint 2 is enabled. Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE [00.85] EnabIe MCB f TRUE, the MCB is enabled. TRUE, if discrete input [D 6] is energized and/or MCB did not fail to close and/or no mains phase rotation mismatch is detected. Only available in operating mode "AUTO" and application mode , , , , , and . dependent on [D 6] and MCB closure and mains phase rotation [00.86] Load-dependent start/stop Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 682 SimpIe (function) Extended (configuration) ResuIt f TRUE, load-dependent start/stop is enabled. Deactivated by default. Prepared for start request in AUTO and neither Flag 15 nor Flag 16 are enabled. Only available in operating mode "AUTO" and application mode to . FALSE [00.8x] Segment no. {y} active; {x} = 7 to 9; {y} = 2 to 4 f TRUE, load-dependent start/stop segment no. {y} is enabled. Deactivated by default. Only available in operating mode "AUTO" and application mode to . FALSE [00.9x] LDSS Priority {y}; {x} = 0 to 2; {y} = 2 to 4 f TRUE, load-dependent start/stop priority {y} is enabled. Deactivated by default. Only available in operating mode "AUTO" and application mode to . FALSE [00.9x] Transition mode {y}; {x} = 3 to 4; {y} = 1 to 2 f TRUE, transition mode {x} is enabled. Deactivated by default. Only available in operating mode "AUTO" and application mode , , , and . FALSE [24.1x] PID{y} ctrI. reIease; {x} = 7 to 9; {y} = 1 to 3 f TRUE, PD 1 control is released. Deactivated by default. Not available in operating modes "STOP" and "MAN". FALSE Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 683 SimpIe (function) Extended (configuration) ResuIt [00.41] ReIay 1 [R01] - Ready for operation OFF Relay will be de-energized if unit is not ready for operation or the logics manager output is TRUE. Deactivated by default Note: This function is pre-configured and may be activated by passing through the command vari- ables [01.09] Shutdown alarm or [04.01] Oper- ating mode AUTO or [00.01] LM: Flag 1 ('' instead of '0'). The unit is only ready for operation after an start- up delay following the power supply connection. FALSE [00.42] ReIay 2 [R02] - CentraIized aIarm (horn) / freeIy configurabIe Relay energizes if the internal condition "Horn" is TRUE dependent on Logics Com- mand Variable [03.05] [00.43] ReIay 3 [R03] - Starter / freeIy configurabIe Relay energizes if the internal condition "Starter" is TRUE dependent on Logics Com- mand Variable [03.02] [00.44] ReIay 4 [R04] - Start/Gas / freeIy configurabIe Relay energizes if the internal condition "Start/ Gas" is TRUE to energize the start (Diesel) or gas (Gas) solenoid dependent on Logics Com- mand Variable [03.28] [00.45] ReIay 5 [R05] - PregIow / Ignition / freeIy configurabIe Relay energizes if the internal condition "Pre- glow / gnition" is TRUE to preglow the Diesel engine or enabling the ignition of the gas engine dependent on Logics Com- mand Variable [03.04] [00.46] ReIay 6 [R06] - Free / Command: cIose GCB ReIay outputs Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 684 SimpIe (function) Extended (configuration) ResuIt n application mode and = freely configurable relay (unas- signed) n application mode to "Command: close GCB" Deactivated by default FALSE [00.47] ReIay 7 [R07] - Mains decoupIing / freeIy configurabIe / Command: open GCB n application mode pre-configured to mains decoupling. Relay energizes if the internal condi- tion "Mains decoupling" is TRUE to decouple the genset from the mains. n application mode to "Command: open GCB" Deactivated by default dependent on application mode and Logics Com- mand Variable [07.25] [00.48] ReIay 8 [R08] - Free / Command: cIose MCB n application mode , , , , , , , and = freely configurable relay (unassigned) n application mode and "Command: close MCB" Deactivated by default FALSE [00.49] ReIay 9 [R09] - Mains decoupIing / freeIy configurabIe / Command: open MCB n application mode , , , , , , , and pre-configured to mains decoupling. Relay energizes if the internal condi- tion "Mains decoupling" is TRUE to decouple the genset from the mains. n application mode and "Command: open MCB" Deactivated by default dependent on application mode and Logics Com- mand Variable [07.25] [00.50] ReIay 10 [R10] - AuxiIiary services / freeIy configurabIe n application mode , , , , , , and pre-configured to auxilary services. Relay energizes if the internal condi- tion "Aux. services" is TRUE to activate the aux- iliary services (it energizes prior to an engine start and de-energizes with the engine stop) n application mode , and "Com- mand: close GGB" dependent on Logics Com- mand Variable [03.01] [00.51] ReIay 11 [R11] - Warning aIarm cIass active / freeIy configurabIe Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 685 SimpIe (function) Extended (configuration) ResuIt n application mode , , , , , , and pre-configured to alarm classe A or B. Relay energizes if one of the alarm classes A or B is active n application mode , and "Com- mand: open GGB" dependent on Logics Com- mand Variable [01.08] [00.52] ReIay 12 [R12] - Shutdown aIarm cIass active / freeIy configurabIe Relay energizes if one of the alarm classes C, D, E or F is active dependent on Logics Com- mand Variable [01.09] [00.xx] ExternaI digitaI output {y} - Free (externaI expansion card, if connected; {xx} = 63 to 78 ; {y} = 1 to 16) Control of the external relay {y}, if this is con- nected Prepared for: Deactivated by default FALSE [24.xx] ExternaI digitaI output {y} - Free (externaI expansion card, if connected; {xx} = 01 to 16 ; {y} = 17 to 32) Control of the external relay {y}, if this is con- nected Prepared for: Deactivated by default FALSE DI AIarm cIass Pre-assigned to 1 F freely configurable EMERGENCY STOP 2 CONTROL freely configurable LogicsManager Start in AUTO 3 B freely configurable Low oil pressure 4 B freely configurable Coolant temperature 5 CONTROL freely configurable LogicsManager External acknowledgement 6 CONTROL freely configurable LogicsManager Enable MCB 7 fixed Reply MCB Discrete inputs Appendix LogicsManager Reference > Factory Settings 37528 easYgen-3400/3500 | Genset Control 686