Sunteți pe pagina 1din 11

Bulletin 1400/1402/1403

Power Quality and Automation Products


9

Bulletin 1400/1403
Powermonitor II 2890 ms Selectable Update Rates Simultaneous Multi-channel Ocillograph Recordings Time Stamped Data Logging of System Measurements and Events Power Monitoring Products Analysis and Capture Archival Control of Outputs and Communications Monitoring Capabilities for Energy Cost Allocation

Bulletin 1402
Line Synchronization Module Synchronization Anti-motoring Load Sharing Powermonitoring

TABLE OF CONTENTS
Description Page Description Page
Product Selection Bulletin 1403 Powermonitor II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 Bulletin 1402 Line Synchronization Module . . . . . . . . . . . . . . . . . . 9-3 Bulletin 1400 Powermonitoring Products . . . . . . . . . . . . . . . . . . . . 9-3 Accessories Bulletin 1403 Powermonitor II . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 Bulletin 1400 Powermonitoring Products . . . . . . . . . . . . . . . . . . . . 9-3 Specications Bulletin 1403 Powermonitor II . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Bulletin 1402 Line Synchronization Module. . . . . . . . . . . . . . . . . . 9-6 Bulletin 1400 Powermonitoring Products . . . . . . . . . . . . . . . . . . . . 9-7 Approximate Dimensions Bulletin 1403 Powermonitor II . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8 Bulletin 1402 Line Synchronization Module. . . . . . . . . . . . . . . . . 9-10 Bulletin 1400 Powermonitoring Products . . . . . . . . . . . . . . . . . . . 9-11

Description
Bulletin 1400 Bulletin 1400 series Powermonitors are 16 bit microprocessor-based digital instruments used for integrating the measured and calculated power parameters of industrial, commercial and utility power systems in automation systems. The capabilities of its on-board microprocessor and an advanced eld-congurable communication interface allows the unit to be used as either a stand-alone power monitor and control device or as one element in a large energy monitoring network.

Conformity to Standards:
IP54 (1400) IP10, IP65 (1403) CSA C22.2 No. 14; UL 508 ANSI/IEEE C37.90.1-1989 NEMA 4X Indoor (1403 Display Module)

Approvals:
CSA Certied UL Listed

Description
Bulletin 1402 Bulletin 1402 Line Synchronization Module (LSM) provides an integrated power generation control solution. The LSM design reduces the complexity of conventional technology, increases generator control performance, and provides an easily integrated automation platform for both retrot and new power facilities.

Your order must include:


Cat. No. of module and/or communication card selected. If required, Cat. No. of converter, software or communications module.

Conformity to Standards:
CSA C22.2 No. 14; UL 508 CSA C22.2 No. 213 Class I, Div. 2

Approvals:
CSA Certied UL Listed

9-1

Bulletin 1400/1402/1403

Power Quality and Automation Products


Product Selection Bulletin 1403 Powermonitor II Master Module
Description Type of Device Measured Current A Full Scale 1 1 5
Powermonitor II Master Module Cat. No. 1403-MM05A

Measured Voltage 120600V 120600V 120600V 120600V

Power Supply 120/240V AC 50/60 Hz or 125/250V DC 24V AC 50/60 Hz or 24V/48V DC 120/240V AC 50/60 Hz or 125/250V DC 24V AC 50/60 Hz or 24V/48V DC

Cat. No. 1403-MM05A 1403-MM05B 1403-MM01A 1403-MM01B

Bulletin 1403 Powermonitor II Display Module


Description 120/240V AC 50/60 Hz or 125/250V DC Cat. No. F

1403-DMA

Powermonitor II Display Module Cat. No. 1403-DM

12/24V AC 50/60 Hz or 12/240/48V DC

1403-DMB

Accessories for Bulletin 1403 Powermonitor II


Description Smart Communication Card 2 x 25 cm F Link 2 x 1 M F Link 2 x 3 M F Link 2 x 5 M F Link 10 M F Link 20 M F Link 50 M F Link 100 M F Link 250 M F Link 500 M F Bulk Termination Kit Connector (10) Splice Bushing (5) Pulling Bullet Fiber Stripper Tool Cat. No. 1403-NSC 1403-CF 000 1403-CF 001 1403-CF 003 1403-CF 005 1403-CF 010 1403-CF 020 1403-CF 050 1403-CF 100 1403-CF 250 1403-CF 500 1403-NTOL 1403-N10 1403-N11 1403-N12 1403-N13 F

9-2

Prices Consult Sales Office or price list

Bulletin 1400/1402/1403

Power Quality and Automation Products


Product Selection, Continued Bulletin 1402 Line Synchronization Module
Description Line Synchronization Module Power Source: PLCR Backplane 1.1A @ 5V DC Measured Parameters: Voltage 120V AC Input Impedance: 728 kOhm Current: 05A AC Burden: 0.02 VA Cat. No. 1402-LS51 F

Bulletin 1400 Powermonitor Products


Description Measured Current A Full Scale Measured Voltage L-N 120V 1 277V 347V 120V 5
Powermonitor Block Module Cat. No. 1400-PB11A

Type of Device

L-L 208V 480V 600V 208V 480V 600V 208V 480V 600V 208V 480V 600V

Power Supply 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC 85240V AC or 110300V DC 2060V DC

Cat. No. 1400-PB11A 1400-PB11B 1400-PB12A 1400-PB12B 1400-PB13A 1400-PB13B 1400-PB51A 1400-PB51B 1400-PB52A 1400-PB52B 1400-PB53A 1400-PB53B 1400-PD11A 1400-PD11B 1400-PD12A 1400-PD12B 1400-PD13A 1400-PD13B 1400-PD51A 1400-PD51B 1400-PD52A 1400-PD52B 1400-PD53A 1400-PD53B

277V 347V 120V

277V 347V 120V

5
Powermonitor Display Module Cat. No. 1400-PD11A

277V 347V

Accessories for Bulletin 1400 Powermonitor Products


Description Communication Card for Display Module Communication Card for Block Module Communication Converter (RS-232/RS-485) Local Display Powermonitor Software ControlView Power Monitoring Software Modem Cable Adapter Cat. No. 1400-DCU 1400-BCU 1400-CC 1400-SP 6190-PMO 1400-MCA F

Prices Consult Sales Office or price list

9-3

Bulletin 1400/1402/1403

Power Quality and Automation Products


Specifications Bulletin 1403 Powermonitor II
Metering Update Rates
Filter Mode 1 1 2 2 3 3 Min/Max Log Functionality Disabled Enabled Disabled Enabled Disabled Enabled Number of Congured Setpoints 0 20 0 20 0 20 Snapshot Log Interval Disabled 1/Second Disabled 1/Second Disabled 1/Second Real Time Metering Update Rate (ms) 27.9 45.6 51.9 67.1 68.6 87.1

Measurement Accuracy, Resolution and Range


Accuracy in Percent of Full Scale @ 25C 50/60 Hz 0.05% 0.05% 0.005 Hz 0.05 Hz Internal Resolution 0.025% 0.025% 0.825 S

Parameter Volts: V1, V2, V3 Current: I1, I2, I3, I4 Frequency: Power Functions: kW, kVA, kVAR Demand Functions: kW, kVA Energy Functions: kWH, kVAH Power Factor Harmonic Data (2nd41st) Analog Input

Range (Scale) 10115% of nominal 1140% of nominal 0.2140% of nominal 2075 Hz 75120 Hz

Nominal Value 120VL-N/208VL-L & 347VL-N/600VL-L 1A 5A

0.1%

VRange x IRange

VNominal x INominal

0.025%

0.1% 5% (of fundamental) 1%

0100% 0100% of nominal

100% 1.4V DC 1.0V AC

0.1% 0.4%

Accuracy is specified at terminals of Powermonitor II. User supplied transformers may affect accuracy. For detailed performance curves, refer to Publication 1403-2.2, Powermonitor II Specification Sheet. Actual full scale is determined by multiplying by user transformer ratio. Product Cat. No. identifies unit as a 1A or a 5A device.

Input and Output Ratings


Control Power 1403-MMxxA 120V/240V AC 50/60 Hz or 125V/250V DC (0.2 Amp maximum loading) 1403-MMxxB 24V AC 50/60 Hz or 24V/48V DC (1 Amp maximum loading) 1403-DMA 120V/240V AC 50/60 Hz or 125V/250V DC (0.05 Amp maximum loading) 1403-DMB 12V/24V AC 50/60 Hz or 12V/24V/48V DC (0.15 Amp maximum loading) Nominal Full Scale Input: 120V347V L-N (208V600V L-L) Input Impedance: 1 Meg-Ohm minimum Nominal Full Scale Input: 01 Amp (1403-MM01x) 05 Amps (1403-MM05x) Overload Withstand: 15 Amps Continuous, 300 Amps for one second Burden: 0.05 VA Impedance: 0.002 Ohms Contact Closure (Internal 24V DC) Nominal Input: 1.0V AC/1.4V DC Overload Withstand: 120V for one minute

Voltage Inputs

Current Inputs

Status Inputs Analog Input

9-4

Bulletin 1400/1402/1403

Power Quality and Automation Products


Specifications, Continued Bulletin 1403 Powermonitor II, Continued
Control Relay
Rating Maximum Resistive Load Switching Minimum Load Switching UL 508, CSA 22.2, IEC Rating Class Maximum Make Values (Inductive Load) 50/60 Hz AC rms 10A at 250V (2500VA) 10mA at 24V B300 30A at 120V 15A at 240V (3600VA) 3A at 120V 1.5A at 240V (360VA) 1/3 HP at 125V 1/2 HP at 250V DC 10A at 30V and 0.25A at 250V 10mA at 24V Q300 0.55A at 125V 0.27A at 250V (69VA) 0.55A at 125V 0.27A at 250V (69VA)

Maximum Break Values (Inductive Load) Maximum Motor Load Switching

Relay Life
Parameter Mechanical Electrical Number of Operations 5 X 106 1 X 105

General Specications
Control Power Dielectric Withstand Voltage Inputs Current Inputs Status Inputs Control Relays 1403-MM Voltage and Current Terminals Terminal Block (75C Cu wire only) 1600 Volts (Cat. No. 1403-MMxxA, -DMA) 1000 Volts (Cat. No. 1403-MMxxB, -DMB) 2200 Volts 4160 Volts 1000 Volts 1600 Volts 10 AWG (6 mm2) max., 16 lb-in (1.81 Nm) Torque 14 AWG (2.5 mm2) max., 5 lb-in (0.56 Nm) Torque

1403-MM Power, Status, Analog, Relay, and Ground Terminals 12 AWG (4 mm2) max., 8 lb-in (0.90 Nm) Torque 1403-NSC Terminals 1403-DM Terminals 14 AWG (2.5 mm2) max., 5 lb-in (0.56 Nm) Torque 40C60C (40F140F) Cat. No. 1403-MM, -NSC) 20C60C (4F140F) Cat. No. 1403-DM) 40C85C (40F185F) 5%95%, Non-condensing 10500 Hz: 1G Operational (0.006 in.) and 2.5G Non-operational (0.015 in.) 1/2 Sine Pulse, 11 ms duration: 15G Operational and 30G Non-operational

Operating Temperature Storage Temperature Humidity Vibration Shock

Fiber Optic Cable Assembly Specications


Parameter Minimum Maximum 500 m (1650 ft.) N/A Cable Length: 25 cm (approx. 10 in.) shortest Allen-Bradley standard Distance between two adjacent devices 25.4mm (1 in.) Any bends with a shorter inside radius can permanently damage Minimum inside bend radius the ber optic cable. Signal attentuation increases with decreased inside bend radii.

9-5

Bulletin 1400/1402/1403

Power Quality and Automation Products


Specifications, Continued Bulletin 1402 Line Synchronization Module
Inputs
Current Frequency Dielectric Withstand Voltage Burden Voltage Input Impedance/Burden 05A RMS Cont., 200A RMS 1 Second 4763 Hz (steady-state) 2500V RMS 0.0025 VA 120V RMS (339 Vpk-pk) Maximum Peak 728 kOhm/0.02 VA

Synchronization Window
Independent Upper and Lower Thresholds Voltage Frequency Phase 0.05% steps 0.01 Hz steps 1 degree steps 240V AC 24V DC 45 kOhm 1.1A at 5V DC 0C+60C (32F+140F) +40C+100C (+104F+212F) 5%95%, non-condensing

Isolated Load Sharing Input/Output


Max Common Mode Voltage Continuous Voltage Input Impedance Back Plane Power Requirements

Environmental
Operating Temperature Storage Temperature Humidity

Update Rate
Alternate Error Parameters Table 100 milliseconds Monitoring Parameters Tables 200 milliseconds (Synchronization Inactive) 2 seconds (Synchronization Active)

Accuracy@ 25C (77F)


Current Measurement = 0.2% of Full Scale (Full Scale = 1.4 x CT Primary) Voltage Measurement = 0.2% of Full Scale (Full Scale = 1.25 x PT Primary) Frequency Measurement = 0.05 Hz (Within the 4763 Range) Slip Frequency = 0.05 Hz (Within the 4763 Range) Power, Power Factor, VA = 0.4% of Full Scale Power Consumption (Full Scale = 1.75 x CT Primary x PT Primary)

9-6

Bulletin 1400/1402/1403

Power Quality and Automation Products


Specifications, Continued Bulletin 1400 Powermonitor Display and Block Module
Accuracy, Resolution, Ranges
Parameter Volts (V1, V2, V3) Amps (I1, I2, I3) Neutral Current (I4) kW kVAR kVA Power Factor Frequency kW Demand kVA Demand kWH (F, R) kVARH (F, R) Vaux (1V AC scale) IOUT Waveform Capture Accuracy 0.2% 0.2% 0.2% 0.4% 0.4% 0.4% 1.0% 0.2 Hz 0.4% 0.4% 0.4% 0.4% 0.25% 2.0% 2.0% Resolution 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 1.0% 0.1 Hz 0.1% 0.1% 1 kWH 1 kVARH 0.1% 1.0% 0.1% Range 01,000,000 030,000 09,999 01,000,000 01,000,000 01,000,000 1.0 0.6 40450 Hz 01,000,000 01,000,000 01,000,000,000 01,000,000,000 01,000,000 020mA N/A

Reads in kV for voltages over 9,999. Reads in MVA, MW, MVAR for readings over 9,999. 1 Hz resolution at 400 Hz range.

Input and Output Ratings


Nominal full scale input (+15%, 75%) Overload withstand: 2500V AC for 1 second Input impedance: 2 Megohm Nominal full scale input (+15%, 75%) 277VL-N/480VL-L Overload withstand: 2500V AC for 1 second Input impedance: 2 Megohm Nominal full scale input (+15%, 75%) 347VL-N/600VL-L Overload withstand: 2500V AC for 1 second Input impedance: 2 Megohm AC ONLY nominal full scale input, 5 Amps Overload withstand: 15 amps continuous, 300 amps for 1 second Input impedance: 0.002 ohm, Burden: 0.05 VA AC ONLY nominal full scale input, 1 Amp Overload withstand: 15 amps continuous, 300 amps for 1 second Input impedance: 0.002 ohm, Burden: 0.05 VA >20V AC/V DC = active, <6V AC/V DC = inactive, Minimum Pulse Width: 40 ms Input impedance: 49.2 kOhm, 277V AC/V DC maximum Resistive: 10A, 277V AC/30V DC Inductive: 240V AC, 3400 VA inrush, 360 VA sealed AC/DC 85V264V AC/0.2 Amps/ 47440 Hz or 110300V DC/0.2 Amps DC (optional) 20V60V DC @ 10W 1.0V AC/V DC nominal full scale input (1.25V AC/V DC maximum) Overload withstand: 120V continuous, 1000V for 1 second Input impedance: 10 kOhm 120VL-N/208VL-L 020mA output into 250 Ohm maximum load 1.35 Nm (12 lb-in) torque 4mm2 (12 AWG), 75C (167C) CU wire only 0C50C (32F122F) ambient air temperature range 30C+70C (22F158F) 595 percent, non-condensing

Voltage Inputs

Current Inputs

Status Inputs Control Relays Contact Ratings: (SPDT) Power Supply Auxiliary Voltage Input (VAUX) Auxiliary Current Output (IOUT) Terminal Strip Maximum Wire Operating Temperature Storage Temperature Humidity

9-7

Bulletin 1400/1402/1403

Power Quality and Automation Products


Approximate Dimensions Bulletin 1403 Powermonitor II Master Module Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
277 (10.91) 140 (5.512) Mounting 5.56 (.219) 4 Mounting Slots 85.9 (3.38)

68.5 (2.70) 7.6 (.30)

16.5 (.65)

203.2 (8.00)

190 (7.480) Mounting

165.1 (6.50)

87.8 (3.46)

122 106.2 (4.80) (4.18) with without Optional Optional Communications Communications Module Module

Bulletin 1403 Display Module Dimensions


22.23 (.875) 85.73 (3.375)

130.18 (5.125)

85.73 (3.375)

22.23 (.875) 130.18 (5.125)

16 (.630) 49.52 (1.954) Shoulder of Mounting Stud

130.18 (5.125)

9-8

Bulletin 1400/1402/1403

Power Quality and Automation Products


Approximate Dimensions, Continued Bulletin 1403 Display Module Mounting
34.93 (1.375) Ref.

34.93 (1.375) Ref.

136.53 (5.375) Recommended Vertical Spacing for Multiple Modules

136.53 (5.375) Recommended Horizontal Spacing for Multiple Modules

50.8 (2.00) Minimum Panel Depth

Bulletin 1403 Display Module Cutout Dimensions


85.730.25 (3.375.010) 1.688.010 (42.880.25)

85.730.25 (3.375.010)

101.6 +1.52 0.76

42.880.25 (1.688.010)

( .4.00

+.060 .360 Cutout

)
4.780.12 (.188.005) 4 Mounting Holes

Mounting Panel Cutout Dimensions for Bulletin 1403-DM_ Display Module

9-9

Bulletin 1400/1402/1403

Power Quality and Automation Products


Approximate Dimensions, Continued Bulletin 1402 Line Synchronization Module
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Approximate shipping weight is 2.72kg (6.0 lbs.).
9

1.57 (.06) 23.8 (.94) 31.72 62.26 (1.25) (2.45)

6.73 (.27) 53.94 (2.12)

254 (10.00)

126.87 (5.00)

17.65 (.70)

148.08 (5.83)
Line Synchronization Module Cat. No. 1402-LS51

9-10

Bulletin 1400/1402/1403

Power Quality and Automation Products


Approximate Dimensions, Continued Bulletin 1400 Powermonitor
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Gasket

7.70 (195.6) 7.20 (182.88)

6.50 (165.1)

.60 (15.2) 12.40 (315) .25 (6.4) 11.90 (302.26) 5.950 (151.13) 6.4 (.25) .57 (14.5) 4.01 (101.9) 4.8 (121.9)

# 1032 UNF 2A Mounting Stud 6 Places (Torque mounting nuts to 2733 in.lbs.) 11.10 (281.8)

Cat. No. 1400-PD 1400-PB 1400-DCU 1400-BCU

Approx. Ship. Wts. 3.2 kg (7.1 lbs) 2.5 kg (5.6 lbs) 0.18 kg (0.4 lbs) 0.18 kg (0.4 lbs)

.65 (16.6)

Powermonitor Display Module Cat. No. 1400-PD_ _ _ + Cat. No. 1400-DCU


11.38 (288.9) 2.93 (74.5) .30 (7.6) 5.512 (140) 5.56 (.219) 4 MOUNTING SLOTS 4.88 (124) 4.10 (104.2)

8.00 (203.2)

7.480 (189.99)

0.56 Nm (5 lb.-in.) Max Terminal Screw Torque 1.35 Nm (12 lb.-in.) Max Terminal Screw Torque

Powermonitor Power Block Module Cat. No. 1400-PB_ _ _ + Cat. No. 1400-BCU

9-11

S-ar putea să vă placă și