Sunteți pe pagina 1din 25

CONSTRUCT Y YOUR IDEAS

Pidilite Industries has been the pioneer and market leader in adhesives and sealants, construction chemicals, art & craft products and polymer emulsions in India. Pidilite started in 1959 manufacturing only white glue Fevicol, and have now grown to cater to various other categories including paint chemicals, automotive chemicals, art materials and stationery, fabric care, maintenance chemicals, industrial adhesives, industrial and textile resins and organic pigments preparations. Most of the products have been developed through our strong in-house R&D. Pidilite has some of the biggest brands in adhesives and sealants category. These brands include Fevicol, M-seal and Fevikwik. Fevicol have become synonymous with adhesives to millions in India and is ranked amongst the most trusted brands in the country. Some of our other major brands are Dr. Fixit, Pagel & Roff in Construction Chemicals, Cyclo and Motomax in auto care, Ranipal in fabric care, Fevistik glue stick and Hobby Ideas that is a Do-ItYourself range of hobby and craft products.

company prole

manufacturing and R&D

state-of-the-art

We develop most of our products in-house with the help of a strong, research-driven innovation led with consumer insights. All the products are manufactured under ISO 9000 certication. Our R&D team works closely with the marketing and technical service team to develop and enhance products that meet the continuously changing requirements of our customers.

Innovation being one of the core values of the company, Pidilite has established a state-of-theart research centre in Singapore to expand the companys product innovation strategy and attract international talent to work on in-house global brands. This Pidilite Innovation Centre, is now a member of Singapore Chemical Industry Council (SCIC).

construction chemicals division

Pidilite manufactures and markets a wide range of construction chemical products under two brands Dr. Fixit & Roff covering different aspects of construction like waterproong, building repairs, tile xing, admixtures, sealants, ooring and grouts. Pidilite is the countrys leading player in the retail market for Construction Chemicals with the Dr. Fixit & Roff brands. Under Dr. Fixit brand we offer a range of waterproong and repair solutions while Roff has a complete range of tile xing solutions. Besides a large & comprehensive product range, Pidilite has also trained and associated with a large pool of applicators to offer the right advice and solutions to its customers. Our products are available all across India & at our global subsidiaries in Middle East,

Thailand, Singapore and Brazil. Our Construction Chemicals products are also available in over 30 other countries. Pidilite Industries Ltd. has promoted Dr. Fixit Institute of Structural Protection and Rehabilitation (DFI-SPR), a standalone not-for-prot organization with a vision to become a premier national knowledge and skill development centre in waterproong and other areas of renewal engineering. The endeavour of DFI-SPR is to enhance the service life of Built Environment through global sharing knowledge & best practices in the eld of Waterproong, Structural Protection, Repair and Rehabilitation. It has also set up an Advance Diagnostic Lab and library for the industry professional on its campus.

Waterproong is a process that is designed to prevent water from penetrating a structure. Typically waterproong is done in various layers and stages to create multiple barriers so that water cannot penetrate the structure. A combination of such stages is referred to as creating a Building Envelope. However, often not enough importance is given to this very crucial area while constructing new structures. Over reliance on conventional and outdated systems, low awareness about modern waterproong systems and lack of trained expertise for application are some of the reasons for the same. Heres where Dr. Fixit can help you to get the best waterproong solutions for your new constructions. Dr. Fixit is Indias leading brand in

Waterproong with a wide variety of products and solutions to meet all your waterproong needs from foundations to walls to roofs. With access to the latest global technologies through its international subsidiaries and R&D centres, Dr. Fixit constantly brings innovative waterproong solutions. Dr. Fixit also offers full technical support with large pool of trained applicators. Call us now to benet from our state-of-the-art waterproong systems for your new constructions.

waterproong systems
5

state-of-the-art

Page No.
9 10

Areas of application
Basement waterproong/ damp-proong

System code
SBWP 10 SBWP 10

Waterproong systems
Shallow basements - Waterproong in low water table areas Alternatively, Shallow basements - Waterproong in low water table areas Deep basements Waterproong in high water table areas Deep basements Waterproong in high water table areas Waterproong system to prevent water loss (Raft slab and external walls) Waterproong system to prevent water loss (Internal area) Waterproong to prevent leakages from sloping roof Waterproong for the roofs with larger span Waterproong for the roofs with larger span Waterproong protection to swimming pool at podium or any other oor Waterproong for landscaped elevated swimming pools Exposed waterproong system for the at roofs Waterproong system under conventional brickbat coba Waterproong system for the at roofs Waterproong for proled metal sheet roofs Waterproong and heat insulation system for the at roofs Waterproong cum heat reduction system Terrace garden waterproong Terrace garden waterproong Wet area waterproong system Waterproong of new water tanks External walls waterproof coating Manhole waterproong Remedial treatment for existing roof Remedial waterproong for a leaking basement Remedial solution for Rising Dampness Repair to old roofs with bituminous treatments General construction & secondary waterproong Typical Expansion Joint Details at the roof level
7

11 12 14 15 17 18 19 20 22 24 25 26 27 28 29 31 32 34

Basement waterproong

DBWP 10 DBWP 15

Swimming pools

SWP 10 SWP 10

Terrace Waterproong

IPR 7 PWP 15 PWP 10 PWP 10 (LSP) PWP 10 (LSP) EFR 10 IFR 5 (BBC) CRW 7 MRW 15 IFRI 25 IFRI 10

Roof Garden

RGW 25 RGW 15

Wet areas New Water tank External Walls Manhole Remedial Waterproong

WW 15 WWT 7 EWWP 5 MHWP 10 EFR 7 LFB RD EFR GC&SW

contents

35 36 37 39 40 42 43 44 46

Detailing

TDW

Basement waterproong/ damp-proong


ShAllOw bAsements - WAterprOOfing in LOW WaTER TaBLE aREaS DR. FIXIT SOLYsEAL

System Life Expectancy of 10 years

Excellent water vapour and moisture barrier for prevention of dampness in basements

Methodology
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming A swellable, adhesive strip waterbar of 20 mm X 20 mm, Dr. Fixit Waterbar SW 2020 shall be provided in the construction joints, which is placed on the inside of the reinforcement, in both the raft concrete oor & the side retaining concrete walls. Application on vertical surfaces Apply Dr. Fixit Solyseal diluted with water in 1:1 proportion as primer to clean, smooth and dry surface by brush or roller. Allow the primer to dry prior to the application of the Dr. Fixit Solyseal Application on PCC below the raft slab Apply the 1 st coat of Dr. Fixit Solyseal without any dilution and allow it to dry completely. Start the 2nd coat of Dr. Fixit Solyseal, with a roller or a rubber squeegee & allow it to dry. Lay geotextile membrane of 120 gsm as a protection layer over the Dr. Fixit Solyseal coating. A 50 mm thick leveled screed must be overlaid in M 20 concrete grade, which will facilitate the reinforcement cage to be assembled, for the RCC raft to be cast over it. Make angle llets all around the corners of the raft and the retaining wall. Make the llets with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. Take care to chamfer all the edges of screed and raft slab to facilitate the membrane to move over it. Apply two coats of Dr. Fixit Solyseal on all vertical surfaces of raft slab and retaining walls. Lay 250 gsm geotextile membrane / bituminous protection boards on the Dr. Fixit Solyseal coating before the back lling.
1 PCC 2 Angle llet 3 Primer 4 Dr. Fixit Solyseal (2 coats) 5 Geotextile fabric 6 Screed 7 Dr. Fixit Waterbar SW2020 8 Protection board 9 Dr. Fixit Solyseal

SBWP 10

basement solutions

9 7 6 8 5 4 3 2 1

Dr. Fixit Solyseal


Polymer modied elastomeric bituminous coating

Dr. Fixit Waterbar


Flexible adhesive waterstop strip

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
9

Basement waterproong/ damp-proong


ShAllOw bAsements - WAterprOOfing in LOW WaTER TaBLE aREaS ALTERNATIVELY, DR. FIXIT SAMsHIELd XL 1500 / 2100

Basement waterproong
System Life Expectancy of 10 years

Protection from chemical contamination in soil along with excellent waterproong


Deep bAsements WAterprOOfing in HiGH WaTER TaBLE aREaS DR. FIXIT TORCHsHIELd SP 4160 (SBS) in double layer

System Life Expectancy of 10 years

Robust tanking system for high performance basement waterproong

Methodology
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming Apply Dr. Fixit Torchshield Primer to clean, smooth and dry surface by brush or roller. Allow the primer to dry prior to the application of the Dr. Fixit Samshield XL . Application on PCC below the raft slab Peel off the release lm from the Dr. Fixit Samshield XL self adhesive side and start unrolling the membrane and press it to the surface. Smoothen the membrane from the center to the edges with a wooden press in order to remove entrapped air. Furthermore, an iron roller shall be used for rolling on top of the applied membrane to ensure a proper and strong adhesion of the bitumen compound with the base. A 50 mm selvedge is provided on one side of the membrane to give bitumen to bitumen contact on the overlaps. Lay geotextile membrane of 120 gsm as a protection layer over the Dr. Fixit Samshield XL membrane. A screed of 50 mm must be overlaid in M 20 concrete grade, which will facilitate the reinforcement cage to be assembled, for the RCC raft to be cast over it. A swell able, adhesive strip waterbar of 20 mm X 20 mm, Dr. Fixit Waterbar SW 2020 shall be provided in the construction joints, which is placed on the inside of the reinforcement, in both the raft concrete oor & the side retaining concrete walls. Application on vertical surfaces Make angle llets all around the corners of the raft and the retaining wall. Make the llets with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. Take care to chamfer all the edges of screed and raft slab to facilitate the membrane to move over it. Dr. Fixit Samshield XL membrane must be applied starting with the sides of the raft and will go right up to the top of the external wall face and terminated there, appropriately with C-Shaped Aluminium ashing strip or by tucking it into the concrete wall of a groove of 12 mm X 12 mm. In case of the groove, the aluminium ashing can be tted to press the membrane into the groove and then be lled with a single component Dr. Fixit PU Sealant. Place bituminous protection boards over the Dr. Fixit Samshield XL membrane before backlling.
1 PCC 2 Dr. Fixit Torchshield Primer 3 Dr. Fixit Samshield XL 1500/2100 4 Geotextile fabric 5 Screed 6 Dr. Fixit Waterbar SW2020 7 Protection Board

SBWP 10

Methodology
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming All over the blinding concrete or PCC that is properly leveled, Dr. Fixit Torchshield Primer priming shall be done with a roller or brush, over a dried surface. Allow the primer to dry for 8 to 10 hrs. Application on PCC below the raft slab is placed on the inside of the reinforcement, in both the raft concrete oor & the side retaining concrete walls. Application on vertical surfaces Over the RCC raft, the side retaining walls are cast in concrete. Prepare the retaining wall surface to receive waterproong system as detailed in surface preparation above. After the application of primer and drying it, 2 layers of Dr. Fixit Torchshield SP 4160, a SBS based polyester reinforced membrane shall be laid. A 4 mm thick bituminous protection board or a HDPE dimpled drain board (12 mm thick) shall be placed, vertically over the Torchshield membrane, allowing the soil backll. As the activity goes upward, the application of Dr. Fixit Torchshield membrane, along with the protection system shall be carried out minimum 300 mm above the ground level or as per nished oor level, with C-Shaped Aluminium ashing strip or by tucking it into the concrete wall of a groove of 12 mm X 12 mm. In case of the groove, the aluminium ashing can be tted to press the membrane into the groove and then be lled with a single component Dr. Fixit PU Sealant. ALTERNATIVELY Dr. Fixit Torchshield AP 4160 (APP) membrane in two layers can be used in place of Dr. Fixit Torchshield SP 4160
1 PCC 2 Primer

DBWP 10

3 Dr. Fixit Torchshield SP4160 (2 layers) 4 Geotextile 5 Screed 6 Dr. Fixit Waterbar SW2020 7 Angle Filet 8 Protection board

7 6 6 5 4 3 2

Dr. Fixit Torchshield SP 4160, a SBS based polyester reinforced membrane, shall be laid by providing an overlap of at least 100 mm. A 2 layer of SBS based membrane Dr. Fixit Torchshield SP 4160 shall be laid with an overlap 50 % above the 1st layer.
nd

8 6 5 4 7 3 2 1

Torchshield membrane Dr. Fixit Torchshield SP 4160, shall be extended to maximum extent of the full area of the blinding concrete. Lay geotextile membrane of 120 gsm as a protection layer over the Dr. Fixit Torchshield SP 4160 membrane. A screed of 50 mm must be overlaid in M 20 concrete grade, which will facilitate the reinforcement cage to be assembled, for the RCC raft to be cast over it. A swellable, adhesive strip waterbar of 20 mm X 20 mm, Dr. Fixit Waterbar SW 2020 shall be provided in the construction joints, which

Dr. Fixit Samshield


Self adhesive bituminous membrane

Dr. Fixit PU Sealant


One part non-sag polyurethane sealant

Dr. Fixit Waterbar


Flexible adhesive waterstop strip

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Waterbar


Flexible adhesive waterstop strip

Dr. Fixit PU Sealant


One part non-sag polyurethane sealant

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
11

Basement waterproong
System Life Expectancy of 15 years
Deep bAsements WAterprOOfing in HiGH WaTER TaBLE aREaS DR. FIXIT FLEXsHIELd (EPDM MEMBRANE)

High performance basement waterproong system

DBWP 15
Surface Preparation For horizontal application, the new concrete layer must be smooth and level and to be left to mature for at least 72 hours. Before laying the waterproong membrane, the surface must be cleaned of any waste. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Where the separate concrete layers are poured at different levels, the gaps must be lled and smoothed, in order to obtain a comparatively smooth surface. When cleaning the substrate, any pollutants, such as chemicals, curing agents etc., which may affect the membrane adhesion, must be removed. Installation of Dr. Fixit Flexshield membrane Whenever Dr. Fixit Flexshield membrane is being installed, it is highly recommended that the membrane shall be laid at the position and allowed to relax for at least 45 minutes. This will help releasing the tensions in the membrane. Always use geotextile 250 gsm for protection of the waterproong membrane, loose laid on the concrete substrate. On the horizontal sections the Dr. Fixit Flexshield membrane is loose laid between two layers of geotextile 120 gsm. The adjoining membrane sheets are seemed using a splice tape, as the overlapping must be at least 150 mm wide. A 50 mm protective cementsand screed is laid on the installed horizontal sections of waterproong system. Its purpose is to protect the waterproong system from damages, during the installation of the supporting structure (reinforcing, concrete casting, vibrations etc.) In the vertical sections, the membrane may be fully adhered or loose laid using mechanical fastening at the upper end. The walls must be dry and smooth, without any lumps, sharp edges and protruding reinforcement. Aluminum ashings should be used for the mechanical fastening, sealed with Dr. Fixit Silicon Sealant at the upper end. In case of full bonding the membrane to vertical surfaces, these must be clean and dry. The bonding adhesive is applied both to the membrane and to the substrate in uniform and smooth lms; so that a continuous coverage of both surfaces can be obtained (membrane and substrate). The adhesive is left to cure, and then the membrane with the applied adhesive is rolled onto the adhesive covered substrate, avoiding the formation of folds and creases. The adjoining membrane sheets must overlap by approximately 150 mm. The underground waterproong system is nished at 500 mm above the level of the high soil waters. The protective layer of geotextile 500 gsm is spot-adhered to the vertical Dr. Fixit Flexshield membrane, using bonding adhesive.

Methodology

Dr. Fixit Flexshield


EPDM based waterproong membrane

Dr. Fixit Silicone Sealant


Acetic cure silicone sealant

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
13

Swimming pools

Swimming pools below ground level


WAterprOOfing sYstem tO preVent wAter lOss DR. FIXIT TORCHsHIELd SP 4160

System Life Expectancy of 10 years

Swimming pools below ground level


Tough waterproong system for below grade application
WAterprOOfing sYstem tO preVent wAter lOss DR. FIXIT FASTFLEX

System Life Expectancy of 10 years

Highly puncture resistant and tough below grade waterproong membrane system

Methodology
RaFT SLaB anD EXTERnaL WaLLS Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming All over the blinding concrete or PCC that is properly leveled, Dr. Fixit Torchshield Primer priming shall be done with a roller or brush, over a dried surface. Allow the primer to dry for 8 to 10 hrs. Application on PCC below raft slab Dr. Fixit Torchshield SP 4160, SBS based polyester reinforced membrane, shall be laid by providing an overlap of at least 100 mm. Dr. Fixit Torchshield SP 4160 shall be extended to maximum extend of the full area of the blinding concrete. Lay geotextile membrane of 120 gsm as a protection layer over Dr. Fixit Torchshield SP 4160 membrane. A scred of 50 mm must be overlaid in M 20 concrete grade, which will facilitates the reinforcement cage to be assemble, for the RCC raft to be cast over it. Application on retaining wall Concrete joints in retaining walls and at raft level shall be provided with a swellable, compressible, adhesive strip Dr. Fixit Waterbar SW 2020 of 20 mm X 20 mm size, which shall be placed in joints while concreting of raft slab and retaining walls. 40 mm X 40 mm sized angle llets must be provided at the corners, all around the swimming pool oor and walls from external side. Prepare the retaining wall surface by cleaning and priming it with Dr. Fixit Torchshield Primer to receive waterproong system. Apply Dr. Fixit Torchshield SP 4160 starting from the bottom of external wall, right up to the ground level. Ensure that Dr. Fixit Torchshield SP 4160 is applied up to at least 300 mm above the ground level. After completion of application place a 4 mm thick bituminous protection board or a 12 mm thick dimpled HDPE drainage boards for protection. Alternatively, Dr. Fixit Samshield XL 1500/ 2100 can be used instead of Dr. Fixit Torchshield SP4160
1 PCC 2 Dr. Fixit Torchshield Primer 3 Dr. Fixit Torchshield SP 4160 4 Geotextile fabric 5 Screed 6 Dr. Fixit Waterbar SW2020 7 Protection Board

SWP 10

Methodology
InTERnaL aREa Surface Preparation The internal surface areas (horizontal and vertical) shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. At internal side walls and raft junction cast 40 mm X 40 mm sized angle llets all around the swimming pool oor. The inserts shall be wrapped around with Dr. Fixit Bathseal Tape to ensure a water-tight tting. Light tting casings, pipes, inserts, etc., provided in the concrete raft oor and walls are to be grouted with a non-shrink grout, Dr. Fixit Bathseal Grout. Dr. Fixit Fastex should be liberally applied around the insert pipes and the around the light ttings sandwiched with an open woven mesh to be extra precaution about these points. Tiles shall then be applied using tile adhesives from ROFF range depending upon whether they are glass mosaics, or ceramics. After the tile xing ll the grooves / tile joints with epoxy based ROFF RTM tile grouts.
1 Binding Concrete (PCC) 2 Dr. Fixit Torchshield Primer 3 Dr. Fixit Torchshield AP 4160 4 Geotextile 5 Concrete screed 6 Concrete raft slab 7 Dr. Fixit Fastex (2 coats) 8 Dr. Fixit Fastex (3rd coat with sand) 9 Roff NSA & Roff RTM Epoxy Grout

SWP 10

7 6 5 4 3 2 1

Application After complete curing of the raft slab and retaining walls apply 1 st coat of Dr. Fixit Fastex maintaining the saturated surface dry condition. While the coat is still wet embed a glass bre mesh of 2.5mm x 2.5 mm of 50 gsm over the angle llets as a reinforcing strip and allow it to soak completely. Immediately apply one additional coat to sandwich this glass bre mesh between the Dr. Fixit Fastex coatings. Apply the 2nd coat of Dr. Fixit Fastex . After the 2nd coat is completely dry apply 3rd coat of Dr. Fixit Fastex and sprinkle coarse sand while it is still wet. This will provide the key for subsequent tile adhesive materials.

10 Light xture with Dr. Fixit Bathseal Grout 11 Pipe opening with Dr. Fixit Bathseal Grout

11

9 8 7 6 5 4 3 2 1

10

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Waterbar


Flexible adhesive waterstop strip

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Fastex


High performance polymer modied cementitious coating

Dr. Fixit Bathseal Grout


Non-shrink grout for pipe tting

Dr. Fixit Bathseal Tape


Leak-proof sealing tape for pipe wrapping

Roff RTM Epoxy


Epoxy based tile joint ller
15

Pitched tiled roofs (with battens)


WAterprOOfing tO preVent leAKAges frOm slOping rOOf DR. FIXIT NEWCOAT

System Life Expectancy of 7 years

Heavy duty, bre reinforced, UV resistant, elastomeric waterproong coating system

Methodology
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming Apply 3rd coat of Dr. Fixit Newcoat all over the area covering the wooden batten. Carefully x tiles on the batten. Take care not to rupture the coating while xing tiles. Never x batten by hammering nails in concrete. It will damage the roof. Always use a drill machine to x screws.
1 Concrete roof 2 Dr. Fixit Primeseal 3 Dr. Fixit Newcoat (1st Coat) 4 Glass bre mesh 5 Dr. Fixit Newcoat (2nd Coat) 6 Dr. Fixit Newcoat (3rd Coat) 7 Wooden battens 8 Roof Tiles 9 Stainless Steel Screw

IPR 7

Waterproong

Apply Dr. Fixit Primeseal to a clean, smooth surface by brush or roller. Allow the primer to dry prior to the application of Dr. Fixit Newcoat. During application of Dr. Fixit Primeseal always maintain the saturated surface dry condition. Application Apply 1 st coat of Dr. Fixit Newcoat and while it is still wet, lay an open-woven 2.5 x 2.5 mm glass bre mesh and allow it to soak completely. Immediately apply 2nd coat of Dr. Fixit Newcoat to embed the mesh in coating. Allow it to dry completely. Fix the wooden battens by drilling and using steel screws for xing to avoid rusting. After drilling holes and before xing the screws x Dr. Fixit Bathseal Tape on bottom as well as top side of the batten. This will ensure a perfect seal around the screwed area. The battens must have enough number of grooves depending upon the length of the roof, for efcient drainage of water in case there is breakage of tiles.
Wooden batten with grooves

8 7 6 5 4 3 2 1

Terrace

Dr. Fixit Newcoat


Heavy duty reinforced acrylic waterproong coating

Dr. Fixit Bathseal Tape


Leak-proof sealing tape

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
17

Podium Waterproong
WAterprOOfing fOr the rOOfs with lArger spAn

Podium Waterproong
System Life Expectancy of 15 years

Highly exible, tough and puncture resistant waterproong system that sustains structural movements

WAterprOOfing fOr the rOOfs with lArger spAn ALTERNATIVELY,

System Life Expectancy of 10 years

Reliable waterproong system with exibility to accommodate structural movements

DR. FIXIT EXTEnsA

DR. FIXIT FLEXICOAT PU

Methodology
Surface Preparation All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Make angle llets all around the periphery of the podium wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. All surfaces must be cleaned with compressed air, free of loose materials, oils, form release agents and other contaminants Priming Priming generally not required on concrete substrates for Dr. Fixit Extensa.

PWP 15
Application After drying, spray apply Dr. Fixit Extensa to achieve minimum thickness of 1.5 mm Dr. Fixit Extensa is applied through compatible equipment only. It cannot be sprayed through other types of commonly available sprayers. A geotextile fabric of 300 gsm shall be placed over the membrane before laying the concrete screed of 75 mm (average) modied with Dr. Fixit Pidiproof LW+ with 1:100 slope properly aligned with drain outlets for efcient drainage of water.
1 Slab 2 Dr. Fixit Extensa 3 Geotextile 4 Angle Fillet 5 Drip Mould 6 Screed

Methodology
Surface Preparation All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Make angle llets all around the periphery of the podium wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. All surfaces must be cleaned with compressed air, free of loose materials, oils, form release agents and other contaminants. Priming Priming generally not required on concrete substrates for Dr. Fixit Flexicoat PU. Application Dr. Fixit Flexicoat PU should be applied by brush, trowel, and squeegee in two coats maintaining the spreading rate to achieve the desired DFT of 1.5 mm. Dr. Fixit Flexicoat PU membrane must be air cured for a minimum of 72 hours @27 C before placing protection. After drying of the coating lay a layer of geotextile membrane of 300 gsm After laying the geotextile membrane a screed of 75 mm (average) must be overlaid in M 20 concrete grade for the protection of membrane and to provide a proper slope for effective draining of rain water.
1 Slab 2 Dr. Fixit Flexicoat PU 3 Geotextile 4 Angle Fillet 5 Drip Mould 6 Screed

PWP 10

6 5 4 3 2 1

6 5 4 3 2 1

Dr. Fixit Extensa


Highly elastomeric and puncture resistant waterproong coating

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Flexicoat PU


Pitch modied polyurethane membrane coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
19

Podium Waterproong with landscaping and swimming pool


WAterprOOfing prOtectiOn tO swimming pOOl At pOdium Or AnY Other flOOr DR. FIXIT EXTEnsA & DR. FIXIT FAsTfLEX

System Life Expectancy of 10 years

Highly exible, tough waterproong system that easily bears pressure exerted by water column

Methodology
Surface Preparation All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. All surfaces must be cleaned with compressed air, free of loose materials, oils, form release agents and other contaminants. Light tting casings, pipes, insert, etc., provided in the concrete raft oor and walls are to be grouted with a non-shrink grout, Dr. Fixit Bathseal Grout. The inserts shall be wrapped around with Dr. Fixit Bathseal Tape to ensure a water-tight tting. Priming Priming generally not required on concrete substrates for Dr. Fixit Extensa. Application Spray apply Dr. Fixit Extensa to achieve minimum thickness of 2.0 mm Dr. Fixit Extensa is applied through designated equipment only. It cannot be sprayed through any other type of commonly available sprayers. Extend the Dr. Fixit Extensa coating up to the top and covering the overow concrete channels all around the periphery of the pool. As per the plans drawn up by the structural engineer, lay the steel cage accordingly. Reinforcing steel must be installed after the plumbing is complete. The steel is installed in a grid pattern following the requirements of the engineering calculations. Steel bar size can range from 3/8 diameter to 3/4 diameter depending on the requirements. Concrete spacers ensure the steel is not against the wall or the oor of the pool. This system allows shotcrete to be evenly distributed under and above the steel. A rule of thumb to remember when designing swimming pools is to minimize the number of separation joints between concrete sections in the pool! Finish the shotcrete area with wooden oat. After curing and drying make angle llets if necessary, all around the periphery of the pool wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. Now the shell of the swimming pool is ready to receive further waterproong system. Apply 1 coat of Dr. Fixit Fastex maintaining the saturated surface dry condition.
st

PWP 10 (LSP)
Apply the 2nd coat of Dr. Fixit Fastex . After the 2nd coat is completely dry apply 3rd coat of Dr. Fixit Fastex and sprinkle coarse sand while it is still wet. This will provide the key for subsequent tile adhesive materials. Dr. Fixit Fastex should be liberally applied around the inserts, pipes and the around the light tting casings, sandwiched with an open woven mesh as an extra precaution about these points. Now, start the application of tile adhesives from ROFF range depending upon whether they glass mosaics, or ceramics and ll the grooves / tile joints with epoxy based RTM coloured tile grouts.
1 Floor Concrete 2 Dr. Fixit Extensa 3 Steel cage with pedestal 4 Shortcrete 5 Dr. Fixit Fastex (2 coats) 6 Dr. Fixit Fastlex (3rd coat with sprinkled sand) 7 Roff NSA & Roff RTM tile grout 8 Concrete Wall 9 Pipe inlet tting Dr. Fixit Bathseal Tape & Dr. Fixit Bathseal Grout
10 Light tting casing with Dr. Fixit Bathseal Grout &

Dr. Fixit Bathseal Tape


11 Steel Grating

11 10 9 8 7 6 5 4 3 2 1

While the coat is still wet embed a glass bre mesh of 2.5 mm x 2.5 mm of 50 gsm over the angle llets and allow it to soak completely. Immediately apply one additional coat to sandwich this glass bre mesh between the Dr. Fixit Fastex coatings.

Dr. Fixit Extensa


Highly elastomeric and puncture resistant waterproong coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Fastex


High performance polymer modied cementitious coating

Dr. Fixit Bathseal Tape


Leak-proof sealing tape for pipe wrapping

Dr. Fixit Bathseal Grout


Non-shrink grout for pipe tting

Roff Rainbow Tile Mate


Unsanded cement based tile joint ller
21

Podium Waterproong with landscaping and swimming pool


WAterprOOfing fOr lAndscAped eleVAted swimming pOOls DR. FIXIT EXTEnsA & DR. FIXIT FAsTfLEX

System Life Expectancy of 10 years

Highly exible, tough waterproong system that easily bears pressure exerted by water column

Methodology
LanDSCaPinG Surface Preparation All surface imperfections, protrusions, structurally unsound and friable concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Make angle llets all around the periphery of the podium wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. All surfaces must be cleaned with compressed air, free of loose materials, oils, form release agents and other contaminants. Priming Priming generally not required on concrete substrates for Dr. Fixit Extensa. Application After drying, spray apply Dr. Fixit Extensa to achieve minimum thickness of 1.5 mm Dr. Fixit Extensa is applied through compatible equipment only. It cannot be sprayed through other types of commonly available sprayers. A geotextile fabric of 300 gsm shall be placed over the membrane before laying the concrete screed of 75 mm (average) modied with Dr. Fixit Pidiproof LW+ with 1:100 slope properly aligned with drain outlets for efcient drainage of water. For extensive roof gardens on a primed surface with Dr. Fixit Torchshield Primer, torch apply Dr. Fixit Torchshield AR (anti-root membrane) on the concrete screed. Place a 12 mm HDPE drainage board. Place a loosely laid geotextile fabric of 150 gsm again, over the entire drainage board to contain the soil. Place soil for vegetation accordingly.
1 Slab 2 Dr. Fixit Extensa 3 Geotextile 4 Screed 5 Dr. Fixit Torchshield Primer 6 Dr. Fixit Torchshield AR 4160 7 HDPE Drain Board 8 Geotextile 9 Soil
10 11 12 13

PWP 10 (LSP)

13 10 9 8 7 12 11 6 5 4 3 2 1

Vegetation Angle llet Gravel Drip mould

Dr. Fixit Extensa


Highly elastomeric and puncture resistant waterproong coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Fastex


High performance polymer modied cementitious coating
23

Exposed at roofs
System Life Expectancy of 10 years
EXpOsed wAterprOOfing sYstem fOr the flAt rOOfs DR. FIXIT TORCHsHIELd AP 4160 & AM 4160

Reliable lightweight waterproong membrane system with UV resistant mineral nish

Flat roofs with brickbat coba


WAterprOOfing sYstem under cOnVentiOnAl bricKbAt cObA DR. FIXIT SOLYsEAL

System Life Expectancy of 5 years

Highly elastomeric waterproong system below brickbat coba

Methodology
Surface Preparation Thorough surface preparation is a must over the entire roof area Screed in concrete in M 20 modied with Dr. Fixit Pidiproof LW+ must be laid with a slope of 1 in 100, with at least 50 mm thickness at the drain outlet. Screed must be cured and dried completely. Priming Prime the surface with Dr. Fixit Torchshield Primer. Allow it to dry for 8 to 10 hrs. Application Start the application of a rst layer of Dr. Fixit Torchshield AP 4160 (plain nish APP based) The application must start from the outlet, going towards the centre of the roof area. This 1 layer is laid, up to over the angle llet only.
st

EFR 10

Methodology
Surface Preparation Application Apply the 1 st coat of Dr. Fixit Solyseal without any dilution and allow it to dry completely. Start the 2nd coat of Dr. Fixit Solyseal, with a roller or a rubber squeegee & allow it to dry. Place loosely laid geotextile fabric of 300 to 500 gsm over the Dr. Fixit Solyseal for protection. Carefully lay brickbat coba to provide slope 1:100 for effective drainage of water.
1 Slab 2 Primer 3 Angle Fillet 4 Dr. Fixit Solyseal (2 coats) 5 Geotextile 6 Brickbat coba 7 Drip Mould

IFR 5 (BBC)

The 2nd layer of Dr. Fixit Torchshield AM 4160 must laid in a perpendicular direction to the 1st membrane, starting from 150 to 200 mm on the parapet wall, downward and covering the angle llet. This is a mineral nished APP based membrane 4 mm thick. The surface area of Dr. Fixit Torchshield AM 4160 has mineral slate on the surface and it can be left exposed it should be terminated at a height of 20 cm. The top edge of the membrane will be nished with 2 mm thick aluminium ashing pointed with Dr. Fixit Pidiseal PS 42P.

1 Slab 2 Screed 3 Angle Fillet 3 Dr. Fixit Torchshield Primer 4 Dr. Fixit Torchshield AP 4160 5 Dr. Fixit Torchshield AM 4160 6 Aluminium Flashing 7 Dr. Fixit Pidiseal PS 42P

The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Make angle llets all around the periphery of the terrace with a cement sand mortar admixed with Dr. Fixit Pidicrete URP. Priming
8 7

Apply Dr. Fixit Solyseal diluted with water in 1:1 proportion as primer to clean, smooth and surface by brush or roller in saturated surface dry condition and allow it to dry completely.

7 6 5

5 4 1

6 3

4 3 2

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Pidiseal PS 42P


Two-part polysulphide sealant

Dr. Fixit Solyseal


Polymer modied elastomeric bituminous coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
25

Commercial Flat Roofs


WAterprOOfing sYstem fOr the flAt rOOfs DR. FIXIT SOLYsEAL

Metal roofs
System Life Expectancy of 7 years

Easy to apply, elastomeric waterproong coating that can be applied over contours or projections in the roof
WAterprOOfing fOr prOfiled metAl sheet rOOfs DR. FIXIT FLEXsHIELd T45/T60

System Life Expectancy of 15 years

Extremely tough, exible, lightweight and eco friendly membrane system

Methodology
Surface Preparation Provide slope in new construction during casting roof slab (1 in 100 or 1 in 80) Thorough surface preparation is a must over the entire roof area Provide angle llets in cement sand mortar admixed with Dr. Fixit Pidicrete URP, of 50 mm x 50 mm all along the junction of the parapet wall & the roof slab. Dr. Fixit Bathseal Tape must be wrapped around all pipe inserts & protrusions in the slab Priming Apply Dr. Fixit Solyseal diluted with water in 1:1 proportion as primer to clean, smooth and dry surface by brush or roller in saturated surface dry condition. Allow the primer to dry prior to the application of the Dr. Fixit Solyseal. Extend the primer over the angle llets, up to the drip mould on the parapet wall. Application Apply rst coat of Dr. Fixit Solyseal Over the wet coat, place and press down an open woven mesh of glass bre and allow it to soak completely. Immediately apply 2nd coat of Dr. Fixit Solyseal to embed the mesh in coating. Allow it to dry completely.
7

CRW 7
Surface Preparation 48-72 hours later, place a loosely laid geotextile fabric of at least 100 gsm with 30 cm overlaps. Over the geotextile fabric, lay 50 mm thick leveled screed in M 20 grade. Screed can be cast in alternate bays method. 12 mm thick wooden battens must be cut to size according slope and xed on the roof surface with the help of sand cement mortar. Each bay size shall not be more than 10 sq. mtr (3.25 mtr x 3.25 mtr) and the areas of the bay near the parapet wall shall not be more than 2.25 sq. mtr. Upon completion of the laying of screed and complete drying and curing of the screed, wooden battens must be removed and lled with a compressible board e.g. bitumen impregnated board or extruded polystyrene foam sheets. The top of the joints must be lled nally with Dr. Fixit Pidiseal PS 42 P pouring grade sealant or Dr. Fixit PU Sealant.
1 Slab 2 Angle Fillet 3 Primer 4 Dr. Fixit Solyseal (2 coats) 5 Geotextile 6 Screed 7 Drip mould

MRW 15

Check to ensure that metal roof is properly tted with screws and fasteners Replace all of the vents on the roof, never leave anything on the roof that could cause a problem. Gaps if any between the sheets shall be lled using Dr. Fixit PU Sealant. Clean the surface well to remove dirt, dust, grease etc. Installation Whenever Dr. Fixit Flexshield T45/T60 membrane is being installed it is highly recommended that the membrane shall be laid at the position and allowed to relax for at least 45 minutes. This will help releasing the tensions in the membrane. Install insulation boards over the entire roof; to attain a smooth surface to lay Dr. Fixit Flexshield T45/T60 roong on metal roof. The insulation is fastened with epoxy coated screws and insulation fastening plates; the plates give more surface area to the screw head and securely fasten the insulation to the roof deck. Dr. Fixit Flexshield T45/T60 membrane is secured with the same epoxy coated screws and smaller seam fastening plates.

Each successive course of Dr. Fixit Flexshield T45/T60 membrane overlaps area about 150 mm where the fasteners hold the membrane in place. Hand held hot air welding machine is used to safely heat the membrane to bond all of the seams and ashings. The welds are as strong as the material itself and they require no adhesive or maintenance. The seam in the Dr. Fixit Flexshield T45/T60 roof membrane is also welded. The membrane is fastened at the walls with the same seam plates and screws. Dr. Fixit Flexshield T45/T60 must be secured with screws and plates at any angle change or transition. The screws and plates at the wall are covered with another layer of Dr. Fixit Flexshield T45/T60 membrane, this ashing covers the parapet dividing wall and waterproofs the perimeter of the roof The Dr. Fixit Flexshield T45/T60 wall ashing is then welded to the roof deck membrane

Dr. Fixit Solyseal


Polymer modied elastomeric bituminous coating

Dr. Fixit Pidiseal PS 42P


Two-part polysulphide sealant

Dr. Fixit Bathseal Tape


Leak-proof sealing tape for pipe wrapping

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit PU Sealant


One part non-sag polyurethane sealant

Dr. Fixit Flexshield T45/T60


Extremely tough and exible waterproong membrane
27

Terrace waterproong with heat insulation


WAterprOOfing And heAt insulAtiOn sYstem fOr the flAt rOOfs DR. FIXIT EXTENSA, DR. FIXIT FOAMsHIELd & DR. FIXIT NEWCOAT

System Life Expectancy of 25 years

Highly energy efcient, extremely lightweight, high end waterproong and insulating system

Terrace waterproong with heat resistant coating


WAterprOOfing cum heAt reductiOn sYstem DR. FIXIT NEWCOAT, DR. FIXIT HEATsHIELd

System Life Expectancy of 10 years

Energy saving, heat resistant coating and waterproong coating system

IFRI 25
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming Priming generally not required on concrete substrates for Dr. Fixit Extensa. Application Spray apply liquid, protective waterproong coating, Dr. Fixit Extensa, over the entire slab area with a designated pump. It will act as a tough and excellent waterproong barrier for the subsequent coat of Dr. Fixit Foamshield Then spray apply polyurethane foam Dr. Fixit Foamshield, of average thickness 35 to 45 mm with a density of 50 kg per cu.m. approximately. This will harden for subsequent application over it. Brush apply protective acrylic waterproong coating, Dr. Fixit Newcoat, over the entire PU Foam spread area, at approximately 300 microns DFT. Loosely lay geotextile fabric of 120 gsm, with overlap of 30 cm., after Dr. Fixit Newcoat dries Fix ridges in panels (area larger than 10 sq.m. & slope of 1 in 100 or 1 in 80), using bitumen impregnated boards & cement sand mortar. Lay or cast screed of concrete in M 20 in slope in 1: 100. Average thickness of screed is 75 to 100 mm. The ridges of bitumen impregnated boards or polyboard will act as construction joints. Using the grinding wheel, expose the joints and form grooves. Fix backing rod & apply elastomeric polysulphide sealant, Dr. Fixit Pidiseal PS 42P in all grooves of the construction joints in the concrete screed Fix angle llets in concrete along the parapet, mechanical duct openings & pre-utility up stands. Apply a nal coat of Dr. Fixit Newcoat of 300 micron DFT over the concrete screed & angle llets (50 mm height) as a sealer coat, up to the ashing.
1 Slab 2 Dr. Fixit Extensa 3 Dr. Fixit Foamshield 4 Dr. Fixit Newcoat 5 Geotextile 6 Screed 7 Angle Fillet 8 Dr. Fixit Newcoat 9 Drip mould

Methodology
Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Provide angle llets in cement mortar admixed with Dr. Fixit Pidicrete URP, of 50 mm x 50 mm all along the junction of the parapet wall & the roof slab. Priming Apply Dr. Fixit Primeseal to a clean, smooth surface by brush or roller. Allow the primer to dry prior to the application of Dr. Fixit Newcoat. During application of Dr. Fixit Primeseal always maintain the saturated surface dry condition. Application Apply 1 st coat of Dr. Fixit Newcoat and while it is still wet lay an open woven 2.5 x 2.5 mm glass bre mesh and allow it to soak completely.
8 7 6 5 4

IFRI 10

Apply 3rd coat of Dr. Fixit Newcoat. Allow it to dr.y completely. Ensure that the coating is extended up to 300 mm on vertical walls covering the angle llets completely. Apply 1 st coat of Dr. Fixit Heatshield over the Dr. Fixit Newcoat and allow it to dr.y for 6-8 hrs Apply 2nd coat of Dr. Fixit Heatshield and allow it to dry.

1 Concrete Slab 2 Screed 3 Angle Fillet 4 Dr. Fixit Primeseal 5 Dr. Fixit Newcoat - 1st coat 6 Open woven glass fibre mesh 7 Dr. Fixit Newcoat - 2nd & 3rd coat 8 Dr. Fixit Heatshield (2 coats) 9 Drip mould

9 7 8 6 5 4 3 2 1

Immediately apply 2nd coat of Dr. Fixit Newcoat to embed the mesh in coating. Allow it to dry completely. Ensure that the coating is extended up to 300 mm on vertical walls covering the angle llets completely.

2 1

Dr. Fixit Extensa


Highly elastomeric and puncture resistant waterproong coating

Dr. Fixit Newcoat


Heavy duty reinforced acrylic waterproong coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Newcoat


Heavy duty reinforced acrylic waterproong coating

Dr. Fixit Heatshield


Heat resistant exterior coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
29

Roof Gardens
System Life Expectancy of 25 years
TerrAce gArden wAterprOOfing DR. FIXIT EXTEnsA, DR. FIXIT FOAMSHIELD And DR. FIXIT TORCHSHIELD AR

High performance premium waterproong and heat insulation system for garden roofs

Methodology
Surface Preparation All surfaces must be cleaned with compressed air, free of loose materials, oils and other contaminants. Priming Priming generally not required on concrete substrates. Application Spray apply Dr. Fixit Extensa to achieve minimum thickness of 1.5 mm. It will act as a tough and excellent vapour barrier for the subsequent layer of Dr. Fixit Foamshield Dr. Fixit Extensa is applied through compatible equipment only. It cannot be sprayed through other types of commonly available sprayers. Dr. Fixit Extensa sets in few seconds. Spray- apply polyurethane foam Dr. Fixit Foamshield, of average thickness 35 to 45 mm with density 50 kg per cu. m. Spray apply Dr. Fixit Extensa to achieve minimum thickness of 1.5 mm over the Dr. Fixit Foamshield. A geotextile fabric of 120 gsm shall be placed over the membrane with about 300 mm overlaps before laying the concrete screed of minimum 50 mm thick mixed with Dr. Fixit Pidiproof LW+ with 1:100 slope properly aligned with drain outlets for efcient drainage of water. Make angle llets all around the periphery of the terrace wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. For extensive roof gardens, after application of Dr. Fixit Torchshield Primer and Drying of same, torch-apply Dr. Fixit Torchshield AR (anti-root membrane) on the screed. Place a drainage board as specied over the concrete screed. Place a loosely laid geotextile fabric of 150 gsm again, over the entire drainage board to contain the soil. Place soil for vegetation accordingly.
1 Slab 2 Angle Fillet 3 Dr. Fixit Extensa 4 Dr. Fixit Foamshield 5 Geotextile 6 Screed 7 Dr. Fixit Torchshield Primer 8 Dr. Fixit Torchshield AR 4160 9 Soil
10 Vegetation 11 Gravel 12 Drip mould

RGW 25

Roof Gardens

11 10 9 8 7 6 5 4 3 2 12

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Extensa


Highly elastomeric and puncture resistant waterproong coating
31

Roof Garden
System Life Expectancy of 15 years
TerrAce gArden wAterprOOfing

Reliable, lightweight waterproong system for roof garden

DR. FIXIT TORCHsHIELd AP 4160

Methodology
Surface Preparation All surfaces must be cleaned with compressed air, free of loose materials, oils and other contaminants. Make angle llets all around the periphery of the podium wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. Priming Apply Dr. Fixit Torchshield Primer with a roller or brush. Allow the primer to dry for 8 to 10 hrs. Application Start the application of a rst layer of Dr. Fixit Torchshield AP 4160 (plain nish APP based) The application must start from the outlet, going towards the centre of the roof area. This 1 st layer is laid, up to over the angle llet only. The 2 layer of Dr. Fixit Torchshield AP 4160 must be laid in a perpendicular direction to the 1 st membrane, starting from 15 to 20 mm on the parapet wall, downward and covering the angle llet.
nd

RGW 15

Methodology

For extensive roof gardens, after application of Dr. Fixit Torchshield Primer and Dr.ying of same, torch-apply Dr. Fixit Torchshield AR (anti-root membrane) on the screed. Place drainage board as needed over the concrete screed. Place a loosely laid geotextile fabric of 150 gsm again, over the entire drainage board to contain the soil. Place soil for vegetation accordingly.

5 Geotextile 6 Screed 7 Dr. Fixit Torchshield AR 4160 8 HDPE drain board 9 Soil
10 Vegetation 11 Gravel 12 Drip mould

9 8 7 6 5 4 3 2 12 11 10

Dr. Fixit Torchshield


APP / SBS modied bitumen based membrane

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
33

Wet areas

A geotextile fabric of 120 gsm shall be placed over the membrane with about 300 mm overlaps before laying the screed of 75 mm average mixed with Dr. Fixit Pidiproof LW+ with 1:100 slope properly aligned with drain outlets for efcient drainage of water.

1 Slab 2 Angle Fillet 3 Dr. Fixit Torchshield Primer 4 Dr. Fixit Torchshield AP 4160

Wet areas
System Life Expectancy of 15 years
Wet AreA wAterprOOfing sYstem

New water tanks


Comprehensive system for 100% leak free bathroom
WAterprOOfing Of new wAter tAnKs

System Life Expectancy of 7 years

Tough and exible waterproong coating system

DR. FIXIT BATHsEAL RAnGE Of pROduCTs

DR. FIXIT FAsTfLEX

Methodology
Surface Preparation All surfaces must be pressure washed or clean with compressed air, then allowed to dry, free of loose materials, oils, form release agents and other contaminants. Make angle llets all around the periphery of the wall with polymer modied mortar prepared with Dr. Fixit Pidicrete URP. The gaps around the pipe inserts and the oor traps etc., shall not be wider than 50 mm. Application The sanitary pipes entering through the walls and oor to be sealed with Dr. Fixit Bathseal Tape and the gaps to be grouted with Dr. Fixit Bathseal Grout, a non shrink cementitious grout. The Nahani trap, etc., to be tted securely in the same manner and the gaps around it to be grouted. Now start applying the 1 st coat of Dr. Fixit Bathseal 2K in the sunken area and extend up to 150 mm on walls and above the nished oor level (FFL). Extend the coating in shower ash zone -1500 mm wide x 1800 mm high. While this rst coat of Dr. Fixit Bathseal 2K is still wet cover all angle llets with 150 mm wide strip of open woven glass bre mesh of 2 mm X 2 mm immediately over the coating and allow it to soak completely. Cover it with one additional coat of Dr. Fixit Bathseal 2K over the angle llets and allow it to dry completely. Apply 2nd coat of Dr. Fixit Bathseal 2K after the rst coat dries completely. Also cover the angle llets during the second coat application. 24 to 72 hrs after, the sunken portion must be laid with a concrete screed of 50 mm thickness. Sanitary pipes and traps can be laid over this screed, the next day. Brickbat coba using Dr. Fixit Pidiproof LW+ can be laid 24 hrs later to x these pipes in position. After nalising the plumbing work in the bathroom oor & wall, tiling work can start using the Roff Tiling Adhesives & RTM Tile grouts. After nishing all works the sanitary ware can be tted and the gaps around it shall be lled with Dr. Fixit Bathseal Sealant to complete the bathroom waterproong. ALTERNATIVELY Dr. Fixit Bathseal Plus shall be applied as a high performance premium bathroom waterproong system in place of Dr. Fixit Bathseal 2K .
4

WW 15

Methodology
During the construction of the water tank a swellable, adhesive strip waterbar of 20 mm X 20 mm, Dr. Fixit Waterbar SW 2020 shall be provided in the construction joints, which is placed on the inside of the reinforcement, in both the raft concrete oor (in case of ground water tank) & the side retaining concrete walls. All water pipe ttings to be wrapped up with Dr. Fixit Bathseal Tape and to be grouted with Dr. Fixit Pidigrout 5M, non shrink, free-ow cementitious grout to ensure leak free, water tight joint. Form 50 x 50 mm angle llet on all wall to ooring joints, by adding Dr. Fixit Pidicrete URP. Application On the vertical areas, apply additional 3rd coat of Dr. Fixit Fastex and while it is wet, sprinkle washed and cleaned coarse sand liberally all over the vertical areas. This will provide a key to the subsequent plaster application (12-15 mm). Test the area with water ponding and rell to start using the tank after 3-4 days of complete curing for 48 hours to ensure there is no leak. Drain the water. Lay 50 mm thick concrete screed (with 10 mm aggregate) mixed with polypropylene bers (500 gms per cubic meter) on the horizontal surface of the water tank.
1 Angle Fillet 2 Dr. Fixit Waterbar SW2020 3 Screed 4 Dr. Fixit Fastex (2 coats) 5 Dr. Fixit Fastex with sprinkled sand 6 Plaster

WWT 7

1 Concrete slab 2 Angle llet 3 Dr. Fixit Bathseal 2K (2 coats) 4 Glass bre mesh 5 Concrete screed 6 Brickbat coba 7 Dr. Fixit Bathseal Tape 8 Dr. Fixit Bathseal Grout 9 Roff tiling adhesive & tile grout
10 Dr. Fixit Bathseal 2K (2 coats)

7 Dr. Fixit Bathseal Tape & Dr. Fixit Pidigrout 5M 8 Intake Pipe

8 7

10

Apply Dr. Fixit Fastex over the entire internal area in a saturated surface dry condition. While this rst coat of Dr. Fixit Fastex is still wet cover all angle llets with 150 mm wide reinforcing strip of open woven glass bre mesh of 2 mm X 2 mm immediately over the coating and allow it to soak completely. Cover it with one additional coat of Dr. Fixit Fastex over the angle llets and allow it to dry completely. Apply 2nd coat of Dr. Fixit Fastex after the rst coat dries completely. Also cover the angle llets during the second coat application. Allow it to dry completely for 6-8 hrs.

6 5 4 3 2 1

9 8 7 6 5 3 2 1

Dr. Fixit Bathseal Kit


One stop solution for 100% leak free bathroom

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

ROFF Rainbow Tile Mate


Unsanded cement based tile joint ller

Dr. Fixit Pidigrout 5M


High strength, non-shrink, free ow grout for foundations

Dr. Fixit Bathseal Tape


Leak-proof sealing tape for pipe wrapping

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Fastex


High performance polymer modied cementitious coating
35

External walls
EXternAl wAlls wAterprOOf cOAting

Manholes
System Life Expectancy of 5 years

High performance elastomeric waterproof coating for leak-free exterior walls

MAnhOle wAterprOOfing

System Life Expectancy of 10 years

Protection to buried concrete in adverse environment

DR. FIXIT RAInCOAT WITH DR. FIXIT PRIMEsEAL

DR. FIXIT SAMsHIELd XL 1500 & DR. FIXIT COAL TAR EpOXY

EWWP 5
Surface Preparation Ensure complete surface preparation prior to application. Remove all loose dirt, dust and oil, etc., from the surface. Check for all surface cracks and clean them to remove all loose laitance & wash with water Apply crack-ller, Dr. Fixit Crack-X Paste/ Shrinkfree depending upon the width of crack (use paste for cracks up to 3-5 mm and Shrinkfree for cracks up to 10 mm) with a putty blade properly by pressing the material in cracks. The loose and loose plaster shall be removed and re-done using polymer modied mortar modied with Dr. Fixit Pidicrete URP. Priming Prime the surface with Dr. Fixit Primeseal diluted 2:1 with water maintaining the saturated surface dry condition. Allow to dry completely.

Methodology
EXTERnaL SURFaCE OF ManHOLE Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming Apply Dr. Fixit Torchshield Primer to a clean, smooth and dry surface by brush or roller. Allow the primer to dry prior to the application of the membrane. Application 4 mm bituminous protection board / geotextile membrane shall be placed over it for protection against damage in case the land lling contains heavy boulders etc. which may damage the membrane. Dr. Fixit Samshield XL 1500 to be used for external surface & Dr. Fixit Coal Tar Epoxy for internal surface. Alternatively Dr. Fixit Coal Tar Epoxy can be used for both external & internal surfaces. InTERnaL SURFaCE OF ManHOLE Surface Preparation The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed and repaired with polymer modied mortar using Dr. Fixit Pidicrete URP. Priming

MHWP 10

1 Spalled plaster 2 Exposed brick masonry 3 Plaster reinstated using PMM


mixed with Dr. Fixit Pidicrete URP

Since Dr. Fixit Coal Tar Epoxy is self priming there is no need for special primer. Application Apply 1 st coat of Dr. Fixit Coal Tar Epoxy and allow it to dry completely for 12 to 15 hrs depending upon the site conditions. Apply 2nd coat of Dr. Fixit Coal Tar Epoxy and allow it to dry completely. The manhole shall be made operational after 4-7 days after full curing of Dr. Fixit Coal Tar Epoxy internally.

Application Apply 1 st coat of Dr. Fixit Raincoat without dilution maintaining the spreading rate. Allow to dry for 6-8 hrs Apply 2nd coat in direction perpendicular to 1 st coat ensuring complete covering of the area.

4 Column 5 Separation joint lled using PMM


Dr. Fixit Pidicrete URP

6 Plaster cracks lled with


Dr. Fixit Crack-X Shrinkfreee

7 Primer coat of Dr. Fixit Primeseal 8 Separation joint RCC-Masonry 9 2 coats of Dr. Fixit Raincoat
10 Beam

10 9 8 7 6

It is very important to cut the membrane in specic size as per the manhole design from external side before execution of job. Apply Dr. Fixit Samshield XL 1500 self adhesive SBS modied membrane by removing the silicon releasing paper on the primed surface. Dr. Fixit Samshield XL 1500 membrane shall then be applied on top of the exposed tape overlapping by 100 mm. The subsequent membrane will then be overlapped with other 100 mm of tape.

5 4 3 2 1

Dr. Fixit Raincoat


Acrylic Elastomeric Exterior Waterproof Coating

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Primeseal


Eforescence resistant penetrative primer

Dr. Fixit Crack-X Shrinkfree


100 % shrinkfree crack ller

Dr. Fixit Samshield


Self adhesive bituminous membrane

Dr. Fixit Coal Tar Epoxy


Two-component coal tar epoxy coating for concrete surface

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
37

Remedial treatment for existing roof


RemediAl treAtment fOr eXisting rOOf DR. FIXIT NEWCOAT

System Life Expectancy of 7 years

Excellent repairing system for existing roof with brickbat coba

Methodology
Surface Preparation Cut open and clean cracks in the existing screed or brick bat coba systems with compressed air. Repair these cracks with polymer modied mortar modied with Dr. Fixit Pidicrete URP. The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections, protrusions, structurally unsound and loose concrete must be removed. Prime the surface with Dr. Fixit Primeseal and allow it to dry. Apply the 1 st coat of Dr. Fixit Newcoat. While it is still wet, place a woven glass bre mesh of 2 mm X 2 mm size and allow it to soak completely. Immediately apply the 2nd coat with a roller or squeegee, to ensure complete coverage of the bre mesh. Apply the 3 coat after 6 to 8 hrs, after the 2nd coat dries.
rd

EFR 7

1 Concrete slab 2 Angle Fillet 3 Brickbat coba 4 Dr. Fixit Primeseal 5 1st coat Dr. Fixit Newcoat 6 Open woven glass bre mesh 7 2nd coat of Dr. Fixit Newcoat 8 3rd coat of Dr. Fixit Newcoat 9 Drip mould

Remedial

Waterproong

9 8 7 6 5 1 4 3 2

Dr. Fixit Newcoat


Heavy duty reinforced acrylic waterproong coating

Dr. Fixit Primeseal


Eforescence resistant penetrative primer

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
39

Remedial Waterproong Systems


The ultimate remedial system for leaking basements
RemediAl wAterprOOfing fOr A leAKing bAsement

DR. FIXIT PU FOAM InJECTIOn And DR. FIXIT PLAIn InJECTIOn

Methodology
Preliminary Preparation Assess the problem area & suitably mark the spots for drilling grouting holes. If the intensity of running water is high & cannot be controlled, then divert the ow of water using a PVC pipe at the spot of leak. For heavy dripping, mark the spots in a grid pattern 150 mm centre-centre or in case of spot dripping drill at the point of leakage at an angle of 45o to the plane of grouting. Drill diameter for a hole should be corresponding to the packers in use (generally 16 mm - 20 mm) & depth of the hole drilled to be 100 mm deep or generally half the thickness of the substrate. Fix alloy packers (non-return type) of dimension 14 mm x 80 mm with a suitable putty. Allow the putty to cure for 24 hrs prior to commencing the injection grouting process. Application Mix base & hardener in the specied proportions: Dr. Fixit PU Foam Injection - 10 parts of base : 1 part of hardener The mixing to be carried out in a completely dry container using a stirrer. After rinsing the pump using a PU Cleaner, ll the PU mixture into the pumping container & initiate pumping on a low pressure & gradually build up the pumping pressure suitably Stop pumping if back pressure is sensed or if the grout has oozed out of the adjoining hole. PU foam injection oozes out of the grouting hole & hardens primarily in 10-15 minutes. Complete curing of the PU foam will happen over a period of 24 hrs. Mix base & hardener in the specied proportions: Dr. Fixit PU Plain Injection - (2 parts of base: 1 part of hardener) Dr. Fixit PU Plain Injection, resin injection to be pumped once the PU foam has set in a similar manner as that of foam. This will act as a secondary injection thus completely sealing the leaking cavity. Cut off the extended portion of the packer & seal the surface with suitable putty. Choice of PU injection grout, Foam/Plain depends on the condition of the substrate & severity of leakage Injection grouting for dampness using Pagel ZS 10 Drill grouting holes at an angle of 45 on the wall adjacent to the area of leakage at a spacing of 500 mm centre to centre or less in a grid pattern. Fix PVC or MS nozzles (packers) in the grouting holes using Dr. Fixit Instant Leak Plug or epoxy putty. Allow the nozzle to set for 24 hrs. Add water at a ratio of 0.34-0.45 to prepacked cementitious grout Pagel ZS 10 mix to a uniform consistency using a mixing paddle. Using a grouting pump, inject Pagel ZS 10 through the nozzle at required pressure. Grouting should commence from the lowest possible level & proceed upwards along the grid with the pumping pressure increased gradually.

LFB
1 Dr. Fixit Krystalline 2 Packers 3 Structural cracks strengthening 4 Injection grouting along
5
construction joint

Wire brush the surface to remove existing paint & putty so as to expose the plastered surface. Ensure complete crack-lling as recommended & wet the surface prior to over-coating. Brush apply 2 coats of damp-proof coating Dr. Fixit Krystalline over the plastered surface. Time duration between two coats to be 4 hrs approx. Air cure for 24 hrs prior to over-coating with decorative paint. Dr. Fixit Krystalline mixed with water (5:1) can also be used as a Sealing-Putty.

5 Injection grouting along cracks


4 2 3

Continue pumping until the grout ows out from adjacent nozzle. Detach the pump & nozzle and seal the grouting hole with Dr. Fixit Instant Leak Plug. Re-instating of spalling plaster in oor/wall & sealing construction joint Chip off the damaged portion to obtain a sound surface with straight edges. Wash the area with water & apply 1 primer coat of Dr. Fixit Pidicrete URP (1:1 with cement) Prepare polymer modied mortar using Dr. Fixit Pidicrete URP (10-12%) on weight of cement. (cement :washed sand in 1:3) adjusting appropriate consistency as per water demand & apply while the primer is tacky. Allow the repaired patch to cure adequately Damp-proof coating of wall/oor In case of continuous ow of water from a certain spot use Dr. Fixit Instant Leak Plug to seal it prior to the application of Dr. Fixit Krystalline on the damp patches. Ensure complete surface preparation prior to application

Dr. Fixit PU Foam Injection


Two-component PU foam injection

Dr. Fixit Krystalline


Cementitious crystalline waterproof coating

Dr. Fixit PU Injection


Two-component plain injection

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Pagel ZS10
Pre-packed micro-ne cementitious injection grout

Dr. Fixit Instant Leak Plug


Fast setting powder for drip leakages
41

Rising Dampness
Remedial solution for rising dampness

Repair to old roofs with bituminous treatments

Cold applied exible bitumen system for re-roong after the removal of old bituminous treatments.

DR. FIXIT dAMpfREE

DR. FIXIT SOLYsEAL

Methodology
Surface Preparation Remove Paint up to bare masonry surface from affected area by wire-brushing or other suitable means. Wipe surface with wet cloth to remove loose particles from Cement Plaster. Fixing of nozzles Drill holes with 12 - 15 mm bit at 45 angle, penetrating width of the wall. Starting from skirting level with 300 mm distance between each hole horizontally and 300 mm to 400 mm vertically from ground level, from centre to centre. A zigzag pattern to be formed to cover the entire area to be injected for effective result. Fix the perforated PVC nozzles and seal them secure with Dr Fixit Instant Leak Plug and allow to set for one day before starting work. Use grouting pump with minimum 2 Bar (2 kg / cm2) pressure capacity to pump the Dr Fixit Dampfree in wall. Dilution of Dr. Fixit Dampfree depends upon the severity of problem, from 1 :1 to 1:5 with clean water. Injecting Dr. Fixit Dampfree Inject diluted Dr. Fixit Dampfree through the nozzles till the back pressure is felt. Move to next nozzle and complete the process by injecting through all xed nozzles in the affected area. Then cut off the nozzles at the surface level and seal the holes using PMM modied with Dr. Fixit Pidicrete URP. Level the surface with plaster and allow the surface to dry completely before proceeding for painting.

RD
Surface Preparation Surface must be clean and free from dirt, dust, grease, oil, etc. Remove old paint /damp wall with blisters/paint peel/loose particles etc. by wire-brushing or other suitable means up to bare masonry surface. Repairs shall be carried out using polymer modied mortar modied with Dr. Fixit Pidicrete URP. Priming Prime the surface with Dr. Fixit Solyseal diluting with water in 1:1 ratio evenly and allow it to dry completely. Application Apply rst coat of Dr. Fixit Solyseal. While the rst coat is still wet, embed a layer of fabric mesh reinforcement. Brush or roll over the embed mesh at right angles to the 1 st layer of Dr. Fixit Solyseal to ensure that the mesh is fully covered. Take care that the mesh is overlapped at least 50 mm at edges and by 100 mm at ends. Apply second coat of Dr. Fixit Solyseal and allow it to dry completely. Apply one more coat of Dr. Fixit Solyseal as top coat and allow it to dry. Lay 50 mm thick sand cement protection screed with proper slope for efcient draining of rain water. Provide control joints in the screed to avoid crazing and cracking of the screed. Fill joints with polysulphide sealant Dr. Fixit Pidiseal PS 42 P or Dr. Fixit PU sealant.

EFR

Dr. Fixit Dampfree


Silicone injection for rising dampness

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs

Dr. Fixit Solyseal


Polymer modied elastomeric bituminous coating

Dr. Fixit PU Sealant


One part non-sag polyurethane sealant

Dr. Fixit Pidiseal PS 42P


Two-part Polysulphide Sealant

Dr. Fixit Pidicrete URP


SBR Latex for waterproong & repairs
43

General construction & secondary waterproong


Solutions for enabling healthy construction

Methodology
1. Making general concrete & masonry waterproof
}} }} }} }}

GC&SW
3. Effective Curing of Concrete.
}}

Waterproong of concrete and mortar Increases strength Resists corrosion Increases workability
}} }}

New technology as per ASTM C 1315 for curing compounds which does not allow water & moisture to escape. Useful in areas where there is scarcity of water. Will act as a primer for subsequent nishes.

5. Minor repairs in new construction, voids, cracks, tie rod holes etc.
}}

7. Expansion joints
}}

9. Honeycombing in concrete structures


}}

Accommodate movements in the structure

To achieve leveled crack free surface

To get a defect free durable concrete

Methodology Prepare the joint, prime with Dr. Fixit Pidiprime A . After Dr.ying the primer use backer rod and ll joint with Dr. Fixit Pidiseal PS 42 P for horizontal joints by pouring and Dr. Fixit Pidiseal PS 41 G for vertical joints by application with gun. The width to depth ratio should be 2:1. The recommended joint sizes are 40 mm x 20 mm or 25 mm x 12.5 mm. In any case width of the joint shall not exceed 50 mm. 8. Bonding during structural repairs
}}

Methodology Ensure that all loose material is mechanically removed / blown out. Maintain the surface in saturated surface dry condition. Fill crevices / honeycombs with Dr. Fixit Fairing Mortar with a trowel to level the surface. Where honeycombs in concrete are to a large extent, resort to repairing with Dr. Fixit Micro-concrete

Methodology Small crevices or voids in new concrete shall be lled up by Dr. Fixit Fairing Mortar, a pre-packed single part cementitious material, which gives an excellent crack free, non-shrink nish to the concrete surface Tie rod holes to be lled up with polymer modied mortar using Dr. Fixit Pidicrete URP. it will provide a non-shrinking, crack-free surface to concrete. In RCC, the minor cracks to be treated with polymer modied mortar modied with Dr. Fixit Pidicrete URP. 6. Cold construction Joints
}}

Methodology Add 200 ml Dr. Fixit Pidiproof LW+ for a 50 kg bag of cement used in the mix design of concrete or mortar Do not add directly in dry mix. Add Dr. Fixit Pidiproof LW+ dispersed in the gauging water. Add this water at the end during the mixing process. 2. For easy removal of formwork
}}

Methodology Apply Dr. Fixit Curing Compound with a spray, roller or brush over the entire concrete surface immediately after de-shuttering. 4. Prevent leakage from separation gaps arising between RCC members and masonry
}} }}

Avoids dampness due to ingress of water. Crack free due to high exibility of mortar.

Avoids staining of concrete as observed in case of burnt oils Good for subsequent nishes over concrete

Excellent adhesion to almost all building materials. Very high durable bond.

Methodology Make a U groove, and blow off all laitance and loose material. Apply a polymer modied mortar in saturated surface dry condition, prepared with Dr. Fixit Pidicrete URP, (10-12%) by weight of cement (cement:washed sand in 1:3) adjusting appropriate consistency as per water demand. Cure by sprinkling water 3-4 times a day for 2 days.

Leak free joints

}}

}}

Methodology Dr. Fixit Waterbar SW 2020 to be placed between the two rows / columns of the reinforcement bars, vertically as well as horizontally while resuming concreting at cold construction joints.

Methodology Brush apply mixed material of Dr. Fixit Epoxy Bonding Agent over the prepared surface. While the coating is still tacky place the concrete or repair material.

Methodology Directly apply with a mop/brush - Dr. Fixit Deshuttering Oil over plywood or steel formwork. After application allow to dry and do not wash with water. Not recommended for timber shuttering.

Dr. Fixit Pidiproof LW+


Integral liquid waterproong compound for plaster and concrete

Dr. Fixit Waterbar


Flexible adhesive waterstop strip

Dr. Fixit Fairing Mortar


Single component ready to use fairing mortar

Dr. Fixit Deshuttering Oil


Water dilutable shuttering /mould release agent

Dr. Fixit Pidiseal PS 42 P


Two-part Polysulphide sealant

Dr. Fixit Pidiseal PS 41 G


Two-part Polysulphide sealant

Dr. Fixit Epoxy Bonding Agent


2-part solvent free epoxy bonding agent

Dr. Fixit Micro-concrete


Flowable mortar for repair to damaged reinforced concrete membrane

45

Typical Expansion Joint Details at the roof level

Methodology
Typical Expansion Joint Details in Roofs Clean the substrate with broom brush or compressed air. Construct a Masonry upstand to a minimum height of 250 mm. Form 50 x 50 mm triangle llet on all vertical upstands. The llet should be prepared in concrete admixed with 10 to 15 % of Dr. Fixit Pidicrete URP, by weight of cement. Apply the Dr. Fixit Waterproong System as selected waterproong for the area the up stand area, depending upon the type of roof, etc. The treatment should always be taken up over these angle llets. All vertical upstands will be terminated as per standard termination details. Seal the expansion joint with ller board, with a backer rod of closed cell polyethylene foam or of extruded polystyrene, inserted. Fill the joint with selected sealant. Place expansion joint cover over the joint as shown in the drawing, in such a way that water will drain off on to the roof. Seal horizontal joints with a seal tape.
1 1 Roof Deck 2 Upstand 3 Expansion Joint Cover 1 Vertical Upstand 2 Aluminium joint cover

TDW

3 2

1 1

Typical Extension Joint Detail

Typical Vertical Termination Detail for Liquid applied Membranes.

Typical Extension Joint Details Clean the substrate with broom brush or compressed air. Construct Masonry Upstand to a minimum height of 250 mm. Form 50 x 50 mm triangle llet on all vertical up stands. Apply Dr. Fixit selected waterproong system over the up stand area. All vertical upstands will be terminated as per standard termination details. Seal the expansion joint with ller board. Insert backer road. Fill the joint with selected sealant. Place expansion joint cover over the joint as shown in the drawing. Seal horizontal joints with seal tape.

Dr. Fixit Torchshield Membrane

2 Aluminium Flashing 3 Sealant

1 Dr. Fixit Liquid Membranes 2 Plaster terminated at 250 mm height 3 Parapet Wall Substrate

3 2 1 3

Pidilite Industries Limited


Construction Chemicals Division Ramkrishna Mandir Road, Post Box No. 17411, Andheri (E) Mumbai 400059 INDIA Tel +91-22-2835 7000 Fax +91-22-2835 7008 www.doctor-xit.com drxitadvice@pilmail.com

For Expert and Technical advice call 1800

3002 5502
12CC1237-ACEBK-ENG-09/12

CONTACT US: Ahmedabad (079) 27552043/ 1483 Bengaluru (080) 30563000/3001 Chennai (044) 28350338/ 1614 Delhi (011) 45529000 Hyderabad (040) 23351250/ 1308 Kochi (0484) 2543978, 3045000 Kolkata (033) 22888844 Mumbai (022) 2835 7000 OVERSEAS CONTACTS: Dubai +9714 3471678 Singapore +65 67638681 Thailand +66 27228535
DISCLAIMER The product information & application details given by the company & its agents has been provided in good faith & meant to serve only as a general guideline during usage. Users are advised to carry out tests & take trials to ensure on the suitability of products meeting their requirement prior to full scale usage of our products. Since the correct identication of the problems, quality of other materials used and on-site workmanship are factors beyond our control, there are no expressed or implied guarantee/ warranty as to the results obtained. The Company does not assume any liability or any consequential damage for unsatisfactory results, arising from the use of our products.
Design Pidilite Design Studio

S-ar putea să vă placă și