Sunteți pe pagina 1din 6

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
Limited partnership Headquarters Mulfingen County court Stuttgart HRA 590344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 590142

Nominal data
Type Motor Phase Nominal voltage Frequency Type of data definition Valid for approval / standard Speed Power input Current draw Motor capacitor Capacitor voltage Max. back pressure Min. ambient temperature Max. ambient temperature min-1 W A F VDB Pa C C VAC Hz W4E500-GM03-01 M4E110-GF 1~ 230 50 ml CE 1300 680 3.0 12 450 150 -40 65 1~ 230 60 ml CE 1400 880 3.88 12 450 100 -40 40

ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations

Data according to ErP directive


Actual Request 2013 Request 2015

Installation category Efficiency category Variable speed drive Specific ratio*


*

A Static No 1.00

Overall efficiency es Efficiency grade N Power input Pe Air flow qv Pressure increase pfs Speed n kW m/h Pa min-1

32.5 40 0.65 5765 129 1315

28.5 36

32.5 40

Specific ratio = 1 + pfs / 100 000 Pa

Data established at point of optimum efficiency

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Technical features
Mass Size Surface of rotor Material of terminal box Material of blades Material of guard grille Number of blades Direction of air flow Direction of rotation Type of protection Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard Approval 18 kg 500 mm Coated in black PC/ABS plastic Bayblend FR110 Press-fitted sheet steel blank, sprayed with PP plastic Steel, phosphated and coated in black plastic 5 "V" Counter-clockwise, seen on rotor IP 54 "F" F4-1 + 80 C - 40 C Any On rotor and stator sides S1 Ball bearing <= 3.5 mA

Via terminal box, integrated capacitor connected via terminal box Thermal overload protector (TOP) brought out Axial I (if protective earth is connected by customer) EN 61800-5-1; CE GOST; VDE; UL 1004-1; CSA C22.2 Nr.100

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Product drawing

1 2 3 4

Direction of air flow "V" Tightening torque 0.80.15 Nm Shown without terminal box cover Cable diameter: min. 6 mm, max. 12 mm; tightening torque: 20.3 Nm

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Connection screen

L PE

= U1 = blue green / yellow

Z TOP

brown grey

= U2 = black

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Charts: Air flow 50 Hz


Druck p f s[Pa]fr Rho=1,2kg/m^3

190 185 180 175 170 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0

1.000

2.000

qv[cfm] 3.000

4.000

5.000

1.000

2.000

3.000

4.000

5.000 qv[m^3/h]

6.000

7.000

8.000

9.000

0,76 0,74 0,72 0,7 0,68 0,66 0,64 0,62 0,6 0,58 0,56 0,54 0,52 0,5 0,48 0,46 0,44 0,42 0,4 0,38 0,36 0,34 0,32 0,3 0,28 0,26 0,24 0,22 0,2 0,18 0,16 0,14 0,12 0,1 0,08 0,06 0,04 0,02 0

Measurement: LU-107128 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.

Measured values
U V 1 2 3 4 230 230 230 230 f Hz 50 50 50 50 n min-1 1380 1355 1330 1300 Pe W 513 571 623 680 I A 2.25 2.50 2.73 3.00 LpAin dB(A) 68 65 63 65 LwAin dB(A) 75 72 70 72 LwAout dB(A) 75 72 70 71 qv m3/h 8905 7930 6705 5140 pfs Pa 0 50 100 150

U = Supply voltage f = Frequency n = Speed Pe = Power input I = Current draw LpAin = Sound pressure level inlet side LwAin = Sound power level inlet side LwAout = Sound power level outlet side qv = Air flow pfs = Pressure increase

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

p fs_E[IN H2O]

p f s[Pa]

a] f s[P p

W4E500-GM03-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Charts: Air flow 60 Hz


Druck p f s[Pa]fr Rho=1,2kg/m^3

200 190 180

1.000

2.000

3.000

qv[cfm] 4.000

5.000

6.000

7.000

0,8 0,75 0,7

170 160 150 140 130 0,5 120


p fs_E[IN H2O]

Measurement: LU-107130 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.

0,65 0,6 0,55

110
p f s[Pa]

0,45

100 90 80 70 60 50 40 30

4
0,4

0,35 0,3 0,25 0,2

2
0,15 0,1

20 10 0 0,05 0 13.000

a] f s[P p

1.000

2.000

3.000

4.000

5.000

6.000 7.000 qv[m^3/h]

8.000

9.000

10.000 11.000

12.000

Measured values
U V 1 2 3 4 230 230 230 230 f Hz 60 60 60 60 n min-1 1530 1485 1450 1400 Pe W 793 828 853 880 I A 3.45 3.61 3.73 3.88 LpAin dB(A) 70 68 66 65 LwAin dB(A) 77 75 73 72 LwAout dB(A) 78 75 73 72 qv m3/h 9850 8990 8220 7300 pfs Pa 0 40 70 100

U = Supply voltage f = Frequency n = Speed Pe = Power input I = Current draw LpAin = Sound pressure level inlet side LwAin = Sound power level inlet side LwAout = Sound power level outlet side qv = Air flow pfs = Pressure increase

Item no. 10080-5-9980 Revision 71440 Release 2010-11-24 Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com