MS116-6.

3-HKF1-11
General Information
Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS116-6.3-HKF1-11 1SAM250005R1009 4013614394799 MS116-6.3-HKF1-11 Manual Motor Starter The MS116-6.3-HKF1-11 manual motor starter is a compact 45 mm width devices with a rated operational current of Ie = 6.3 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

Categories
Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters Products Low Voltage Products and Systems Control Products Manual Motor Starters Manual Motor Starters

Accessories Show accessory images Ordering


EAN: Minimum Order Quantity: Customs Tariff Number: 4013614394799 1 piece 85362010

Container Information
Package Level 1 Units: Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 2 Gross Weight: Package Level 2 EAN: 1 piece 92.0 mm 95.0 mm 50.0 mm 0.295 kg 40 piece 280.0 mm 395.0 mm 210.0 mm 12.186 kg 4013614408847

Dimensions
Product Net Width: Product Net Height: Product Net Depth: Product Net Weight: 45.0 mm 90.0 mm 85.6 mm 0.280 kg

Technical
Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC) 50 kA (400V AC) 50 kA (440V AC) 6 kA (500V AC) 6 kA (690V AC) 2 kA (230V AC) 50 kA (400V AC) 50 kA (440V AC) 6 kA (500V AC) 6 kA (690V AC) 2 kA 78.75 A 4.00 ... 6.30 A (400V) 2.2 kW Main Circuit 690 V AC 6.30 A 6.30 A Main Circuit 50 / 60 Hz Main Circuit 6 kV

Rated Ultimate Short-Circuit Breaking Capacity (Icu):

Rated Instantaneous Short-Circuit Current Setting (Ii): Setting Range: Rated Operational Power AC-3 (Pe): Rated Operational Voltage (Ue): Rated Operational Current (Ie): Rated Operational Current AC-3 (Ie): Rated Frequency (fr): Rated Impulse Withstand Voltage

(Uimp): Rated Insulation Voltage (Ui): Power Loss: Number of Poles: Mounted Auxiliary Contacts: Conventional Free-air Thermal Current (Ith): Isolating Function: Degree of Protection: Pollution Degree: Electrical Durability: Mechanical Durability ( ): Connecting Capacity-Main Circuit:

690 V Per Pole 0.7 ... 1.7 W 3 1 NO, 1 NC Main Circuit 6.30 A Yes IP20 3 100000 cycle 100000 cycle Rigid 1/2x 1 ... 4 mm Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm Flexible 1/2x 0.75 ... 2.5 mm Rigid 1/2x 1 ... 1.5 mm Flexible with Ferrule 1/2x 0.75 ... 1.5 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm Flexible 1/2x 0.75 ... 1.5 mm Main Circuit 0.8 1.2 Nm Auxiliary Circuit 0.8 1.2 Nm Main Circuit 9 mm Auxiliary Circuit 8 mm Pozidriv 2 / M3.5 Position 1 to 6 Rotary Handle ON / OFF TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1

Connecting Capacity-Auxiliary Circuit: Tightening Torques: Wire Stripping Length: Recommended Screw Driver: Mounting Position: Actuator Type: Contact Position Indication: Mounting on DIN Rail: Standards:

Environmental
Ambient Air Temperature: Operation -25 . +70 C Operation Compensated -25 ... +55 C Storage -50 +80 C Around the Enclosure 0 ... +40 C Yes 2000 m 11 ms Pulse 250 m/s 5g / 3 150 Hz Following EU Directive 2002/95/EC August 18, 2005 and amendment

Ambient Air Temperature Compensation: Maximum Operating Altitude Permissible: Resistance to Shock acc. to IEC 60068-2-27: Resistance to Vibrations acc. to IEC 60068-2-6: RoHS Status:

Technical UL/CSA
Maximum Operating Voltage UL/CSA: Horse Power Rating UL/CSA: Ampere Rating UL/CSA: General Use Rating UL/CSA: Connecting Capacity-Main Circuit UL/CSA: Connecting Capacity-Auxiliary Circuit UL/CSA: Tightening Torques UL/CSA: Contact Rating UL/CSA: Main Circuit 600 V AC Auxiliary Circuit 250 V AC/DC 220 ... 240V AC Three Phase 1.5 Hp 440 ... 480V AC Three Phase 3 Hp 550 ... 600V AC Three Phase 5 Hp 6.30 A 600V AC 6.30 A Stranded 1/2x 16 ... 12 AWG Flexible 1/2x 16 ... 12 AWG Stranded 1/2x 16 ... 14 AWG Flexible 1/2x 16 ... 14 AWG Main Circuit 10 inlb Auxiliary Circuit 7 inlb B300 R300

Certificates and Declarations (Document Number)