Sunteți pe pagina 1din 52

Meter Mounting Equipment

REC/Municipal

2
MILBANK OVERVIEW

MILBANK OVERVIEW

Charles A. Milbank 1879-1966

Bill Martin

Robert F. Waldrop, 1922-2002

Robert F. Waldrop, II Chairman

Katrina Waldrop Henke Vice Chairman

MilbankQuality Metering Products for 80 Years


ilbank Manufacturing Company was established in 1927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturers representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbanks employee base of over 1,000 workers, along with our five manufacturing facilities com-

prising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you dont find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is

an important factor to remain competitive in todays electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the pastwith dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that...

FAMILY MAKES A DIFFERENCE!

TABLE OF CONTENTS

3
TABLE OF CONTENTS

SINGLE POSITION 125 AMP4 TERMINALRINGLESS/RING TYPE600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 200 AMP4 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 200 AMP4 TERMINALRING TYPE600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 200 AMP4, 5, & 7 TERMINALJAW CLAMPING LEVER BYPASSRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . 8 200 AMP5 TERMINALJAW CLAMPING LEVER BYPASSRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 320 AMP4 & 5 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 320 AMP4 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 320 AMP7 TERMINALSIDE WIREWAYRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 METER MAINS 100 AMP4 TERMINALRING TYPEMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 100 & 200 AMP4 TERMINALRINGLESSMETER MAINLOAD SIDE DISTRIBUTION . . . . . . . . . . . . . . . . . . . . . . . 14 200 AMP4 TERMINALRINGLESSMETER MAIN WITH BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 200 AMP4 TERMINALRINGLESSMETER MAIN22K AIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 200 AMP4 TERMINALRINGLESSMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 320 AMP4 TERMINALRINGLESSMETER MAINSIDE WIREWAYWITH BREAKERS . . . . . . . . . . . . . . . . . . . 18-19 200 AMP4 TERMINALRING TYPEMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 200 AMP4 & 5 TERMINALRINGLESSMETER MAINJAW CLAMPINGAUXILIARY POWER CENTER . . . . . . . . 21 CT RATED 20 AMP13 TERMINALRINGLESS/RING TYPETRANSFORMER RATED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 20 AMP13 TERMINAL RINGLESSTRANSFORMER RATED600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 20 & 80 AMP13 TERMINALRINGLESSJAW CLAMPING LEVER BYPASSTRANSFORMER RATED . . . . . . . . . . 24 400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET PTS, DONUT OR BAR TYPE . . . . . . . . . . . . . . . 26 12001600 AMPMAXITRANSOCKET WITH PTS AND BAR TYPE CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 PEDESTALS/METER MAINS 100/200 AMP4 TERMINALMETER MAIN PEDESTAL1120/240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 320 AMP4 TERMINALMETER PEDESTAL WITH LEVER BYPASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 480 AMP CONTINUOUS4 TERMINALK SERIES METER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 100/200 AMP4 TERMINALRESIDENTIAL PEDESTALSINGLE OR DOUBLE POSITION13W600VAC . . . . . . 31 200 AMPRINGLESSMETERED PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33 U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS/RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 34-35 200 AMP4 TERMINALMOBILE HOME METER PEDESTALSRINGLESS120/240VAC . . . . . . . . . . . . . . . . . . . . . 36 100, 200 & 400 AMPTERMINAL BOX1 & 3120/240 VOLT600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 ENCLOSURES CT3R CURRENT TRANSFORMER CABINET/PANEL ENCLOSURETYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MISCELLANEOUS ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 UQFP PLUGIN SERIES CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 UQFB BOLTON SERIES CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 CONDUIT & AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 METER FORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 WATTHOUR METER FORMSSTD FORMSTRANSFORMER RATED OR SELFCONTAINED . . . . . . . . . . . . . . . . 47 STANDARD NEMA CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ADDITIONAL MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

4
125 AMP4 TERMINALSINGLE POSITIONRINGLESS / RING TYPE600 VAC

125 AMP4 TERMINALSINGLE POSITIONRINGLESS / RING TYPE600 VAC

1 4 3 4
5 6

2
7487
5

1 4 3 4
6

2
7490

U7487-RL-TG

U7490-RL-TG

125 AMPSINGLE POSITION4 TERMINALRINGLESS


AMP 125 SERVICE OH/UG CATALOG NUMBER U7487-RL-TG HUB H.O. CONNECTORS CU/AL #6-2/0 DIMENSIONS D" 3
5

CONCENTRIC K.O.S 1 1
1

W" 8

H" 11
1

2 1
1

3 2

4 114

6
1

16

125 AMPSINGLE POSITION4 TERMINALRING TYPE


AMP 125 SERVICE OH/UG CATALOG NUMBER U7490-RL-TG HUB H.O. CONNECTORS CU/AL #6-2/0 DIMENSIONS D" 3
5

CONCENTRIC K.O.S 1 1
1

W" 8

H" 11
1

2 112

3 2

4 114

6
1

16

FIFTH TERMINAL: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round opening at the 9 oclock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: Ring type units supplied with an MR-2 snap action sealing ring as standard. BYPASS: Horn type bypass is available. Add suffix -KK to U7487.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

200 AMP4 TERMINALRINGLESS600 VAC

5
200 AMP4 TERMINALRINGLESS600 VAC

2
7040 7021

4
5 5

3
6

U7040-RL-TG

2
1980

U1980-O

200 AMP4 TERMINALRINGLESS


SERVICE OH/UG OH UG CATALOG NUMBER U7040-RL-TG U7021-RL-TG U1980-O CONNECTORS HUB LINE H.O. H.O.
BLANK CU/AL

LOAD #6-350 #6-350 #6-350

BY- DIMENSIONS PASS D" W" H"


NONE NONE NONE

CONCENTRIC K.O.S 1 2 2 2
1 1 1

2 2 2 2
1 1 1

3 2 2
1 1

4 2
1

5
1 1 4, 2

6
1

#6-350 #6-350 #6-350

4 4 4

1 1 1

8 8 2

11 8 13

15 15 15

1 1 1

2 2 4

2 2 2

2 2 2

2 2

2 2

1
1

4 2

1 1 4, 2

1 1 4, 2

FIFTH TERMINAL: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 oclock position. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. BYPASS: Horn type bypass is available. Add suffix -KK to catalog number .

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

6
200 AMP4 TERMINALRINGLESS600 VAC

200 AMP4 TERMINALRINGLESS600 VAC

2
4532 7043

4
5 5

3
6

U4532-XL

U7043-XL-TG

200 AMP4 TERMINALOVERHEAD / UNDERGROUNDRINGLESS


CONNECTORS CATALOG NUMBER U4532-XL U7043-XL-TG HUB LINE C.P C.P #6-350 #6-350
CU/AL

LOAD
DUAL #6-350

BY- DIMENSIONS PASS D" W" H"


NONE NONE

CONCENTRIC K.O.S 1 2 2
1 1

2 2 2
1 1

3 3 3

4 3 3

5
1 1

6
1 1 4, 2

4 4

7 7

8 8

15 13

20 15

1 1

2 2

2 2

2 2

4 4

#6-350

1 1 4, 2

FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

200 AMP4 TERMINALRING TYPE600 VAC

7
200 AMP4 TERMINALRING TYPE600 VAC

7017

1
U7017-RL-TG

2
U7018-XL-TG
7018

4
5

3
6

200 AMP4 TERMINALRING TYPE


CONNECTORS SERVICE OH OH/UG CATALOG NUMBER U7017-RL-TG U7018-XL-TG HUB LINE H.O. C.P. #6-350 #6-350
CU/AL

LOAD #6-350 #6-350

BY- DIMENSIONS PASS D " W" H"


NONE NONE

CONCENTRIC K.O.S 1 2 2
1 1

2 2 2
1 1

3 2 2
1 1

4 2
1

5
1

6
1 1 4, 2

4 4

1 1

8 8

8 11

15 15

1 1

2 2

2 2

2 2

2 2

1 1 4, 2

HUBS: For proper hub selection see the hub suffix chart below or accessory section. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum internal hex lay-in type connectors are tin plated. Units are supplied with duplex neutral. TRIPLEX GROUND (-TG): Factory installed. SEALING RINGS: Ring type units are supplied with MR-2, snap action, sealing rings as standard.

INTERCHANGEABLE UNIT HUBS


SIZE
1" 114" 112" 2" 212" MILBANK CAT. NO.

SUFFIX

A7514 A7515 A7516 A7517 A7518

-WL -YL -ZL -DL -EL

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

8
200 AMP4, 5 & 7 TERMINALSINGLE POSITIONRINGLESS JAW CLAMPING LEVER BYPASS600 VAC

200 AMP4, 5 & 7 TERMINALSINGLE POSITIONRINGLESS JAW CLAMPING LEVER BYPASS600 VAC

U9701-RXL

U9800-RRL

U9551-RXL

2
9550 9700
5

2
9800

2
9551 9701 9801

4
5

3
6

200 AMP4 TERMINALRINGLESS13W OR 33W


SERVICE OH OH/UG CATALOG NUMBER U9800-RRL U9801-RXL HUB H.O. C.P. CONNECTORS BYCU/AL PASS #6-350 #6-350
LEVER LEVER

DIMENSIONS D" 4 4
7 7

CONCENTRIC K.O.S 1 3 3 2 2 2
1 1

W" 10 13

H" 18
1

3 3 3

5
1 1 4, 2

6
3

8 8

2 2

19

1 1 4, 2

200 AMP5 TERMINALRINGLESS13W OR 33W


SERVICE OH OH/UG CATALOG NUMBER U9550-RRL U9551-RXL HUB H.O. C.P. CONNECTORS BYCU/AL PASS #6-350 #6-350
LEVER LEVER

DIMENSIONS D" 4 4
7 7

CONCENTRIC K.O.S 1 3 3 2 2 2
1 1

W" 10 13

H" 18
1

3 3 3

5
1 1 4, 2

6
3

8 8

2 2

19

1 1 4, 2

200 AMP7 TERMINALRINGLESS34W


SERVICE OH OH/UG CATALOG NUMBER U9700-RRL U9701-RXL HUB H.O. C.P. CONNECTORS CU/AL #6-350 #6-350 BYPASS
LEVER LEVER

DIMENSIONS D" 4 4
7 7

CONCENTRIC K.O.S 1 3 3 2 2 2
1 1

W" 10 13

H" 18
1

3 3 3

5
1 1 4, 2

6
3

8 8

2 2

19

1 1 4, 2

HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: Lever supplies clamping action and also operates bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. U9550 and U9551 units are supplied with duplex neutral, with removable bonding strap for insulated neutral. U9700 series units are supplied with duplex neutral.

Internal Hex Connectors.


Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

200 AMP5 TERMINAL SINGLE POSITION JAW CLAMPING LEVER BYPASS RINGLESSS600 VAC

9
200 AMP5 TERMINAL SINGLE POSITION JAW CLAMPING LEVER BYPASS RINGLESSS600 VAC

2
9581

4
5

3
6

U9581-RXL-QG

200 AMP5 TERMINALRINGLESS13W OR 33W


SERVICE OH/UG CATALOG NUMBER DIMENSIONS HUB CONNECTORS BYCU/AL PASS D" W" H" #6-350
LEVER 4
7

CONCENTRIC K.O.S 1 3 2 2
1

3 3

4 3

5
1

6
1 1 4, 2

U9581-RXL-QG C.P.

13

19

NEUTRAL DISCONNECT: The U9581 has a manual neutral disconnect bolt. HUBS: For proper hub selection, see hub suffix chart in Accessories. BYPASS: Lever supplies clamping action on meter spades and also operates 200 Amp continuous duty bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral, with removable bonding strap for insulated neutral.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

10
320 AMP4 & 5 TERMINALHEAVY DUTY LEVER BYPASSRINGLESS600 VAC

320 AMP4 & 5 TERMINALHEAVY DUTY LEVER BYPASSRINGLESS600 VAC

2
4702 4505

4
5
U4505-X

3
6

320 AMP4 & 5 TERMINALRINGLESS


CONNECTORS TERM SERVICE 4 5 OH/UG OH/UG CATALOG NUMBER U4702-X U4505-X HUB LINE C.P. C.P.
3/8"-16 STUD 3/8"-16 STUD
CU/AL

LOAD
3/8"-16 STUD 3/8"-16 STUD

BY- DIMENSIONS PASS D" W" H"


LEVER LEVER

CONCENTRIC K.O.S 1 3 3 2 3 3 3 3 3 4 3 3 5
1 1

6
1 1 4, 2

4 4

7 7

8 8

15 15

28 28

1 1

4 4

4 4

1 1 4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page. LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: Stud type units supplied with 3/8"-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra K1539 (350 kcmil-1), K3082 (350 kcmil-3), K1540 (600 kcmil-1) or K3441 (600 kcmil-3). For twin lug connectors order as extra K1350 (350 kcmil-1) or K3442 (350 kcmil-3). Separate kits are required for both line and load.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

10

320 AMP4 TERMINALSINGLE POSITIONRINGLESS600 VAC

11
320 AMP4 TERMINALSINGLE POSITIONRINGLESS600 VAC

400 AMP MAX 320 AMP CONTINUOUS

2
1797

1
3
5

2
1079

3
6

U1797-O-K3L-K2L U1079-R

320 AMP4 TERMINALRINGLESS600 VAC


SVC. OH UG OH CATALOG NUMBER U1079-R U1797-O-K3L-K2L U1779-RRL-K3-K2 FIFTH TERM. K3866 K3865 CONNECTORS HUB H.O.
3

CU/AL

LINE

DIMENSIONS BYLOAD PASS D" W" H"


LEVER LEVER LEVER

CONCENTRIC K.O.S 1 3 3 3 2 2
1

3 3 3 3

4 3 3 3

5
1 1 1

6
1 1 4, 2

8"-16 STUDS
TWIN #6-350 3/8"-16 STUD

4 4 4

7 7 7

8 8 8

13 15 13

38

4 4

2 2

4 4 4

BLANK #4-600 or (2) 1/0-250 #4-600 or H.O. (2) 1/0-250

30 38
3

3 2
1

1 1 4, 2 1 1 4, 2

HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: Lever supplies clamping action and also operates bypass device on the U1079 & U1797. CONNECTOR KITS: Stud type units are supplied with 38"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. Order K1539 (single #350), K1540 (single #600) or K1350 (twin #350). See accessories page. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1079. Order as extra K3865 for U1797-0. LUG SIZE RANGE: See accessories page for lug size range for U1797 units.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

11

12
320 AMP7 TERMINALSINGLE POSITIONRINGLESS600 VAC

320 AMP7 TERMINALSINGLE POSITIONRINGLESS600 VAC

1 3
6

2
2594

U2594-X

320 AMP7 TERMINALSIDE WIREWAYRINGLESS


SERVICE OH/UG CATALOG NUMBER U2594-X HUB C.P. CONNECTORS CU/AL
3

BYPASS
LEVER

DIMENSIONS D" 6
1

CONCENTRIC K.O.S 1 2 3 3 4 4 4 5
1

W" 19

H" 34
1

6
1

8"-16 STUDS

2,34,1

BYPASS: Lever supplies clamping action on meter spades and operates bypass device. CONNECTOR KITS: Stud type units are supplied with 38"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. For single lug connector kits order as extra K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate kits are required for both line and load.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

12

100 AMP4 TERMINALMETER MAINSRINGLESS/RING TYPE

13
100 AMP4 TERMINALMETER MAINSRINGLESS/RING TYPE

3499
4 5 3 6 4

2
8144

U3499-XL

U8144-XL

4 TERMINALMETER MAINRINGLESS13W
AMPS 100 100 SERVICE OH/UG OH/UG CATALOG NUMBER U3499-XL-100 U3499-RL HUB C.P. H.O.
CONNECTOR CU/AL

LINE #6-2/0 #6-2/0

BY- DIMENSIONS LOAD PASS D" W" H"


NONE NONE

CONCENTRIC K.O.S 1 2 2 2 2 2 3 2 2 4 2 2 5 6
1 1 4, 2

#6-1/0 #14-1/0

334 33

11 11

22 22

1 1 4, 2

FIFTH TERMINAL: For field installed fifth terminal on U3499, order catalog number 5T8K2 (9 oclock position only). HUBS: For proper hub selection refer to the hub suffix chart on the Accessory page. FACTORY INSTALLED CIRCUIT BREAKERS: The U3499-XL-100 has a factory installed 2 pole 100 amp breaker.

4 TERMINALMETER MAINRING TYPE13W


AMPS 100 SERVICE OH/UG CATALOG NUMBER U8144-XL HUB
CONNECTOR CU/AL

LINE H.O. #6-2/0

DIMENSIONS BYPASS LOAD D" W" H" C/B


NONE

CONCENTRIC K.O.S 1 2 2 2 3 2 4 2 5
1 1 4, 2

334

11

22

HUBS: For proper hub selection refer to the hub suffix chart on the accessory page. SEALING RINGS: Ring type units priced with MR-2 sealing ring. See accessory page for other choices. BREAKERS: The U8144 does not come with breakers unless specified on order and requires plug-in style.

BREAKER COMPATIBILITY CHART


AMPS 0-100 CUTLERHAMMER QUICKLAG P BR SIEMENS QP GENERAL ELECTRIC Q LINE SQUARE D HOMELINE

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

13

14
100 & 200 AMP4 TERMINALMETER MAINRINGLESS WITH LOAD SIDE DISTRIBUTION120 / 240 VAC

100 & 200 AMP4 TERMINALMETER MAINRINGLESS WITH LOAD SIDE DISTRIBUTION120 / 240 VAC
SUPPLIED WITH BREAKERS

3
6

9647

3
U9648-RL-100

3
5

9648

U9647N-RL-200

4 TERMINALMETER MAINWITH TRIPLE TAP LUGSRINGLESS13W


CONNECTORS AMP SERVICE 100 200 OH OH/UG CATALOG NUMBER U9648-RL-100 HUB LINE H.O. #6-2/0 #6-350
CU/AL

LOAD

BY- DIMENSIONS PASS D" W" H"


1 7

CONCENTRIC K.O.S 1 2
1

2 2
1

3 2 3

4
1 1 4, 2

5
1 1

6
1 1 4, 2

(3) #12-1/0 NONE 4 (3) #6-350 NONE 4

8 8

8 13

26 33

4 4

U9647N-RL-200 H.O.

HUBS: For proper hub selection, refer to the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated with triplex on the load side. BREAKERS: Supplied with factory installed double pole circuit breakers of amperage shown. FIFTH TERMINAL: For field installed fifth terminal, order catalog number 5T8K2 for U9648. For U9647, order catalog number K5T.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

14

200 AMP4 TERMINALRINGLESSMETER MAIN WITH LOAD CENTER

15
200 AMP4 TERMINALRINGLESSMETER MAIN WITH LOAD CENTER

1
5
7

1
5 6 5 6

2
5024

UAP5024-XL

4 TERMINALRINGLESSMETER SOCKET / CB COMBO


AMPS 200
SERVICE

CATALOG NUMBER UAP5024-XL

HUB C.P.

CONNECTORS CU/AL

LINE #6-350

BYPASS
NONE

DIMENSIONS D" 4
1

CONCENTRIC K.O.S 1 2 2 2 3 3 4 2
1

W" 14
1

H" 24

5
1 3 1 2, 4,

6
1 3 2, 4

7
1 1 4, 2

OH/UG

BUSSING: Load side bus bars and circuit breaker interior are made from plated copper WIREWAY: Provided with underground pull section wireway with removable cover BREAKERS: Breaker section has provision for six double pole plug-in type circuit breakers. All circuit breakers will be parallel.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

15

16
200 AMPRING TYPE / RINGLESS METER MAINS4 TERMINAL22K AIC

200 AMPRING TYPE / RINGLESS METER MAINS4 TERMINAL22K AIC

1
5

2
6

5168 5169 5268 5269

U5168-XTL-200

U5268-XTL-200-KK

200 AMP4 TERMINALMETER MAIN22K AIC120/240 VOLT13WRINGLESS OVERHEAD / UNDERGROUND8 & 20 CIRCUIT INTERIOR
CIRCUITS 8 20 CATALOG NUMBER U5168-XTL-200 U5268-XTL-200 CONNECTORS HUB LINE C.P. C.P. #6-350 #6-350 DIMENSIONS BYPASS D" W" H"
NONE NONE

CONCENTRIC K.O.S 1 2 2 2 2 2 3 3 3 4 2 2
1 1

4 4

1 1

2 14 8 32 2 14 8 32
1

2 2

1 3 2, 4, 1 1 2 3 4

, ,

1 3 2, 4, 1 1 2 3 4

200 AMP4 TERMINALMETER MAIN22K AIC120/240 VOLT13WRING TYPE OVERHEAD / UNDERGROUND8 & 20 CIRCUIT INTERIOR
CIRCUITS 8 20 CATALOG NUMBER U5169-XTL-200 U5269-XTL-200 CONNECTORS HUB LINE C.P. C.P. #6-350 #6-350 DIMENSIONS BYPASS D" W" H"
NONE NONE

CONCENTRIC K.O.S 1 2 2 2 2 2 3 3 3 4 2 2
1 1

2 14 8 32 412 1418 32
4

2 2

1 3 2, 4, 1 1 2 3 4

, ,

1 3 2, 4, 1 1 2 3 4

HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. INTERIOR: U5168 units have 8-circuit interior; U5268 units have 20-circuit interior. FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oclock position only. BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN; order K5830 for small frame Q to small frame Q (100A version). SUB-FEED LUGS: #6-350 kcmil subfeed lugs provided on 8 and 10 circuit interior. Not available on 20 circuit interior. *Amperage rating limited to main breaker rating. Interior has 10 branch circuit breaker provisions on unit with 100 amp main.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

16

200 AMP4 TERMINALRINGLESS

17
200 AMP4 TERMINALRINGLESS

Reserve Generator Hook-up Option K5060 Kit


Available K5060 dead front/transfer bar kit field converts the U5712 to accommodate hook-up of a back-fed reserve generator.

U5712-XL-200

200 AMP4 TERMINALRINGLESS


CONNECTORS SERVICE OH/UG CATALOG NUMBER U5712-XL-200 HUB LINE H.O. #6-350
CU/AL

LOAD #6-350

BY- DIMENSIONS PASS D" W" H" NONE 4


15

CONCENTRIC K.O.S 1 2 1-2


1

18 1534 40 114 -212

4 -12

BREAKERS: Units are factory supplied with Milbank 200 amp plug-in type UQFP breaker. Other amperages available. When applicable, replace suffix with desired amperage (-100, -125, -150). BRANCE BREAKERS: (12) single-pole branch circuits available. FIFTH TERMINALS: Factory installed in 9 oclock position on U5712-XL-200-5T9. For field installed on U5712-XL-200 in 6 or 9 oclock position order kit K3865.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

17

18
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS

320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS

400 AMP. MAX. 320 AMP. CONTINUOUS

2
4031

U4031-O-2/200

320 AMP4 TERMINAL1RINGLESSLEVER BYPASSMETER MAIN WITH BREAKERS


CATALOG NUMBER U4031-O-2/200 SERVICE HUB UG BLANK CONNECTORS CU/AL LINE LOAD
3/8"-16 STUDS #1/0-300

BYPASS

DIMENSIONS D" W" 25 H" 30

CONCENTRIC K.O.S 1 3 2 3 3 4 4 3 5
1 1 4, 2

3 LEVER 5 4

CONNECTORS: The line wire section is supplied with 3/8"-16 studs with hex head nuts and captive Belleville washers. For single lug connector kits order as extra: K1539 (350 kcmil), K1540 (600 kcmil.) For twin: K1350 (350 kcmil.) BREAKERS: The U4031-O-2/200 is supplied with (2) bolt-on Milbank UQFB-200 breakers. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

18

320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS

19
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS

5059

U5059-X-2/200 (shown without lugs)

320 AMP METER MAIN WITH BREAKERSSIDE WIREWAY13WRINGLESS120/240 VAC


CONNECTORS SERVICE OH/UG CATALOG NUMBER U5059-X-2/200-K3L HUB LINE C.P.
#4-600
CU/AL

LOAD
1/0-300

FIFTH BYDIMENSIONS TERM. PASS D" W" H" KIT K3866


LEVER

CONCENTRIC K.O.S 1 3 2 3 3 3 4
1

5
1 1 4, 2

15

42

NEUTRAL: Bonded neutral and ground factory Installed. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC Standard. BYPASS: Lever supplies clamping action and operates bypass device. FIFTH TERMINAL: For field installed fifth terminal order separately catalog number K3865.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

19

20
200 AMP7 TERMINALMETER MAINRINGLESS

200 AMP7 TERMINALMETER MAINRINGLESS

5750

U5750-RXL-200-BL

7 TERMINALMETER MAINRINGLESS34W
AMPS 200 CATALOG NUMBER HUB
CONNECTOR CU/AL

LINE

DIMENSIONS BYLOAD PASS D" W" H" C/B


LEVER

CONCENTRIC K.O.S 1 11 2 3-4


1

U5750-RXL-200-BL C.P. #6-350

53

17 3

8 34

4-3

2-2

HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. BREAKER: Factory installed 200 amp, 3-pole, 10,000 AIC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

20

200 AMP4 & 5 TERMINAL300 VACMETER MAIN RINGLESSJAW CLAMPING LEVERAUXILIARY POWER CENTER

21
200 AMP4 & 5 TERMINAL300 VACMETER MAIN RINGLESSJAW CLAMPING LEVERAUXILIARY POWER CENTER

2
4834

3
6

U4834-XL-200-5T9
(Shown with optional 200 Amp Auxiliary breaker)

200 AMP4 & 5 TERMINAL (AT 9 OCLOCK)METER MAIN MANUAL TRANSFER SWITCHRINGLESS13W120/240 VAC
AMPS SERVICE 200 OH/UG CATALOG NUMBER U4834-XL-200-5T9 HUB
CONNECTOR CU/AL

LINE

BYPASS LOAD

DIMENSIONS D"
1

CONCENTRIC K.O.S 1 3 2 3 3 3 4 3 5
1 1 4, 2

W" 17

H" 39

C.P. #6-350 (3) #6-350 LEVER 5

AUXILIARY BREAKERS: Must be ordered separately. Use UQFP-(AMP) style breaker. FIFTH TERMINALS: For field installed fifth terminals, order catalog number K4935. Units with -5T9 suffix have fifth terminals factory installed in 9 oclock position.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

21

22
20 AMP13 TERMINALCURRENT TRANSFORMER RATEDRINGLESS / RING TYPE

20 AMP13 TERMINALCURRENT TRANSFORMER RATEDRINGLESS / RING TYPE

3
5

UC7237 UC7545

UC7545-RL

UC7237-RL

20 AMP13 TERMINALRINGLESSPLUNGER TYPE BYPASSOVERHEAD / UNDERGROUND


NO. METER OF FORM TERMS 13
6,8,9S & (ALT) 10S

CATALOG NUMBER UC7237-RL

HUB C.P.

CONNECTORS CU #14 - #10

BYPASS
PLUNGER

DIMENSIONS D" 3 16
5

CONCENTRIC K.O.S 1 11 2 11 3 11 4 2 5 11 6
1

W" 8

H" 14

20 AMP13 TERMINALRING TYPEPLUNGER TYPE BYPASSOVERHEAD / UNDERGROUND


NO. METER OF FORM TERMS 13
6,8,9S & (ALT) 10S

CATALOG NUMBER UC7545-RL

HUB H.O.

CONNECTORS CU #14 - #4 MAX

BYPASS
PLUNGER

DIMENSIONS D" 3
5

CONCENTRIC K.O.S 1 112 2 114 3 114 4 2 5 114 6


1

W" 8

H" 14

16

HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Plunger type bypass automatically closes when meter is removed. CONNECTORS: Units are supplied with sleeve type connectors (#14-#2) NOTE: 5, 6, and 8 terminal sockets are also available.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

22

20 AMP13 TERMINALTRANSFORMER RATEDRINGLESS600 VAC

23
20 AMP13 TERMINALTRANSFORMER RATEDRINGLESS600 VAC

UC7449

5
6

UC7449-XL

2 PIECE COVERRINGLESSWITH TEST SWITCH PROVISION


NO. OF TERMS 13 CATALOG NUMBER UC7449-RL
BYHUB CONNECTORS PASS CU

DIMENSIONS D W 12 H 20 1 114

CONCENTRIC K.O.S 2 114 3 114 4 114 5 114 5


1 1 4, 2

H.O.

#14 - #2 MAX

NONE 418

HUBS: For proper hub selection, see the hub suffix chart on the accessory page. SEALING RINGS: Ring type units are supplied with one MR2 snap-type sealing ring. PREWIRING: If standard factory prewiring is required, or custom factory prewiring is required, include meter socket catalog number, test switch model and number, meter form number and provide copy of your wiring diagram. SERVICE: Units are rated for overhead or underground service. NOTE: 5, 6, and 8 terminal sockets are also available.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

23

24
20 & 80 AMPTRANSFORMER RATED JAW CLAMPING LEVER BYPASSRINGLESS600 VAC

20 & 80 AMPTRANSFORMER RATED JAW CLAMPING LEVER BYPASSRINGLESS600 VAC

1 5 5

2
4993

U4493-XL

80 AMP TRANSFORMER RATEDLEVER BYPASSRINGLESS


NO. OF SERVICE TERMS 13 OH/UG CATALOG NUMBER U4493-XL HUB C.P. CONNECTORS CU #14 - #4 MAX BYPASS DIMENSIONS D
7

CONCENTRIC K.O.S 1 3 2 1
1

W 10

H 18
1

3
3

4
3

5 1
1

6
1

LEVER 4

BYPASS: Lever operates current bypass device and also supplies clamping action on current meter spades. TEST SWITCH COVERS: Units on this page can be used with clear lexan cover. See accessory page for ordering information. CONNECTORS: Units are supplied with mechanical type connectors (#4 max.) If compression type connectors (#10) are preferred, change catalog prefix to S (i.e. U4493-XL becomes S4493-XL.) The S also designates non-U/L. REMOVABLE HANDLE: When removable handle is desired add suffix -RH to catalog number (i.e. U4493-XL becomes U4493-XL-RH.) REPLACEMENT REMOVABLE HANDLE: When a replacement removable handle (RH) is required order part #Z706850-SC. Replacement handle will only work with factory ordered RH units. BLOCK ASSEMBLY: Block assembly rated at 80 amps-test switch rated at 20 ampstherefore, unit defaults to test switch rating of 20 amps. NOTE: 6 and 8 terminal sockets are also available.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

24

400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE C.T.S

25
400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE C.T.S

U2161-XT-TS10-9586 (Pre-wired as example only)

U2161-XT

UNITS PRICED WITHOUT TRANSFORMERS OR TEST SWITCH. CONTACT GENERAL OFFICE FOR ORDERING INFORMATION. FOR USE WITH BAR TYPE C.T.S 200 / 5 300 / 5 400 / 5

2
2161

3
5

4 3
5

400 AMP6, 8 & 13 TERMINALRINGLESS


NO. METER OF FORM TERMS 4S 5S 6, 8, 9S 6 8 13 CATALOG NUMBER U2228-XT U2229-XT U2161-XT HUB (2) C.P. (2) C.P. (2) C.P. CONNECTORS 500 500 500 TRF. MTGS.
1/2"-13 TWIN STUDS 1/2"-13 TWIN STUDS 1/2"-13 TWIN STUDS

DIMENSIONS D" 12 12 12 W" 24 24 33 716 H" 36 36 36 1 4 4 4

CONCENTRIC K.O.S 2 4 4 4 3 4 4 4 4 4 4 4 5 1 1 1

HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. STUDS: 1/2"-13 twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied. PREWIRING: If standard factory prewiring is required, refer to wiring diagrams in the general engineering section. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, be sure to specify test switch catalog number, meter form number and provide a copy of your wiring diagram. If C.T.s are to be factory installed, specify C.T. ratio. There is no provision for P.Ts in this unit. Contact factory for pricing.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

25

26
600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET P.T.S, DONUT OR BAR TYPE C.T.S600 VAC

600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET P.T.S, DONUT OR BAR TYPE C.T.S600 VAC

S1890-XT S2690-XT S2690-XT

2 2
1891 3912 1890

1 3

1 3

1 3

2
3831 2690 2674

600 AMP / 600 VOLTWITH P.T.S AND DONUT TYPE C.T.SRINGLESS


NO. METER OF FORM TERMS 5S 6S 6S 8 13 14 CATALOG NUMBER S1891-XT S3912-XT S1890-XT HUB (2) C.P. (2) C.P. (2) C.P. P.T.S QTY. & RATIO (2) 4:1 (2) 2.5:1 (2) 2.5:1 C.T.S QTY. & RATIO (2) 200/5 (3) 200/5 (3) 200/5 DIMENSIONS D" 9 2
1

CONCENTRIC K.O.S 1 2 2
1

W" 18 18 18

H" 24 24 24

2 2 2
1

3 2 2
1

4 1 1 1

5
11

16 16 16

912 9 2
1

212 2 2
1

212 2 2
1

212 2 2
1

11

11

600 AMP / 600 VOLTBAR TYPE C.T.S ONLYRINGLESS


NO. METER OF FORM TERMS 4S 5S 8S 6 8 13 CATALOG NUMBER S3831-XT S2690-XT S2674-XT HUB (2) C.P. (2) C.P. (2) C.P. C.T. QTY. 2 2 3 C.T. & RATIO 200/5 200/5 200/5 DIMENSIONS D" 1114 1114 1114 W" 18 18 18 H" 30 30 30 CONCENTRIC K.O.S 1 312 312 312 2 312 312 312 3 4 4 4 4 1 1 1

HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. PREWIRING: Units supplied prewired with test switch and transformers in place. Contact factory if wiring diagram is desired. PRICING: Contact general office for pricing information.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

26

1200-1600 AMPMAXI-TRANSOCKET WITH P.T.S AND BAR TYPE C.T.S480 VAC

27
1200-1600 AMPMAXI-TRANSOCKET WITH P.T.S AND BAR TYPE C.T.S480 VAC

S2777-4X

S2777-4X

2777

1200-1600 AMPWITH P.T.S AND BAR TYPE C.T.SRINGLESS34W


NO. METER OF FORM TERMS 6S 8S 14 14 CATALOG NUMBER S2777-4X S2811-4X HUB (4) C.P. (4) C.P. P.T.S QTY. & RATIO (2) 2.5:1 NONE C.T.S QTY. & RATIO (3) 400/5 (3) 400/5 DIMENSIONS D" 14 14 W" 30 30 H" 42 42 CONCENTRIC K.O.S 1
1

2
1

3
1

4
1

2 2

2 2

2 2

HUBS: Units are supplied with 4 closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. PREWIRING: Units supplied with test switch and transformers in place. Contact factory if wiring diagram is desired. PRICING: Contact general office for pricing information.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

27

28
100 / 200 AMP1120 / 240 VAC4 TERMINALMETER MAIN PEDESTAL

100 / 200 AMP1120 / 240 VAC4 TERMINALMETER MAIN PEDESTAL

MILBANK

STD = 79" -LP = 70"

1 2

Grade Line

STD = 36" -LP = 24"

NU8980-O-KK

100 / 200 AMP13WRINGLESSUNDERGROUND FEED


CATALOG NUMBER
HUB
BLANK BLANK BLANK BLANK BLANK BLANK

CONNECTOR CU/AL

LINE
#6-350 #6-350 #6-350 #6-350 #6-350 #6-350

LOAD CB * CB *
#6-1/0 #6-1/0

BYPASS
HORN HORN HORN HORN

MAIN BREAKER 10K 22K

DIMENSIONS
D" 6 6 6 6 6 6 W" 9 9 9 9 9 9 H" 79 70 79 70 79 70

CONCENTRIC K.O.S

1 212 212 21

2 212 212 21

NU8980-O-KK NU8980-O-KK-LP NU8980-O-SF100-KK


NU8980-O-SF100-KK-LP

UQFP Q2100 UQFP UQFP

UQFPH Q2100H UQFPH UQFPH

212 21

212 21

NU8980-O-200-KK NU8980-O-200-KK-LP

1/0-300 HORN 1/0-300 HORN

212

212

* FIELD INSTALLED CIRCUIT BREAKER REQUIRED. MAIN CIRCUIT BREAKERS: For 10K AIC order with factory installed main. For 22K AIC order pedestal without main and order circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit # K4714 and UQFP-M type circuit breaker. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers small frame plug-in type circuit breakers (Milbank, GE, Siemens, Cutler-Hammer, Murray). SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4 circuit interior. Only two single pole spaces available. FIFTH TERMINAL: For field installed 5th terminal order kit # 5T8K2. Mounts in 9 oclock position only. BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service. EXTENSION KIT: Available for low profile (-LP) units only. Order kit # K4694.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

28

320 AMP4 TERMINALMETER PEDESTAL WITH LEVER BYPASS

29
320 AMP4 TERMINALMETER PEDESTAL WITH LEVER BYPASS

320 AMP CONTINUOUS 400 AMP MAX


4 4

1
M I L B A N K

1 2 3

2
Grade Line Grade Line

Grade Line

Grade Line
4
18"

4 18"

13" O.D.

4-27/32" I.D.

16-15/16" 15"

U3849-O-2/200

S1848 Pedestal Extension Unit

U1748-O

320 AMP4 TERMINALMETER MAIN WITH BREAKERSRINGLESS240 VAC


CATALOG NUMBER U3849-O-2/200 SERVICE UG HUB NONE CONNECTORS CU/AL LINE LOAD
3/8" X 16 STUDS

BYPASS

DIMENSIONS D" 4
7

CONCENTRIC K.O.S 1 2
1

W" 13

H" 58

2 2
1

3
5

C.B. #1- 300 LEVER kcmil

16

BREAKERS: The U3849 is furnished with (2) 200 amp Milbank type UQFBH-200 circuit breakers. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848. THIS UNIT IS RATED 22,000 AICSHORT CIRCUIT CURRENT RATING WITH MILBANK UQFBH SERIES CIRCUIT BREAKER.

320 AMP4 TERMINALWITHOUT BREAKERRINGLESS600 VAC


CATALOG NUMBER U1748-O SERVICE UG HUB NONE CONNECTORS CU/AL LINE LOAD
3/8" X 16 STUDS

BYPASS

DIMENSIONS D" 478 W" 13 H" 64 1 212

CONCENTRIC K.O.S 2 212 3 212 4


5

TWIN #6-350 kcmil LEVER

16

CONNECTORS: The line wire section is supplied with 38"16 studs with hex head nuts and captive Belleville washers. The line side connectors are to be supplied by the Utility, load side is furnished. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order kit #K3865. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

29

30
480 AMP CONTINUOUS4 TERMINALK-SERIES METER MAIN

480 AMP CONTINUOUS4 TERMINALK-SERIES METER MAIN

Rated for Overhead or Underground Service (Top Closing Plate Provided) 4 Terminal, 480 Amp Continuous, 13W Suitable for Service Entrance Two Main Circuit Breakers 225 Amp or 200 Amp (Twin Mains Allow Unit to Feed Multiple Panels)

G G G

CATALOG NUMBER
U5067-X-2/200 U5067-X-2/225

BREAKERS
Twin 200-Amp Breakers Twin 225-Amp Breakers

SPECIFICATIONS
G G G G G G G G G

Service Type: OH/UG (top closing plate included) Application: 1, 3W Self-Contained Type MS-K Watt-Hour Meters By-pass Device: Rated 50% Manual Type (Order Separately No. K4687) Cover Style: Sealable Ringless Meter Cover (both in-service and out-or-service positions) Line-Sided Connectors: Twin 350 kcmil Connectors Included Load-Side Connectors: Double 300 kcmil Connectors Included on Breakers Dimensions: 45"H X 24"W X 6"D Weight: 96 lbs. UL Listed

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

30

100 / 200 AMP4 TERMINALRESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION13W600 VAC

31
100 / 200 AMP4 TERMINALRESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION13W600 VAC

3 5
2 1 2

1
3

CHECHA

CHECHA MILBANK

2 2
GRADE LINE

2
4 2 4 5 6 6
18"
Grade Line

Grade Line

18.00

U8303-O Extension Unit S8988

U8436-O

Extension Unit K5800

100 / 200 AMP4 TERMINALRINGLESS13W600 VAC


CONNECTORS AMP SERVICE 200 UG CATALOG NUMBER U8436-O U8303-O HUB
CU/AL (COMPRESSION)

LINE

LOAD #6-350 #6-350

BY- DIMENSIONS PASS D" W" H"


HORN HORN

CONCENTRIC K.O.S 1 2 114 2 2


5

3
5

4
1

5 2 212

6
1 1 4, 2

200 2 POS-UG

4/0 (Line) BLANK 2/0 (Neutral) 4/0 (Line) BLANK 2/0 (Neutral)

4 4

1 1

62 74

16

2 8316

16

212

212

HANGING HOOK: Supplied with keyhole hanger for easy mounting. EXTENSION UNIT: For 24" burial applications, order extension unit S8988 for U8303-O. For 15" burial applications, order extension unit K5800 for U8436; for 30" applications, order (2) K5800 units. FIFTH TERMINAL: For field installed fifth terminal on U8436, order catalog number K5T (9 oclock position). For field installed fifth terminal on U8303-O, order catalog number 5T8K2 (9 oclock position). BYPASS: Horn type bypass used on both units.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

31

32
200 AMPRINGLESSMETERED PEDESTALS

200 AMPRINGLESSMETERED PEDESTALS

U5136-0-200S with series wired main & K5400-520GR kit

SPECIFICATIONS
UL listed conforms to EUSERC drawing number 307 200 amp maximum, 120/240 volt, single phase, three wire meter socket Ringless meter socket with horn bypass and stainless steel latch Short circuit withstand rating 22K AIC. Type 3R construction for durable outdoor use, one piece post lockable and sealable Milbank grey polyester powder coat finish Wire terminations accept copper or aluminum conductors Line & Neutral: (2) #6-350 kcmil per phase Line Ground: (4) #14-1/0 Load (CB): 2/0 to 300 kcmil per pole Load Neutral: (1) #6-350 kcmil Load Ground: (2) #14-1/0, (4) #14/6 Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M. Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See Accessories.

32

200 AMPRINGLESSMETERED PEDESTALS

33
200 AMPRINGLESSMETERED PEDESTALS

SINGLE PEDESTAL (Direct Burial)


CATALOG NUMBER
N N N

MAIN BREAKER
N N

MAIN CB
100 200

BRANCH
4 Circuit 4 Circuit 4 Circuit

WEIGHT (lbs)
82 82 80

U5136-O-100S U5136-O-200S U5136-O (parallel wired)

UQFPH-M-100 UQFPH-M-200 provision for UQFPH-M Series

SINGLE PEDESTAL (Pad Mount)


U5138-O-200S U5138-O (parallel wired)
UQFPH-M-200 provision for UQFPH-M Series 200 4 Circuit 4 Circuit 82 80

DOUBLE PEDESTAL (Direct Burial)


CATALOG NUMBER
N N N

MAIN BREAKER
(2) UQFPH-M-100 (2) UQFPH-M-200

MAIN CB
100 200

BRANCH
4 Circuit 4 Circuit 4 Circuit

WEIGHT (lbs)
115 115 111

U5137-O-100S U5137-O-200S U5137-O (parallel wired)

provision for (2) UQFPH-M Series

DOUBLE PEDESTAL (Pad Mount)


U5139-O (parallel wired)
provision for (2) UQFPH-M Series 4 Circuit 111

RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY)


CATALOG #
N

RECEPTACLE
5-20R Duplex GFI TT30R 14-50R

CIRCUIT BREAKER CONDUCTOR CONFIGURATION


20 Amp, 1 Pole 30 Amp, 1 Pole 50 Amp, 2 Pole 12 Awg 10 Awg 8 Awg GFI Rec.

K5400-520GR K5400-TT30 K5400-1450 K5400-BRIDGE-1POS K5400-BRIDGE-2POS K5415 K5035 K5T K5193 K5194 K3450

N N N N N N N N N

Self-grounded one position receptacle bridge with hardware Self-grounded two position receptacle bridge with hardware Stabilizer Foot with hardware Pad Mount Kit with hardware for U5138/39 pad mount pedestals required 5th Terminal for 208y / 120 volt 3-wire service Bus kit to convert series-wired main breaker to parallel Wire kit to convert parallel-wired main breaker to series Telephone / CATV mounting bracket (mounts left or right)

Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. K5415 Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals require K5035 pad mount kit. Order separately.
N Stock item availability subject to prior sale.

Non-stock items minimum order quantity required.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

33

34
U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE

U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE

Concentric Knockouts A (4) = 1, 1-1/2, 2, 2-1/2 B (1) = 1-1/4, 1-1/2, 2 , 1 C (1) = 3/4 1 , 1/2 D (1) = /4 E (1) = 1 Solid

Bridge Kit (4) .173 Extr. Holes E

A
30-3/16

A A
19 13-1/4 8-1/2 D

U5706-O-200S
* (Shown with (2) K5400-520GR receptacles, K5400-BRIDGE-2POS & line side conductor installed.)
OPEN

3-1/2

SPECIFICATIONS
200 amp, 1, 120/240 volt, 22K AIC, underground service only. U5706 has Ringless meter socket available with or without horn bypass (-KK). U5707 has Ring type meter socket with MR-4 screw type meter ring. Suitable for use as service equipment, mobile home service equipment and temporary power service equipment. * Provisions for up to two Type 3R in-use receptacle kits. * Order receptacle and bridge kits separately. See ordering information. Direct burial pedestal suitable for free standing or structure mounted installation. Separate line and load wireways are removable, lockable and sealable for security. Left side is for utility connection. Right side is for customer underground load exit. Convenient knockouts in post for thru-wall load exit requirements. Type 3R enclosure constructed with type G90 galvanized steel. Repaintable light gray polyester powder coat finish. Wire terminations accept copper or aluminum conductors: Line & Neutral: #6-350 Ground: (4) #14-1/0. Main circuit breaker can be series or parallel connected. Universal 4 circuit branch 125 amp interior (up to (2) 2-pole) accepts most manufacturers plug-in type circuit breakers. See wiring diagram.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

34

U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE

35
U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE

U5706 Ringless Pedestal


Catalog Number
N U5706-O-200S N U5706-O-200S-KK

Amps
200 200

Service
120/240 120/240

By-Pass
None Horn

Main Circuit Breaker


200a 2p 200a 2p

Main Wired
Series Series

Replacement Main Type*


UQFPH-M UQFPH-M

Branch Circuits
4 4

Weight LBS.
79 79

Up to two receptacle/circuit breaker kits can be field or factory installed. See below for ordering information. Contact factory for factory installed kits.

To increase pedestal height, order field-installed post extension kit K5708. For field installed fifth terminal in the 9 oclock position, order kit 5T9. For field converting from parallel to series wired, order kit K5194. For field converting from series to parallel wired, order kit K5193.

Receptacle / Circuit Breaker Kits & Receptacle Bridge Kits


Catalog Number
N K5400-520GR N K5400-620 N K5400-620GB N K5400-1450 N K5400-1450GB

Amps/ Volts
20a 120v 20a 240v 20a 240v 50a 120/240v 50a 120/240v

NEMA Config
5-20R Duplex GFI 6-20R Simplex 6-20R Simplex 14-50R 14-50R

Circuit Breaker
20a 1p 20a 2p 20a 240v GFI 50a 120/240v 50a 120/240v GFI

Conductor
12 awg 12 awg 12 awg 8 awg 8 awg

Configuration
Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 4 Fig. 5 Fig. 6

N K5400-BRIDGE-1POS Self-grounded ONE position bridge with hardware and instructions. N K5400-BRIDGE-2POS Self-grounded TWO position bridge with hardware and instructions.

Receptacle kits include: receptacle, circuit breaker, connected wire, cover plate, mounting screws and instructions. Contact factory for other kits. NOTE: Receptacle grounding is provided by metal contact with bridge and pedestal. Be sure to torque all fasteners per torque requirements. N Stock item availability subject to prior sale. Non-stock items minimum order quantity required.

Fig. 1 K5400-520GR

Fig. 2 K5400-620

Fig. 3 K5400-620GB

Fig. 4 K5400-1450

Fig. 5 K5400-BRIDGE-1POS

Fig. 6 K5400-BRIDGE-2POS

Fig. 7 UQFPH-M-200

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

35

36
200 AMP4 TERMINALMOBILE HOME METER PEDESTALSRINGLESS120/240 VAC

200 AMP4 TERMINALMOBILE HOME METER PEDESTALSRINGLESS120/240 VAC

41

/8"

55"
51 /2"

10" 21"

STABILIZER FOOT

12"

U4322

U4322-O

PLUG-IN BREAKER COMPATIBILITY CHART


AMPS MILBANK 125-200 100 Q / QN Q
CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS

G.E. Q LINE

SQ-D

HQP / BR / WBJ
QUICKLAG P / BR / HQP

QN QP

MD MP

Q LINE HOMELINE

200 AMP4 TERMINALRINGLESS CATALOG NUMBER


U4322-O-5T9

TWIN CIRCUIT METER BY- MOUNTING LINE CONNECTORS PROV. POSITIONS PASS TYPE CU/AL
SINGLE
LEVER

DESCRIPTION
Provisions for Main with Branch or Parallel Breakers

POST

#6 AWG-350 kcmil

LEVER BYPASS: Lever provides clamping action on meter spades and also operates bypass device. APPLICATION: The U4322 pedestals are suitable for use as service equipment or mobile home service equipment. K5081 / K3188 for direct burial application is included with unit. K5151 for pad mount application must be ordered as extra. BREAKERS: These units are wired as parallel mains and have provisions for six circuits: six single-pole or three double-pole breakers. Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for two 2-pole breakers or four 1-pole breakers in series. FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865 (neutral wire not provided) or K3866 (with neutral wire). Both may be installed in 6 oclock or 9 oclock position.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

36

100, 200 & 400 AMPTERMINAL BOX1 & 3120 / 240 VOLT600 VAC

37
100, 200 & 400 AMPTERMINAL BOX1 & 3120 / 240 VOLT600 VAC

U4540-XL

U4540 U4542

U4548 U4549

100, 200, & 400 AMPTERMINAL BOXES1 & 3120/240 VOLT


PHASE AMPS 1 3 1 3 1 3 100 100 200 200 400 400 VOLTS 120/240 600 120/240 600 120/240 600 CATALOG NUMBER U4544-XL U4546-XL U4540-XL U4542-XL U4548-RXL U4549-RXL HUB C.P. C.P. C.P. C.P. C.P. C.P. CONNECTORS 1 TO CU7AL 3 KIT (6) #12-1/0 (6) #12-1/0 (6) #6-350 (6) #6-350
(3) #6-350 or (2) #4-600 (3) #6-350 or (2) #4-600

DIMENSIONS D" W" H" 18 18 1

CONCENTRIC K.O.S 2 2 2 1
1

3 2 2 2
1

4 1 1 2
1

5
1 1 4, 2

K4543 N/A K4539 N/A K4547 N/A

418 91316 418 91316 4


1

3 3


1 1

1 1 4, 2 1 1 4, 2 1 1 4, 2

14

13

16 23

418 141316 23 5 5 15
1

114 3 3

212 3 3

212
1 1 4, 2

2 27
27

4 4

1512

1 1 4, 2

HUB: Standard hub opening on top with closing plate attached. FEATURES: UL Listed pad lockable Type 3R enclosure. 3 120/240V APPLICATION: Field installable 3 lug kit converts 1 unit to 3 unit.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

37

38
CT3RCURRENT TRANSFORMER CABINET / PANEL ENCLOSURETYPE 3R

CT3RCURRENT TRANSFORMER CABINET / PANEL ENCLOSURETYPE 3R

Application Designed for use as a current transformer cabinet or panel enclosure For outdoor use to provide protection against rain, sleet, and snow, or indoor use to protect against dripping water Construction Enclosure and cover manufactured from 16 or 14 gauge G90U galvanized steel The doors are overlapping with no center post Continuous door hinge with stainless steel hinge pins Three point pad-lockable handle Panel mounting studs provided for optional back panels Drip shield top and seam free sides, front and back Finish ANSI 61 gray polyester powder coating over phosphatized G90U galvanized steel

Industry Standards NEMA Type 3R UL 50Type 3R CULType 3R (Equivalent to CSA)

CATALOG NO. 363010-CT3R 363016-CT3R 363610-CT3R 363612-CT3R 363616-CT3R 483616-CT3R 484812-CT3R 606013-CT3R

PRODUCT FAMILY CN3R CN3R CN3R CN3R CN3R CN3R CN3R CN3R

UPC # (7-84572) 18823 16181 17368 16185 18819 25707 16184 18252

WEIGHT (LBS) 99 121.5 113 118 139 163 210 274

CTN QTY 1 1 1 1 1 1 1 1

WXHXD 36 x 30 x 10 36 x 30 x 16 36 x 36 x 10 36 x 36 x 12 36 x 36 x 16 48 x 36 x 16 48 x 48 x 12 60 x 60 x 13

PANEL CAT. NO. A-36P30 A-36P30 A-36P36 A-36P36 A-36P36 A-48P36 A-48P48 A-60P60

38

ACCESSORIES

39
ACCESSORIES

INTERCHANGEABLE UNIT HUBS

HUB ADAPTER PLATE (Converts 4 opening to 212) S8324

SMALL RL" OPENING (STANDARD)


SUFFIX SIZE 1 114
112

LARGE R OPENING (HEAVY DUTY)


SUFFIX SIZE 3 312 4 MILBANK NO.

REMOVABLE HUB CLOSING PLATE


DESCRIPTION SUFFIX STANDARD (for -RL opening) LARGE (for -R opening) CAT. #

MILBANK NO.

WL YL ZL DL EL

2 212

A7514 A7515 A7516 A7517 A7518

F G H

A8110 A8111 A8112

-XL -X

A7551 A9064

CLOSING COVERS HUB SUFFIX CHART


Plain Top Small Hub Opening Large Hub Opening Small Closing Plate Large Closing Plate Large Hub Opening RXL adapted to small Closing Plate METER CLOSING PLATE (Ring type / Ringless) 6003 (Gray Plastic) 6116 (Clear Plastic) METAL CLOSING PLATE (For Ringless sockets) CP-21 (For Ring type sockets) MCP Large Hub Opening RRL adapted to small Hub Opening

O RL R XL X

WL 1 For -RL Opening YL 114 For -RL Opening ZL 112 For -RL Opening DL 2 For -RL Opening EL 212 For -RL Opening 3 For -R Opening F G H
312 4 For -R Opening For -R Opening

CONNECTOR KITS
For use with 3/8-16 stud type units only SINGLE TWIN
SUFFIX CATALOG #

(3 per set) - 1

K1 K3 K3L
SUFFIX

K1539 K1540 K1540L


CATALOG #

6-350 4-600 or (2) 1/0-250 4-600 or (2) 1/0-250 Non-rotating


(4 per set) - 3

SUFFIX CATALOG #

(3 per set) - 1

K2 K2L K4 K6 K8

K1350 K1350L K1541 K3442 K3083

6-350 6-350 Non-rotating 4-600


(4 per set) - 3

K5 K7

K3082 K3441

6-350 4-600 or (2) 1/0-250

SUFFIX CATALOG #

6-350 4-600

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

39

40
ACCESSORIES

ACCESSORIES

FIFTH TERMINALS
Consult factory for 5th terminal selection

SEALING RINGS

100-200 amp PLUG-IN FIFTH TERMINAL 5T8K2

HEAVY DUTY JAW CLAMPING K3865 (K3866 w/out neutral wire)

SNAP ACTION MR-2 STAINLESS STEEL MR2-SS

SCREW TYPE (Stainless Steel) MR-4

LOAD TAP CONNECTORS (3 per set)

200 amp FIFTH TERMINAL K5T (New style block with square hole) Replaces the load side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 Includes Safety Barrier Extensions for applications over 300 VAC.

BYPASS LINK

K4977-INT INTERNAL HEX

K5022-INT INTERNAL HEX

DISCONNECT SLEEVE *
K8180 (Bypass links sold in pairs)
M5-144 (*NOT TO BE USED WITH LEVER BYPASS SOCKETS)

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

40

UQFP PLUGIN SERIES CIRCUIT BREAKERS

41
UQFP PLUGIN SERIES CIRCUIT BREAKERS

UQFP

UQFP-M

200 AMP FRAMEPLUG-IN10,000 AIC & 22,000 AIC TWO-POLECOMMON TRIP


AMPS 100 125 150 175 200

10K AIC PLUG-IN


UQFP-100 UQFP-125 UQFP-150 UQFP-175 UQFP-200

22K AIC PLUG-IN


UQFPH-100 UQFPH-125 UQFPH-150 UQFPH-175 UQFPH-200

10K AIC PLUG-IN

22K AIC PLUG-IN

WIRE RANGE CU
#3-#1 #3-#1 1/0-300 1/0-300 1/0-300

AL
#1-1/0 #1-1/0 2/0-300 2/0-300 2/0-300

UQFP-M-100 UQFPH-M-100 UQFP-M-125 UQFPH-M-125 UQFP-M-150 UQFPH-M-150 UQFP-M-175 UQFPH-M-175 UQFP-M-200 UQFPH-M-200

UL LISTED: For use with 60C or 75C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAGING: 5 units per 16 lb. carton.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

41

42
UQFB BOLTON SERIES CIRCUIT BREAKERS

UQFB BOLTON SERIES CIRCUIT BREAKERS

UQFB-X1

UQFB-X

UQFB

UQFB-X-MOD

200 AMP FRAMEBOLT-ON10K AIC & 22K AIC TWO-POLECOMMON TRIP


AMPS 100 125 150 175 200

10K AIC BOLT-ON


UQFB-100 UQFB-125 UQFB-150 UQFB-175 UQFB-200

22K AIC BOLT-ON

10K AIC BOLT-ON

WIRE RANGE CU
#3-#1 #3-#1 1/0-300 1/0-300 1/0-300

AL
#1-1/0 #1-1/0 2/0-300 2/0-300 2/0-300

UQFBH-100 UQFB-100-X1 UQFBH-125 UQFB-125-X1 UQFBH-150 UQFB-150-X1 UQFBH-175 UQFB-175-X1 UQFBH-200 UQFB-200-X1

UL LISTED: For use with 60C or 75C wire. UQFB: (2) 1/0-300 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB3: Three pole available. Consult factory. UQFB-X: (2) 1/0-300 kcmil lugs provided on load side and (2) line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB-X-MOD: Replacement circuit breaker with line barriers removed. STANDARD PACKAGING: 5 units per 16 lb. carton.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

42

CONDUIT, AMPACITY & SCCR INFORMATION


MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT*
TYPE CONDUCTOR SIZE AWG,MCM
14 12 10 8
6 3

43
CONDUIT, AMPACITY & SCCR INFORMATION

*CU

AL

or

Cu-Clad AL

CONDUIT TRADE SIZES (INCHES)


1

B
20 25 35 50
65 85 100 115 130
150 175 200 230

A
12 10 8
6 4 3 2 1
1/0 2/0 3/0 4/0

C
20 30 40
50 65 75 90 100
120 135 155 180

1
16 13 11 5
3 2

114 112
29 24 19 10
7 4

2
65 53 43 22
16 10

212
93 76 61 32
23 15

312

RHW & RHH (without outer covering) THW

6 4 4 1
1 1

10 8 6 3
2 1

40 32 26 13
10 6

143 192 117 157 95 127 163 49 66 85


36 23 48 31 62 40

18 16 14 12 10 8
6 4 3 2 1
1/0 2/0 3/0 4/0

TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW

1/0 2/0 3/0 4/0

1 1 1

1 1 1 1

2 1 1 1

3 3 2 1

5 5 4 3

8 7 6 5

12 10 9 7

16 14 12 10

21 18 15 13

250 300 350 400 500


600 700 750

1 1

1 1 1 1 1

1 1 1 1 1
1 1 1

2 2 1 1 1
1 1 1

4 3 3 2 1
1 1 1

6 5 4 4 3
3 2 2

8 7 6 5 4
4 3 3

10 9 8 7 6
5 4 4

250 300 350 400 500


600 700 750

255 285 310 335 380


420 460 475

250 300 350 400 500


600 700 750

205 230 250 270 310


340 375 385

*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.

* Allowable ampacities of insulated


Copper & Aluminum conductors (3W in conduit) 75C (167F) Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 310-16)
Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75 C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code.

AMPACITY CORRECTION FACTORS


AMBIENT TEMP.C 21 - 25 26 - 30 31 - 35 36 - 40 41 - 45 46 - 50 51 - 55 56 - 60 61 - 65 66 - 70 CORRECTION FACTOR 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 AMBIENT TEMP.F 70 - 77 79 - 86 88 - 95 97 - 104 106 - 113 115 - 122 124 - 131 133 - 140 142 - 158 160 - 176

GANG SOCKET OVERALL AMPACITIES


NO. OF METER POSITIONS 100A / POS. AMPACITY 125A / POS. AMPACITY 150A / POS. AMPACITY 200A / POS. AMPACITY

2 3 4 5 6

200A 200A 200A 225A 270A

200A 225A 250A 285A 330A

200A 225A 270A 338A 396A

200A 270A 360A 450A 528A

All meter sockets are 600 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted.

43

44
ENERGIZATION OF ELECTRICAL EQUIPMENT

ENERGIZATION OF ELECTRICAL EQUIPMENT

IMPORTANT NOTE
In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.

BEFORE ENERGIZING
A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization.

WHEN ENERGIZING
A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

AFTER ENERGIZING
A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* NOMINAL SIZE


10 10 10 12 12 1/4 1/4 5/16 5/16 3/8 1/2

JOINT DESCRIPTION SCREW


BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL

HEAD TYPE
ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX

NUT
Brass Nut or Extruded Hole CU or AL Busbar <1/8
Steel Nut or EH; CU or AL Busbar >1/8

TORQUE ( INCH LBS. )


20-25 in. lbs. 25-30 in. lbs 30-35 in. lbs 30-35 in. lbs 40-50 in. lbs. 40-50 in. lbs. 50-60 in. lbs. 60-70 in. lbs. 100-150 in. lbs. 150-200 in. lbs. 200-250 in. lbs.

Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum

44

MATERIALS AND FINISHES

45
MATERIALS AND FINISHES

MATERIALS
STEEL QUALITY
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.

STEEL SHEET
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

ALUMINUM EXTRUSION
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-o & 6063-O

ALUMINUM SHEET
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 .125

COPPER SHEET & BUS


Electrolytic copper with tin plating in most applications.

INSULATING MATERIALS
In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.

FINISH
PROCESS
Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.

METAL FASTENERS
Zinc-coated with a chromate dip.

RATING
NEMA RATING
Milbank meter sockets, CT cans and meter socket / breaker units have a type 3R rating.

45

46
METER FORMS

METER FORMS

DIAGRAM A
12W with 1 P.T. & 1 C.T. Single Stator Meter(2W1) Form 3S 5T Socket, Test Switch #TS04-0101
DIAGRAM A

DIAGRAM B
13W with 1 C.T. Single Stator Meter(2W1) Form 3S 5T Socket, Test Switch #TS04-0101
DIAGRAM B

DIAGRAM C
13W with 2 C.T.s Single Stator Meter(3W1) Form 4S 6T Socket, Test Switch #TS07-0105
DIAGRAM C

DIAGRAM D
13W or 3W Network with 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105

DIAGRAM D

(ALT.LOC.)

(ALT.LOC.)

P1 PN

+ C1

C1

P1 P N

+ C1

C1

P1 P2

+ C1

+ C2

+ C2 C2

P1 P2 PN

+ C1

C1

+ C2 C2

P.T. + I LINE N
(BONDED) +

+ +

+
C.T. C.T. +
LINE

C.T.

LOAD

LINE 2 N

C.T.

LOAD
LINE

(BONDED)

I N(BONDED) 2

+ +
LOAD

I N(BONDED) 2

+
C.T.

+
C.T.

LOAD

DIAGRAM E
33W with 2 P.T.s & 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105
DIAGRAM E

DIAGRAM F
33W with 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105
DIAGRAM F

DIAGRAM G
34W Y with 3 C.T.s 2 12 Stator Meter Form 6S 13T Socket, Test Switch #TS10-0109
DIAGRAM G

DIAGRAM H
34W Y with 2 P.T.s & 3 C.T.s 2 12 Stator Meter Form 6S 13T Socket, Test Switch #TS10-0109
DIAGRAM H

P1
P1 P3

P3 PN C+

C+ C

C+ C

P1

P3 PN

C+

C+

C+

P2 C+ 1

C1

+ C3 C3

P1 P3

P2 C+ 1

C1

+ C3 C3

+
PT

+
PT

PT

PT

+ +

+
C.T.

+ +
C.T. LOAD

1 LINE 2 3

1 LINE 2 3

+
C.T.

+
C.T.

LOAD

1 2 LINE 3 N

+ +
C.T.

+
C.T.

+ +
C.T.

+ +
C.T.

LOAD

(BONDED)

1 2 LINE 3 N(BONDED)

+ +
C.T.

+ +
C.T.

LOAD

DIAGRAM I
34W Y or with 3 C.T.s Y 3 Stator Meter Form 9S 2 Stator Meter Form 8S 13T Socket, Test Switch #TS10-0109
DIAGRAM I

DIAGRAM J
34W Y with 3 P.T.s & 3 C.T.s 3 Stator Meter Form 9S 13T Socket, Test Switch #TS10-0109
DIAGRAM J

P1 P2 P3 PN

+ C

+ C

+ C C

P1 P2 P3 PN

C+

C+

C+ C

PREWIRING: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.

PT PT

PT

1 2 LINE 3 N(BONDED)

+
C.T.

+ +
C.T.

+ +
C.T.

LOAD

1 2 LINE 3 N(BONDED)

+ + + +

+ +

+ +
C.T.

+ +
C.T.

+ +
C.T.

LOAD

46

WATTHOUR METER FORMSSTANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED

47
WATTHOUR METER FORMSSTANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED

SC
2 and 3-WIRE FORMS 1S & 2S

SC
2 and 3-WIRE FORMS 1S & 2S with BYPASS

TR
2-WIRE FORM 3S 5th Term. 9 o'clock

TR
2-WIRE FORM 3S with BYPASS

TR
2-WIRE FORM 3S 5th Term.6 o'clock

TR
2-WIRE FORM 3S with BYPASS

SC
2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 9 o'clock

SC
2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 9 o'clock

SC
2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 6 o'clock

SC
2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 6 o'clock

TR
3-WIRE FORM 4S

TR
3-WIRE FORM 4S WITH BYPASS

SC
2 or 3 ELEMENT 34W Y or Y FORM 14S FORM 15S

SC
2 or 3 ELEMENT 34W Y or FORMS 14S & 15S with BYPASS

TR
2 ELEMENT 34W Y or Y FORM 7S FORM 24S with BYPASS

TR
2 ELEMENT 23W, 24W, 33W FORM 5S

TR
2 ELEMENT 23W, 24W, 33W FORM 5S with BYPASS

SC
2 ELEMENT 23W, 24W, 33W FORM 13S

SC
2 or 3 ELEMENT 23W, 24W, 33W FORM 13S with BYPASS

TR
2 or 3 ELEMENT 34W Y or Y FORM 9S FORM 8S

TR = TRANSFORMER RATED SC = SELF CONTAINED

TR
2 or 3 ELEMENT 34W Y or FORMS 8S & 9S with BYPASS

TR
2 ELEMENT 34W Y FORM 6S

TR
2 ELEMENT 34W Y FORM 6S with BYPASS

47

48
STANDARD NEMA CONFIGURATIONS

STANDARD NEMA CONFIGURATIONS

2 POLE3 WIREGROUNDING RECEPTACLES STRAIGHT BLADE WIRING DEVICES VOLTS CODE 15 AMPS
G

TWIST-LOCK WIRING DEVICES 50 AMPS


G

20 AMPS
G

30 AMPS
G W

15 AMPS
W

20 AMPS
W G

30 AMPS
W G

125V 5
G

W W

5-15R

5-20R
G

5-30R
G

5-50R
G

L5-15R
X G Y

L5-20R
X G Y

L5-30R
X G Y

250V 6
6-15R 6-20R
G

6-30R
G

6-50R
G

L6-15R
W G

L6-20R
W G

L6-30R
W G

277 VAC

7-15R

7-20R

7-30R

7-50R

L7-15R

L7-20R

L7-30R

3 POLE3 WIRESPECIAL APPLICATIONS STRAIGHT BLADE WIRING DEVICES VOLTS CODE 20 AMPS
W Y

TWIST-LOCK 20 AMPS
X W

30 AMPS
W

50 AMPS
W

30 AMPS
X W

125V 10 250V

10-20R

10-30R

10-50R

L10-20R

L10-30R

3 POLE4 WIREGROUNDING STRAIGHT BLADE WIRING DEVICES VOLTS CODE 15 AMPS


G Y X Y W W

TWIST-LOCK 50 AMPS
G

20 AMPS
G X

30 AMPS
G Y W X

20 AMPS
X

30 AMPS
X

125V 14 250V

G Y

G Y

14-15R

14-20R

14-30R

14-50R

L14-20R

L14-30R

2 POLE3 WIREGROUNDINGNEMA TRAILER

STRAIGHT BLADE VOLTS CODE 30 AMPS


G

125V TT

TT-30R

48

INDEX

49
INDEX

REC/MUNICIPAL CATALOG SKU INDEX BY PAGE #


SKU PAGE # SKU PAGE # SKU PAGE #

363010-CT3R . . . . . . . . . . . . . . . . . . 38 363016-CT3R . . . . . . . . . . . . . . . . . . 38 363610-CT3R . . . . . . . . . . . . . . . . . . 38 363612-CT3R . . . . . . . . . . . . . . . . . . 38 363616-CT3R . . . . . . . . . . . . . . . . . . 38 483616-CT3R . . . . . . . . . . . . . . . . . . 38 484812-CT3R . . . . . . . . . . . . . . . . . . 38 5T8K2 . . . . . . . . . . . . . . . . . . . . . . . . 40 6003 . . . . . . . . . . . . . . . . . . . . . . . . . 39 606013-CT3R . . . . . . . . . . . . . . . . . . 38 6116 . . . . . . . . . . . . . . . . . . . . . . . . . 39 A7514 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7515 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7516 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7517 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7518 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7551 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8110 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8111 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8112 . . . . . . . . . . . . . . . . . . . . . . . . 39 A9064 . . . . . . . . . . . . . . . . . . . . . . . . 39 CP-21 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1350 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1350L . . . . . . . . . . . . . . . . . . . . . . . 39 K1539 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1540 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1540L . . . . . . . . . . . . . . . . . . . . . . . 39 K1541 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3082 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3083 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3441 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3442 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3450 . . . . . . . . . . . . . . . . . . . . . . . . 33 K3865 . . . . . . . . . . . . . . . . . . . . . . . . 40 K5035 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5193 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5194 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5400-1450 . . . . . . . . . . . . . . . . . . . . 33 K5400-1450GB . . . . . . . . . . . . . . . . . 35 K5400-520GR . . . . . . . . . . . . . . . . . . 33 K5400-620 . . . . . . . . . . . . . . . . . . . . . 35 K5400-620GB . . . . . . . . . . . . . . . . . . 35 K5400-BRIDGE-1POS . . . . . . . . . . . 33 K5400-BRIDGE-2POS . . . . . . . . . . . 33 K5400-TT30 . . . . . . . . . . . . . . . . . . . 33 K5415 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5T . . . . . . . . . . . . . . . . . . . . . . . . . . 33 K8180 . . . . . . . . . . . . . . . . . . . . . . . . 40 M5-144 . . . . . . . . . . . . . . . . . . . . . . . 40 MCP . . . . . . . . . . . . . . . . . . . . . . . . . 39 MR-2 . . . . . . . . . . . . . . . . . . . . . . . . . 40 MR-2-SS . . . . . . . . . . . . . . . . . . . . . . 40 MR-4 . . . . . . . . . . . . . . . . . . . . . . . . . 40 NU8980-O-200-KK . . . . . . . . . . . . . . 28 NU8980-O-200-KK-LP . . . . . . . . . . . 28 NU8980-O-KK . . . . . . . . . . . . . . . . . . 28

NU8980-O-KK-LP . . . . . . . . . . . . . . . 28 NU8980-O-SF100-KK . . . . . . . . . . . . 28 NU8980-O-SF100-KK-LP . . . . . . . . . 28 S1890-XT . . . . . . . . . . . . . . . . . . . . . 26 S1891-XT . . . . . . . . . . . . . . . . . . . . . 26 S2674-XT . . . . . . . . . . . . . . . . . . . . . 26 S2690-XT . . . . . . . . . . . . . . . . . . . . . 26 S2777-XT . . . . . . . . . . . . . . . . . . . . . 27 S2811-XT . . . . . . . . . . . . . . . . . . . . . 27 S3831-XT . . . . . . . . . . . . . . . . . . . . . 26 S3912-XT . . . . . . . . . . . . . . . . . . . . . 26 U1079-R . . . . . . . . . . . . . . . . . . . . . . 11 U1748-O . . . . . . . . . . . . . . . . . . . . . . 29 U1779-RRL-K3-K2 . . . . . . . . . . . . . . 11 U1797-O-K3L-K2L . . . . . . . . . . . . . . 11 U1980-O . . . . . . . . . . . . . . . . . . . . . . . 5 U2161-XT . . . . . . . . . . . . . . . . . . . . . 25 U2228-XT . . . . . . . . . . . . . . . . . . . . . 25 U2229-XT . . . . . . . . . . . . . . . . . . . . . 25 U2594-X . . . . . . . . . . . . . . . . . . . . . . 12 U3499-RL . . . . . . . . . . . . . . . . . . . . . 13 U3499-XL-100 . . . . . . . . . . . . . . . . . . 13 U3849-O-2/200 . . . . . . . . . . . . . . . . . 29 U4031-O-2/200 . . . . . . . . . . . . . . . . . 18 U4322-O-5T9 . . . . . . . . . . . . . . . . . . 36 U4493-XL . . . . . . . . . . . . . . . . . . . . . 24 U4505-X . . . . . . . . . . . . . . . . . . . . . . 10 U4532-XL . . . . . . . . . . . . . . . . . . . . . . 6 U4540-XL . . . . . . . . . . . . . . . . . . . . . 37 U4542-XL . . . . . . . . . . . . . . . . . . . . . 37 U4544-XL . . . . . . . . . . . . . . . . . . . . . 37 U4546-XL . . . . . . . . . . . . . . . . . . . . . 37 U4548-XL . . . . . . . . . . . . . . . . . . . . . 37 U4549-XL . . . . . . . . . . . . . . . . . . . . . 37 U4702-X . . . . . . . . . . . . . . . . . . . . . . 10 U4834-XL-200-5T9 . . . . . . . . . . . . . . 21 U5059-X-2/200-K3L . . . . . . . . . . . . . 19 U5067-X-2/200 . . . . . . . . . . . . . . . . . 30 U5067-X-2/225 . . . . . . . . . . . . . . . . . 30 U5136-O . . . . . . . . . . . . . . . . . . . . . . 33 U5136-O-100S . . . . . . . . . . . . . . . . . 33 U5136-O-200S . . . . . . . . . . . . . . . . . 33 U5137-O . . . . . . . . . . . . . . . . . . . . . . 33 U5137-O-100S . . . . . . . . . . . . . . . . . 33 U5137-O-200S . . . . . . . . . . . . . . . . . 33 U5138-O . . . . . . . . . . . . . . . . . . . . . . 33 U5138-O-200S . . . . . . . . . . . . . . . . . 33 U5168-XTL-200 . . . . . . . . . . . . . . . . . 16 U5169-XTL-200 . . . . . . . . . . . . . . . . . 16 U5268-XTL-200 . . . . . . . . . . . . . . . . . 16 U5269-XTL-200 . . . . . . . . . . . . . . . . . 16 U5706-O-200S . . . . . . . . . . . . . . . . . 35 U5706-O-200S-KK . . . . . . . . . . . . . . 35 U5712-XL-200 . . . . . . . . . . . . . . . . . . 17 U7017-RL-TG . . . . . . . . . . . . . . . . . . . 7 U7018-XL-TG . . . . . . . . . . . . . . . . . . . 7

U7021-RL-TG . . . . . . . . . . . . . . . . . . . 5 U7040-RL-TG . . . . . . . . . . . . . . . . . . . 5 U7043-XL-TG . . . . . . . . . . . . . . . . . . . 6 U7487-RL-TG . . . . . . . . . . . . . . . . . . . 4 U7490-RL-TG . . . . . . . . . . . . . . . . . . . 4 U8144-XL . . . . . . . . . . . . . . . . . . . . . 13 U8303-O . . . . . . . . . . . . . . . . . . . . . . 31 U8436-O . . . . . . . . . . . . . . . . . . . . . . 31 U9550-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9551-RXL . . . . . . . . . . . . . . . . . . . . . 8 U9581-RXL-QG . . . . . . . . . . . . . . . . . . 9 U9647N-RL-200 . . . . . . . . . . . . . . . . 14 U9648-RL-100 . . . . . . . . . . . . . . . . . . 14 U9700-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9701-RXL . . . . . . . . . . . . . . . . . . . . . 8 U9800-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9801-RXL . . . . . . . . . . . . . . . . . . . . . 8 UAP5024-XL . . . . . . . . . . . . . . . . . . . 15 UC7237-RL . . . . . . . . . . . . . . . . . . . . 22 UC7449-XL . . . . . . . . . . . . . . . . . . . . 23 UC7545-RL . . . . . . . . . . . . . . . . . . . . 22 UQFB-100 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-100-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-125 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-125-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-150 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-150-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-175 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-175-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-200 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-200-X1 . . . . . . . . . . . . . . . . . . 42 UQFBH-100 . . . . . . . . . . . . . . . . . . . 42 UQFBH-125 . . . . . . . . . . . . . . . . . . . 42 UQFBH-150 . . . . . . . . . . . . . . . . . . . 42 UQFBH-175 . . . . . . . . . . . . . . . . . . . 42 UQFBH-200 . . . . . . . . . . . . . . . . . . . 42 UQFP-100 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-125 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-150 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-175 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-200 . . . . . . . . . . . . . . . . . . . . . 41 UQFPH-100 . . . . . . . . . . . . . . . . . . . 41 UQFPH-125 . . . . . . . . . . . . . . . . . . . 41 UQFPH-150 . . . . . . . . . . . . . . . . . . . 41 UQFPH-175 . . . . . . . . . . . . . . . . . . . 41 UQFPH-200 . . . . . . . . . . . . . . . . . . . 41 UQFPH-M-100 . . . . . . . . . . . . . . . . . 41 UQFPH-M-125 . . . . . . . . . . . . . . . . . 41 UQFPH-M-150 . . . . . . . . . . . . . . . . . 41 UQFPH-M-175 . . . . . . . . . . . . . . . . . 41 UQFPH-M-200 . . . . . . . . . . . . . . . . . 41 UQFP-M-100 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-125 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-150 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-175 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-200 . . . . . . . . . . . . . . . . . . . 41

49

50
ADDITIONAL MILBANK PRODUCTS

ADDITIONAL MILBANK PRODUCTS

Other quality products available from Milbank


COMMERCIAL ENCLOSURES
Effective June 26, 2006 Supercedes and cancels all previous Milbank lists. All prices listed within are subject to change without notice.

2007 PRICE LIST

MILBANK MFG. CO. ENCLOSURE GROUP


1601 South St. Louis Street Concordia, MO 64020 Tel: 660-463-0805 Fax: 660-463-7950 Toll Free: 1-877-483-5314 www.milbankmfg.com

In addition to your local utilitys meter mounting equipment, Milbank also manufactures supporting products, such as...

Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches
Contact your local distributor or go to www.milbankmfg.com to find additional product literature.
50

NOTES

51
NOTES

51

Meter Mounting Equipment & More!


Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches

REPRESENTATIVE

DISTRIBUTOR

MILBANK MFG. CO.


PO Box 419028 Kansas City, MO 64141-0028 Tel: 816-483-5314 Fax: 816-483-6357 Toll Free: 877-483-5314 www.milbankmfg.com

www.milbankmfg.com

REC 12/09 (WEB)

S-ar putea să vă placă și