MILBANK OVERVIEW
MILBANK OVERVIEW
Bill Martin
prising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you dont find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is
an important factor to remain competitive in todays electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the pastwith dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that...
TABLE OF CONTENTS
3
TABLE OF CONTENTS
SINGLE POSITION 125 AMP4 TERMINALRINGLESS/RING TYPE600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 200 AMP4 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 200 AMP4 TERMINALRING TYPE600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 200 AMP4, 5, & 7 TERMINALJAW CLAMPING LEVER BYPASSRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . 8 200 AMP5 TERMINALJAW CLAMPING LEVER BYPASSRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 320 AMP4 & 5 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 320 AMP4 TERMINALRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 320 AMP7 TERMINALSIDE WIREWAYRINGLESS600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 METER MAINS 100 AMP4 TERMINALRING TYPEMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 100 & 200 AMP4 TERMINALRINGLESSMETER MAINLOAD SIDE DISTRIBUTION . . . . . . . . . . . . . . . . . . . . . . . 14 200 AMP4 TERMINALRINGLESSMETER MAIN WITH BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 200 AMP4 TERMINALRINGLESSMETER MAIN22K AIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 200 AMP4 TERMINALRINGLESSMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 320 AMP4 TERMINALRINGLESSMETER MAINSIDE WIREWAYWITH BREAKERS . . . . . . . . . . . . . . . . . . . 18-19 200 AMP4 TERMINALRING TYPEMETER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 200 AMP4 & 5 TERMINALRINGLESSMETER MAINJAW CLAMPINGAUXILIARY POWER CENTER . . . . . . . . 21 CT RATED 20 AMP13 TERMINALRINGLESS/RING TYPETRANSFORMER RATED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 20 AMP13 TERMINAL RINGLESSTRANSFORMER RATED600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 20 & 80 AMP13 TERMINALRINGLESSJAW CLAMPING LEVER BYPASSTRANSFORMER RATED . . . . . . . . . . 24 400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET PTS, DONUT OR BAR TYPE . . . . . . . . . . . . . . . 26 12001600 AMPMAXITRANSOCKET WITH PTS AND BAR TYPE CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 PEDESTALS/METER MAINS 100/200 AMP4 TERMINALMETER MAIN PEDESTAL1120/240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 320 AMP4 TERMINALMETER PEDESTAL WITH LEVER BYPASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 480 AMP CONTINUOUS4 TERMINALK SERIES METER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 100/200 AMP4 TERMINALRESIDENTIAL PEDESTALSINGLE OR DOUBLE POSITION13W600VAC . . . . . . 31 200 AMPRINGLESSMETERED PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33 U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS/RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 34-35 200 AMP4 TERMINALMOBILE HOME METER PEDESTALSRINGLESS120/240VAC . . . . . . . . . . . . . . . . . . . . . 36 100, 200 & 400 AMPTERMINAL BOX1 & 3120/240 VOLT600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 ENCLOSURES CT3R CURRENT TRANSFORMER CABINET/PANEL ENCLOSURETYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MISCELLANEOUS ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 UQFP PLUGIN SERIES CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 UQFB BOLTON SERIES CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 CONDUIT & AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 METER FORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 WATTHOUR METER FORMSSTD FORMSTRANSFORMER RATED OR SELFCONTAINED . . . . . . . . . . . . . . . . 47 STANDARD NEMA CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ADDITIONAL MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
4
125 AMP4 TERMINALSINGLE POSITIONRINGLESS / RING TYPE600 VAC
1 4 3 4
5 6
2
7487
5
1 4 3 4
6
2
7490
U7487-RL-TG
U7490-RL-TG
CONCENTRIC K.O.S 1 1
1
W" 8
H" 11
1
2 1
1
3 2
4 114
6
1
16
CONCENTRIC K.O.S 1 1
1
W" 8
H" 11
1
2 112
3 2
4 114
6
1
16
FIFTH TERMINAL: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round opening at the 9 oclock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: Ring type units supplied with an MR-2 snap action sealing ring as standard. BYPASS: Horn type bypass is available. Add suffix -KK to U7487.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
5
200 AMP4 TERMINALRINGLESS600 VAC
2
7040 7021
4
5 5
3
6
U7040-RL-TG
2
1980
U1980-O
CONCENTRIC K.O.S 1 2 2 2
1 1 1
2 2 2 2
1 1 1
3 2 2
1 1
4 2
1
5
1 1 4, 2
6
1
4 4 4
1 1 1
8 8 2
11 8 13
15 15 15
1 1 1
2 2 4
2 2 2
2 2 2
2 2
2 2
1
1
4 2
1 1 4, 2
1 1 4, 2
FIFTH TERMINAL: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 oclock position. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. BYPASS: Horn type bypass is available. Add suffix -KK to catalog number .
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
6
200 AMP4 TERMINALRINGLESS600 VAC
2
4532 7043
4
5 5
3
6
U4532-XL
U7043-XL-TG
LOAD
DUAL #6-350
CONCENTRIC K.O.S 1 2 2
1 1
2 2 2
1 1
3 3 3
4 3 3
5
1 1
6
1 1 4, 2
4 4
7 7
8 8
15 13
20 15
1 1
2 2
2 2
2 2
4 4
#6-350
1 1 4, 2
FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
7
200 AMP4 TERMINALRING TYPE600 VAC
7017
1
U7017-RL-TG
2
U7018-XL-TG
7018
4
5
3
6
CONCENTRIC K.O.S 1 2 2
1 1
2 2 2
1 1
3 2 2
1 1
4 2
1
5
1
6
1 1 4, 2
4 4
1 1
8 8
8 11
15 15
1 1
2 2
2 2
2 2
2 2
1 1 4, 2
HUBS: For proper hub selection see the hub suffix chart below or accessory section. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum internal hex lay-in type connectors are tin plated. Units are supplied with duplex neutral. TRIPLEX GROUND (-TG): Factory installed. SEALING RINGS: Ring type units are supplied with MR-2, snap action, sealing rings as standard.
SUFFIX
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
8
200 AMP4, 5 & 7 TERMINALSINGLE POSITIONRINGLESS JAW CLAMPING LEVER BYPASS600 VAC
200 AMP4, 5 & 7 TERMINALSINGLE POSITIONRINGLESS JAW CLAMPING LEVER BYPASS600 VAC
U9701-RXL
U9800-RRL
U9551-RXL
2
9550 9700
5
2
9800
2
9551 9701 9801
4
5
3
6
DIMENSIONS D" 4 4
7 7
CONCENTRIC K.O.S 1 3 3 2 2 2
1 1
W" 10 13
H" 18
1
3 3 3
5
1 1 4, 2
6
3
8 8
2 2
19
1 1 4, 2
DIMENSIONS D" 4 4
7 7
CONCENTRIC K.O.S 1 3 3 2 2 2
1 1
W" 10 13
H" 18
1
3 3 3
5
1 1 4, 2
6
3
8 8
2 2
19
1 1 4, 2
DIMENSIONS D" 4 4
7 7
CONCENTRIC K.O.S 1 3 3 2 2 2
1 1
W" 10 13
H" 18
1
3 3 3
5
1 1 4, 2
6
3
8 8
2 2
19
1 1 4, 2
HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: Lever supplies clamping action and also operates bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. U9550 and U9551 units are supplied with duplex neutral, with removable bonding strap for insulated neutral. U9700 series units are supplied with duplex neutral.
200 AMP5 TERMINAL SINGLE POSITION JAW CLAMPING LEVER BYPASS RINGLESSS600 VAC
9
200 AMP5 TERMINAL SINGLE POSITION JAW CLAMPING LEVER BYPASS RINGLESSS600 VAC
2
9581
4
5
3
6
U9581-RXL-QG
CONCENTRIC K.O.S 1 3 2 2
1
3 3
4 3
5
1
6
1 1 4, 2
U9581-RXL-QG C.P.
13
19
NEUTRAL DISCONNECT: The U9581 has a manual neutral disconnect bolt. HUBS: For proper hub selection, see hub suffix chart in Accessories. BYPASS: Lever supplies clamping action on meter spades and also operates 200 Amp continuous duty bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral, with removable bonding strap for insulated neutral.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
10
320 AMP4 & 5 TERMINALHEAVY DUTY LEVER BYPASSRINGLESS600 VAC
2
4702 4505
4
5
U4505-X
3
6
LOAD
3/8"-16 STUD 3/8"-16 STUD
CONCENTRIC K.O.S 1 3 3 2 3 3 3 3 3 4 3 3 5
1 1
6
1 1 4, 2
4 4
7 7
8 8
15 15
28 28
1 1
4 4
4 4
1 1 4, 2
HUBS: For proper hub selection see the hub suffix chart on the accessory page. LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: Stud type units supplied with 3/8"-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra K1539 (350 kcmil-1), K3082 (350 kcmil-3), K1540 (600 kcmil-1) or K3441 (600 kcmil-3). For twin lug connectors order as extra K1350 (350 kcmil-1) or K3442 (350 kcmil-3). Separate kits are required for both line and load.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
10
11
320 AMP4 TERMINALSINGLE POSITIONRINGLESS600 VAC
2
1797
1
3
5
2
1079
3
6
U1797-O-K3L-K2L U1079-R
CU/AL
LINE
CONCENTRIC K.O.S 1 3 3 3 2 2
1
3 3 3 3
4 3 3 3
5
1 1 1
6
1 1 4, 2
8"-16 STUDS
TWIN #6-350 3/8"-16 STUD
4 4 4
7 7 7
8 8 8
13 15 13
38
4 4
2 2
4 4 4
30 38
3
3 2
1
1 1 4, 2 1 1 4, 2
HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: Lever supplies clamping action and also operates bypass device on the U1079 & U1797. CONNECTOR KITS: Stud type units are supplied with 38"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. Order K1539 (single #350), K1540 (single #600) or K1350 (twin #350). See accessories page. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1079. Order as extra K3865 for U1797-0. LUG SIZE RANGE: See accessories page for lug size range for U1797 units.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
11
12
320 AMP7 TERMINALSINGLE POSITIONRINGLESS600 VAC
1 3
6
2
2594
U2594-X
BYPASS
LEVER
DIMENSIONS D" 6
1
CONCENTRIC K.O.S 1 2 3 3 4 4 4 5
1
W" 19
H" 34
1
6
1
8"-16 STUDS
2,34,1
BYPASS: Lever supplies clamping action on meter spades and operates bypass device. CONNECTOR KITS: Stud type units are supplied with 38"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. For single lug connector kits order as extra K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate kits are required for both line and load.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
12
13
100 AMP4 TERMINALMETER MAINSRINGLESS/RING TYPE
3499
4 5 3 6 4
2
8144
U3499-XL
U8144-XL
4 TERMINALMETER MAINRINGLESS13W
AMPS 100 100 SERVICE OH/UG OH/UG CATALOG NUMBER U3499-XL-100 U3499-RL HUB C.P. H.O.
CONNECTOR CU/AL
CONCENTRIC K.O.S 1 2 2 2 2 2 3 2 2 4 2 2 5 6
1 1 4, 2
#6-1/0 #14-1/0
334 33
11 11
22 22
1 1 4, 2
FIFTH TERMINAL: For field installed fifth terminal on U3499, order catalog number 5T8K2 (9 oclock position only). HUBS: For proper hub selection refer to the hub suffix chart on the Accessory page. FACTORY INSTALLED CIRCUIT BREAKERS: The U3499-XL-100 has a factory installed 2 pole 100 amp breaker.
CONCENTRIC K.O.S 1 2 2 2 3 2 4 2 5
1 1 4, 2
334
11
22
HUBS: For proper hub selection refer to the hub suffix chart on the accessory page. SEALING RINGS: Ring type units priced with MR-2 sealing ring. See accessory page for other choices. BREAKERS: The U8144 does not come with breakers unless specified on order and requires plug-in style.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
13
14
100 & 200 AMP4 TERMINALMETER MAINRINGLESS WITH LOAD SIDE DISTRIBUTION120 / 240 VAC
100 & 200 AMP4 TERMINALMETER MAINRINGLESS WITH LOAD SIDE DISTRIBUTION120 / 240 VAC
SUPPLIED WITH BREAKERS
3
6
9647
3
U9648-RL-100
3
5
9648
U9647N-RL-200
LOAD
CONCENTRIC K.O.S 1 2
1
2 2
1
3 2 3
4
1 1 4, 2
5
1 1
6
1 1 4, 2
8 8
8 13
26 33
4 4
U9647N-RL-200 H.O.
HUBS: For proper hub selection, refer to the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated with triplex on the load side. BREAKERS: Supplied with factory installed double pole circuit breakers of amperage shown. FIFTH TERMINAL: For field installed fifth terminal, order catalog number 5T8K2 for U9648. For U9647, order catalog number K5T.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
14
15
200 AMP4 TERMINALRINGLESSMETER MAIN WITH LOAD CENTER
1
5
7
1
5 6 5 6
2
5024
UAP5024-XL
HUB C.P.
CONNECTORS CU/AL
LINE #6-350
BYPASS
NONE
DIMENSIONS D" 4
1
CONCENTRIC K.O.S 1 2 2 2 3 3 4 2
1
W" 14
1
H" 24
5
1 3 1 2, 4,
6
1 3 2, 4
7
1 1 4, 2
OH/UG
BUSSING: Load side bus bars and circuit breaker interior are made from plated copper WIREWAY: Provided with underground pull section wireway with removable cover BREAKERS: Breaker section has provision for six double pole plug-in type circuit breakers. All circuit breakers will be parallel.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
15
16
200 AMPRING TYPE / RINGLESS METER MAINS4 TERMINAL22K AIC
1
5
2
6
U5168-XTL-200
U5268-XTL-200-KK
200 AMP4 TERMINALMETER MAIN22K AIC120/240 VOLT13WRINGLESS OVERHEAD / UNDERGROUND8 & 20 CIRCUIT INTERIOR
CIRCUITS 8 20 CATALOG NUMBER U5168-XTL-200 U5268-XTL-200 CONNECTORS HUB LINE C.P. C.P. #6-350 #6-350 DIMENSIONS BYPASS D" W" H"
NONE NONE
CONCENTRIC K.O.S 1 2 2 2 2 2 3 3 3 4 2 2
1 1
4 4
1 1
2 14 8 32 2 14 8 32
1
2 2
1 3 2, 4, 1 1 2 3 4
, ,
1 3 2, 4, 1 1 2 3 4
200 AMP4 TERMINALMETER MAIN22K AIC120/240 VOLT13WRING TYPE OVERHEAD / UNDERGROUND8 & 20 CIRCUIT INTERIOR
CIRCUITS 8 20 CATALOG NUMBER U5169-XTL-200 U5269-XTL-200 CONNECTORS HUB LINE C.P. C.P. #6-350 #6-350 DIMENSIONS BYPASS D" W" H"
NONE NONE
CONCENTRIC K.O.S 1 2 2 2 2 2 3 3 3 4 2 2
1 1
2 14 8 32 412 1418 32
4
2 2
1 3 2, 4, 1 1 2 3 4
, ,
1 3 2, 4, 1 1 2 3 4
HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. INTERIOR: U5168 units have 8-circuit interior; U5268 units have 20-circuit interior. FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oclock position only. BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN; order K5830 for small frame Q to small frame Q (100A version). SUB-FEED LUGS: #6-350 kcmil subfeed lugs provided on 8 and 10 circuit interior. Not available on 20 circuit interior. *Amperage rating limited to main breaker rating. Interior has 10 branch circuit breaker provisions on unit with 100 amp main.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
16
17
200 AMP4 TERMINALRINGLESS
U5712-XL-200
LOAD #6-350
4 -12
BREAKERS: Units are factory supplied with Milbank 200 amp plug-in type UQFP breaker. Other amperages available. When applicable, replace suffix with desired amperage (-100, -125, -150). BRANCE BREAKERS: (12) single-pole branch circuits available. FIFTH TERMINALS: Factory installed in 9 oclock position on U5712-XL-200-5T9. For field installed on U5712-XL-200 in 6 or 9 oclock position order kit K3865.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
17
18
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS
2
4031
U4031-O-2/200
BYPASS
CONCENTRIC K.O.S 1 3 2 3 3 4 4 3 5
1 1 4, 2
3 LEVER 5 4
CONNECTORS: The line wire section is supplied with 3/8"-16 studs with hex head nuts and captive Belleville washers. For single lug connector kits order as extra: K1539 (350 kcmil), K1540 (600 kcmil.) For twin: K1350 (350 kcmil.) BREAKERS: The U4031-O-2/200 is supplied with (2) bolt-on Milbank UQFB-200 breakers. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
18
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS
19
320 AMPSIDE WIREWAYMETER MAIN WITH (2) 200 AMP BREAKERSLEVER BYPASS
5059
LOAD
1/0-300
CONCENTRIC K.O.S 1 3 2 3 3 3 4
1
5
1 1 4, 2
15
42
NEUTRAL: Bonded neutral and ground factory Installed. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC Standard. BYPASS: Lever supplies clamping action and operates bypass device. FIFTH TERMINAL: For field installed fifth terminal order separately catalog number K3865.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
19
20
200 AMP7 TERMINALMETER MAINRINGLESS
5750
U5750-RXL-200-BL
7 TERMINALMETER MAINRINGLESS34W
AMPS 200 CATALOG NUMBER HUB
CONNECTOR CU/AL
LINE
53
17 3
8 34
4-3
2-2
HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. BREAKER: Factory installed 200 amp, 3-pole, 10,000 AIC
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
20
200 AMP4 & 5 TERMINAL300 VACMETER MAIN RINGLESSJAW CLAMPING LEVERAUXILIARY POWER CENTER
21
200 AMP4 & 5 TERMINAL300 VACMETER MAIN RINGLESSJAW CLAMPING LEVERAUXILIARY POWER CENTER
2
4834
3
6
U4834-XL-200-5T9
(Shown with optional 200 Amp Auxiliary breaker)
200 AMP4 & 5 TERMINAL (AT 9 OCLOCK)METER MAIN MANUAL TRANSFER SWITCHRINGLESS13W120/240 VAC
AMPS SERVICE 200 OH/UG CATALOG NUMBER U4834-XL-200-5T9 HUB
CONNECTOR CU/AL
LINE
BYPASS LOAD
DIMENSIONS D"
1
CONCENTRIC K.O.S 1 3 2 3 3 3 4 3 5
1 1 4, 2
W" 17
H" 39
AUXILIARY BREAKERS: Must be ordered separately. Use UQFP-(AMP) style breaker. FIFTH TERMINALS: For field installed fifth terminals, order catalog number K4935. Units with -5T9 suffix have fifth terminals factory installed in 9 oclock position.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
21
22
20 AMP13 TERMINALCURRENT TRANSFORMER RATEDRINGLESS / RING TYPE
3
5
UC7237 UC7545
UC7545-RL
UC7237-RL
HUB C.P.
BYPASS
PLUNGER
DIMENSIONS D" 3 16
5
CONCENTRIC K.O.S 1 11 2 11 3 11 4 2 5 11 6
1
W" 8
H" 14
HUB H.O.
BYPASS
PLUNGER
DIMENSIONS D" 3
5
W" 8
H" 14
16
HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Plunger type bypass automatically closes when meter is removed. CONNECTORS: Units are supplied with sleeve type connectors (#14-#2) NOTE: 5, 6, and 8 terminal sockets are also available.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
22
23
20 AMP13 TERMINALTRANSFORMER RATEDRINGLESS600 VAC
UC7449
5
6
UC7449-XL
DIMENSIONS D W 12 H 20 1 114
H.O.
#14 - #2 MAX
NONE 418
HUBS: For proper hub selection, see the hub suffix chart on the accessory page. SEALING RINGS: Ring type units are supplied with one MR2 snap-type sealing ring. PREWIRING: If standard factory prewiring is required, or custom factory prewiring is required, include meter socket catalog number, test switch model and number, meter form number and provide copy of your wiring diagram. SERVICE: Units are rated for overhead or underground service. NOTE: 5, 6, and 8 terminal sockets are also available.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
23
24
20 & 80 AMPTRANSFORMER RATED JAW CLAMPING LEVER BYPASSRINGLESS600 VAC
1 5 5
2
4993
U4493-XL
CONCENTRIC K.O.S 1 3 2 1
1
W 10
H 18
1
3
3
4
3
5 1
1
6
1
LEVER 4
BYPASS: Lever operates current bypass device and also supplies clamping action on current meter spades. TEST SWITCH COVERS: Units on this page can be used with clear lexan cover. See accessory page for ordering information. CONNECTORS: Units are supplied with mechanical type connectors (#4 max.) If compression type connectors (#10) are preferred, change catalog prefix to S (i.e. U4493-XL becomes S4493-XL.) The S also designates non-U/L. REMOVABLE HANDLE: When removable handle is desired add suffix -RH to catalog number (i.e. U4493-XL becomes U4493-XL-RH.) REPLACEMENT REMOVABLE HANDLE: When a replacement removable handle (RH) is required order part #Z706850-SC. Replacement handle will only work with factory ordered RH units. BLOCK ASSEMBLY: Block assembly rated at 80 amps-test switch rated at 20 ampstherefore, unit defaults to test switch rating of 20 amps. NOTE: 6 and 8 terminal sockets are also available.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
24
400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE C.T.S
25
400 AMP6, 8 & 13 TERMINALTRANSOCKET FOR USE WITH BAR TYPE C.T.S
U2161-XT
UNITS PRICED WITHOUT TRANSFORMERS OR TEST SWITCH. CONTACT GENERAL OFFICE FOR ORDERING INFORMATION. FOR USE WITH BAR TYPE C.T.S 200 / 5 300 / 5 400 / 5
2
2161
3
5
4 3
5
CONCENTRIC K.O.S 2 4 4 4 3 4 4 4 4 4 4 4 5 1 1 1
HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. STUDS: 1/2"-13 twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied. PREWIRING: If standard factory prewiring is required, refer to wiring diagrams in the general engineering section. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, be sure to specify test switch catalog number, meter form number and provide a copy of your wiring diagram. If C.T.s are to be factory installed, specify C.T. ratio. There is no provision for P.Ts in this unit. Contact factory for pricing.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
25
26
600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET P.T.S, DONUT OR BAR TYPE C.T.S600 VAC
600 AMP6, 8, 13 & 14 TERMINALCOMMERCIAL TRANSOCKET P.T.S, DONUT OR BAR TYPE C.T.S600 VAC
2 2
1891 3912 1890
1 3
1 3
1 3
2
3831 2690 2674
CONCENTRIC K.O.S 1 2 2
1
W" 18 18 18
H" 24 24 24
2 2 2
1
3 2 2
1
4 1 1 1
5
11
16 16 16
912 9 2
1
212 2 2
1
212 2 2
1
212 2 2
1
11
11
HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. PREWIRING: Units supplied prewired with test switch and transformers in place. Contact factory if wiring diagram is desired. PRICING: Contact general office for pricing information.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
26
27
1200-1600 AMPMAXI-TRANSOCKET WITH P.T.S AND BAR TYPE C.T.S480 VAC
S2777-4X
S2777-4X
2777
2
1
3
1
4
1
2 2
2 2
2 2
HUBS: Units are supplied with 4 closing plates as standard. To order hubs as extra refer to the hub suffix chart on the accessory page. PREWIRING: Units supplied with test switch and transformers in place. Contact factory if wiring diagram is desired. PRICING: Contact general office for pricing information.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
27
28
100 / 200 AMP1120 / 240 VAC4 TERMINALMETER MAIN PEDESTAL
MILBANK
1 2
Grade Line
NU8980-O-KK
CONNECTOR CU/AL
LINE
#6-350 #6-350 #6-350 #6-350 #6-350 #6-350
LOAD CB * CB *
#6-1/0 #6-1/0
BYPASS
HORN HORN HORN HORN
DIMENSIONS
D" 6 6 6 6 6 6 W" 9 9 9 9 9 9 H" 79 70 79 70 79 70
CONCENTRIC K.O.S
1 212 212 21
2 212 212 21
212 21
212 21
NU8980-O-200-KK NU8980-O-200-KK-LP
212
212
* FIELD INSTALLED CIRCUIT BREAKER REQUIRED. MAIN CIRCUIT BREAKERS: For 10K AIC order with factory installed main. For 22K AIC order pedestal without main and order circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit # K4714 and UQFP-M type circuit breaker. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers small frame plug-in type circuit breakers (Milbank, GE, Siemens, Cutler-Hammer, Murray). SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4 circuit interior. Only two single pole spaces available. FIFTH TERMINAL: For field installed 5th terminal order kit # 5T8K2. Mounts in 9 oclock position only. BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service. EXTENSION KIT: Available for low profile (-LP) units only. Order kit # K4694.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
28
29
320 AMP4 TERMINALMETER PEDESTAL WITH LEVER BYPASS
1
M I L B A N K
1 2 3
2
Grade Line Grade Line
Grade Line
Grade Line
4
18"
4 18"
13" O.D.
4-27/32" I.D.
16-15/16" 15"
U3849-O-2/200
U1748-O
BYPASS
DIMENSIONS D" 4
7
CONCENTRIC K.O.S 1 2
1
W" 13
H" 58
2 2
1
3
5
16
BREAKERS: The U3849 is furnished with (2) 200 amp Milbank type UQFBH-200 circuit breakers. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848. THIS UNIT IS RATED 22,000 AICSHORT CIRCUIT CURRENT RATING WITH MILBANK UQFBH SERIES CIRCUIT BREAKER.
BYPASS
16
CONNECTORS: The line wire section is supplied with 38"16 studs with hex head nuts and captive Belleville washers. The line side connectors are to be supplied by the Utility, load side is furnished. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order kit #K3865. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
29
30
480 AMP CONTINUOUS4 TERMINALK-SERIES METER MAIN
Rated for Overhead or Underground Service (Top Closing Plate Provided) 4 Terminal, 480 Amp Continuous, 13W Suitable for Service Entrance Two Main Circuit Breakers 225 Amp or 200 Amp (Twin Mains Allow Unit to Feed Multiple Panels)
G G G
CATALOG NUMBER
U5067-X-2/200 U5067-X-2/225
BREAKERS
Twin 200-Amp Breakers Twin 225-Amp Breakers
SPECIFICATIONS
G G G G G G G G G
Service Type: OH/UG (top closing plate included) Application: 1, 3W Self-Contained Type MS-K Watt-Hour Meters By-pass Device: Rated 50% Manual Type (Order Separately No. K4687) Cover Style: Sealable Ringless Meter Cover (both in-service and out-or-service positions) Line-Sided Connectors: Twin 350 kcmil Connectors Included Load-Side Connectors: Double 300 kcmil Connectors Included on Breakers Dimensions: 45"H X 24"W X 6"D Weight: 96 lbs. UL Listed
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
30
31
100 / 200 AMP4 TERMINALRESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION13W600 VAC
3 5
2 1 2
1
3
CHECHA
CHECHA MILBANK
2 2
GRADE LINE
2
4 2 4 5 6 6
18"
Grade Line
Grade Line
18.00
U8436-O
LINE
3
5
4
1
5 2 212
6
1 1 4, 2
200 2 POS-UG
4/0 (Line) BLANK 2/0 (Neutral) 4/0 (Line) BLANK 2/0 (Neutral)
4 4
1 1
62 74
16
2 8316
16
212
212
HANGING HOOK: Supplied with keyhole hanger for easy mounting. EXTENSION UNIT: For 24" burial applications, order extension unit S8988 for U8303-O. For 15" burial applications, order extension unit K5800 for U8436; for 30" applications, order (2) K5800 units. FIFTH TERMINAL: For field installed fifth terminal on U8436, order catalog number K5T (9 oclock position). For field installed fifth terminal on U8303-O, order catalog number 5T8K2 (9 oclock position). BYPASS: Horn type bypass used on both units.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
31
32
200 AMPRINGLESSMETERED PEDESTALS
SPECIFICATIONS
UL listed conforms to EUSERC drawing number 307 200 amp maximum, 120/240 volt, single phase, three wire meter socket Ringless meter socket with horn bypass and stainless steel latch Short circuit withstand rating 22K AIC. Type 3R construction for durable outdoor use, one piece post lockable and sealable Milbank grey polyester powder coat finish Wire terminations accept copper or aluminum conductors Line & Neutral: (2) #6-350 kcmil per phase Line Ground: (4) #14-1/0 Load (CB): 2/0 to 300 kcmil per pole Load Neutral: (1) #6-350 kcmil Load Ground: (2) #14-1/0, (4) #14/6 Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M. Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See Accessories.
32
33
200 AMPRINGLESSMETERED PEDESTALS
MAIN BREAKER
N N
MAIN CB
100 200
BRANCH
4 Circuit 4 Circuit 4 Circuit
WEIGHT (lbs)
82 82 80
MAIN BREAKER
(2) UQFPH-M-100 (2) UQFPH-M-200
MAIN CB
100 200
BRANCH
4 Circuit 4 Circuit 4 Circuit
WEIGHT (lbs)
115 115 111
RECEPTACLE
5-20R Duplex GFI TT30R 14-50R
K5400-520GR K5400-TT30 K5400-1450 K5400-BRIDGE-1POS K5400-BRIDGE-2POS K5415 K5035 K5T K5193 K5194 K3450
N N N N N N N N N
Self-grounded one position receptacle bridge with hardware Self-grounded two position receptacle bridge with hardware Stabilizer Foot with hardware Pad Mount Kit with hardware for U5138/39 pad mount pedestals required 5th Terminal for 208y / 120 volt 3-wire service Bus kit to convert series-wired main breaker to parallel Wire kit to convert parallel-wired main breaker to series Telephone / CATV mounting bracket (mounts left or right)
Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. K5415 Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals require K5035 pad mount kit. Order separately.
N Stock item availability subject to prior sale.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
33
34
U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE
Concentric Knockouts A (4) = 1, 1-1/2, 2, 2-1/2 B (1) = 1-1/4, 1-1/2, 2 , 1 C (1) = 3/4 1 , 1/2 D (1) = /4 E (1) = 1 Solid
A
30-3/16
A A
19 13-1/4 8-1/2 D
U5706-O-200S
* (Shown with (2) K5400-520GR receptacles, K5400-BRIDGE-2POS & line side conductor installed.)
OPEN
3-1/2
SPECIFICATIONS
200 amp, 1, 120/240 volt, 22K AIC, underground service only. U5706 has Ringless meter socket available with or without horn bypass (-KK). U5707 has Ring type meter socket with MR-4 screw type meter ring. Suitable for use as service equipment, mobile home service equipment and temporary power service equipment. * Provisions for up to two Type 3R in-use receptacle kits. * Order receptacle and bridge kits separately. See ordering information. Direct burial pedestal suitable for free standing or structure mounted installation. Separate line and load wireways are removable, lockable and sealable for security. Left side is for utility connection. Right side is for customer underground load exit. Convenient knockouts in post for thru-wall load exit requirements. Type 3R enclosure constructed with type G90 galvanized steel. Repaintable light gray polyester powder coat finish. Wire terminations accept copper or aluminum conductors: Line & Neutral: #6-350 Ground: (4) #14-1/0. Main circuit breaker can be series or parallel connected. Universal 4 circuit branch 125 amp interior (up to (2) 2-pole) accepts most manufacturers plug-in type circuit breakers. See wiring diagram.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
34
35
U5706 & U5707 TEMP TO FINAL SERVICE PEDESTALRINGLESS / RING TYPE
Amps
200 200
Service
120/240 120/240
By-Pass
None Horn
Main Wired
Series Series
Branch Circuits
4 4
Weight LBS.
79 79
Up to two receptacle/circuit breaker kits can be field or factory installed. See below for ordering information. Contact factory for factory installed kits.
To increase pedestal height, order field-installed post extension kit K5708. For field installed fifth terminal in the 9 oclock position, order kit 5T9. For field converting from parallel to series wired, order kit K5194. For field converting from series to parallel wired, order kit K5193.
Amps/ Volts
20a 120v 20a 240v 20a 240v 50a 120/240v 50a 120/240v
NEMA Config
5-20R Duplex GFI 6-20R Simplex 6-20R Simplex 14-50R 14-50R
Circuit Breaker
20a 1p 20a 2p 20a 240v GFI 50a 120/240v 50a 120/240v GFI
Conductor
12 awg 12 awg 12 awg 8 awg 8 awg
Configuration
Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 4 Fig. 5 Fig. 6
N K5400-BRIDGE-1POS Self-grounded ONE position bridge with hardware and instructions. N K5400-BRIDGE-2POS Self-grounded TWO position bridge with hardware and instructions.
Receptacle kits include: receptacle, circuit breaker, connected wire, cover plate, mounting screws and instructions. Contact factory for other kits. NOTE: Receptacle grounding is provided by metal contact with bridge and pedestal. Be sure to torque all fasteners per torque requirements. N Stock item availability subject to prior sale. Non-stock items minimum order quantity required.
Fig. 1 K5400-520GR
Fig. 2 K5400-620
Fig. 3 K5400-620GB
Fig. 4 K5400-1450
Fig. 5 K5400-BRIDGE-1POS
Fig. 6 K5400-BRIDGE-2POS
Fig. 7 UQFPH-M-200
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
35
36
200 AMP4 TERMINALMOBILE HOME METER PEDESTALSRINGLESS120/240 VAC
41
/8"
55"
51 /2"
10" 21"
STABILIZER FOOT
12"
U4322
U4322-O
G.E. Q LINE
SQ-D
HQP / BR / WBJ
QUICKLAG P / BR / HQP
QN QP
MD MP
Q LINE HOMELINE
TWIN CIRCUIT METER BY- MOUNTING LINE CONNECTORS PROV. POSITIONS PASS TYPE CU/AL
SINGLE
LEVER
DESCRIPTION
Provisions for Main with Branch or Parallel Breakers
POST
#6 AWG-350 kcmil
LEVER BYPASS: Lever provides clamping action on meter spades and also operates bypass device. APPLICATION: The U4322 pedestals are suitable for use as service equipment or mobile home service equipment. K5081 / K3188 for direct burial application is included with unit. K5151 for pad mount application must be ordered as extra. BREAKERS: These units are wired as parallel mains and have provisions for six circuits: six single-pole or three double-pole breakers. Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for two 2-pole breakers or four 1-pole breakers in series. FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865 (neutral wire not provided) or K3866 (with neutral wire). Both may be installed in 6 oclock or 9 oclock position.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
36
100, 200 & 400 AMPTERMINAL BOX1 & 3120 / 240 VOLT600 VAC
37
100, 200 & 400 AMPTERMINAL BOX1 & 3120 / 240 VOLT600 VAC
U4540-XL
U4540 U4542
U4548 U4549
CONCENTRIC K.O.S 2 2 2 1
1
3 2 2 2
1
4 1 1 2
1
5
1 1 4, 2
3 3
1 1
1 1 4, 2 1 1 4, 2 1 1 4, 2
14
13
16 23
418 141316 23 5 5 15
1
114 3 3
212 3 3
212
1 1 4, 2
2 27
27
4 4
1512
1 1 4, 2
HUB: Standard hub opening on top with closing plate attached. FEATURES: UL Listed pad lockable Type 3R enclosure. 3 120/240V APPLICATION: Field installable 3 lug kit converts 1 unit to 3 unit.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
37
38
CT3RCURRENT TRANSFORMER CABINET / PANEL ENCLOSURETYPE 3R
Application Designed for use as a current transformer cabinet or panel enclosure For outdoor use to provide protection against rain, sleet, and snow, or indoor use to protect against dripping water Construction Enclosure and cover manufactured from 16 or 14 gauge G90U galvanized steel The doors are overlapping with no center post Continuous door hinge with stainless steel hinge pins Three point pad-lockable handle Panel mounting studs provided for optional back panels Drip shield top and seam free sides, front and back Finish ANSI 61 gray polyester powder coating over phosphatized G90U galvanized steel
CATALOG NO. 363010-CT3R 363016-CT3R 363610-CT3R 363612-CT3R 363616-CT3R 483616-CT3R 484812-CT3R 606013-CT3R
PRODUCT FAMILY CN3R CN3R CN3R CN3R CN3R CN3R CN3R CN3R
UPC # (7-84572) 18823 16181 17368 16185 18819 25707 16184 18252
CTN QTY 1 1 1 1 1 1 1 1
WXHXD 36 x 30 x 10 36 x 30 x 16 36 x 36 x 10 36 x 36 x 12 36 x 36 x 16 48 x 36 x 16 48 x 48 x 12 60 x 60 x 13
PANEL CAT. NO. A-36P30 A-36P30 A-36P36 A-36P36 A-36P36 A-48P36 A-48P48 A-60P60
38
ACCESSORIES
39
ACCESSORIES
MILBANK NO.
WL YL ZL DL EL
2 212
F G H
-XL -X
A7551 A9064
O RL R XL X
WL 1 For -RL Opening YL 114 For -RL Opening ZL 112 For -RL Opening DL 2 For -RL Opening EL 212 For -RL Opening 3 For -R Opening F G H
312 4 For -R Opening For -R Opening
CONNECTOR KITS
For use with 3/8-16 stud type units only SINGLE TWIN
SUFFIX CATALOG #
(3 per set) - 1
K1 K3 K3L
SUFFIX
SUFFIX CATALOG #
(3 per set) - 1
K2 K2L K4 K6 K8
K5 K7
K3082 K3441
SUFFIX CATALOG #
6-350 4-600
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
39
40
ACCESSORIES
ACCESSORIES
FIFTH TERMINALS
Consult factory for 5th terminal selection
SEALING RINGS
200 amp FIFTH TERMINAL K5T (New style block with square hole) Replaces the load side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 Includes Safety Barrier Extensions for applications over 300 VAC.
BYPASS LINK
DISCONNECT SLEEVE *
K8180 (Bypass links sold in pairs)
M5-144 (*NOT TO BE USED WITH LEVER BYPASS SOCKETS)
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
40
41
UQFP PLUGIN SERIES CIRCUIT BREAKERS
UQFP
UQFP-M
WIRE RANGE CU
#3-#1 #3-#1 1/0-300 1/0-300 1/0-300
AL
#1-1/0 #1-1/0 2/0-300 2/0-300 2/0-300
UQFP-M-100 UQFPH-M-100 UQFP-M-125 UQFPH-M-125 UQFP-M-150 UQFPH-M-150 UQFP-M-175 UQFPH-M-175 UQFP-M-200 UQFPH-M-200
UL LISTED: For use with 60C or 75C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAGING: 5 units per 16 lb. carton.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
41
42
UQFB BOLTON SERIES CIRCUIT BREAKERS
UQFB-X1
UQFB-X
UQFB
UQFB-X-MOD
WIRE RANGE CU
#3-#1 #3-#1 1/0-300 1/0-300 1/0-300
AL
#1-1/0 #1-1/0 2/0-300 2/0-300 2/0-300
UQFBH-100 UQFB-100-X1 UQFBH-125 UQFB-125-X1 UQFBH-150 UQFB-150-X1 UQFBH-175 UQFB-175-X1 UQFBH-200 UQFB-200-X1
UL LISTED: For use with 60C or 75C wire. UQFB: (2) 1/0-300 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB3: Three pole available. Consult factory. UQFB-X: (2) 1/0-300 kcmil lugs provided on load side and (2) line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB-X-MOD: Replacement circuit breaker with line barriers removed. STANDARD PACKAGING: 5 units per 16 lb. carton.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
42
43
CONDUIT, AMPACITY & SCCR INFORMATION
*CU
AL
or
Cu-Clad AL
B
20 25 35 50
65 85 100 115 130
150 175 200 230
A
12 10 8
6 4 3 2 1
1/0 2/0 3/0 4/0
C
20 30 40
50 65 75 90 100
120 135 155 180
1
16 13 11 5
3 2
114 112
29 24 19 10
7 4
2
65 53 43 22
16 10
212
93 76 61 32
23 15
312
6 4 4 1
1 1
10 8 6 3
2 1
40 32 26 13
10 6
18 16 14 12 10 8
6 4 3 2 1
1/0 2/0 3/0 4/0
TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW
1 1 1
1 1 1 1
2 1 1 1
3 3 2 1
5 5 4 3
8 7 6 5
12 10 9 7
16 14 12 10
21 18 15 13
1 1
1 1 1 1 1
1 1 1 1 1
1 1 1
2 2 1 1 1
1 1 1
4 3 3 2 1
1 1 1
6 5 4 4 3
3 2 2
8 7 6 5 4
4 3 3
10 9 8 7 6
5 4 4
*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.
A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 310-16)
Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75 C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code.
2 3 4 5 6
All meter sockets are 600 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted.
43
44
ENERGIZATION OF ELECTRICAL EQUIPMENT
IMPORTANT NOTE
In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.
BEFORE ENERGIZING
A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization.
WHEN ENERGIZING
A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.
AFTER ENERGIZING
A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.
HEAD TYPE
ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX
NUT
Brass Nut or Extruded Hole CU or AL Busbar <1/8
Steel Nut or EH; CU or AL Busbar >1/8
Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut
*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum
44
45
MATERIALS AND FINISHES
MATERIALS
STEEL QUALITY
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.
STEEL SHEET
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
ALUMINUM EXTRUSION
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-o & 6063-O
ALUMINUM SHEET
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 .125
INSULATING MATERIALS
In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.
FINISH
PROCESS
Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.
METAL FASTENERS
Zinc-coated with a chromate dip.
RATING
NEMA RATING
Milbank meter sockets, CT cans and meter socket / breaker units have a type 3R rating.
45
46
METER FORMS
METER FORMS
DIAGRAM A
12W with 1 P.T. & 1 C.T. Single Stator Meter(2W1) Form 3S 5T Socket, Test Switch #TS04-0101
DIAGRAM A
DIAGRAM B
13W with 1 C.T. Single Stator Meter(2W1) Form 3S 5T Socket, Test Switch #TS04-0101
DIAGRAM B
DIAGRAM C
13W with 2 C.T.s Single Stator Meter(3W1) Form 4S 6T Socket, Test Switch #TS07-0105
DIAGRAM C
DIAGRAM D
13W or 3W Network with 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105
DIAGRAM D
(ALT.LOC.)
(ALT.LOC.)
P1 PN
+ C1
C1
P1 P N
+ C1
C1
P1 P2
+ C1
+ C2
+ C2 C2
P1 P2 PN
+ C1
C1
+ C2 C2
P.T. + I LINE N
(BONDED) +
+ +
+
C.T. C.T. +
LINE
C.T.
LOAD
LINE 2 N
C.T.
LOAD
LINE
(BONDED)
I N(BONDED) 2
+ +
LOAD
I N(BONDED) 2
+
C.T.
+
C.T.
LOAD
DIAGRAM E
33W with 2 P.T.s & 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105
DIAGRAM E
DIAGRAM F
33W with 2 C.T.s 2 Stator Meter Form 5S 8T Socket, Test Switch #TS07-0105
DIAGRAM F
DIAGRAM G
34W Y with 3 C.T.s 2 12 Stator Meter Form 6S 13T Socket, Test Switch #TS10-0109
DIAGRAM G
DIAGRAM H
34W Y with 2 P.T.s & 3 C.T.s 2 12 Stator Meter Form 6S 13T Socket, Test Switch #TS10-0109
DIAGRAM H
P1
P1 P3
P3 PN C+
C+ C
C+ C
P1
P3 PN
C+
C+
C+
P2 C+ 1
C1
+ C3 C3
P1 P3
P2 C+ 1
C1
+ C3 C3
+
PT
+
PT
PT
PT
+ +
+
C.T.
+ +
C.T. LOAD
1 LINE 2 3
1 LINE 2 3
+
C.T.
+
C.T.
LOAD
1 2 LINE 3 N
+ +
C.T.
+
C.T.
+ +
C.T.
+ +
C.T.
LOAD
(BONDED)
1 2 LINE 3 N(BONDED)
+ +
C.T.
+ +
C.T.
LOAD
DIAGRAM I
34W Y or with 3 C.T.s Y 3 Stator Meter Form 9S 2 Stator Meter Form 8S 13T Socket, Test Switch #TS10-0109
DIAGRAM I
DIAGRAM J
34W Y with 3 P.T.s & 3 C.T.s 3 Stator Meter Form 9S 13T Socket, Test Switch #TS10-0109
DIAGRAM J
P1 P2 P3 PN
+ C
+ C
+ C C
P1 P2 P3 PN
C+
C+
C+ C
PREWIRING: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.
PT PT
PT
1 2 LINE 3 N(BONDED)
+
C.T.
+ +
C.T.
+ +
C.T.
LOAD
1 2 LINE 3 N(BONDED)
+ + + +
+ +
+ +
C.T.
+ +
C.T.
+ +
C.T.
LOAD
46
47
WATTHOUR METER FORMSSTANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED
SC
2 and 3-WIRE FORMS 1S & 2S
SC
2 and 3-WIRE FORMS 1S & 2S with BYPASS
TR
2-WIRE FORM 3S 5th Term. 9 o'clock
TR
2-WIRE FORM 3S with BYPASS
TR
2-WIRE FORM 3S 5th Term.6 o'clock
TR
2-WIRE FORM 3S with BYPASS
SC
2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 9 o'clock
SC
2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 9 o'clock
SC
2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 6 o'clock
SC
2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 6 o'clock
TR
3-WIRE FORM 4S
TR
3-WIRE FORM 4S WITH BYPASS
SC
2 or 3 ELEMENT 34W Y or Y FORM 14S FORM 15S
SC
2 or 3 ELEMENT 34W Y or FORMS 14S & 15S with BYPASS
TR
2 ELEMENT 34W Y or Y FORM 7S FORM 24S with BYPASS
TR
2 ELEMENT 23W, 24W, 33W FORM 5S
TR
2 ELEMENT 23W, 24W, 33W FORM 5S with BYPASS
SC
2 ELEMENT 23W, 24W, 33W FORM 13S
SC
2 or 3 ELEMENT 23W, 24W, 33W FORM 13S with BYPASS
TR
2 or 3 ELEMENT 34W Y or Y FORM 9S FORM 8S
TR
2 or 3 ELEMENT 34W Y or FORMS 8S & 9S with BYPASS
TR
2 ELEMENT 34W Y FORM 6S
TR
2 ELEMENT 34W Y FORM 6S with BYPASS
47
48
STANDARD NEMA CONFIGURATIONS
2 POLE3 WIREGROUNDING RECEPTACLES STRAIGHT BLADE WIRING DEVICES VOLTS CODE 15 AMPS
G
20 AMPS
G
30 AMPS
G W
15 AMPS
W
20 AMPS
W G
30 AMPS
W G
125V 5
G
W W
5-15R
5-20R
G
5-30R
G
5-50R
G
L5-15R
X G Y
L5-20R
X G Y
L5-30R
X G Y
250V 6
6-15R 6-20R
G
6-30R
G
6-50R
G
L6-15R
W G
L6-20R
W G
L6-30R
W G
277 VAC
7-15R
7-20R
7-30R
7-50R
L7-15R
L7-20R
L7-30R
3 POLE3 WIRESPECIAL APPLICATIONS STRAIGHT BLADE WIRING DEVICES VOLTS CODE 20 AMPS
W Y
TWIST-LOCK 20 AMPS
X W
30 AMPS
W
50 AMPS
W
30 AMPS
X W
125V 10 250V
10-20R
10-30R
10-50R
L10-20R
L10-30R
TWIST-LOCK 50 AMPS
G
20 AMPS
G X
30 AMPS
G Y W X
20 AMPS
X
30 AMPS
X
125V 14 250V
G Y
G Y
14-15R
14-20R
14-30R
14-50R
L14-20R
L14-30R
125V TT
TT-30R
48
INDEX
49
INDEX
363010-CT3R . . . . . . . . . . . . . . . . . . 38 363016-CT3R . . . . . . . . . . . . . . . . . . 38 363610-CT3R . . . . . . . . . . . . . . . . . . 38 363612-CT3R . . . . . . . . . . . . . . . . . . 38 363616-CT3R . . . . . . . . . . . . . . . . . . 38 483616-CT3R . . . . . . . . . . . . . . . . . . 38 484812-CT3R . . . . . . . . . . . . . . . . . . 38 5T8K2 . . . . . . . . . . . . . . . . . . . . . . . . 40 6003 . . . . . . . . . . . . . . . . . . . . . . . . . 39 606013-CT3R . . . . . . . . . . . . . . . . . . 38 6116 . . . . . . . . . . . . . . . . . . . . . . . . . 39 A7514 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7515 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7516 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7517 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7518 . . . . . . . . . . . . . . . . . . . . . . . . 39 A7551 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8110 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8111 . . . . . . . . . . . . . . . . . . . . . . . . 39 A8112 . . . . . . . . . . . . . . . . . . . . . . . . 39 A9064 . . . . . . . . . . . . . . . . . . . . . . . . 39 CP-21 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1350 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1350L . . . . . . . . . . . . . . . . . . . . . . . 39 K1539 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1540 . . . . . . . . . . . . . . . . . . . . . . . . 39 K1540L . . . . . . . . . . . . . . . . . . . . . . . 39 K1541 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3082 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3083 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3441 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3442 . . . . . . . . . . . . . . . . . . . . . . . . 39 K3450 . . . . . . . . . . . . . . . . . . . . . . . . 33 K3865 . . . . . . . . . . . . . . . . . . . . . . . . 40 K5035 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5193 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5194 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5400-1450 . . . . . . . . . . . . . . . . . . . . 33 K5400-1450GB . . . . . . . . . . . . . . . . . 35 K5400-520GR . . . . . . . . . . . . . . . . . . 33 K5400-620 . . . . . . . . . . . . . . . . . . . . . 35 K5400-620GB . . . . . . . . . . . . . . . . . . 35 K5400-BRIDGE-1POS . . . . . . . . . . . 33 K5400-BRIDGE-2POS . . . . . . . . . . . 33 K5400-TT30 . . . . . . . . . . . . . . . . . . . 33 K5415 . . . . . . . . . . . . . . . . . . . . . . . . 33 K5T . . . . . . . . . . . . . . . . . . . . . . . . . . 33 K8180 . . . . . . . . . . . . . . . . . . . . . . . . 40 M5-144 . . . . . . . . . . . . . . . . . . . . . . . 40 MCP . . . . . . . . . . . . . . . . . . . . . . . . . 39 MR-2 . . . . . . . . . . . . . . . . . . . . . . . . . 40 MR-2-SS . . . . . . . . . . . . . . . . . . . . . . 40 MR-4 . . . . . . . . . . . . . . . . . . . . . . . . . 40 NU8980-O-200-KK . . . . . . . . . . . . . . 28 NU8980-O-200-KK-LP . . . . . . . . . . . 28 NU8980-O-KK . . . . . . . . . . . . . . . . . . 28
NU8980-O-KK-LP . . . . . . . . . . . . . . . 28 NU8980-O-SF100-KK . . . . . . . . . . . . 28 NU8980-O-SF100-KK-LP . . . . . . . . . 28 S1890-XT . . . . . . . . . . . . . . . . . . . . . 26 S1891-XT . . . . . . . . . . . . . . . . . . . . . 26 S2674-XT . . . . . . . . . . . . . . . . . . . . . 26 S2690-XT . . . . . . . . . . . . . . . . . . . . . 26 S2777-XT . . . . . . . . . . . . . . . . . . . . . 27 S2811-XT . . . . . . . . . . . . . . . . . . . . . 27 S3831-XT . . . . . . . . . . . . . . . . . . . . . 26 S3912-XT . . . . . . . . . . . . . . . . . . . . . 26 U1079-R . . . . . . . . . . . . . . . . . . . . . . 11 U1748-O . . . . . . . . . . . . . . . . . . . . . . 29 U1779-RRL-K3-K2 . . . . . . . . . . . . . . 11 U1797-O-K3L-K2L . . . . . . . . . . . . . . 11 U1980-O . . . . . . . . . . . . . . . . . . . . . . . 5 U2161-XT . . . . . . . . . . . . . . . . . . . . . 25 U2228-XT . . . . . . . . . . . . . . . . . . . . . 25 U2229-XT . . . . . . . . . . . . . . . . . . . . . 25 U2594-X . . . . . . . . . . . . . . . . . . . . . . 12 U3499-RL . . . . . . . . . . . . . . . . . . . . . 13 U3499-XL-100 . . . . . . . . . . . . . . . . . . 13 U3849-O-2/200 . . . . . . . . . . . . . . . . . 29 U4031-O-2/200 . . . . . . . . . . . . . . . . . 18 U4322-O-5T9 . . . . . . . . . . . . . . . . . . 36 U4493-XL . . . . . . . . . . . . . . . . . . . . . 24 U4505-X . . . . . . . . . . . . . . . . . . . . . . 10 U4532-XL . . . . . . . . . . . . . . . . . . . . . . 6 U4540-XL . . . . . . . . . . . . . . . . . . . . . 37 U4542-XL . . . . . . . . . . . . . . . . . . . . . 37 U4544-XL . . . . . . . . . . . . . . . . . . . . . 37 U4546-XL . . . . . . . . . . . . . . . . . . . . . 37 U4548-XL . . . . . . . . . . . . . . . . . . . . . 37 U4549-XL . . . . . . . . . . . . . . . . . . . . . 37 U4702-X . . . . . . . . . . . . . . . . . . . . . . 10 U4834-XL-200-5T9 . . . . . . . . . . . . . . 21 U5059-X-2/200-K3L . . . . . . . . . . . . . 19 U5067-X-2/200 . . . . . . . . . . . . . . . . . 30 U5067-X-2/225 . . . . . . . . . . . . . . . . . 30 U5136-O . . . . . . . . . . . . . . . . . . . . . . 33 U5136-O-100S . . . . . . . . . . . . . . . . . 33 U5136-O-200S . . . . . . . . . . . . . . . . . 33 U5137-O . . . . . . . . . . . . . . . . . . . . . . 33 U5137-O-100S . . . . . . . . . . . . . . . . . 33 U5137-O-200S . . . . . . . . . . . . . . . . . 33 U5138-O . . . . . . . . . . . . . . . . . . . . . . 33 U5138-O-200S . . . . . . . . . . . . . . . . . 33 U5168-XTL-200 . . . . . . . . . . . . . . . . . 16 U5169-XTL-200 . . . . . . . . . . . . . . . . . 16 U5268-XTL-200 . . . . . . . . . . . . . . . . . 16 U5269-XTL-200 . . . . . . . . . . . . . . . . . 16 U5706-O-200S . . . . . . . . . . . . . . . . . 35 U5706-O-200S-KK . . . . . . . . . . . . . . 35 U5712-XL-200 . . . . . . . . . . . . . . . . . . 17 U7017-RL-TG . . . . . . . . . . . . . . . . . . . 7 U7018-XL-TG . . . . . . . . . . . . . . . . . . . 7
U7021-RL-TG . . . . . . . . . . . . . . . . . . . 5 U7040-RL-TG . . . . . . . . . . . . . . . . . . . 5 U7043-XL-TG . . . . . . . . . . . . . . . . . . . 6 U7487-RL-TG . . . . . . . . . . . . . . . . . . . 4 U7490-RL-TG . . . . . . . . . . . . . . . . . . . 4 U8144-XL . . . . . . . . . . . . . . . . . . . . . 13 U8303-O . . . . . . . . . . . . . . . . . . . . . . 31 U8436-O . . . . . . . . . . . . . . . . . . . . . . 31 U9550-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9551-RXL . . . . . . . . . . . . . . . . . . . . . 8 U9581-RXL-QG . . . . . . . . . . . . . . . . . . 9 U9647N-RL-200 . . . . . . . . . . . . . . . . 14 U9648-RL-100 . . . . . . . . . . . . . . . . . . 14 U9700-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9701-RXL . . . . . . . . . . . . . . . . . . . . . 8 U9800-RRL . . . . . . . . . . . . . . . . . . . . . 8 U9801-RXL . . . . . . . . . . . . . . . . . . . . . 8 UAP5024-XL . . . . . . . . . . . . . . . . . . . 15 UC7237-RL . . . . . . . . . . . . . . . . . . . . 22 UC7449-XL . . . . . . . . . . . . . . . . . . . . 23 UC7545-RL . . . . . . . . . . . . . . . . . . . . 22 UQFB-100 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-100-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-125 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-125-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-150 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-150-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-175 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-175-X1 . . . . . . . . . . . . . . . . . . 42 UQFB-200 . . . . . . . . . . . . . . . . . . . . . 42 UQFB-200-X1 . . . . . . . . . . . . . . . . . . 42 UQFBH-100 . . . . . . . . . . . . . . . . . . . 42 UQFBH-125 . . . . . . . . . . . . . . . . . . . 42 UQFBH-150 . . . . . . . . . . . . . . . . . . . 42 UQFBH-175 . . . . . . . . . . . . . . . . . . . 42 UQFBH-200 . . . . . . . . . . . . . . . . . . . 42 UQFP-100 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-125 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-150 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-175 . . . . . . . . . . . . . . . . . . . . . 41 UQFP-200 . . . . . . . . . . . . . . . . . . . . . 41 UQFPH-100 . . . . . . . . . . . . . . . . . . . 41 UQFPH-125 . . . . . . . . . . . . . . . . . . . 41 UQFPH-150 . . . . . . . . . . . . . . . . . . . 41 UQFPH-175 . . . . . . . . . . . . . . . . . . . 41 UQFPH-200 . . . . . . . . . . . . . . . . . . . 41 UQFPH-M-100 . . . . . . . . . . . . . . . . . 41 UQFPH-M-125 . . . . . . . . . . . . . . . . . 41 UQFPH-M-150 . . . . . . . . . . . . . . . . . 41 UQFPH-M-175 . . . . . . . . . . . . . . . . . 41 UQFPH-M-200 . . . . . . . . . . . . . . . . . 41 UQFP-M-100 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-125 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-150 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-175 . . . . . . . . . . . . . . . . . . . 41 UQFP-M-200 . . . . . . . . . . . . . . . . . . . 41
49
50
ADDITIONAL MILBANK PRODUCTS
In addition to your local utilitys meter mounting equipment, Milbank also manufactures supporting products, such as...
Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches
Contact your local distributor or go to www.milbankmfg.com to find additional product literature.