Sunteți pe pagina 1din 4

Single and three-phase STS from 32 to 4000 A protection for your critical applications

STATYS

More than 25 years of specialist experience


S  OCOMEC UPS has more than 25 years of experience in designing, producing and customising Static Transfer Systems.  As leader in multiple-source and multi bus architecture, SOCOMEC has installed thousands of STS systems in many sectors that have demonstrated their adaptability and high reliability.

I  nvesting more than 10 % of turnover in R&D, SOCOMEC has always incorporated new technologies to ensure optimum quality and performance. STATYS, the latest design in STS, is the 4th generation of SOCOMEC STS. It incorporates the most advanced technologies combined with long experience to guarantee seamless and reliable power transfers.

STATYS provides
H  igh reliability - Internal redundant design Flexibility and adaptability to various types of applications.  Compact design: saves up to 40 % of valuable space.  Operational security & ease of use  Remote data access in real time and from any location.  Full support and service.

Static Transfer Switch: user benefits


Supplied by two independent alternate sources, STATYS:  provides redundant power supply to mission critical loads,  increases the power supply availability by choosing the best power supply quality,  prevents fault propagation, allows easy extension and easy infrastructure design, ensuring high availability of the power supply to critical applications,  facilitates installation and maintenance procedures. STATYS also provides protection against: m  ain power source outage,  failures in the upstream power distribution system,  failures caused by faulty equipment supplied by the same source, operator errors.

Gamme 101 a

Your protection for

> Finance, Banking and


Insurance

> Healthcare sector > Telecom & Broadcasting > Industry > Power generation plants > Transport

80

Single and three-phase STS

STATYS

from 32 to 4000 A

High reliability - Internal redundant design


STATYS increases the overall availability of the system during abnormal events and programmed maintenance. It allows plant segmentation and intelligent fault management, therefore increasing the global uptime of the system. The SOCOMEC UPS STATYS range has been designed with the latest technology that provides internal fault tolerance. Other features include: redundant control system using double microprocessor control boards,  dual redundant power supplies for control boards,  individual control board with redundant power supply for each SCR path,  redundant cooling with fan failure monitoring, real-time  SCR fault sensing,  separation of main functions to prevent internal fault propagation, r obust internal field communication bus,  internal monitoring of sensors to ensure maximum system reliability, 2  4/7/365 real-time remote monitoring.

Flexibility Adaptability to various types of applications


Dual or single cord servers, linear or nonlinear loads, IT or electromechanics are just some of the load types that STATYS can supply. Wherever a smart power source is needed, whether for existing or new electrical plants, STATYS can be easily installed and efficiently supply the load. STATYS offers a wide range of three-phase systems that suits all types of applications and power supply systems. It is available in:  3 wires arrangement without neutral, -f or reduced cable costs, - for local zoning of the applications by using insulating transformers,  4 wires three-phase arrangement with neutral, with or without neutral pole switching, for every load, linear or non-linear, and with every power factor. Statys offers:  flexible digital control capacity that can adapt to any operational or electrical environment conditions, a dvanced Transformer Switching Management (ATSM).

MODE
ESC

1
OFF

2
LAMP

MODE
ESC

1
OFF

2
LAMP

MODE
ESC

1
OFF

2
LAMP

Operational security & ease of use


Statys is equipped with user-friendly interfaces and commands providing secured operating controls:  easy to read display with intuitive navigation, f  ront access to all information (measurements, status and alarms), - acoustic notification (buzzer) of abnormal events, - password protection capability, a  utomatically controlled interlock, preventing operator errors. Its ease of use will dramatically reduce operator errors.
staty 041 a

Advanced Transformer Switching Management


If the upstream network has no distributed neutral cable, two upstream transformers or one downstream transformer can be added to create a neutral reference point at the output. For the downstream solution, STATYS, thanks to ATSM, correctly manages the switching to limit inrush current and avoid the risk of spurious breakers.
STS Lamda
Output voltage

STATYS
Output voltage
STATY 039 A GB - STATY 042 A GB - STATY 043 A GB

Source 1

Source 2

Source 1

Source 2

Output current

Output current

STS

Source 1 Source 2

Load
Source 1 Source 2 Source 1 Source 2

Measurement point

81

STATY 037 A

TY A ST S

Single and three-phase STS

STATYS

from 32 to 4000 A

Compact design: saves up to 40% of valuable space


Statys has a very compact design reducing significantly its operational footprint. It saves highly valuable floor space and reduces space requirement in the PDU. Statys has been designed to save space and for easy maintenance:  small footprint,  adjacent or back to back mounting,  front access for easy maintenance procedures,  compact Hot Swap 19 rack system (the smallest on the market), Its high efficiency, its integrable chassis and its minimal footprint make Statys the best STS to be embedded into a PDU.

Remote data access in real time and from any location


Its advanced communication capabilities make Statys easily integrable in the existing monitoring and control infrastructures. Statys fulfils prerequisites for:  LAN connectivity and the customers Building Management System (BMS) integration,  remote connection for monitoring and maintenance,  plug and play modular communication ComSlot (interfaces for flexible upgrading),  programmable output dry contacts and insulated inputs,  serial communication ports.

STA TY

Full support and service


As with all equipment, the devices that supply power to your critical applications require regular maintenance to continue providing secure operation. Preventive maintenance helps avoid malfunctions and extends the life of your equipment as well as improving the MTBF (Mean Time Between Failures) of the installation. Real-time monitoring means prompt reaction to abnormal events for minimum MTTR (Mean Time To Repair). SOCOMEC UPS is on hand for the customer during the entire lifetime of the equipment and even more: s killed technicians available for telephone consultancy and site inspection, technical and specification documentation, worldwide seminars and follow-up meetings,  during a full commissioning service SOCOMEC technicians configure STATYS to be integrated with required monitoring systems.

Standard features
Redundant  Microcontroller board. Individual SCR control board with redundant local power supply.  Dual redundant electronic power supply.  Comprehensive SCR fault sensing.  Smart commutation system configurable according to the load.  Redundant cooling.  Fuse-free or fuse-protected design.  Output fault sensing.  Internal CAN Bus.  ot Swap 19-inch rack. H Double Maintenance bypass.  LCD and Graphical Mimic Panel.  Password control.  Full load parameter measurements.  Ethernet Network connection.  Front accessible components.  Full digital configuration and setting.  I/O Dry Contacts interfaces.  Flexible Com Slots. 

STATY 038 A

Options
 dditional Dry Contacts interface board. A RS232/485 serial port interface board.  Profibus interface.  Devicenet interface.  Automatic Maintenance Bypass interlock.  Voltage adaptation  TVSS.

82

Single and three-phase STS

STATYS

from 32 to 4000 A

19 rack - Hot Swap


SIZE [A] Voltage [V] Number of phases Frequency [Hz] Number of poles switching Neutral system Maintenance bypass Overload Efficiency Admissible power factor 32 63 120 -127 / 220 - 240/254 (10%) ph +N or ph-ph (+PE) 50 or 60 (configurable 5Hz) 2-pole switching compatible with all earthing systems interlocked and secured 110% for 60 minutes - 150% for 2 minutes 99% no restrictions 3 or 4-pole switching 63 100 208 - 220/380 - 415/440 (10%) 3ph +N or 3ph (+PE)

Cabinet - Integrable chassis (OEM)


Size [A] Voltage [V] Number of phases Frequency [Hz] Number of poles switching Neutral system Maintenance bypass Overload Efficiency Admissible power factor FROM 200 A TO 4000 A 208 - 220/380 - 415/440 (10%) 3ph +N or 3ph (+PE) 50 or 60 (configurable 5Hz) 3 or 4-pole switching compatible with all earthing systems interlocked and secured 110% for 60 minutes - 150% for 2 minutes 99% no restrictions

Dimensions and weight


Size [A] 19 RaCK WxDxH (mm) Weight (kg) CabiNet WxDxH (mm) Weight (kg) INteGRabLe Chassis (OEM) WxDxH (mm) Weight (kg) ENVIRONMENT Operating ambient temperature Degree of protection Relative humidity Maximum altitude Cooling Sound pressure level STANDARDS Performance and safety Protection class EMC class 1ph 3ph 32 63 63 100 200 300 400 600 500x600 x1930** 195 400x586 x765 70 700x600x1930** 270 600x586x765 105 0 - 40C IP 31 95% 1000m a.s.l. without derating forced ventilation 60dB(A) IEC 62310, EN 50022, IEC 60364-4, IEC 60950, IEC 60529, IEC 60439-1 CB or PC class C2 category (IEC 62310-2) IP 20 900x600 x1930 345 800x586 x765 130 contact us contact us contact us contact us FROM 800 A TO 4000 A

483x747x89 (19x747x2U)** 26 -

483x648x400 (19x648x9U)* 58

<45dB(A)

contact us

* Depth does not include handles (+40mm). Total height corresponds to 3U for fixed part and 6U for the Hot Swap module. - ** Depth does not include handles (+40mm).

dcG_84073

VALID FOR FRANCE

VALID FOR ITALY

www.socomec.com
ISO14001 EMS 553476

ISO 9001 FM 28237

Non contractual document. 2011, Socomec SA. All rights reserved.

83