Part 2. Hardware
1. Student keypad
For IR117/IR118/RF217/RF218
1.1. Specification
Dimension (l w h): 104mm x 49mm x15 mm Button: 16-for IR118 & RF218 7 - for IR117 & RF217 Power required: two AAA batteries Transmission distance: IR118 & IR117>15 meters RF218 & RF217>100 meters Transmission angle: IR118 & IR117> 30 degree RF218 & RF217: 360 degree Battery life: >2 years for ordinary use Function: transmit response signals
Each student keypad has a unique ID number. The ID number can be set or reset by the manager. This feature is very important, if one student keypad is lost or damaged and unfortunately it is in dire need of, dont worry, you can replace a spare remote by just setting or resetting the ID number.
indicator will appear in One by One mode. Working Mode indicator: The indicator pointing to first line means One by One mode; pointing to second line means Self -paced mode. The disappearing of the indicator means Homework mode. (Fore more details, please refer to Working Mode and Answer Type in item 4) Answer content: Display A-F or 0-100. Status Indicator: >>>: Signal is sending; OK: Signal has been sent by remoter and has been received by receiver; : error. Answer Type indicator: There are 3 types: A-F single, A-F multi and 0-100. 3- Key area (1) Clear display, and power on/off
Power on: press and the remote will enter one by one mode automatically, the LCD screen will display the ID No. of the remote, and the answer type will be the type chosen last time. Power off: press and hold for more than 3 seconds, the remote will be closed. It will turn off automatically if not been pressed for more than one hour. (2) >>>/OKIndicate signal sending or has been received successfully. (3) :It is used for choosing previous or next question under the self-paced
and homework mode. If we want to skip-to a given question number from No. 1 to No.100,we can just press Fn + key. (4) Remote ID setting we can pressFn+8and then cooperate with the ID setting software to set the ID No.. (5) Input A-F or 0-9: under the answer type of A-F single and A-F multi, we can input A-F. Under the answer type of 0-100, we can input 0-100. (6) Rush Quiz : The Buzz in / Rush Quiz only effective under one by one working
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 2
mode. Any of the three answer types can work. It cannot work under self-paced and homework working mode. 4- Describe about Working Mode and Answer Type (1) Working mode includes three modes: one by one (default working mode), self-paced and homework. How to switch between the three modes? There are two means: automatic switch and manual switch. Automatic switch: when the receiver is active, press >>>/OK key will adjust the working mode to the current right mode automatically. Manual switch: press Fn + 0/mode to switch between one by one and self-paced modes; press Fn + 9 to inter homework mode; furthermore, press Fn + >>>/OK will inter homework mode and begin to sending signals directly. Press Fn + 0/mode to exit homework mode and inter other modes. Under one by one mode, the first line in the LCD screen will display remote ID, the remote will only send answer signals every time. Under self-paced mode, the first line in the LCD screen will display question No., the remote will send both answer signals and question No. (2) Answer type includes three types: A-F single A-F Multi and 0-100. are two means of switch: automatic switch and manual switch. Automatic switch: when the receiver is active, press >>>/OK key will switch the answer type to the current right type automatically. Manual switch: press Fn + to switch between the three types. There
(3) Cooperation of working mode, answer type and software programs: The corresponding working mode of the software Quiz Master is one by one, under this mode, the answer type could be any one of the three: A-F Single, A-F Multi and 0-100. The corresponding working mode of the software Standard Exam is self -paced and homework. Under self-paced mode, the answer type could be A-F Single, A-F Multi and 0-100. Under homework mode, the answer type could only be A-F single.
Transmission angle: 360 degree Battery life: >1 year for ordinary use Function: transmit response signals Each student keypad has an ID number. The ID number can be set or reset by the manager. This feature is very important, if one student keypad is lost or damaged and unfortunately it is in dire need of, dont worry, you can replace a spare remote by just setting or resetting the ID number. 1- LCD screen (see as right) Display Remoter ID. Range:0000-9999 Input mode indicator: 12 means digital input; ab means lowercase letter input; AB means capital letter input. Remoter status indicator: means operation success; receiver signal. Question type indicator: It indicates the question types. (The detail is scribed in 3.The display and key input operation for all kinds of question types) Battery voltage indicator. Because the system is very low power consumption, it can still work for long time when low power is shown by the battery indicator. Question options and input answer display. 2- Key area There are 3 kinds of keys: function key, input key and key combination (1) Function key OK: For confirm and sending; CE: For cancel and back space; <,>: For select previous or next option, or select previous or next question : Input mode switch key; means input or modify status; >> means sending; means operation fail; OK __ means stop reply status;
: Rush key, for rush and hand-raise mode; Fn: Used combination with other keys.
(2) Input key: Include options input A-J , digital input 0-9, lowercase letters, capital letters input and symbol input. The input way is very like mobile phones. For example, when press the button B2, if input mode is blank, the option B or option 2 is input; if input mode is 12, the digital 2 is input; if input mode is ab, when stroke the button continually, the input content will cycle from a to b to c; if input mod is AB, when stroke the button continually, the input content will cycle from A to B to C. (3) Key combination: Fn + ON : Remoter power on. After power on, the remoter will search for receiver signal automatically, and keep synchronization with receiver. If fail, then display the error icon .
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 4
Fn + OFF : Remoter power off by hand. When power on, it will enter standby status if no any keystroke in 5 minutes; and it will power off automatically if no any keystroke in 30 minutes. Fn + CE: Clear all input content. Fn + 1: Jump to appointed question no in self-paced test mode. Fn +2: Search for receiver signal by hand. Fn + 3: Join to receiver in dynamic mode. (This function need new version software which support dynamic work mode) Fn + : Enter or exit short message status. (The remoter can not enter short message status until the system stopping replying questions) 3-The display and key input operation for all kinds of question types (1). Multiple-choice: x/n (Question type indicator display). n represents option number, x represents correct option number. x=1means single correct option, x=? means the correct option number is uncertain. The option code will display on LCD, which can be A-H or 1-8 (determined by software). When press option key, the corresponding option code will reverse video; press CE key, all answer will be cleared; if the number of options selected equal the appointed correct option number, press OK key, all answer will be sent to receiver. (Before complete sending, you can press CE to cancel sending action every time.) (2). Sort order: /n. The n represents option number, can from 1 to 9. The first line will display option code, and the second line will display sorted list. Input the option key (can not repeat input), the corresponding option code will move from line 1 to line 2 on the LCD. (3) Catalogue: ( )/n. The option code can only be A-J, n represents the last option code here. The catalogue groups display on LCD; press < and > key to select one group for input; press CE to clear on group, and press Fn + CE to clear all groups. (4) Fill up text: Txt. The input way is similar mobile pho ne. Up to 120 characters can be input each time. Press , switch input mode among digital, lower case and upper case (default
lower case) ; press < and > key, move the cursor left and right; press CE, backspace; press Fn + CE, clear all input. (5) Fill up number: 0~9. The input way is same as fill up text type. Up to 15 characters can be input each time. Press , switch input mode among digital, lower case and upper case(default key; press
digital) ; When input mode is digital, you can input fraction by press CE, backspace; press Fn + CE, clear all input.
(6) Self-paced mode: Qxx. xx represents current question no. Up to 15 characters can be input each question. Press , switch input mode among option input(the input indicator is blank), digital,
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 5
lower case and upper case(default option input); press < or > key to select previous question or next question; press Fn + 1, then input 2 digital numbers to jump to the appointed question. The input question no can not be bigger than maximum question no which set by software. (7) Register student ID: RSID. Up to 15 characters can be input to register student ID when doing roll call check. The input way is same as fill up number. (8) Short message: . The input way is same as fill up text. (9) Rush quiz: ***. The rush icon display on LCD. You can press key to send signal to receiver, no need press OK key. (10) Other question type: ***. Other question types include Vote for/Against, Right/Wrong, Yes/No, True/False and so on. The option content will display on LCD, You can press <, > or 1, 2, 3 key to select certain option, and then press OK to send it to receiver. 4- The relations between working mode/question type and software. The software standard exam only uses self-paced mode; the software quiz master uses all question types except self -paced mode; the software quiz freedom uses most question types except self-paced mode and some other question types.
2. Instructor Keypad
2.1. Specification
Dimension (l w h): 104mm x 49mm x15 mm Button: 13 Power required: two AAA batteries Transmission distance:IR118/IR117>15 meters, RF219/RF218/RF217>100 meters Transmission angle: IR118/IR117>30 degree, RF219/RF218/RF217: 360 degree Battery life: >1 year for ordinary use Function: it is used by the instructor to controlling the course of the activities, presenting the PPT files, displaying the result and reports.
2.2. Illustration
1 and 4 - Laser pointer 2 - Transmission window, it is used to transmit signal. 3 - Indicate light, it will turn on while the key is pressed. 5-Power, it used to start/stop the presentation of the PPT files and start/stop an activity. 6 Report, it is used to display the Score Board 7-Result, it is used to display the result. 8-Mode Switch, it is used to select activity mode in Multi Mode. 9-?, it is used to go to Feedback mode in Multi Mode.
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 6
10-Up and 15-Down, they are used control the present of the PPT files: page -up and page-down, forward and reverse. 11-OK, it is used to confirm something. 12- stop, it is used to stop gathering the response information of the audience remotes. 13-Start and pause, it is used to start gathering the response information of the audience remotes; when press again, it will be used to pause the timer while the receiver continues to gather information. 14-F2 and 16-F1, assistant function buttons
3. Receiver (RF219/RF218/RF217)
Receivers include main receiver and extensive receivers. Each set of ARS system includes one main receiver only, if more than 400 participants, the extensive receiver/receivers can be added to the system. Each receiver (includes main receiver and extensive receiver) supports 400 audience handsets. The receivers are alike, but they can be separated easily by the mark on their backsides.
3.2
Receiver
and
cable
connection
illustration
RF219/RF218/RF217
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 7
The connection is type A: Receiver port > cable >USB port of the computer. As shown as below: Both main receiver and extensive receivers of RF219 / RF218/RF217 are connected to the USB ports of the computer directly and separately.
4.1 Main Receiver IR118 & IR117 (USB port or 232 port)
. Specification Dimension (l w h): 5.40in. x 5.40in. x 1.38in Weight: 0.3kg Operating Temperature: 0-40 degree Operating Relative Humidity: 0-90% Power required: DC12V, 800MA adapter (for type B which with RS232 port) No adapter needed (for type A which with USB port) Operating Power: 5w Receiving angle: >280 degree Receiving distance: >20 meters radial Function: it is used to receive signals from the remotes, and send information to computer. . Illustration 1-screw, it can be use to fixed the receiver by bolts prepared. 2-RG45 Ports: We can use anyone of the three ports to connect the main receiver to the computer or the extension receivers. 3-power light, power on, turn red; power off, turn off 4-signal light, it will turn green when the receiver is enabled, or it is receiving IR signals. 5-shell, be careful to keep transparence. Do not cover.
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 8
5. Main cable, extension cable & USB cable (IR118 & IR117)
5.1 Main cable (USB port or 232 port, selective)
Main cable is used to connect the main receiver to the 232 COM or USB port of computer. If we use 232 COM port cable, and the COM port of the computer is used up, we can use USB convert RS232 cableselective. It has an adaptor port, which is connected to a DC12V, 800mA Power Adapter, as shown on the right:
If the COM port of the computer is used up, we can use USB convert RS232 cable to connect the main receiver to the computer.
below:
System Requirements:
One PC Intel Pentium II or higher processor One USB port or COM port 9Pin RS-232 if needed A minimum of 64 MB RAM At least 100 MB of hard drive space for software Microsoft Windows Me/2000/xp/vista/Windows 7 Microsoft Office 2000 or higher (The security level of PowerPoint should be set to
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 10
medium) Screen resolution of 800x600 or higher Projection system, i.e. projector, Liquid Crystal Display (LCD), or TV (recommended, but not required)
System Installation
First, put the software disk in computer drive. Second, open it, double click setup_Enjoy_All.exe in the root directory. Third, install it following the prompt displayed. If it has been installed, we suggest you uninstall the old one before install the new. The default installation path is: C:\Program Files\Enjoy ARS., and it will produce three shortcut icons on the desk: ENJOY Quiz Master,ENJOY Quiz Freedom and ENJOY Setting and Query.(For RF219, is ENJOY Quiz Master and ENJOY Quiz Freedom) If the receiver is USB interface, when you connect the receiver with PC for the first time, you should install the USB driver. After the USB driver installed correctly, you can find there will be a new virtual Com Port in your PC hardware manager. The virtual Com Port number should be set lower than 17. Before use Enjoy ARS software, you maybe need select the hardware type use a setting program. The default path is Start -> all program -> Enjoy ARS -> Hardware type setting -> 88888888(default password) -> choose hardware type.
1.1. Quiz Genius 1.1.1. The normal progresses of using a Quiz Genius are as following:
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 11
Run the ENJOY Quiz Master mode stop records select activity mode view result
press start
But not every progress is necessary in an activity. Lets introduce them one by one.
(1). Set Class: You may reset the information of the class by click Class Set button. (2). Load a paper: Load a prepared quiz paper. In Ad-lib Quiz, Attendance(Rollcall) and Grouping, it doesnt need to load papers. (3). Select Participate Mode: (default mode is by individual) Choose the audience participate form, by individual or by group. If by group, the response of any member in a group will delegate the whole group. (4). Select Activity Modes: (default mode may be preset while editing the paper)
Choose a conducting active mode. We will introduce them later (See 1.1.2 Activity Modes Describe).
(5). Run / present question: After finishing the above setting, we will start an interesting quiz. Press the instructor remote power key or click the button in the program, the present will show as bellow. You can auto show the quiz by holding press Shift key at the same time when clicking the button. That means the system will present the questions one by one automatically. The teacher can preset the transfer time. (6). Start Gathering. After the instructor clicked the start/pause button (by PC mouse or by remote), the system will then begin to gather signals from the audience remote, shown as following:
2-status bar: indicate the following message: current page number/total page number, replied audience number/total audience number and some information about the operation. 3-Command menu: Include the following keys Previous Page, Next Page, Start/Pause, Stop, Result, Report, F1, F2 and Exit. It is used to control the presentation slides, and the proceeding of quiz. 4-Activity mode indicator: show the current activity mode. 5-Timer: It begins to countdown while the system began to gather the response information (The timers color becomes green). It will show the time remained (count by second). It will alarm when the time remained is less than 10 seconds. When it comes 0, the receiver will stop receiving the response of the audience (The timers color becomes red). The instructor may press the stop button ahead of it to stop gathering information. If time is not enough, the instructor may press the start/pause button or click the Pause key in command menu to stop countdown temporarily (The timers color becomes yellow). 6-Answering status bar: show the ID numbers of the audience (or group numbers), every number has background color, black is default color, gray indicates absence, blue indicates response signal received, (the audience can change their choice, the background color will change between navy-blue and Cambridge blue, the system will record the last press signal). While displaying the result, the background color will change red or green, red indicates wrong answer, green indicates right. (7). Result and Report Press the button result (by mouse or instructor remote), the display wil l show the result (red or green, green indicate correct) of every audience on the answering status bar, and multiple-choice histogram, green indicate correct option. Press the button report (by mouse or instructor remote), it will show the score board of the audience. (8). Exit
Press the power remote button or the exit key by mouse, the system will ask whether you intended to exit or not, and prompt you to save the records.
total scores of each object and the sort by total mark or average mark. (6).Ad-lib Quiz: It is used for the quiz with standardized multiple-choice and one right answer. It needn't slides prepared by using the Paper Editor. The instructor explains or describes (dictate or write on the blackboard or by other means) the questions and choices, and then press start. The audiences press the remotes to response. After the instructor pressed the "stop" button, the software will stop gathering information from the audience remotes, and ask the instructor to set the right choice and scores of the questions, and display the result and reports subsequently. (7).Hand-raise: It is used for the quiz without standardized choice. The instructor displays the paper and press start, the audience who click the "Rush Quiz" first, gets the power to response (answering or asking questions, or do anything else). The instructor grades the audience according his/her response, adds score or deducts score. (8).Attendance(Rollcall): The participation mode is restricted to individual. After the instructor press "start", the audiences press any key. When the instructor presses "stop", the Rollcall is over, the software will pop-up the roll book. The response procedure is for Fixed ID type class.
There is another response procedure for Unfixed ID type class, showing as below:(this is for RF219 only)
The students should input their student No for attendance check. (9).Grouping: The participation mode is restricted to individual. The audiences who press "A" are arranged into group 1, " B", group 2 "F", group 6, "Rush Quiz", group 7, The audiences who have not pressed any key will be added to group 1. The grouping is over when the instructor presses "stop", and the software will display the member amount and proportion of every group. The answering status bar will show the group number of every audience by displaying different color.
14
(10).Multi mode: In one activity multi mode such as Normal Quiz, Random Call, Hand-raise, Ad-lib Quiz and Feedback can be selected. The teacher can press "mode switch" button on the teacher remoter to switch activity mode, and press "?" button can select Feedback mode directly.
(1).Genius: Exit Paper Editor, switch to Quiz Genius. (2).Load: Load a PPT file (a quiz paper) prepared. The default load path is: (Installation Path)\ paper base. (3).New: The system will list models for choice to edit a new paper. The instructor may use their individual models prepared. If the user doesnt choose the modules, the system will produce a blank slide. (4).Save: Save the current paper. The default path is: (Installation Path) \ paper base. (5).Info: Display the papers information including test paper name, path of test paper, total questions, total mark, total time limited, statistic of item difficulty, statistic and list of questions with no right choice. (6).Add: Add a question (slide) according the model if have selected a model, else add a question copy of the question 1 or a blank question (slide). (7).Question model: we can also add a question by select a question model.
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 15
(8).Del: Delete a current question. (9).Question Set: Set the questions mark, right answer, time limited and so on. Press the button, open the question set window as below:
This is for RF219 A. File default mode and Qu. default mode: Set the default type of the file's activity mode: 'Normal Quiz', 'Rush Quiz', 'Elimination', 'Vote & Inquiry', 'Grade', 'Hand-raise' and Multi mode'. Choose one from the 7. If 'Multi mode' is selected, the "Qu. default mode" can be set for each question. B. Question No.: Display or select a question.
16
C. Question Title (Grade Object): Input the question title or the brief of question (object name in Grade mode), the default content is Question number or Grade object number. D. Mark and Time: input the mark and the time limited of the current question. E. Answer options setting: Input the choices content. If we edited the file by using Enjoy software model or have denominated the question title and options, we can use the "Auto acquire" button to get the content of question title and answer options automatically. F. Answer Type and Correct answer selection: For IR117/IR118/RF217/RF218/RF219: set answer type and correct options. If Answer type is 'A-F Single', only one correct option can be selected; If answer type is '0-100', the correct option will be selected from "0 to 100". Click "Apply all" button means same setting for all questions in the paper. For RF219, Question type can be set as 1/n, True/False, Yes/No, Fill up text, Fill up number, Sort order, Catalogue, 2/n, 3/n, 4/n, ?/n, Right/Wrong, Vote/Against, and Positive/Negative; The option code can be described as letters (ABC) or numbers(123). G. Difficulty level: Input the difficulty degree of the question. H. Rush Quiz set: Input the deduce mark (when the answer is wrong), and the answering time limited after getting the answering power. I. Set correct answer: This point is very important. The system can decide who will be right and who will be wrong only you have set correct answer for questions. J.Auto built answering histogram on slide: If you select this option, a result chart will be created on the right down corner of the slide, and some reply information will be appended to the remark bar of the slide. K. Exclude give up: set for statistical calculation of proportion, include or exclude the people who give up reply. L. Valid Options: Set the valid options for question. The invalid options will not be received. M.qu. Advance: set for result interface, include color, font, content and default display mode.
different types of models for different use. And the choice has been denominated, we may use the Auto acquire expediently.
(1). Load: Load a PPT model file (*.POT), the default load path is: (Installation Path)\module. (2). New: Create a new model file (3). Save: Save the current model file (*.POT), the default save path is (Installation Path)\module. (4). Info: Include the quantity of question models, the denomination information of the choices and question title. (5). Add: add a question model (a slide) (6). Del: delete a question model (a slide). (7). Model Name modify: rename the question model. (8). Denominate options: denominate which one is the Question Title, Which one is Option A, Option B and so on, If the choice has been denominated, we may use the Auto acquire expediently while setting the questions.
password protected. The default password is 12345678. 2.1.4 Student Set The managing of class Includes Import and Export the information of classes (excel file), Create a new class, Delete a class and Rename a class. The managing of student includes Add a student record (include Student ID, Stude nt Name and Group No), Modify a students information, Del a student, Save and Grouping. 2.1.5 Teacher Set Include Add, Modify, Delete and Save the teacher information. 2.1.6 Subject Set Include Add,Modify, Delete and Save the subj ect information. 2.1.7 System Set 1.Modify Password: modify administer log on password and modify data administer password. 2.Quiz Genius default setting. 3.Quiz Genius music setting: set the music of Enter Activity, Start Answer, Stop Answer, Accept Command, Warning and Count Down alarm.
2.2 Query
The software offers three ways to query the activity record: query by class, query by person and query by activity. Choose the Class name, subject, activity time and activities, then press Query button, the report will show in the window. The reports can be printed and can be exported to html or text file. 2.2.1 Query by class: Include Class grade list, Class answer details, Class roll book and Class activities summary. 2.2.2 Query by person: Include Student score ledger, Student answer details and Student roll book. 2.2.3 Query by Activity: Include Question accuracy queue, Multiple-choice queue, Multiple-choice queue histogram and Grade details. 2.2.4. Others: Include Modify answer and score and Calculate score weighted. The activities modes and their corresponding reports Norm al Quiz Class grade list Class answer details Class roll book Class activities summary Student score ledger Student Ru sh Qui z Eliminati on Vote, Inquiry Grad e Ad-li b Quiz Hand raise Rollc all Groupi ng
19
answer details Student Roll Book Question accuracy queue Multiple-choi ce queue Multiple-choi ce queue histogram Grade details
1. Command Buttons: includes paper operating command (Import and Export paper, create a new paper and save paper), question operating command (add, delete, move up and move down) and other command (exit, help) 2. Editor Area: You can set score and answer of questions; edit the name and choices of questions. 3. Display Area: List the information of all questions. Paper format as shown below:
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 20
Number
Score
Correct Choice
Title
Option A
1-250
0-250
A\B\C\D\E\F Or uncertain
1. Command Buttons: Used to control the progress of exam. Start/Pause: Click the "start" button by mouse or press the instructor remote "start" key) to begin the exam, the timer will turn green and began to count down. The start button act as a start/pause transfer timer button, when press again, the timer will turn yellow and stop counting down. And when the instructor presses again, it will turn green and began to
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 21
count down again. We can also press the "up" or "down" key beside the timer (or the instructor remote "up" and "down" key) to adjust the exam remain time. Stop: Click the "stop" (by mouse or press the instructor remote "stop" key), the exam is over, the receiver stop receiving the response information from the student remotes, and the timer turn red and stop counting down. Result: Click the "result" (by mouse or press the instructor remote "result" key); the system will display the option histogram. Press the up or down key to display the option histogram of the previous or next question. Press "F1" to select whether declares the correct answer. Press "F2" to view the answering details. Report: Click the "report" (by mouse or press the instructor remote "report" key); the system will display the scores list of students. Help: Display the help document. Exit: Press "exit" by mouse or press the "power" key of the instructor remote, we will exit this program. The system will prompt whether save the exam record or not. 2. Answering information bar: Used to display the answering information of the students. A blue shaded box indicates that the question has been answered. A green ID number is an indicator that the participant has answered all the questions in the test set. 3. Status bar: Used to show the total number of Questions and the amount of students finished.
4.
4.1.1 Class set The system will ask you to Choose class name, teacher name and subject name. If the information has not been set before, or we use is casually, we may choose Temporary Class, Temporary Teacher, Temporary Subject, and input the number of the Class (do not include the instructor). The ID number and the name of the audience will be listed on the right side. You can also select participate mode, do some default set, such as default quiz mode, score, time limited, valid options, Exclude give up, show quiz window and get short
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 22
message. When complete class set, the system will test connection between PC and Receiver. If the test fails, error message will appear. 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 System set: Run Enjoy ARS system setting (same as 2.1 Setting). Record Query: Run Enjoy ARS record query (same as 2.2 Query). Help: Open Quiz freedom help file. Virtual Page Up/Down: In this status, you can simulate Page Up and Page Enter Quiz mode: Click Power button, the system will enter quiz mode, shown
Down keys of keyboard by pressing the Up and Down keys on teacher remoter. as following: (Press Mode Switch key on teacher remoter, the system can enter quiz mode and begin a new quiz at same time, or press ? key on teacher remoter, the system can begin a new feedback at same time.)
4.2
In quiz mode status, there are question no, answered persons, quiz mode, question type, timer, and control button on floating toolbar. Click control button, a control menu will pop up, shown as right: 4.2.1 ID box set: Set ID box display mode, switch time, and open or close short message window. 4.2.2 New Quiz: Click New Quiz menu or press Mode Switch key on teacher remoter, a new quiz will be created. If the default set is show quiz set window, a setting window for new quiz will display. You can set quiz mode (question type), score, time limited and so on. Other wise, no setting window will display, the quiz will start to reply directly. 4.2.3 New Feedback(for IR117/118/RF217/RF218): Click New Feedback menu or press ? key on teacher remoter, a new Feedback will be created. If the default set is show quiz set window, a setting window for new feedback will display. You can set feedback type, time limited and so on. Other wise, no setting window will display, the feedback will start to reply directly. 4.2.4 Control quiz process: You can control the quiz process by mouse or teacher remoter. You can start/pause or stop reply, view the answering result/detail of previous or next quiz, view the top table and so on. All process is same as Quiz Master. 4.2.5 Set Correct answer: Because there is no question editor in Quiz freedom, you have to set correct answer after the question have answered. You can set correct answer when viewing answering result. 4.2.6 Capture function: When viewing answering result, detail or top table, you can click Capture button, then select a rectangle area. The rectangle will be saved to system clipboard as a picture. By using Paste function, you can save answering chart to your document easily.
ENJOY Technology Co., Ltd. Tel: 86-20-32761209 http://www.enjoy-ars.com Email: enjoy-ars@hotmail.com 23
Part 4. Note
1. For RF219/RF218/RF217, the receiver cant be covered by metal; keep far away from strong electric field and magnetic field; keep far away from strong 2.4G RF signal. 2. For IR118 & IR117, the receiver cant work in sunlight; keep far away from strong infrared ray signal; keep the cover clear. 3. Avoid irradiation of teacher remoter Laser to eyes. 4. The receiver cant be connected to two or more than two programs such as Quiz Master, Setting and Query, Standard Exam or Quiz Freedom at same time.
24